2023 230.71 Maximum Number of Service Disconnects 

Ryan Jackson
Подписаться 30 тыс.
Просмотров 4,8 тыс.
50% 1

One of the biggest changes in the 2020 NEC was 230.71(B). Some of the issues that it created were clarified and fixed in this edition.

Наука

Опубликовано:

 

2 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@monchyhernandez9698
@monchyhernandez9698 Год назад
Thank you..great vídeos!
@snewogerg
@snewogerg Год назад
Those disconnects at 10 minutes in the video are under the flap and is only a plastic cover. You can easily lift the cover and disconnect either of the services. No tools necessary. Common for duplexes.
@sokbok
@sokbok 8 месяцев назад
quality video on a compliated topic, thanks.
@vIsiOnsOfsAlvIa
@vIsiOnsOfsAlvIa 5 месяцев назад
Excellent Video
@chadgerman8173
@chadgerman8173 11 месяцев назад
Great video my friend!
@Sparky-ww5re
@Sparky-ww5re Год назад
12:20. The way I'm interpreting the ex. regarding existing installations, if you needed to replace a breaker on a pre-1980 split bus panel, you're allowed to do so provided the total number of breakers on the upper bus (main section) doesn't exceed six. Is that correct?
@lavacano
@lavacano Месяц назад
7:00 then for the same reason the GEC must not be bonded before the service disco but mike holt says otherwise; in fact he says you can bond at the weatherhead.
@RyanJacksonElectrical
@RyanJacksonElectrical Месяц назад
You can bond a grounding electrode conductor to as many places as you would like.
@Bob.W.
@Bob.W. Год назад
I had a 1960 Federal Pacific main panel with 6 sets of pull out fuse blocks and plug fuses. Odd duck.
@jonzuber7193
@jonzuber7193 6 месяцев назад
So who makes a 400A meter main that complies with 2020 NEC 230.71? Can you list a few models? I have a 400amp main panel in my garage/workshop with pass thru lugs to a 200amp panel in my house with pass thru lugs to a 100amp smart panel in my basement. I live off grid in a remote area and run my entire site using PV Solar Energy and would like to add EMS to manage my entire site.
@danlund4054
@danlund4054 Год назад
So who makes a 320A meter main that complies with 2020 NEC 230.71? Can you list a few models? Every model I find with two 200A breakers has both breakers in the same compartment. One example is Siemens MM0404B1400RLM.
@JeremySpidle
@JeremySpidle Год назад
You haven't lived until you've made measurements on the exposed live bus-work of a multi Megawatt MCC in a level 4 arc flash/blast suit at over 100°F
@Californians_go_home
@Californians_go_home 7 месяцев назад
I always take a popsicle with me.
@mononc420
@mononc420 Год назад
What’s the reasoning for allowing 6 throws to disconnect a service? Why not just make it 1?
Далее
2023 230.85 Emergency Disconnect
15:19
Просмотров 8 тыс.
🛑 до конца!
00:12
Просмотров 112 тыс.
705.11 Connections to a Service
21:41
Просмотров 3,3 тыс.
750.30 Load Management
10:34
Просмотров 1,6 тыс.
Different Types of Disconnecting Means
21:14
Просмотров 34 тыс.
NEC requirements for box support (314.23)
16:45
Просмотров 19 тыс.
Isolated power (ungrounded) systems (NEC 517.160)
14:51
2020 NEC changes series: 110.14 Conductor Terminations
23:28
Article 230 Services
1:14:06
Просмотров 737
EICR FAIL- Maximum demand
19:07
Просмотров 77 тыс.