basic understanding of PLC and drive Communication.how plc send command to drive.how drive send feedback to plc,plc and drive communication network overview,how to start drive from plc,basic network arrangements of plc and drive.what is logic command word,what is logic status word. Plc to drive communication
speed and torque mode of VFD
• 🔴Speed and torque mode...

Опубликовано:

 

13 сен 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 89   
@mdmahtabalam925
@mdmahtabalam925 3 месяца назад
nice explained sir
@bijendrasingh6185
@bijendrasingh6185 3 года назад
sir, extremely nice video. please share more videos .your explanation is very conceptual.
@r.d.245
@r.d.245 4 года назад
Aap bahot achchhi tarah samjhate ak dam samjh me aa jata h
@naveenkadkol9731
@naveenkadkol9731 4 года назад
It was really a good explanation on communication between PLC and drive. Can you please make a video on PLC getting commands from other applications and pass on those communication to drive and vice versa. In short, Application PLC Drive Thanks in advance 🙏🙏🙏
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Ur vedio very nice , & ur understanding ability so nic. Thanks.
@anandpatel2690
@anandpatel2690 4 года назад
Truly helpful Thank You.
@nagarajukapileswarapu1294
@nagarajukapileswarapu1294 4 года назад
Sir your teaching skills are so good please make a video on servo communication too
@Mithilesh658
@Mithilesh658 3 года назад
Very nice video sir🙏🙏
@subramaniankrishnakumar3821
@subramaniankrishnakumar3821 5 лет назад
Brother really thanks. Good teaching skill you have.
@aforautomation
@aforautomation 5 лет назад
thanks brother keep watching.. keep supporting.
@abhishektiv4400
@abhishektiv4400 3 года назад
Good 👍
@mukeshthakur-gu9gp
@mukeshthakur-gu9gp 5 лет назад
Thank you sir
@PankajTiwari-di1zq
@PankajTiwari-di1zq 5 лет назад
Sir thank u so much for this kind of vidio on drives......your explanation is very clean and easy to understand......specially i like to listen "theeek hai n" from u after every sent.....😍😍😍😍😍......nd sir plz make a vidio on master slave drive configuration......how we can operate two drive as master slave .......once agian thankxxxx......
@aforautomation
@aforautomation 5 лет назад
thanks a lot Pankaj god bless you
@Surya.EMF.Automation
@Surya.EMF.Automation Год назад
𝐍𝐢𝐜𝐞 𝐄𝐱𝐩𝐥𝐚𝐢𝐧𝐬
@vinodbankar8942
@vinodbankar8942 2 года назад
👌
@ganeshlande9723
@ganeshlande9723 Год назад
Very nice sir Thik hai na, repeat mat Karna.
@vikramkaushik1767
@vikramkaushik1767 3 года назад
sir please make a video in continuation of this video: communication between plc and drive
@atiqrehman8001
@atiqrehman8001 5 лет назад
I am second great work sir. God bless you.
@sonasharma5627
@sonasharma5627 4 года назад
sir siemens ki plc me prog addr karne ke liye .db2.db4 is tarah se use karte h..wo samajh nahi lagta h.can u explain it sir
@jasinaj5397
@jasinaj5397 5 лет назад
😘😘😘
@rajushaikh5079
@rajushaikh5079 3 года назад
Sir make more video about industrial automation(plc, instrumentation,scada,
@pankajsanwal2010
@pankajsanwal2010 4 года назад
8 bit ya 16 bit ke adopter same honge ya different ? Unke cable bhi alag honge, optical fibre cabe ko chhodkar ? Kyonki whan par to do hi cable hote hain ek input ke liye doosra output ke liye .
@aforautomation
@aforautomation 4 года назад
Adapter and other hardware depends upon the type of PLC is used and communication network.
