Тёмный
A For Automation
A For Automation
A For Automation
Подписаться
THIS CHANNEL IS TO HELP YOUNG ELECTRICAL,ELECTRONICS AND INSTRUMENTATION ENGINEERS WHO ARE WORKING WITH PROGRAMMABLE LOGIC CONTROLLERS,VARIABLE FREQUENCY DRIVES,PROCESS INSTRUMENTS..SUBSCRIBE THIS CHANNEL IF YOU WANT TO LEARN ABOVE THINGS IN DEEP. THANK-YOU SO MUCH FOR WATCHING MY VIDEOS PLEASE SHARE WITH FRESHER ENGINEERS..
🔴How Ground Fault is Detected?
10:26
Год назад
🔴AIR TO GAS RATIO CONTROL BY PLC🔵
12:49
3 года назад
🔴PID BASICS PART#3🔵
11:27
4 года назад
🔴PID BASICS Part#2 In Hindi🔵
7:47
4 года назад
🔴PID BASICS Part #1(IN Hindi)🔵
7:41
4 года назад
Комментарии
@jaichaudhary7783
@jaichaudhary7783 3 дня назад
Winder under app k vdo kha h
@AnnadYadav-mh2mt
@AnnadYadav-mh2mt 9 дней назад
Very thank।you
@narvatsinhrathod5597
@narvatsinhrathod5597 12 дней назад
Flying start p/m in acs 560 abb.
@samarsekharreddy
@samarsekharreddy 23 дня назад
What an explanation excellent
@Heera-mp5kw
@Heera-mp5kw Месяц назад
sir DC drive ka bhi video banaw n sir g please❤❤❤❤❤❤
@kuldeepdhiman7570
@kuldeepdhiman7570 Месяц назад
Sir, please tell me whether it is necessary to change any parameters in the DC drive to get pulse signal from A_ and B_ in the encoder or will the drive run without any problem by connecting these in place of A and B wires?
@aforautomation
@aforautomation Месяц назад
It will run without any problem
@askarindamroy
@askarindamroy Месяц назад
Very Informative video. 😊
@arvindkumarkumar5934
@arvindkumarkumar5934 2 месяца назад
Autotune but overshoot. Eurotherm
@aforautomation
@aforautomation 2 месяца назад
Decrease the gain and try manual tune.
@rakeshverma-lr6pf
@rakeshverma-lr6pf 2 месяца назад
Sir Tia portal ke upar video banaye s
@arakerielectricalindustrie1546
@arakerielectricalindustrie1546 2 месяца назад
Fekadu 😂
@arunpaul6195
@arunpaul6195 2 месяца назад
Sir, when stop button from scada is pressed continuously the motor come to stop when rpm goes down. When button is released it runs again what may be the cause
@aforautomation
@aforautomation 2 месяца назад
Start command in continously high from PLC or Hardwiring and Start stop parameter needs to be check.
@ashvineborade4299
@ashvineborade4299 2 месяца назад
अदभुत विस्तार से बताया है,धन्यवाद
@car9167
@car9167 2 месяца назад
Can the formula at 8:00 be used for output reactor (from VFD to motor)? What frequency do you use? My motor goes from 3000RPM to 18,000RPM (so 50Hz to 300Hz). Do you use 300Hz for calculation?
@httrelectronic6082
@httrelectronic6082 3 месяца назад
Why not drive trip in unbalanced??
@pixeledgeautomation7748
@pixeledgeautomation7748 3 месяца назад
Sir ji Siemens ka kya parameters hai
@anshultiwari922
@anshultiwari922 3 месяца назад
plz send pid sheet link
@samiullahchohan7762
@samiullahchohan7762 3 месяца назад
Fantastic sir
@muhdsalman4386
@muhdsalman4386 3 месяца назад
Dc shunt compound ke बारे में भी वीडियो बनाओ
@mdmahtabalam925
@mdmahtabalam925 3 месяца назад
nice explained sir
@SaifulIslam-fd1wg
@SaifulIslam-fd1wg 4 месяца назад
A Dc motor arm vot 470 and ext volt 310, 60hz if we apply in input of dc drive arm volt 400 and 310 ext, 50 hz what will happen? please let me know
@aforautomation
@aforautomation 3 месяца назад
You have to set Input power frequency in drive parameter, drive measures frequency by itself and it will generate fault if set 50 Hz and apply 60Hz.
@aforautomation
@aforautomation 3 месяца назад
Based on Input power frequency the SCR switching time and ramp generation signal is changed
@monzurhasan3583
@monzurhasan3583 4 месяца назад
Perfect
@imfilmy2
@imfilmy2 4 месяца назад
What do you want to say??
@RajRaj-jw8xg
@RajRaj-jw8xg 4 месяца назад
Sir your namber
@aforautomation
@aforautomation 4 месяца назад
please drop mail on aforautomations@gmail.com
@shashankkumar2032
@shashankkumar2032 4 месяца назад
sir 🙏, Sir i have used kinetix 5100 servo amplifier with auxiliary feedback encoder, kindly guide which parameters no is for feedback pulses.
