El peor inversor que se pueda comprar en un mes ya llevo tres veces que viene el técnico a programar ☠️, si no le pones el módulo de internet tendrás problemas con la sincronización de la bateria. Compre otras marcas me lo agradecerán 🙏
My 4048 resets whenever it runs a load over 2,000 watts. The cooling fan kicks on after 10 minutes, but it causes the system to shut off for a couple seconds, which cause all my electrical appliances to turn off, and then turn on after about 5 seconds.
I am getting a LOW VOLTAGE WARNING . I have 8 RENOGY 12v 200 ah gel batteries which I checked and are better that ok. I got AN OUTBACK FLEX 80. When I turn off the inverter the voltage come back up, but if it ON BUT STILL NOT USED voltage goes down. Can anyone please help_
As I said before , I have 8 12v 200 ah batteries. I only want to fill go 95% as its full charge (56.8v). How do I set that up on my Context sx Schneider 4048 inverter? I also don't want it to go below 52.6 which would roughly be a 50%. How to I set this up. Go easy on me I am truly a rookie in this. Thanks
Hi...I have 2 mppt Schneider with a 6848 pro, both with 9 PV 330W ...they are configured primary and slave, but I have noticed that they do not both produce the same...the primary is always lower in production that the slave....do you know what my problem is?...thanks
When my generator kicks in to support the inverter and batteries, my power kicks off for split second, I loose all power for a second or so. Everything has to reboot. I have A SW4048, 48 volt setup, AGS, and solar panels, and Conex Combox to make any changes. Is there a setting I need to focus on? Appreciate any help in this area!
Good morning Eric I have worked on a lot of sw Inverters and have seen this problem a few times , there is a few things it can be , what size of genset are you using ? what is the voltage and HZ settings that you programed in the SW ? I have seen that if the AC settings are open to big 90 to 138 volts 54 to 70 HZ it can be a problem try 100 to 138 55 to 65 hz maybe that will help ,
Two questions. How is the Batt capacity determined? I have 8 12 v 200 AH Lithium batteries which will replace 8 12 v 200 Ah gel batteries. Whta is the voltage on this context 4048 , is it 24 or 48 volts?
1st question Battery Amp hour is battery is 200Ahr times voltage of the string or system so 200ahr times bat voltage of 48 volts is 9600 watts or 9.6kwh Or another way is 200 amphour at 48 volts.
Where do you connect your generator feed wire to the system? As well my generator is a Generac 13kw is there any special settings that need to be set? Thanks
You need a two pole 50 amp breaker that ties into the inverter well if you need a Schneider AGS controller and yes there are special settings for it there's exercise time runtime voltage high voltage low crank time for the generator limit output for generator if you don't use that you'll roast a generator and a GS controller will tie into the Generac start circuit diesel generator glow plug delay hand crank using the remote software package is in it where you at lot easier to go figure out all of this runs on their canbus
Hello Nice video, I whould like to know what whould happen if I change the configuration of the stage inverter to 2 stages without flooding, I saw another video and recommended this configuration for better performance in the inverter, the change will be only in the inverter ,what do you think? Best regard Gilberto
Yes you could change to a three stage setting. As the genset is / should be used as backup for when you have low solar energy. Using the genset to float would be a waste of fuel
Thank you, Gilberto! For more info on this setup, please give our shop a call at (403)-358-7762 or email at sales@cbisolar.com, one of our professionals would be happy to assist you!
Hi can you explain ac support feature I want to use enphase inverters in an ac couple scenario and only use my sw as a grid backup outage scenario and rest of the time have it push out to the grid
Hi plojm123, Thank you for the comment! If you would like, give our shop a call at (403)358-7762 and one of our professionals can assist you with this.
@@earthenergyhex Well i need to Reply kinda carefully because the SW inverter has a few problems and that is the AC support Load Shave and SOC this you can learn on your own but if you live off grid i set them all to DISABLED .