A Simple Trick To See If Your Heat Exchanger Is Cracked. 

The DIY HVAC Guy
Подписаться 311 тыс.
Просмотров 380 тыс.
50% 1

EVERY HOME should have multiple CO detectors as an extra layer of precaution. Here is the one I recommend: amzn.to/40Asfcw
Long matches: amzn.to/3QVlZcd
Long lighter: amzn.to/49yLvLr
America's #1 Choice For Quality, Affordable HVAC Equipment: www.alpinehome...
IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a low price of $200, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: / diy_hvac_guy
Tiktok: www.tiktok.com...
Facebook: / selfmadehvac
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.
Jobber: The #1 operations management software for home service businesses - Free 14-day trial + Exclusive discount: go.getjobber.c...

Опубликовано:

 

21 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 588   
@InternetDude
@InternetDude 10 месяцев назад
We need more honest folks like you!!!
@fuzzypickle5307
@fuzzypickle5307 10 месяцев назад
He has good intentions, but his advice is dangerously ignorant. He portrays a cracked heat exchanger as a minor issue, and likely a scam. People die every year from cracked exchangers, and many more suffer irreperable damage from CO poisoning. This is a neat trick, and we use similar observations during testing, but you need a combustion analysis and a CO report to know for sure. Be wary of this guys advice on this matter.
@masterdirk101
@masterdirk101 10 месяцев назад
"honest folks" don't tell people cracks in their heat exchanger are fine if they are small. Small cracks get bigger when the heat exchanger heats up and causes metal to expand.
@percyfaith11
@percyfaith11 10 месяцев назад
@@masterdirk101 How do "honest folks" know that the heat exchanger has small cracks if they don't take it completely out of the furnace and inspect it? They can't. They just make up false tales about cracked heat exchangers to sell expensive new systems.
@Watchyn_Yarwood
@Watchyn_Yarwood 10 месяцев назад
Amen!
@masterdirk101
@masterdirk101 10 месяцев назад
@@percyfaith11 The same way techs do, by inspecting it in place with a couple of cameras or mirrors? I've never condemned a heat exchanger for a crack that the homeowner themselves couldn't also verify. I also take videos starting with looking at the furnace itself which cuts all doubt. that its just some saved picture. Either way, this is a poor test to determine a heat exchangers integrity, as I've said the small cracks expand when the heat is on, so a test on a cold heat exchanger might not say much. Even immediately after cool down. I give credit to his point, people are out there trying to scam you and get you to buy a new system, its a fact of life, the problem is people are going to do this test and think their furnace is safe to run while they have a CO monitor from the early 2000's plugged into an outlet somewhere.
@jim9337
@jim9337 10 месяцев назад
As a former gas fitter I was glad to see you putting out good info so folks don't get scammed.
@UQRXD
@UQRXD 10 месяцев назад
Correct me if wrong. But you did test on a cold heat exchanger. Small cracks some times seal when cold and expand when hot. Always have detectors. More than 1 they can fail too. Life is priceless. In fact the furnace should be interfaced with one to shut it down. But manufacture liability may be to much for that. I am always amazed that homes with gas lines don't have auto shut offs with a gas fume sensor. Many an explosion could be avoided. After all the electrical system has fuses and breakers.🧐
@tedevans2095
@tedevans2095 10 месяцев назад
As a Senior appliance technician, I just gained valuable knowledge that will be very helpful for me. This young man takes his work seriously. I wish that there were more people like him. Thank you 😊
@patrickmccuiston7762
@patrickmccuiston7762 7 месяцев назад
25 Years in the trade here, your video is everything a technician needs to know. Well Done.😊
@stevenmachnick9613
@stevenmachnick9613 6 дней назад
You need to be retrained
@74ace468
@74ace468 10 месяцев назад
I use an incense stick for all kinds of similar draft and air leakage tests. Works great lasts a long time.
@edlauren9434
@edlauren9434 9 месяцев назад
Outstanding explanation!!!!! Thank you man! I am a licensed hvac/refrigeration contractor. Will be sending this video to my customers! It’s the best and easy to understand video about heat exchanger issues that I’ve seen! Thank you!
@Ratlins9
@Ratlins9 10 месяцев назад
I got ripped when my my ac unit developed a leak and was told it just needed to be recharged. I vowed to educate myself to not let that happen again. Thank you for your educational videos.
@primusheating1
@primusheating1 10 месяцев назад
It's just like a car tire losing air consistently. You have a leak in that tire. The same goes for leaking refrigerant.
@Ratlins9
@Ratlins9 10 месяцев назад
@@primusheating1 Thanks primusheating1, being ignorant, I took the technician at his word until a few months later the same problem occurred. This time I researched it only to find out refrigerant doesn’t go bad but can leak. Called another company who quickly determined it was a leak. Appreciate your comment.
@paulrozinski1488
@paulrozinski1488 10 месяцев назад
The same happened to me about 10 years ago. The thief charged me $10 PER OUNCE and put in almost 6 POUNDS of R410A . Never again !!! Knowledge IS power.
@tg-bh2up
@tg-bh2up 10 месяцев назад
How did you get ripped? was the leak large enough that you think the A coil, refrigerant lines, or entire unit should have been replaced and you now will be constantly recharging until then? Or is the leak rate small enough that it might be several years before needing a refrigerant top off?
