Тёмный

31 year old Heat Pump Copeland scroll cut open & inspected. 

Love2HVAC with Ty Branaman
Подписаться 51 тыс.
Просмотров 9 тыс.
50% 1

What does the inside of a 31 year old compressor look like after running all year around in a heat pump application? well lets take a look inside!
This Carrier Heat pump was manufactured the 6th week of 1992 with the original Copland Scroll compressor and even the original filter drier.
This compressor was still running strong and was replaced due to a leaking evaporator coil, and expensive R22 refrigerant, the age and rust on the compressor and accumulator.
As we look inside the compressor was in really good shape. It ran hot at one time, likely due to the leaking evaporator coil and it had refrigerant foodbank at one time either dirty filter, dirty coil or being overcharged to get a little more life out of it.
Follow along as we cut it open and inspect all the parts.

Опубликовано:

 

6 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 46   
@user-vb4xf7ov7s
@user-vb4xf7ov7s 11 месяцев назад
Outstanding video! Ive been in the hvac business for 35 years and have rarely seen such a knowledgeable autopsy of a compressor. 31 years is a good run
@languagejourney6906
@languagejourney6906 10 месяцев назад
Awesome video first time i’ve den a video where someone shows that part of how the scroll Compressor lubricates makes a lot more sense seeing it then just explained
@elgkas9928
@elgkas9928 11 месяцев назад
Great video. Very informative and interesting to see the internals.
@love2hvac
@love2hvac 11 месяцев назад
Thanks!
@repairitdontwreckit4257
@repairitdontwreckit4257 11 месяцев назад
Excellent video. Your explanation of how things we’re wearing was easy to understand. Overall based on the age it didn’t look to bad. Thanks. Roger
@love2hvac
@love2hvac 11 месяцев назад
Thanks, yes inside things looked really great, decently had a lot of life left in it and all the wear was external, car on and overheat=low on charge. Bearing wear from floodback=low superheat, (airflow, over charge overfeeding metering device) Copper plating=improper dehydration=acid=eats copper away from the system. Imagine how long the compressors would last if: We installed them correctly, Maintained correctly, And did not have to change refrigerants.
@repairitdontwreckit4257
@repairitdontwreckit4257 11 месяцев назад
No kidding. Seeing the interior components and the damage related to superheat, low oil and other issue creates takes the mystery out of the gauge readings and why they are so important. Thanks again. Roger
@StopTheBurn
@StopTheBurn 10 месяцев назад
This thing ran 31 years!? Great manufacturing I would say. I hope the new ones are built as well. 😅
@mikafoxx2717
@mikafoxx2717 Месяц назад
And a good install! No water, no air, no oxidation, no leaks.
@victor.mnoriega3586
@victor.mnoriega3586 11 месяцев назад
I like the way teach thank you
@love2hvac
@love2hvac 11 месяцев назад
Thank you!
@robertcounts5300
@robertcounts5300 11 месяцев назад
I have never seen a 31 year old HP with the original compressor, seen a lot fail at 10 to 15 years. I have 35 years in the field running service.
@love2hvac
@love2hvac 11 месяцев назад
We need to do better at installing, Proper dehydration methods, Proper suction piping, Proper airflow, Proper charging. Next comes proper servicing. The 15 minute vacuum, suction looks good, had anometers, and beer can charging doesn't cut it. A good service tech and maintenance can't overcome a bad install. Some installs even look good but without proper vacuum,. It will never see it's potential. Compressors do not die, they are murdered.
@MikeB9771
@MikeB9771 11 месяцев назад
As always , awesome video Ty
@love2hvac
@love2hvac 11 месяцев назад
Thanks Mike!
@Mikecianfrocco
@Mikecianfrocco 11 месяцев назад
Amazing video bro!!!!
@love2hvac
@love2hvac 11 месяцев назад
Thanks Mike!
@MinnesotaHvAc
@MinnesotaHvAc 11 месяцев назад
GREAT video!!! There is on thing I didn’t see why can’t I pull a vacuum at times through a scroll. I tap the top and it will drop to sub 500 micron and then back up to 1000 microns. Then on my third attempt we head a clunk in the compressor and boom 293 microns with a 20 minute decay to 498 microns. What is happening in 2023 compressors. I do have 2 pallets of failed warranty compressors sitting there. Maybe it time to grab the go pro. Maybe it time to think about some content on my old channel.
@love2hvac
@love2hvac 11 месяцев назад
What brand of compressor was that?
@deanmartin1966
@deanmartin1966 11 месяцев назад
Ty your wife is going to be mad that you used her Pyrex measuring cup. Lol. Good video
@love2hvac
@love2hvac 11 месяцев назад
Shhhhhhhhh 🤫 she does not know, and nobody should tell her!!!!
@michaelszczys8316
@michaelszczys8316 11 месяцев назад
How do you they're not his? Pyrex cups aren't just for kitchens.
@deanmartin1966
@deanmartin1966 11 месяцев назад
@@love2hvac lol
@deanmartin1966
@deanmartin1966 11 месяцев назад
@@michaelszczys8316 true. Lol
@haithamwajeeh
@haithamwajeeh 11 месяцев назад
This is very wonderful and an excellent explanation... We want a clarification and explanation about the suction line heat exchanger SLHE, Trane innovation in heat pump chiller.