@aforautomation
@aforautomation 4 месяца назад
P5. 017, Aux encoder position
@aforautomation
@aforautomation 4 месяца назад
I can share the list with you, plz share your mail id
@waheedahmad155
@waheedahmad155 4 месяца назад
Can we used pid in weighing controle process
@aforautomation
@aforautomation 4 месяца назад
PID can be used in any close loop control applications.
@sbindra3682
@sbindra3682 4 месяца назад
Sir Bihar power corporation me. AC Aur DC drive diya hai . uska exam may me hai. app fir se AC and DC drive lecture le ligiye sir please
@VijayChoudhary-hc3zk
@VijayChoudhary-hc3zk 5 месяцев назад
ct ke Baad star points kyu banate Hain?
@Kitty_minnie12
@Kitty_minnie12 5 месяцев назад
Multispan d.c.draiv ke canection batane ki kripa kare
@aforautomation
@aforautomation 4 месяца назад
Plz share model number or catalog number of drive
@ganeshhande7999
@ganeshhande7999 5 месяцев назад
मेरा सिंगल फेज INVT ड्राईव्ह है V FD से मोटार नदी मे अंतर 100 मीटर लंबा है पंधरा HP मोटर है कोनासा चोक लगाये कृपया बताये ?
@aforautomation
@aforautomation 4 месяца назад
I will recommend 0.6mH, 30A Ins class-H, 3% reactor.
@aforautomation
@aforautomation 4 месяца назад
I have uploaded a picture for the formula
@TheChinmay22
@TheChinmay22 5 месяцев назад
Very good video.
@akashkarmakar1572
@akashkarmakar1572 5 месяцев назад
Same formula maine PLC logic main use kiya, lekin jab line speed 0 MPM hota hai tab deflector roll and rewinder ka speed bhi 0 RPM ho jata hai. Tab yeah equation invalid ho jata hai. Iss calculation main kya sudhar kar sakte hai?
@aforautomation
@aforautomation 4 месяца назад
Very nice to see this question, the value you are finding is instant Dia meter, for diameter after ramp you need to add some value to the instant Dia. This value is called change in dia meter which needs to be calculated by encoder counts feedback.
@aforautomation
@aforautomation 4 месяца назад
If you wish I can share the Logic with you. Please let me know your email
@jayaramanneelatur9178
@jayaramanneelatur9178 5 месяцев назад
Sir Take your fees to improve our skill.
@jayaramanneelatur9178
@jayaramanneelatur9178 5 месяцев назад
Sir ThankQ & God Bless you
@oorkruiser
@oorkruiser 5 месяцев назад
With closed loop vector control you can also accurately control motor torque above rated nameplate speed.
@aforautomation
@aforautomation 5 месяцев назад
Yes you are right, close loop vector control performance is best.
@sumits_shetty
@sumits_shetty 5 месяцев назад
VL - L kya hai ? 440-400? Pls explain
@adnanyounaskhan986
@adnanyounaskhan986 5 месяцев назад
Sir please make a video on Direct torque control method and how can we give torque reference
@fansari4454
@fansari4454 5 месяцев назад
Sir dancer roll pe video banaeye
@girishvasani8307
@girishvasani8307 5 месяцев назад
Gurjii Aap ko Namsakar aap ko dhanya he aap ko me dil se namaskar karate hu
@aforautomation
@aforautomation 4 месяца назад
Namaskar Bhai
@user-px5no9nv2k
@user-px5no9nv2k 5 месяцев назад
Siemens g120 vfd ka profibus comunication parameter kon kon sa set korna porta hai , bata sakta hai keya sir?
@vinodbankar8942
@vinodbankar8942 5 месяцев назад
Siemens starter ke upr video banao sir aisa
@nitinmaind8967
@nitinmaind8967 5 месяцев назад
After long months How are you sir ?
@aforautomation
@aforautomation 5 месяцев назад
I am Good Nitin. How are you?
@harshvardhangaikwad3560
@harshvardhangaikwad3560 5 месяцев назад
Please sir ji Electric drives and control Subject ki all Topics ke playlists uploaded karo sir👍
@dipankardeo8479
@dipankardeo8479 6 месяцев назад
Sir make vodeo to calculate MPM .. DEFLECTOR ROLL ENCODER
@technomakealam
@technomakealam 6 месяцев назад
Nice
@technomakealam
@technomakealam 6 месяцев назад
youtube.com/@technomakealam?si=ue1HCf0zTnWdi6Hp
@sachinthakur3144
@sachinthakur3144 6 месяцев назад
DC Drive par videos banao
@ahmedbejaoui5718
@ahmedbejaoui5718 6 месяцев назад
we should programm the Emergency stop in the ladder diagram from the automate in logo 8 or we need only to wire it thanks
@user_00759
@user_00759 6 месяцев назад
Sir, how can I connect to LS-is7 / ig5a inverter?
@dayanandagasagi8476
@dayanandagasagi8476 7 месяцев назад
Please explen how to work DC drive & plc in centrifugal machin in sugar plant,
@WNAZ-WALA
@WNAZ-WALA 7 месяцев назад
Thanks