@joeschleprock3409
@joeschleprock3409 10 месяцев назад
Same thing happened to me.Buhler Mechanical in thunder bay ripped me off.
@wilsongonzalez8753
@wilsongonzalez8753 9 месяцев назад
Well explained and well done. You should it be a teacher because you take the time and I can see your devotion. Keep up the good work. Professor WG, US Army Retired/Disabled Veteran from Pennsylvania.
@richtech22602
@richtech22602 9 месяцев назад
It might be worth noting that this should be checked with both a “hot” and “cold” exchanger as sometimes if there is a crack in it, once the exchanger warms up, the metal expands slightly.
@kennethkline7702
@kennethkline7702 9 месяцев назад
Do you actually know what you're talking about? Or are you just saying this as a concept?
@JesusSaves71185
@JesusSaves71185 9 месяцев назад
@@kennethkline7702he actually knows what he’s talking about. It’s simple physics. Use google next time before posting a comment.
@raccoon874
@raccoon874 8 месяцев назад
*All three commenters above have IDs that end in 02. Strange.*
@KennethCherisol
@KennethCherisol 8 месяцев назад
​@@raccoon874 Possible bot activity or someone in Desperate need of attention. Lol
@topher8634
@topher8634 8 месяцев назад
It's a conspiracy.
@lisanelson4750
@lisanelson4750 9 месяцев назад
Thank you for putting up this video! I was nearly scammed years ago by an HVAC guy who told me my furnace had a cracked heat exchanger. Even whipped out his "carbon monoxide detector" to show me the high numbers coming thru the vents. I asked him then why my multiple CO monitors all over in the house were not going off if there was life threatening levels - to which he shrugged off. Then he and his boss tried to pressure me into buying some off brand furnace replacement. Fortunately I had to get to work at the time, so put him off until I had a chance to arrange the finances. I then got a recommendation from a friend at work for a different HVAC guy to come out and look at it. He found that not only was there NOT a cracked exchanger, but that the previous HVAC guy had "booby trapped" my furnace by manually destroying the computer board so the furnace would not run at all now. The cost of replacing the computer board on the old girl was almost as much as a new furnace, so I had the new HVAC company replace it with a well known brand. Now I understand it better and will know how to check myself! Thanks!!
@Jon-hx7pe
@Jon-hx7pe 7 месяцев назад
co alarms have a high cut-off, not displaying anything below 30ppm. no co in doesn't mean heat exchanger isn't cracked.
@lisanelson4750
@lisanelson4750 7 месяцев назад
@@Jon-hx7pe The numbers he was showing me were all over 500 - well above the the cut-off and a life threatening situation - if true. The second HVAC guy who found the damaged computer board took multiple CO readings at the air vents - all were 0. People should ALWAYS get a HVAC second opinion when any repairman tells them the heat exchanger is cracked or leaking. CO is nothing to mess with!
@Jon-hx7pe
@Jon-hx7pe 7 месяцев назад
It is very possible that someone was trying to scam you. At the same time, people need to understand no co at vents does not mean the heat exchanger is fine. Only visual inspection can for sure confirm the heat exchanger has no cracks, holes, popped crimp rings. A combustion test including oxygen can tell if the heat exchanger is leaking badly, but can have a normal combustion test but it is still cracked. When a defect is found, the tech should be able to show it - second opinion not needed. if you have unsafe wiring, it is still unsafe whether or not the wiring is actively overheating and smoking. This guy's channel is terrible and he's basically trying to make it out like every hvac tech is an scam artist and there is nothing to this field, anyone can do it. Telling people to only buy crappy single stage mid efficiency furnaces too. There's some great stuff on youtube but not on this channel. @@lisanelson4750
@davidgleatham9966
@davidgleatham9966 10 месяцев назад
good follow through . watching the match burn fair after going back to an undamaged tube offers a very positive test. watching both flame sources got even better. i did hvac for many a year and never new of this test. great way to upcycle an old furnace- the leak demo
@rayzerot
@rayzerot 10 месяцев назад
Even easier- run the blower and stick your manometer in each tube. Any pressure change indicates airflow from your blower into your heat exchanger and proves there is a crack (of any size)
@6paxer
@6paxer 9 месяцев назад
How many homeowners have a manometer. You missed the point of this video.
@garynicholls72
@garynicholls72 9 месяцев назад
Hi Gary from the UK I am an old heating engineer and I haven't worked on hot air systems too much, just wanted to say Great video very interesting and informative keep them coming Very good tip thank you
@urielvargas6777
@urielvargas6777 10 месяцев назад
Man you are my hero, replaced my furnace following your tutorials, I am responsible for my actions but very thankful for all the info you share. -replaced. -built plenum (the old one was taller and slimmer) to connect to Acoil boxing. -tested gas pressure with the amazon white manometer you used in one video. -verified for days that carbon monoxide does not exist. With the klein tools that you use. All for less than 700 including flexible gas line, new gas valve, new filter. New furnace was 3 years old but never installed, I got it for 400. Cleaned it and it runs perfectly.
@diyhvacguy
@diyhvacguy 10 месяцев назад
Amazing. Thanks for sharing!!
@fuzzypickle5307
@fuzzypickle5307 10 месяцев назад
​@@diyhvacguyYou need to educate yourself about this subject before posting videos online that could actually get people killed. This is dangerously ignorant.
