25 Electrical Exam Prep Questions with Full Explanations Volume 6 

Electrical Code Coach
Подписаться 63 тыс.
Просмотров 20 тыс.
50% 1

Опубликовано:

 

6 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 27   
@Theillest13
@Theillest13 2 года назад
🗣soak up everything this man is teaching, his kind is rare…he actually cares about the future of our profession. Remember study with purpose!! Much respect Code Coach !!
@ElectricalCodeCoach
@ElectricalCodeCoach 2 года назад
Let's go!!!
@Trill_Sparky
@Trill_Sparky Год назад
Which test questions fall under Branch circuit and Feeders, is just sizing conductor sizes and overcurrent questions , I just took my masters past Monday failed my calculations portion by one question. You’re videos are the best on RU-vid, i appreciate what you do.
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Keep grinding!! electricalexamcoach.com
@adelcamac8681
@adelcamac8681 Год назад
1 Año tiene el video y sigue enseñando . Muy bien!
@nelsonmontenegro9691
@nelsonmontenegro9691 2 года назад
on the motor short circuit / ground fault protection, the question about 7.5 HP 230v the calculations you mentioned was 40 x 8.00 = 350 I calculated 320? next size up would be 325 answer C. ? I'm not sure if I'm missing a step?
@ElectricalCodeCoach
@ElectricalCodeCoach 2 года назад
Great question. You head to 240.6(a) and select bthe next standard size it jumps from 300 to 350 there is no 325 standard.
@pjmcinnis1188
@pjmcinnis1188 2 года назад
Yes I was wondering the same, the math is just incorrect but breaker size correct
@ElectricalCodeCoach
@ElectricalCodeCoach 2 года назад
I see looks like I jumped ahead!!
@maliksherman83
@maliksherman83 2 года назад
When calculating the general lighting load, how come we still add the 4500 for small appliances and and laundry?
@AA-jn4ff
@AA-jn4ff 2 года назад
It is truly a blessing the information you supply! Thank you. Why is XHHW and THHW listed in both 75 c and 90 c?
@mcarroll598
@mcarroll598 Год назад
How do you know when to size up or down for breakers when sizing different breaker types for motors?
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Up on short circuit ground fault protection Down on overloads
@mcarroll598
@mcarroll598 Год назад
@@ElectricalCodeCoach thank you very much. And down on a feeder feeding multiple motors?
@mcarroll598
@mcarroll598 Год назад
@@ElectricalCodeCoach hey coach thanks, does this include all the breakers in the chart to go up?
@danlosada898
@danlosada898 2 года назад
@7:30 EGC total cubic for a box. How would you do the calculation under the 2014 NEC? Thank you!
@ElectricalCodeCoach
@ElectricalCodeCoach 2 года назад
Great question, you would use the exact same method!!
@JoeMama-gk6py
@JoeMama-gk6py Год назад
Thank you for your videos. But I have a question on the second question box fill calculations. Please feel free to correct me if I’m wrong but according to 314.16 (b) (4) each yolk would have a double volume allowance in accordance with table 314.16 (b). So going to the table , for example, the size of my conductor 12 in.³ is 2.25 so we were times that by two so for each yoke with 12 wire, running to it, we would count that as 5 in.³. So I came up with 48 answer A. Thank you
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
2.25 x 2 = 4.5
@michaelbongiovi111
@michaelbongiovi111 2 года назад
On the question at 23:14 of the video, it asks about using THHN, which only exists in the 90 degree C column of the ampacity table, so when you choose the final size based on 186.75 amps, shouldn't the answer come from the 90 degree column, which would be 2/0?
@ElectricalCodeCoach
@ElectricalCodeCoach 2 года назад
Great question, no you would select from the terminal size regardless.
@seanmason5535
@seanmason5535 2 года назад
When sizing over current protection for motors, I thought you are supposed to use the tables in 430.247, 248,249......and not the motor nameplate current
@ElectricalCodeCoach
@ElectricalCodeCoach 2 года назад
Motor- Short Circuit Ground Fault Protection-use the table FLC. Motor- Overload-use the Nameplate FLA.
@chriswithrow3107
@chriswithrow3107 Год назад
Is it possible to edit in "Standard Method" in red, as in your other videos, for the questions at 24:56 and 28:26?
@Andrew-mz8tc
@Andrew-mz8tc Год назад
24:10 we just gonna let it slide that b was really 2/0 :P. i was pressed when i found my answer and it wasn't up there only for him to come up with the same answer and just the answer options lol
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Lol got to keep you on your toes!!
@joejoe6949
@joejoe6949 2 года назад
The first question i got it right and i did not have to look it up. That how good i I’m. Experience.