400 AMP Underground Meter Replacement JCPL | Mantoloking, N.J. 

Electrician Ron
Подписаться 25 тыс.
Просмотров 7 тыс.
50% 1

In this video an underground electrical service utility meter enclosure is replaced. JCPL had come out to disconnect the power early in the morning and returned after the work was inspected to re-energize the service.
Electrical Wiring is NOT a hobby. Call a licensed electrician!
Classic Electric, LLC | Point Pleasant, New Jersey
License & Business # 16557
(732)-770-1437
Want to be an electrician? Start here: www.myelectric...
Ron Pecina Jr. is a licensed electrician in the state of New Jersey since 2009.
This allows him to apply for electrical permits, work with live conductors, remove meters, and disconnect service from the utility company.
New Jersey observes the 2020 NEC and the Uniform Construction Code.
The majority of the work you’ll see on my channel falls under the New Jersey Rehabilitation Sub Code (Chapter 6 of the U.C.C.) www.nj.gov/dca...
ALL New Jersey licensed electricians MUST complete 34-hours of continuing education units each tricentennial period.
This includes a mandatory 9-hour code update course and (1) hour business law class.
Any work above 10-volts requires an electrical license in New Jersey.
Ron is an active member of the New Jersey Independent Electrical Contractors Association.
Become an NJ-IEC member here: www.nj-iec.org
IEC National: www.ieci.org
Customer Guide for Electrical Installation; JCPL: www.firstenerg...
Customer Guide for Electrical Installation; PSEG: nj.pseg.com/bu...
WANT TO SEE MORE? FULL 200 AMP SERVICE UPGRADE. WATCH HERE: • RU-vid Subscriber in ...
Classic Electric, LLC is a Generac standby air-cooled generator installer. Generac Dealer # 1019500
Ron Pecina Jr’s set up:
Camera: Go Pro 9/ 10 w/ the Media Mod
Microphone: DJI Wireless
Editing software: Apple iMovie
Animation software: Apple Keynote
Background Music & Sound Effects by Soundstripe.com
Like, Share, and Subscribe!

Опубликовано:

 