@natersalad889
@natersalad889 10 месяцев назад
​@fuzzypickle5307 it doesn't take a doctorate degree to work on hvac equipment safely and correctly....
@urielvargas6777
@urielvargas6777 10 месяцев назад
@@fuzzypickle5307 with all due respect he doesn’t tell anyone to do it. He shows how it is done, we are adults who understand the risks, and also follow thw safety tips and advice from @diyhvacguy. So all cool sr.
@troyroads8058
@troyroads8058 8 месяцев назад
Did you install the flex line into the furnace with a drip leg against icm code like this video?
@garmin1488
@garmin1488 9 месяцев назад
Great video, thanks. My furnace is 27 years old still working fine. I've replaced the igniter and the inducer motor twice. I have a new furnace sitting ready to go , bought it 5 yrs ago waiting for this one to go. lol bought it for $1250 Canadian they've doubled in price since then.
@LottimusMaximus
@LottimusMaximus 6 месяцев назад
This is a great way to do this. I usually use a combustion analyzer, but it’s hard to explain to customers there’s a problem. This helps visually.
@vernonlemoignan1392
@vernonlemoignan1392 10 месяцев назад
Great video. I have an 26 year old furnace in my home and plan on using it forever if possible. The new ones are expensive junk. I have a complete identical furnace for parts that worked fine when “upgraded “ a few years ago from a neighbor. I have co monitors but this test will help me make sure the old beast is still safe. Thanks!
@jonswisher8796
@jonswisher8796 9 месяцев назад
This is one way that MAY tell if you have a bad heat exchanger, but it only works if the hole is close enough to the flame to make it move. Certainly not the best way to tell. If you have an old furnace just get a cheap inspection camera and look at the heat exchanger. Easy, or follow safety advice from a rookie HVAC guy that retells stories he heard on the internet. Good luck, and yes, there is expensive junk out there but there is some very good equipment that will make your home much more comfortable than on old one ever could and will last a good 20 years if installed orrectly, but that’s not important to some people, so keep the old one going. I agree with that.
@chetmyers7041
@chetmyers7041 8 месяцев назад
@@jonswisher8796 My rental property has a Trane updraft furnace installed in 1990 that is still going strong, and on the original ignitor and draft motor.
@jonswisher8796
@jonswisher8796 8 месяцев назад
@@chetmyers7041 I just updated the old gas train on a 1954 Ward gravity because the elderly homeowner likes the heat and no fan. If it is installed correctly and maintained, most equipment can last a long time, if not, it will not last. Trane make s a good product, we work on them all.
@terrymeyer
@terrymeyer 10 месяцев назад
This is being done on a cold heat exchanger. A crack on a cold heat exchanger can be closed or sealed up but open up after it has been warmed up.Not saying this is a bad test just not a perfect test. If you have a bigger crack it will work real well., if it a smaller Crack that opens up more after it is warmed up it might not work as well.
@s.j.5850
@s.j.5850 3 месяца назад
You can do the same test after having warmed up the heat-exchanger.
@predatorishi
@predatorishi Месяц назад
My friend is HVAC contractor for commercial hospital buildings and I have been discussing HVAC troubleshooting since years though I am a software engineer, this information is sooo accurate! Thanks.
@kmbawdry
@kmbawdry Месяц назад
yup, I feel like I was 100% scammed last year. Wish I knew this info back then or at least had the idea to look into the claim that we had a cracked heat exchanger. Really appreciate the honest information you're providing here. Thank you DYI HVAC GUY 🙏
@Michael-uj4zw
@Michael-uj4zw 10 месяцев назад
Great demo, great service to the public! I was a heating/cooling guy for several years and we used to use smoke bombs which would cause a sulfur smell in the home immediately; this is much easier! Thanks again!
@rayzerot
@rayzerot 10 месяцев назад
Even easier- run the blower and stick your manometer in each tube. Any pressure change indicates airflow from your blower into your heat exchanger and proves there is a crack (of any size)
@stevefifield1207
@stevefifield1207 10 месяцев назад
Sure - but this was a simple test for homeowners, not needing any other tools than a match.@@rayzerot
@TheTruth10132
@TheTruth10132 8 месяцев назад
You are the best, fantastic explanation. I have seen HVAC companies are some of if not the worse on scamming consumers and not just cracks in the heat exchanger, but trying to sell a whole furnace because a fan going out (very easy to replace) or igniter, etc. Thanks again.
@s.j.5850
@s.j.5850 3 месяца назад
Great tip for checking for cracks/holes in the heat exchanger. It's a lot cheaper than an analyzer! This one I will pass on to my HVAC instructor.
@DoubleNDonn
@DoubleNDonn 9 месяцев назад
DTE (Detroit's Utility provider) came out to fix my furnace and ended up tagging it and locking it out because they said the heat exchanger was cracked. The furnace was over 30 years old so I just replaced it, luckily my neighbor used to install furnaces for DTE and replaced it at cost + a case of beer, my help and I donated to his grand daughters college fund😉
@PB-bb3di
@PB-bb3di 10 месяцев назад
EXCELLENT TEST , Perfect clear explanation of furnace heat exchanger and testing. The video is the best I have ever seen about furnace sequence of operation and proving crack with matches. Thank You!