@mukeshthakur-gu9gp
@mukeshthakur-gu9gp 5 лет назад
Sir please explain relative or magnetic sensor
@pardeepsharma8657
@pardeepsharma8657 5 лет назад
Good
@aforautomation
@aforautomation 5 лет назад
in next video i will upload practical example of this video so keep watching and subscribe my channel if you like this type of content
@parveensinghania8809
@parveensinghania8809 4 года назад
A for Automation please make a vedio on Profibus communication,
@nageshpandey5333
@nageshpandey5333 4 года назад
Sir please make a video with program in Siemens and abb PLC and drives
@shashankkumar7770
@shashankkumar7770 3 года назад
Please make videos on profibus tracer
@anshulkumar-kl4pr
@anshulkumar-kl4pr 5 лет назад
Sir yahi baat computer par bataiye very good video
@aforautomation
@aforautomation 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Q-IMfwXEJk8.html
@nageshpandey5333
@nageshpandey5333 4 года назад
Sir ek video PLC k specifications sheet or chart Ko explain kar k banayiyega
@chauhanvijaysinh7737
@chauhanvijaysinh7737 5 лет назад
Nice sir most usefull lacture
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Plz tell me with details of LSW .thanks
@pankajsanwal2010
@pankajsanwal2010 4 года назад
Sir LCW main 10th se 15th number tak ke bit ke section main jo command honi chahiye wahan par cross mark kiya hua hai . Iski kya wajah hai kya wahan par zero ya one kuchh nahi ho sakta hai ?
@aforautomation
@aforautomation 4 года назад
X means thease bit are not used they are reserved for future upgradation.jab drive ka new version ayega to in bits ko use kiya jayega kuch new command add karne k liye.
@pankajsanwal2010
@pankajsanwal2010 4 года назад
Thanks
@KrishnaSingh-sm4nc
@KrishnaSingh-sm4nc 5 лет назад
hii sir vfd ka work kart a hu kiya ap iski repairing bta skte ho
@r.d.245
@r.d.245 4 года назад
Nice Sr ji⚘⚘⚘ Sr ji mujhe ak bat bata jigiy a jo bit 1 ya 0 bit y kya 24 DC v me jata h y bit kaise apana signal bhejata h frequency dwar ya kis tarah se please batane ki kripa kare msg dwara ya kisi bhi tarike plg sr
@tekramsahu9050
@tekramsahu9050 5 лет назад
sir plc se, realy k thrue drive ko dete hai kya?
@aforautomation
@aforautomation 5 лет назад
Nahi this video is regarding communication through Network
@mueezkhan4429
@mueezkhan4429 3 года назад
Sir make a more video with program abb
@vasudevpandya2424
@vasudevpandya2424 5 лет назад
Please sir one more vidio of communication between pid and drive
@aforautomation
@aforautomation 5 лет назад
i will make lot more.stay connected and thank you so much for watching..
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Agar aapki vedio starting se dekhne ko mil jaye toh aur better samajh me aayga.
@anushkakiranlamba9046
@anushkakiranlamba9046 5 лет назад
sir PPO, PZD, PKW kya hota hai drive mai.....aur plc kaise isko use karta hai, iske bare mai please video banaiye
@aforautomation
@aforautomation 5 лет назад
I think thease are the name of TAG or memory location in PLC program , have you seen these names in drive parameter/user manual ? I am not sure but it may be short form of some machine name. Where did you saw thease words please reply then i can understand better.
@aforautomation
@aforautomation 5 лет назад
support.industry.siemens.com/tf/WW/en/posts/meaning-of-ppo-pzd-and-pkw/156488?page=0&pageSize=10 Go in above link you will find answer
@anushkakiranlamba9046
@anushkakiranlamba9046 5 лет назад
Sir, I was trying to establish communication between siemens plc and abb dcs 800 drive through profibus. The PPO term came into picture after I installed the GSD file for abb drive. Then we have to select I/O type( here I got one option as PPO type 1,2,3,4 or 5), so that the plc can R/W data from drive.
@syedadnanmoin2111
@syedadnanmoin2111 5 лет назад
Hi... What will be the reference address for logic command word to send command to drive
@aforautomation
@aforautomation 5 лет назад
There are Fixed address for thease commnads, when we configure hardware and connect in network which is used to communicate with PLC, some address tags are generated in PLC memory like for unwinder it will show like Uncoiler:O.Logiccommand
@syedadnanmoin2111
@syedadnanmoin2111 5 лет назад
OK... And need to set any parameters of VFD for reciving data?.. Actually having trouble in fetching the data from ACS550 drive.. Any suggestions will be helpfull
@suhelansari7048
@suhelansari7048 5 лет назад
sir ek bar precticaly vfd me parameter bhar ke video banao na
@aforautomation
@aforautomation 5 лет назад
next video practical hoga keep in touch brother
@majanudeewana9831
@majanudeewana9831 4 года назад
Sir Riley Motor Sensor Atocot Speet setting Video
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Lsw se matlab aapka drive feedback se hai kya
@aforautomation
@aforautomation 5 лет назад
yes logic status word ye drive ka status ka feedback hota hai jo plc ko jata hai
@kaatnikaatni9012
@kaatnikaatni9012 5 лет назад
Sir what is Enable on Drive?
