1794-AENT Flex I/O Communication Module 

AB PLC Test Bench
Подписаться 1,8 тыс.
Просмотров 40 тыс.
50% 1

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@michaelpetermorley3797
@michaelpetermorley3797 5 месяцев назад
You’re a legend
@TheOrly89
@TheOrly89 2 года назад
Thank you, you save the day
@abplctestbench759
@abplctestbench759 2 года назад
Hi - Very glad to hear that my channel helped you. Thank you.
@josielmaia8982
@josielmaia8982 5 лет назад
Exelente explicação
@mouhabd5451
@mouhabd5451 Месяц назад
Merci
@jdpower123456
@jdpower123456 4 года назад
Thanks
@abplctestbench759
@abplctestbench759 4 года назад
You are welcome.
@mrtrader4628
@mrtrader4628 2 месяца назад
I trying to get it to take but I don't see my Flex I/O in linx when I connect from the laptop to the unit. the switch has 011 on the front this was given to us from a different plant as a trainer but I not having much luck connecting. bootp is see it so can you please tell me where I'm going wrong. MAC:0000bc376f2d We also have a switch in the trainer, but I tried but ways Thanks Darren.
@abplctestbench759
@abplctestbench759 2 месяца назад
Hi: You don't say if it is a series A or B. I suspect it is a series A. Try watching my other video - ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-VSc628BpRSE.html
@lesliemanlm
@lesliemanlm Год назад
Testing communication with the 1794-ASB module I'm troubleshooting these older version that use the blue wire with the EOL resistor, and they are daisy chained and goes to a scanner module 1747-SN, please advise
@abplctestbench759
@abplctestbench759 Год назад
HI Leslie: Yes that combination will work! It has been awhile since I hooked up a system like that. You are correct on the daisy chain - never do a star or ring configuration with the blue hose. If you change the switches on the ASB modules, you have to power down the ASB and power back up. You also have to have the communication speed set the same in all of the modules and match that in the SN scanner module. You need a resistor at each end of the blue hose - both of the same value and sized according to the speed that you set the communication at. Hope that all helps. Bruce
@Nicofish2023
@Nicofish2023 10 месяцев назад
Thanks sir. Please do you offer any training?
@abplctestbench759
@abplctestbench759 10 месяцев назад
Hello - No I do not. There is a link at the top of my page that shows www.plcs.net/ for training I would start there as there are multiple subjects and links for training. Thank you for asking.
@sgr.ghariwal
@sgr.ghariwal 4 года назад
What Could be a reason behind of Network Status LED Flashing?? Is it showing healthy?? It should be in steady state Condition. How do i rectify??
@abplctestbench759
@abplctestbench759 4 года назад
From the Rockwell manual it states: Flashing Green No Connections Module has obtained an IP address, but has no established connections. It would seem that there is no PLC talking to the AENT Module. There is a 90 page manual from Rockwell - Publication 1794-UM006A-EN-P - July 2001 I would suggest you go to the Rockwell manuals site and download the PDF. Hope this helps you.
@sgr.ghariwal
@sgr.ghariwal 4 года назад
@@abplctestbench759 Yes,Exactly but what could be the problem? Module itself having a problem or PLC problem?
@andresgallardo9015
@andresgallardo9015 6 лет назад
Nice video, good this stuff is on the internet. Do you know if I can use a 1756-L72 and a 1769-ENTR as a remote IO?
@clichepalmers
@clichepalmers 5 лет назад
Why when i try to select the reset module's network option is not available?
@clichepalmers
@clichepalmers 5 лет назад
Mmm... i'm doing the process that you wroted on your vídeo (on behind text) but, i write the ip adress on "MAC", an then i make a "ping" to adress and not responde to me. Do have whatsapp o contact for talk to you?
@ezjovolt
@ezjovolt 4 года назад
Same problem
@klingerguimaraes2772
@klingerguimaraes2772 3 года назад
can I use this device with siemens plc's?
@abplctestbench759
@abplctestbench759 3 года назад
Not that I know of. You would have to ask a Siemens PLC group if it can talk to AB/ Rockwell PLC's.
Далее
1794-OE4
9:02
Просмотров 4,8 тыс.
9월 15일 💙
1:23:23
Просмотров 1,2 млн
1794 Flex I/O Install and remove Properly
8:23
Просмотров 23 тыс.
What is Remote I/O?
5:41
Просмотров 98 тыс.
Allen Bradley Flex I/O Wiring Configuration - Part 2
3:27
Asignación IP Adaptador Flex IO Protocolo Ethernet IP
6:22
Adding a Powerflex 525 to RSlogix 5000 over ethernet
16:56
1794-AENTR Expansion Network and EDS File uploading
35:29