@Mike-Olds-1
@Mike-Olds-1 10 месяцев назад
If my furnace wasn’t having any issues I would have kept it. The way so many things today are made a upgrade can just as easily be a downgrade
@gnic76
@gnic76 10 месяцев назад
That is how I see it as well, which is why I still have a 25 year old furnace that works fine. Plus an upgrade is a lot of $$$.
@natersalad889
@natersalad889 10 месяцев назад
Barely call it an upgrade, just newer equipment. Newer isn't always better, keep what you have
@natehirsh
@natehirsh 7 месяцев назад
Thank you very much for teaching me such a critical stage.
@mptr1783
@mptr1783 10 месяцев назад
My man, thank you very much. Im about to replace the gasket on my Goodman collector box cover which is leaking. I want to make sure the exchanger isnt damaged and will do this test first. Again, thank you very much!
@natersalad889
@natersalad889 10 месяцев назад
Great idea.... also having the ductwork attached on top of that furnace would add a little backpressure to help make the flames reaction increase with that slightly higher pressure coming in on a blower system thats not totally unrestricted at all
@Lenny8679205
@Lenny8679205 10 месяцев назад
I bet if he put a piece of plywood on top you would really a reaction.
@RWMorgan39
@RWMorgan39 10 месяцев назад
In the house, close all the supply's as good as possible to build up pressure
@willrefling6395
@willrefling6395 10 месяцев назад
Just saying, you don't actually have to build pressure for this to work. In most cases the flow through the coil is going to hit a reduced cross section. So you have an increased velocity. This will create lower static pressure than ambient. Which will still cause the flame to flutter. for example induced flues on old water heater. The density change from combustion flows up to an open air hood above the water heater. That high velocitiy creates a low static pressure zone which induces air flow from the room to carry the combustion products and the air from the room up the stack. Another example of this principle is fluid injectors.
@s.j.5850
@s.j.5850 3 месяца назад
@@willrefling6395 Sounds like an engineer's perspective. Appreciate the technical explanation.
@miketallman171
@miketallman171 10 месяцев назад
Very helpful hard to find honest people willing to help you not to get beat education is powerful even now someone comes to my home I will ask them to show me how he determined my heat exchanger was bad kudos to you my man kudos thanks
@donhauff4586
@donhauff4586 9 месяцев назад
Thanks for the tip. FYI - the 1998 date you pointed out is not the date of manufacturer. The date of manufacturer is the first four digits of the serial number in format MMYY. The 1998 date you pointed to is the date of the applicable code referenced there.
@madmax8620
@madmax8620 7 месяцев назад
My first four are 9104..... So what month is "91" exactly then??! (MMYY, according to you) Thanks Btw... it looks way older than from year 2004, looks like its from early 90s
@MiguelRdgz916
@MiguelRdgz916 7 месяцев назад
​@madmax8620 there are a few manufacturers that label their serial number different than the rest. I'm going to guess that you have a goodman or an amana system. So yours would be first 2 digits are the year then 3rd and 4th digits are the week that the system was manufactured
@madmax8620
@madmax8620 7 месяцев назад
@MiguelRdgz916 its a janitrol, and that would make sense, what you said. We (with the repair man) are having a real hard time figuring out why it is malfunctioning, and only short cycling. This is what we (he) did; Checked for flame rollout and flame tested for cracks in heat exchanger. Tested good. Cleaned the ignitor and flame sensor. Then Replaced Ignition board that allowed the flame sensor to be bypassed, and allowed the ignitor to be the sensor instead(a dual option sensor board ?)...THIS made the Furnace operate correctly, so we thougt the flame sensor was bad, and ordered a new replacement sensor. The repair man wanted his expensive board back, as it was a temporary loaner until the new flame sensor arrived. Installed the new sensor, wired the board appropriately, BUT THEN it continued to malfunction like before, intermittently ignighting, and or short cycling(with new board and sensor). Voltage/resistance tests were performed, but could not identify the problem. Any suggestions would be quite helpful at this point, as the repairman (a friend) is stumped now....???
@MiguelRdgz916
@MiguelRdgz916 7 месяцев назад
@@madmax8620 does the igniter come on? At what stage of startup is it short cycling
@MiguelRdgz916
@MiguelRdgz916 7 месяцев назад
@@madmax8620 oh and janitrol is made by goodman. It's almost like I know what I'm talking about 😂
@munozinni
@munozinni 9 месяцев назад
Hola señor DYI I was watching the video I just found today and I will watch the next videos that you recommended to watch after this one it’s amazing the knowledge that you have and the experience you have achieved working with hvac systems I will go to school in the future and I will enroll in this hvac 😊Saludos from Texas 👋😃👋you have a great day 😊
@BrentBlanchard
@BrentBlanchard 10 месяцев назад
It would be interesting to see the unit running with the hole in the heat exchange too. Great video overall, it's really helpful to know a way of checking the system myself.
@fuzzypickle5307
@fuzzypickle5307 10 месяцев назад
This is a neat trick, but dont rely on it. You need a combustion analysis and CO report before you can conclude that there are no cracks. This man is also dangerously ignorant about the dangers of CO poisoning. In his last video he stated you shouldnt be concerned about anything less than 100ppm of CO. At that level you will have irreversible damage. This guys advice about this subject is actually dangerous.
@caidhg
@caidhg 10 месяцев назад
little bit harsh don't you think, I'm sure he's aware of the dangers of Co poisoning, he never said you don't need a CO detector in your house if you do this. he's just showing you how to check if you have a failure in your heat exchanger which could save somebody a bunch of money just on diagnostic charges alone.