15 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 60   
@seaneyo2006
@seaneyo2006 6 месяцев назад
Service looks good! Just curious why you wouldn't use a polaris connector instead of the split bolts?
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
Supplier didn’t have that size is what I was told.
@bigtroll8249
@bigtroll8249 6 месяцев назад
I was gonna ask this same question but I saw you asked firsr😊
@tmitch4976
@tmitch4976 6 месяцев назад
Nice job Ron.To bad you didn't have any hy-press sleeves
@BartlettTFD
@BartlettTFD 6 месяцев назад
Great job and video! Having to extend those cables by a couple of inches or so definitely added to the pain-in-the-ass part of the job. Appreciate your workmanship.
@chuckq54
@chuckq54 6 месяцев назад
Sweet job Ron. It’s always something isn’t it? Hope you and your family had a great Easter 👍👍
@FrontRowOrBust
@FrontRowOrBust 6 месяцев назад
Ron, you just made Easter a tad bit better🎉
@imbowser
@imbowser 6 месяцев назад
hey ron, i tried to run a new outlet based on one of your videos. i must have done something wrong since i roasted my chestnuts. will try again soon once i recover. thanks for your videos
@jeffmoss26
@jeffmoss26 5 месяцев назад
We have first energy (the illuminating company) here in Cleveland. Nice work!
@electricianron_New_Jersey
@electricianron_New_Jersey 5 месяцев назад
All utility comps are pains in the ass.
@BigD63
@BigD63 6 месяцев назад
Thanks Ron for the video. Looking forward for the next. Best regards from Chicago...
@estevaness
@estevaness 6 месяцев назад
Nice video, watched your other video prior to this one when you did it Hot, I believe our poco would have to de energize underground service conductors or just tape em since now we’re in the 2020 cycle and now required an emergency disconnect.
@vince6829
@vince6829 6 месяцев назад
Nice job as always. Thanks for sharing your knowledge.
@zekenzy6486
@zekenzy6486 5 месяцев назад
Great Video. Good Job and Nice Work. Thank you for sharing
@electricianron_New_Jersey
@electricianron_New_Jersey 5 месяцев назад
Thanks for watching!
@johnwalker890
@johnwalker890 6 месяцев назад
Good job Ron, Happy Easter to you and your family.
@wirewaykingelectric4978
@wirewaykingelectric4978 6 месяцев назад
Have you ever used Burndy barrel crimps with a crimper and heat shrinks or a insulated Polaris taps Isco and T&B make them, most supply house sell them little caps on them and they sell thin in one side out the other side
@BackwoodsLaw
@BackwoodsLaw 6 месяцев назад
Always hated seeing those 400 amp boxes when we were pulling up on a house fire. Never had a main disconnect we could get at without opening the boxes; that is changing now, but it was always fun picking who was going to secure the utilities when I was working... 😅 I am doing my home panel in the house we moved in to 3 years ago, from the early 70's on Wednesday. Putting up a new panel and getting the ground bonding fixed, it is a mess right now. The current box is a Bryant 12 slot filled like a birds nest, and have 5 breakers double tapped. Still don't understand how those kinds of boxes make it past the home inspector's all the time... Putting in a SquareD 20 slot 40 Circuit so I can sleep at night. 😁
@engineeringpunk
@engineeringpunk 6 месяцев назад
Check out the Ilsco PBT line. They're priced way more competitively than Polaris ITG. We only use split bolts for uninsulated splices anymore.
@OnusofStrife
@OnusofStrife 6 месяцев назад
Funny how different utilities are. Here in CT eversource lets licensed electricians disconnect services. Now if you have a home owner permit they require an inspection sign off before they will reconnect. But that is not the case for electricians as per their manual.
@zoraaduntov2290
@zoraaduntov2290 5 месяцев назад
Great Video and great Job as usual!
@electricianron_New_Jersey
@electricianron_New_Jersey 5 месяцев назад
Thanks again!
@BearStar1
@BearStar1 6 месяцев назад
Wondering WHY you didn't use Polaris Connectors instead of using Split Bolt Connectors for splicing or tapping those Service Line Conductors for the extra length rerquired to reconnect to the Line side lugs of the New Meter Can ???
@jessesmith1681
@jessesmith1681 6 месяцев назад
We aren’t allowed to use split bolts in most areas around here on services . I don’t personally like them myself and won’t use anyways . Here we aren’t allowed to disconnect or reconnect utility side of power whether overhead or underground . Power company must do and will not reconnect without inspector signing off and emailing approval . Sometimes though it takes a day or two for reconnect depending on what time they receive approval and how busy their crews are.
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
So you leave homeowners without power? That’s great service.
@jessesmith1681
@jessesmith1681 6 месяцев назад