@aforautomation
@aforautomation 5 лет назад
Enable is a digital input which is reserved for emergency stop some time this input comes from from plc and sumtimes through hard wire wiring.this is for safety purpose and it never should be bypassed.if drive does not receive this input motor will stop immediately .and this stop will be coast to stop
@sushilkumarshukla9476
@sushilkumarshukla9476 4 года назад
Dear sir please provide an lecture on IMCC panel and their communication with plc for feedback and control
@vishalgovekar6369
@vishalgovekar6369 5 лет назад
Please do practically
@aforautomation
@aforautomation 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Q-IMfwXEJk8.html this is one practical example of same i will make some more for more clarification. thanks for watching.
@angadgupta7737
@angadgupta7737 4 года назад
Sir ji CPU and drive ke beech jo cable lagata hai use kaun sa cable kahte hain
@aforautomation
@aforautomation 4 года назад
Cable bahut si type ki ho sakti hain jaise ki Profibus/Ethernet/Controlnet/Can bus/Modbus ye sab plc k type aur network requirement k hisab se design kiya jata hai. jaise ki plc aur drive k bich me distance kitna hai,Total drive kitne add karne hain etc.
@angadgupta7737
@angadgupta7737 4 года назад
@@aforautomation thank you sir ji
@angadgupta7737
@angadgupta7737 4 года назад
Sir ji program ko kaise upload karte hain usper video banaiye please
@syedsaad5781
@syedsaad5781 2 года назад
Ager communication time out error ata hai To is fault ko kis tarah remove kia ja sakta hai
@aforautomation
@aforautomation 2 года назад
there are some time out time settings in communication parameters, you can increase the time or baud rate is to be decreased in communication parameters,check cable and change its route if possible
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Sir apki vedio starting se kaise dekh sakta hu.
@aforautomation
@aforautomation 5 лет назад
channel k naam pe click karo jahan A For Automation likha hai phir upar video pe click karo sare video ki list open ho jayegi
@raselrana9528
@raselrana9528 2 года назад
Allen Bradley 20-comm-p Profibus vfd speed problem
@aforautomation
@aforautomation 2 года назад
what is problem like speed is less or speed reference is not working?
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Sir ji logic status word se jo command jati hai vo plc me jati hai kya.agar jati hai toh ye plc ke liye kya hoti aur drive ke liye kya hoti hai.
@aforautomation
@aforautomation 5 лет назад
lsw drive se plc me jata hai as a.feedback jaise ki drive ready,drive running, drive faulty etc..
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
@@aforautomation , sorry sir but one more question ,LCW will connect with input plc module or output module.I mean that LCW will be for plc input or output
@aforautomation
@aforautomation 5 лет назад
LSW input ya output module me nahi jata ye direct communication cable se plc me pahuch jata hai..
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
@@aforautomation , thanks sir , I understand.
@bhupenderbhati7
@bhupenderbhati7 5 лет назад
Running, faulted, enabled & jog rev etc ko indicate karne ke liye plc se lamp(24 v) on karate hai.
@thakorjagdish9616
@thakorjagdish9616 5 лет назад
Schneider drive or yaskawa drive communications kase kare please sir
@aforautomation
@aforautomation 5 лет назад
which network you want to use ? or you can use analogue input output for speed reference and feedback
@angadgupta7737
@angadgupta7737 4 года назад
Hello sir ji
@aforautomation
@aforautomation 4 года назад
hello
@akhtarshamim2424
@akhtarshamim2424 4 года назад
Hi
@aforautomation
@aforautomation 4 года назад
Hello, thanks for watching
@edgaregan2421
@edgaregan2421 3 года назад
English please?
@Surya.EMF.Automation
@Surya.EMF.Automation Год назад
𝐈𝐬𝐤𝐚 𝐝𝐮𝐬𝐫𝐚 𝐩𝐚𝐫𝐭 𝐤𝐚𝐛 𝐚𝐚𝐲𝐞𝐠𝐚
Далее
Разоблачение ушные свечи
00:28
Просмотров 472 тыс.
Basic Ladder Logic (Full Lecture)
36:05
Просмотров 416 тыс.