@Ratlins9
@Ratlins9 10 месяцев назад
@fuzzypickle5307 I saw that video and he stressed the importance of having a CO detector. Now regarding ppm of CO, the chart displayed in that video was acquired from Boiler and Machinery Engineering Bulletin, Federal Register, Vol 45 and Industrial Toxicology 3rd Edition. If you have a disagreement, take it up with them. Where are your videos helping homeowners from getting ripped off? I’ll wait for your response.
@BrentBlanchard
@BrentBlanchard 10 месяцев назад
Oh yeah, CO detectors on every floor. I meant checking as in if some tech says I have a cracked exchange and shows me pictures, there should be other signs besides a photo that may or may not be my system. Unfortunately there are some dishonest folks out there happy to replace perfectly good, working units.
@Thomas-xm5ym
@Thomas-xm5ym 10 месяцев назад
@@fuzzypickle5307…..aaannnddd that’s why no one likes you.
@videos10
@videos10 10 месяцев назад
This was a good demonstration, im a tech, and never knew the lighter technique.. your channel has GROWN TREMENDOUSLY! And in such a short period of time as well! Bravo!
@diyhvacguy
@diyhvacguy 10 месяцев назад
Thanks so much. It’s all because of awesome viewers like you! 🤘🏼🤘🏼 thanks for your support
@troyroads8058
@troyroads8058 8 месяцев назад
Could you imagine explaining to the judge that your not guilty of neglegent homicide of a family of 5 cause you used the "matches trick" you saw on you tube to ensure everyones safety......
@reaksmeymaranda2341
@reaksmeymaranda2341 4 месяца назад
This is unbelievable knowledge you’ve shared with us. Thank you.
@Icantfindtheanykey
@Icantfindtheanykey 10 месяцев назад
Great vid. Honest. Truthful. Helpful and simple. Thanks for educating us. Keep up the great work.
@SouthpawAutoworks
@SouthpawAutoworks 9 месяцев назад
Awesome info, man. Thank you for your ongoing contribution to this platform. -Robert (fellow content creator)
@gnic76
@gnic76 10 месяцев назад
Thanks HVAC Guy, that was an informative vid. An easy enough test to do periodically, to ensure furnace is functioning as it should. 👍
@fuzzypickle5307
@fuzzypickle5307 10 месяцев назад
Be wary of this guys advice. You need a combustion analysis and CO report to know for a fact that it is not cracked. If it is, you and your loved ones can die, or suffer irreversible damage from CO poisoning. This guy may have good intentions, but he is clearly not a professional.
@gnic76
@gnic76 10 месяцев назад
@@fuzzypickle5307 Is still nice to know how, if a home owner is concerned, after which, if in doubt it can be pursued further with a professional.
@charlescernosek
@charlescernosek 10 месяцев назад
If somebody told me this, I would ask them to leave. Even if your at 5 or 6 pm co it's a problem long term exposure is dangerous. Google it.
@natersalad889
@natersalad889 10 месяцев назад
​@fuzzypickle5307 just have carbon monoxide detectors through out the home like you should anyways, not rocket science
@doncollins786
@doncollins786 10 месяцев назад
Old HVAC guy here, video was very well done!
@geoffap0
@geoffap0 10 месяцев назад
Thank you, thank you, thank you! I hope more people find your videos! Stop the Ripoffs! You should be on Clark Howard’s show.
@timhenry3701
@timhenry3701 9 месяцев назад
I’ve been a service tech for over 20 years and while you are technically correct, it’s super dangerous to tell people cracks in their heat exchanger - minuscule or not - are not cause for concern. Liability issues are true issues.
@tgriebe
@tgriebe 10 месяцев назад
Great simple test. I have an older Carrier with the secondary heat exchanger issues and this is an easy test to make sure it is not leaking.
@fuzzypickle5307
@fuzzypickle5307 10 месяцев назад
This is not a conclusive test. You will need a combustion analysis and CO report to determine if there is a crack or not. If it is leaking and you miss it, it could kill you and your loved ones.
@bsintzel
@bsintzel 10 месяцев назад
Information is power. This info may save my bacon one day, so I'll add it to my tool chest. Much appreciated :)
@maxwellsmart3156
@maxwellsmart3156 10 месяцев назад
Excellent video, very thorough, and it's burned into my memory without any flickering. Knowledge is power and thanks for passing it on.
@drozcompany4132
@drozcompany4132 10 месяцев назад
Man that was a tiny hole. Wouldn't have thought that little of a hole would move the flame so much! Very informative!
@davkenrem
@davkenrem 3 месяца назад
I think I just got, got by an HVAC contractor for a cracked heat exchanger. I kept the old furnace and I am gonna do this test. Wish I,d seen this last week.
@hitekrednek66
@hitekrednek66 10 месяцев назад
OUTSTANDING INFORMATION SIR! This was such a good demonstration. I will be trying this on mine just to practice my newly acquired DIY knowledge (less the hole of course😂).Thanks for this information. Keep them coming sir!
@mikeoneal3550
@mikeoneal3550 10 месяцев назад
Great demo, great service to the public! I'm a heating/cooling guy for several years and this is much easier than taking everything apart. Thanks again!