@love2hvac
@love2hvac 10 месяцев назад
The idea is to use the suction gas to sensibly cool the liquid refrigerant aka add subcooling, this reduces the amount of flash gas after the metering device. On the suction side, the warmer liquid passing on one side of the heat exchanger helps ensure all the liquid refrigerant is boiled to a vapor in the suction side of the heat exchanger before entering the compressor.
@patmcbride9853
@patmcbride9853 11 месяцев назад
If only the SEER2 compressors would last that long.
@love2hvac
@love2hvac 10 месяцев назад
No difference in the compressor of SEER1 vs 2. Seer to really just requires manufactures to use static pressure to simulate ductwork.
@philiphusain3923
@philiphusain3923 9 месяцев назад
What’s your opinion about adding thermal protection to the compressor discharge line ? Thanks
@samersarah957
@samersarah957 11 месяцев назад
Thank you for all what you to do Ty! If a big leak happened and lots of oil was lost what is the right way to measure and add it?🌷Thank you.
@love2hvac
@love2hvac 11 месяцев назад
Good question, no easy way on a resi system, there is no oil sight glass like commercial. You can compare suction superheat to discharge superheat. If they get too far apart it's a good sign it's low. However the only way to really know is to drain and measure.
@Dicofol1
@Dicofol1 11 месяцев назад
@@love2hvac Can you add a sight glass on Resi system ?
@love2hvac
@love2hvac 11 месяцев назад
@@Dicofol1 for refrigerant yes, for oil no.
@chrisscott1547
@chrisscott1547 2 месяца назад
Most people pronounce galling "golling" or "gaulling."
@DerSchrottBastler
@DerSchrottBastler 11 месяцев назад
it seems to me: back in the days, they could build things to last. how long modern compressors work? 10? 15? 20 years? under "optimal" conditions? a few questions: is the oil the original oil from 1992 or was it replaced, when yes, when it got replaced? im a little bit curiouse.
@love2hvac
@love2hvac 11 месяцев назад
Original oil. Refrigerant oil does not wear out, it can get contaminated with improper vacuum or taking hoses in and off introducing moisture. It can get birt form overheating such as a leak, low suction pressure, high superheat, high suction gas temperature. The discharge line should never exceed 225. A car engine has massive heat, blow by from combustion, left. Over carbon from air and fuel. A Refrigeration compressor does not have any of that. Copeland still builds these scrolls the same way but they have added some protection such as a thermal operating disk, pressure relief valve, and anti reverse rotation valve. They are still made here in the USA in Sydney Ohio. They built and test them for 100% to be operating at least 20 years. Due to improper installation and maintenance is the reason for shorter life. There is nothing to wear out and fewer moving parts than a reciprocating compressor. The biggest issues today are improper installation, and leaking evaporator coils.
@8joh58
@8joh58 10 месяцев назад
Hi I have always wondered if the Nitrogen flows through the compressor when brazing it in? Can u please answer the question it’s very important to me thanks
@love2hvac
@love2hvac 10 месяцев назад
It won't flow through the compressor but it will greatly reduce the amount of oxygen and greatly reduce the oxidation effect.
@8joh58
@8joh58 9 месяцев назад
Why it won’t? Because only 3psi? What about if pressurized the system? Does flow through compressor 🙏 please explain, u r very knowledgeable , I watch one of your video said it’s does flow through that’s why I am confusing thanks
@8joh58
@8joh58 9 месяцев назад
Please explain thanks
@love2hvac
@love2hvac 9 месяцев назад
@@8joh58 excuse the compressor will not allow anything to move through it without it operating. When a compressor shuts off, it holds high pressure on one side. The pressures won't equalize until it bleeds through the metering device. The compressor has check valves in place to prevent the high side from bleeding back and the low side cannot move the compressor and motor to get to the high side.
@8joh58
@8joh58 9 месяцев назад
So which means nitrogen never flow through the compressor when brazing it in, even if u flow nitrogen pressurized the system with 300 psi-350psi? But when system empty out the refrigerant, there isn’t pressure inside the system, nitrogen still can’t flow through compressor? Please 🙏
@WallaceRoseVincent
@WallaceRoseVincent 4 месяца назад
Your wife is going to kill you if she finds out you poured refrigerate oil in the measuring cup.
Далее
Heat Pump 12 Hight Pressure trips only in Heating
12:51
Heat Pump 03 Reversing valve
21:04
Просмотров 32 тыс.
Я ж идеальный?😂
00:32
Просмотров 73 тыс.
COPELAND SCROLL COMPRESSOR TEAR DOWN
19:38
Просмотров 37 тыс.
Copeland Scroll Compressor Teardown
7:03
Просмотров 64 тыс.
Rate my Scroll Compressor Install (1-10)
9:25
Просмотров 4,6 тыс.
Cut open scroll compressor running.
20:46
Просмотров 215 тыс.
Heat Pump 06 Fixed orifice metering device
11:11
Просмотров 12 тыс.
I HATE Mitsubishi MiniSplits
15:41
Просмотров 131 тыс.
Scroll Compressor Autopsy
30:54
Просмотров 125 тыс.
Professional Heat Pump Maintenance
4:42
Просмотров 192 тыс.
HVAC 074 B Scroll compressor cut open
8:26
Просмотров 28 тыс.