@@electricianron_New_Jersey it’s not the contractors choice unfortunately . We let the homeowner know that it is a possibility that power won’t be back on for a day or so so they can make arrangements. I also have a portable generator that I use sometimes if they don’t have anywhere to go . The utility company tries to get power on as quick as possible but it’s out of the contractors hands once we complete the job . We can be fined if we tamper even with the meter although I have pulled a few in an emergency and they haven’t said anything
@kenbrashear210
@kenbrashear210 6 месяцев назад
How big of a hassle (and cost) would it have been for JCPL to run new conductors so you wouldn't have to add extensions? The lugs you used for the extensions took up a lot of space.
@franko_ge
@franko_ge 6 месяцев назад
Was there an option or consider lowering the enclosure just 2 inches, cut the conduit?
@ninjip3460
@ninjip3460 6 месяцев назад
Thanks Ron for such an informative video. Qq, I’m planning to install heat pump for 5 ton unit and need to increase JCPL input, how do I it and how much it could cost?
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
Just call them. You’ll have answer in about 8-9 months from now. Good luck!
@ninjip3460
@ninjip3460 6 месяцев назад
@@electricianron_New_Jersey oh that doesn't sound good, thanks for your inputs.
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
@@ninjip3460 first energy is horrible. Good luck.
@Bob.W.
@Bob.W. 6 месяцев назад
Thanks.
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
You're welcome!
@jalexlivi
@jalexlivi 6 месяцев назад
Rock solid as always,sir.
@GeorgeProto-u1e
@GeorgeProto-u1e 5 месяцев назад
Nice job
@johnmazzocchi7116
@johnmazzocchi7116 6 месяцев назад
Hi Ron, hope you had a great Easter with you and the family! Are you allowed to use Polaris connectors in a situation like this?
@thomassemich4627
@thomassemich4627 6 месяцев назад
Thank you, Ron, good job as always! If you don’t mind me asking, what tape or tapes, did you use on your split bolts?
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
Rubber Scotch 33 and then vinyl tape over that.
@scifycartoon
@scifycartoon 6 месяцев назад
i didn't know a 400 amp meter existed. thoughth 400 amps had to go through CT's
@bbol745
@bbol745 6 месяцев назад
Happy Easter! 400 amps! What do they have to even come close to that? My house has 100 amp service and we don’t even come close to needing more and that is while also powering an RV. That being said all our big appliances use natural gas for their heating elements and we drive ICE vehicles.
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
4 zones of heating and cooling.
@Californians_go_home
@Californians_go_home 6 месяцев назад
Most homes over 3500 square feet are going to need 320
@nickk05281982
@nickk05281982 6 месяцев назад
wow what are they going to do to protect the new meter socket thatthe meter is mounted? do jcpl allow that extension and connections inside the socket? our area does not incase there is more settling of the ground
@nickk05281982
@nickk05281982 6 месяцев назад
crew job big down and do a horizontal splice underground to extend
@tacticaltal
@tacticaltal 6 месяцев назад
Where is the video you mentioned on the underground service?
@takearidewithme3589
@takearidewithme3589 6 месяцев назад
In our jurisdiction the utility will not let us extend the line side conductors, no taps or extensions allowed. We also can’t cross their conductors with the load side conductors.
@Cole-dv2pt
@Cole-dv2pt 6 месяцев назад
Another good video as always 👍
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
Thank you! Glad you enjoy the videos.
@wirenut9062
@wirenut9062 3 месяца назад
Orange & Rockland utility has to have the inspection and cut in card before noon to re energize the same day. Joke
@electricianron_New_Jersey
@electricianron_New_Jersey 3 месяца назад
@@wirenut9062 pain in the ass right!?
@ElectroAtletico
@ElectroAtletico 6 месяцев назад
Fun vid
@billdee814
@billdee814 5 месяцев назад
If this is a residential home with one meter why do they need 400 amps?
@electricianron_New_Jersey
@electricianron_New_Jersey 5 месяцев назад
For electrical appliances
@350FMC
@350FMC 6 месяцев назад
Load side 500 copper?
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
Or 400. The line side are 350 aluminum. Good for 250 amps and there’s very little open air since it’s underground conductors. Smh.
@nspro931
@nspro931 6 месяцев назад
Big surprise, brand x generator fails to start, good for you I guess.
@steveg5576
@steveg5576 6 месяцев назад
3.5 hrs at the site......4.0 hrs look at the job, mobilization, other crap you went over.
@MC-ig8cm
@MC-ig8cm 6 месяцев назад
First Energy is definitely in Ohio and they suck
@electricianron_New_Jersey
@electricianron_New_Jersey 6 месяцев назад
Brutal. 🫵
Далее
When Khabib dropped Conor McGregor 👀 #nocommentary
00:59
НЮША РОЖАЕТ?
00:17
Просмотров 1,1 млн
Mast and weather head training
9:24
Просмотров 45 тыс.
Overhead & Underground Electrical Utility Service
15:52