@james6794
@james6794 10 месяцев назад
If you have a newer system with cooling I'd recommend pulling the disconnect for the condenser and putting it in cooling mode. some systems wont run the blower at full speed when only calling for fan. calling for cooling with the disconnect for the condenser pulled will give you full fan speed
@diyhvacguy
@diyhvacguy 10 месяцев назад
Great idea. Thanks for your input!
@MichaelwAEL
@MichaelwAEL 9 месяцев назад
Many thanks for all of your education. You are awesome in every regard. I am watching all of your videos. They are excellent. I wished you were my HVAC guy.
@unclejohn37
@unclejohn37 9 месяцев назад
I used to work as a Gas Tech. Moved to Alberta and HOLY!! the amount of crooked techs lying to customers is overwheming. I no longer work as a tech but for an entire winter I went and helped people. One lady was told her furnace was shot! $2800 to repair and she should just get a new for $4400. She was so stressed because it was xmas eve. I seen her ask online if anyone could get her a quote because she never had $4400. I said I would stop at her home on my way home from work FOR FREE to make sure they did not lie to her. I fixed her furnace for $110 and it still runs today a year later.
@diyhvacguy
@diyhvacguy 8 месяцев назад
The world needs more people like you sir
@lisaryder1668
@lisaryder1668 9 месяцев назад
That was an excellent video explaining how home owners can ck their unit . Much thanks to you for sharing your knowledge that's so very helpful. Blessing to you
@jimt7851
@jimt7851 8 месяцев назад
Brilliant video young Sir! One of the best videos on the subject. Thank you for taking the time to explain and show exactly the issue and what to look for. Keep them coming. Much appreciated.
@Tonyhvac
@Tonyhvac 8 месяцев назад
I appreciate this class brother,happy 2024 👍🏽💯
@BryanTorok
@BryanTorok 10 месяцев назад
This pretty much confirms something I've always thought. The draft inducer blower creates a low pressure inside the heat exchanger and the main blower (fan) creates a high pressure outside the heat exchanger. Air always flows from high pressure to lower pressure, so as long as both blowers are running, there is no way for combustion gases to leak out of the heat exchanger. In older less efficient furnaces that lacked a draft inducer blower, it was possible for CO to leak into the heated air stream. Still, CO and also smoke are nothing to be complacent about. 40-some years ago my then girl friend and her parents had a near miss with an older furnace with cracked heat exchanger dumping CO into the air. Another family that I knew of died because a bird nest blocked their chimney flue. Having smoke and CO detectors is a very good idea. Also, it is good to get a CO detector that displays the level even if that level is below the alarm level. Long term exposure to low levels of CO is also harmful.
@DCHVAC
@DCHVAC 10 месяцев назад
This isn’t true at all. The main blower will counteract the inducer and cause a flame rollout condition or turbulence pulls the exhaust fumes into the plenum.
@dcairns61
@dcairns61 9 месяцев назад
Great tip for a DIY check. I am very impressed on your one handed match lighting skills :D
@JohannnesBrahms
@JohannnesBrahms 10 месяцев назад
You can also put a carbon monoxide detector in front of a supply vent for a few weeks to see if there is a reading.
@RobertTuck-vo8cw
@RobertTuck-vo8cw 10 месяцев назад
The inducer fan creates a vacuum through the heat exchanger and pulls blower air in. The CO does not get into the room - Unless it is a huge leak.
@JohannnesBrahms
@JohannnesBrahms 10 месяцев назад
My inducer fan blows air into the combustion chamber and out the flue. In the other case, if there is no carbon monoxide being forced into the supply ducts, then it wouldn't be a hazard for the occupants. @@RobertTuck-vo8cw
@tedlahm5740
@tedlahm5740 9 месяцев назад
@@RobertTuck-vo8cwUnderstand your statement. Under this the INDUCER is actually pulling air form the ROOM air that is in circulation. thank you
@mapcelo
@mapcelo 7 месяцев назад
This explanation is perfect! Thank you very much!
@johnzhang3285
@johnzhang3285 10 месяцев назад
Great diagnostic!
@arth.4196
@arth.4196 10 месяцев назад
Thank you. It shows that Your Business Model is working. Much success.
@davidgentz1731
@davidgentz1731 9 месяцев назад
Good job I'm in the same field and that was a great presentation
@MrDmadness
@MrDmadness 10 месяцев назад
Ive used this method before. Its a good way to show a customer the issue
@davidgenie-ci5zl
@davidgenie-ci5zl 8 месяцев назад
I found out my heat exchangers was cracked when flames shot out the furnace louvers and ignited the nearby wall board. Fortunately I was at home, heard the smoke alarm and put the fire out. Furnace was about 55 years old. The replacement was nice, and shortly paid back the cost in reduced gas consumption.
@DanRussell-q8s
@DanRussell-q8s 10 месяцев назад
Great demo and will save you money and the potential of something bad happening !!
@tinysand3517
@tinysand3517 10 месяцев назад
We need more videos like this the HONEST DIY HVAC Guy
@LiuKang-tu8ub
@LiuKang-tu8ub 4 месяца назад
Well done! I will have to try this method. Thank you for sharing.
@larrybell4599
@larrybell4599 8 месяцев назад
Great demonstration. Thank you for sharing this and many other HVAC tips.
@philliplangley9302
@philliplangley9302 10 месяцев назад
Thanks, i am having problems with my furnace now blows cold air, I'm going to have a tech come out and look at it to see what the problem is, now I'm a little wiser on how the furnace works.
@jeffbova-im7on
@jeffbova-im7on 2 месяца назад
ive learned alot from you whether its ac or heating, i doubt i will get scammed, thank you!
@biggredd2008
@biggredd2008 10 месяцев назад
Thanks, Awesome trick to help us from getting screwed over 👍👍👍👍
@luckychucky3426
@luckychucky3426 7 месяцев назад
Thank you there's a friend of mine I think can use this information very well done congratulations there's something I've never knew and every homeowner should know
@brosephgnarballs
@brosephgnarballs 9 месяцев назад
The flame/smoke test is a good one to perform, but I have an issue with one thing you said. Something along the lines of "a small crack that won't do anything." That is a seriously dangerous mentality to teach homeowners. If there is indead a crack, no matter how small it is or whether or not it will disrupt the flame at the time of testing, it is completely irrelevant. That small crack can and will grow. No matter how small a crack is, either the heat exchanger should be changed out or the furnace. If you're telling your customers a small crack is nothing to worry about, you're endangering them.
@KodieIvie2
@KodieIvie2 9 месяцев назад
Yeah no kidding..
@danielzertuche9893
@danielzertuche9893 10 месяцев назад
Good preventive maintenance tips especially the winter times or anytime. Thanks !
@kw_boeing
@kw_boeing 10 месяцев назад
Great video! Looks like that is almost the exact same model of furnace as my grandpa’s!
@rayzerot
@rayzerot 10 месяцев назад
Even easier- run the blower and stick your manometer in each tube. Any pressure change indicates airflow from your blower into your heat exchanger and proves there is a crack (of any size)
@thecatdaddy1974
@thecatdaddy1974 9 месяцев назад
That would work fine for techs, but he is showing how to do it for homeowners to keep from getting scammed.
@donreahm5512
@donreahm5512 9 месяцев назад
Can a heat exchanger get clogged
@EnigmaticJack
@EnigmaticJack 9 месяцев назад
⁠@@donreahm5512yes. More common though is with a high efficiency furnace with the secondary heat exchanger, the secondary sometimes will get clogged. I’ve also been to some 80% gas furnaces that actually sooted up the heat exchanger like oil would due to a bad fuel/air mixture
@pgb1913
@pgb1913 10 месяцев назад
Excellent video!! Thanks for showing us how to test heat exchanger
@rodneysnook8252
@rodneysnook8252 7 месяцев назад
Thanks for that information. I really appreciate it. You do good work.
@mikesaldamarco5193
@mikesaldamarco5193 9 месяцев назад
Outstanding video. Thank you! I am dealing with this issue right now. Flames unstable. Trips flame rollout switch after 10 minutes. Just installed new inducer thinking it wasn't doing exhaust sufficiently but flame rollout switch still tripping. Tech verified temp on switch exceeding tolerance. Concluded must be working correctly. More strange is that no exhaust from inducer. Tech now believes it's the heat exchanger. Welcome comments from anyone who reads this.
@chetmyers7041
@chetmyers7041 8 месяцев назад
Just curious what the problem was with your furnace?
@mikesaldamarco5193
@mikesaldamarco5193 8 месяцев назад
Burners would shut off after 10 minutes of operation and trip the flame rollout switch. Contractor recommended new furnace stating Heat exchange is cracked. I have since discovered my secondary heat exchanger is clogged/rusted. However learned today that and both primary and secondary heat exchanger are still under Carrier warranty and they will replace. @@chetmyers7041
@cookie.2118
@cookie.2118 Месяц назад
yeah, there's many HVAC Techs out there that will show you a photo of a crack heat exchanger that they "took" of yours but it actually isn't yours. Always check yourself, this video does a good job of telling you how.
@tonybell6985
@tonybell6985 7 месяцев назад
Love the animation , thanks for helping us DIY, great video.
@aware2action
@aware2action 10 месяцев назад
Excellent presentation👍👍. Just some thoughts on the behavior of the flame: The crack(or hole) on heat exchanger is probably reducing the intake flow from furnace burners apart from introducing turbulence. The reason, why the lighted match goes out, is because of not enough suction, making the heavier Co2/CO (by product of burning) choke the flame. The dancing is probably because of partial flow of air up, with the heavy Co2/CO flowing down at the same time, creating turbulence. The lighter on the other hand is less affected, because of the higher efficiency of butane in burning and pressurized butane pushing the exhaust Co2 out of the way.❤️👍
@s.j.5850
@s.j.5850 3 месяца назад
How is the "heavier Co2/CO (by product of burning) choking the flame" when the test was performed with the burners off?
@billsmith2212
@billsmith2212 9 месяцев назад
I bet some " techs " carry photos of cracked heat exchangers . If they are dated and it doesn't match - time for a " mysterious truck fire " !😂
@billy5032
@billy5032 9 месяцев назад
Closing off some of the supply dampers might help raise the static and help accentuate an issue.
@CanyonDavis
@CanyonDavis 10 месяцев назад
Great tip, thanks for teaching me something new.
@davem5308
@davem5308 9 месяцев назад
I haven't fully "fallen for it" , because I do not have the money to buy what they say will require me to spend $4-5,000.00, for a new mobile home furnace. My furnace was emitting the smell of fuel oil into the inside air, upon the on cycle. The fuel stinks. Can't be living with that smell, it's not normal. After several attempts, by 3 different technicians, who could not figure out why the house was smelling of raw home heating oil, they settled on a cracked heat exchanger. This was about 3 winters ago, and we have been surviving winters with the wood stove and space heaters. The furnace of course provided nice even and reliable heat, but many economic factors like losing my job directly related to an alleged killer pandemic, has left me living by the skin of my teeth ever since, with bank account decimated. Thank you for this video, and showing us this methodology. Can you repair cracks with any special material, if you can find the cracks or holes?
@jamkpa
@jamkpa 10 месяцев назад
Well done with the demonstration!
@SkyChaserCom
@SkyChaserCom 8 месяцев назад
A legally blind friend of mine outside of Chicago had a control board replaced (over $1,800!) and the guy said his exchanger was cracked and quoted him over $7,000 on a new furnace!!! I did this test using a long lighter and flame was straight up in all tubes. For you Chicago area peeps - Avoid "Four Seasons" or "ABC" by all costs.
@jayneerindefranco3085
@jayneerindefranco3085 10 месяцев назад
Thank you so much for your great videos. You saved me over 400 dollars on a service call. Keep up the good work.
@jamesfitzgerald2361
@jamesfitzgerald2361 10 месяцев назад
Thank you for letting us know about this so we don't get taken to the cleaners from some not so honest technician.
@username_undefined
@username_undefined 10 месяцев назад
This was the best video I could find on this subject. Thank you for showing us!
@Tom-zx4te
@Tom-zx4te 9 месяцев назад
Excellent explanation! Wonderful video.
@calebbroadhead348
@calebbroadhead348 9 месяцев назад
I'm new to this, but even if it does have a small crack, it's better to replace it then to forget about it and those crack(s) become bigger and more deadly. Overtime it will also smut up the inducer and your exhaust stack which is an indicator that it has cracks.
@recycledpaul9728
@recycledpaul9728 10 месяцев назад
Please run the heater so we can see if the flame is still blue or lots of yellow flames. Thanks
@ThomasGray-f1s
@ThomasGray-f1s Месяц назад
Checking a hx with a candle or matches is something we did back in the day. What happens when the hx crack is so small it doesn't affect the flame of the match? This is why good techs use a combustion analyzer and not outdated methods
@anyhourdlaird8714
@anyhourdlaird8714 7 месяцев назад
I like what he’s doing here. My only concern is the American Gas Association states any visible crack or hole is reason for requiring replacement of the heat exchangers or the furnace. You could have a good sized crack that has not fully opened up to interrupt the flame in this example of this video. However you can’t tell a homeowner they are fine to operate the furnace because it’s not making the small flame on the match jump around. It may not be in this example however it’s not a matter of if, it’s a matter of when. I’ve pulled hundreds or thousands of blower motors and evaporator coil doors to inspect heat exchangers. This is like saying well your car tire is showing wire on the inside of your wheel. However car drives fine for now so you do not need to replace the wheel. Again not a matter of if, matter of when that tire will blow. I do however see larger cracks and holes that this test would come in handy however most homeowners understand right away when I bring them down to the furnace and show them exactly what I’m seeing. This dude does seem like someone I would hang out with though. Seems like good people for sure
@Regii_HVAC
@Regii_HVAC 8 месяцев назад
Companies do try and sell new equipment but it’s still important to tell the customer that cracks never get smaller or seal up on their own, they only get worse and it doesn’t rule out the fact that in due time this crack will leak CO into the ducts if there is indeed a crack
@donc.8019
@donc.8019 8 месяцев назад
I thought about that.with this video I know what to look for now. My issue is a blue flame with yellow Ridge. I did Match test it looks good. Burners are all clean. Did match with induction motor on also I get a little Backdraft feel something may be restricting induction motor draw also I feel my gas pressure may be low (will have professionally check) Thank you for the video
@Geonious
@Geonious 10 месяцев назад
I hate crooked HVAC techs!! Thanks for your videos!
@jetstream123
@jetstream123 10 месяцев назад
Great information. Going to check mine tomorrow.
@CommonSenseFishing209
@CommonSenseFishing209 8 месяцев назад
Need to test with blower door closed. Basic draft test. No flame required. Just turn on blower and see if any air is coming out of burners. Good stuff. Simple check. But remember to always check with blower door closed.
Далее
HVAC Companies HATE That You Can Do This Yourself.
25:51
HA-HA-HA 👊  #countryball
00:15
Просмотров 1,4 млн
БЕЛКА РОЖАЕТ? #cat
00:24
Просмотров 733 тыс.
Is Your A/C Unit About To Die? This Tool Doesn't Lie
10:03
How Many ERRORS Can You Fit in a Video?!
20:40
Просмотров 3 млн
Most Common Furnace Problems & How To Fix Them
12:09
Просмотров 21 тыс.
Yearly Furnace Cleaning And Maintenance Pro Tips
8:56
Просмотров 970 тыс.
How To Clean Furnace Burners
15:23
Просмотров 383 тыс.
The Shocking Truth About Ceramic Knives
14:53
Просмотров 674 тыс.
STOP Buying This HVAC Brand
9:38
Просмотров 592 тыс.
HA-HA-HA 👊  #countryball
00:15
Просмотров 1,4 млн