This video is a follow up to episode AC 032 and AC 033. In those past videos, separation between occupancies was discussed. AC 032 noted how to figure out if you need a fire separation between occupancies. AC 033 offered one way to avoid the fire separation. And now this video will show a second option that may allow two or more occupancy groups NOT to have a fire rated separation between them.
Please consider being my patreon or buying me a coffee :)
patreon.com/archicorner
buymeacoffee.com/archicorner
you can also follow me on my other social media:
/ archicorner1
/ 1archicorner
/ archicorner

Опубликовано:

 

2 мар 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 20   
@user-to7ol1pw3c
@user-to7ol1pw3c Год назад
Thanks for another great video Josué! Super helpful and clearly explained. I'll be using this a lot from now on!
@archicorner
@archicorner 11 месяцев назад
You are welcome!
@user-yp9hh9mn7f
@user-yp9hh9mn7f Год назад
Simple explanation and helpful!
@archicorner
@archicorner Год назад
Glad you think so!
@garrettriethman1873
@garrettriethman1873 Год назад
Literally just needed to learn about this for a project... and the perfect video was uploaded for it 5 hrs ago haha. Thanks!
@archicorner
@archicorner Год назад
Hope you enjoyed it! Talk about timing, haha.
@designereats3661
@designereats3661 Год назад
Very good! Keep making videos!
@archicorner
@archicorner Год назад
I am trying... more videos coming soon...
@wahidyuqob2016
@wahidyuqob2016 Год назад
Another fantastic video. I can compare your video to someone who is hungry and waiting for food. I had a similar project with "B" and "M" occupancy that I calculated, and when compared to your video, they do not require a separation.. Thank you again.
@archicorner
@archicorner Год назад
Glad you liked it!
@doanpham972
@doanpham972 4 месяца назад
I was corrected that a building is "sprinkled" in architecture school.
@archicorner
@archicorner 4 месяца назад
True.
@hikolyou
@hikolyou Год назад
Great
@josephbradshaw7584
@josephbradshaw7584 10 месяцев назад
Do horizontal assemblies allow you to get around the requirement for the number of stories? Per chapter 2 a horizontal assembly is defined as "A fire-resistance-rated floor or roof assembly of materials designed to restrict the spread of fire in which continuity is maintained." The reason I ask is because I have a project I'm working on that's very similar to this video where we have an A-3 and B occupancy, but we got a comment back from the city saying we needed to provide fire separation between these occupancies per table 508.4. My project manager said we haven't had issues with this on past projects because use nonseparated occupancies. However, I double checked if our project meets all the requirements for nonseparated occupancies and it meets all of them, except we exceed the number of stories requirement by one... However, the code uses the word 'portion thereof,' when referring to the building, so that makes me think there are exceptions and you don't have to include all the stories if a story is separated from the other stories with a horizontal assembly? For reference, 508.3.2 says: "The allowable building area, height and number of stories of the building or shall be based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building in accordance with Section 503.1. We also have a note on our plans that says "Level 1 is separated from upper levels by a horizontal assembly complying with IBC 711." So when CBC 508.3.2 uses the word ‘portion’ and we have a note about horizontal assemblies that makes me think we can exclude the first floor from the total number of stories requirement to meet this requirement?
@archicorner
@archicorner 9 месяцев назад
This is a fairly complicated question to answer, but short answer is yes, if you have a horizontal separation between floors, and they meet specific requirements, it’s possible to consider the buildings as two buildings. One building on top of another building. This is often referred to as platform construction, and the building at the bottom has to be built as a specific building type, usually type IA. There are too many details to discuss but it’s doable.
@josephbradshaw7584
@josephbradshaw7584 9 месяцев назад
@archicorner The first floor is made of wood like the other floors above, and it's Type III-A construction, so maybe it doesn't qualify as a separate floor... So yeah, it's a complicated question, but I appreciate your response, and I'm a big fan of your videos.
@Sandiegocruiser
@Sandiegocruiser 5 месяцев назад
are you in san diego
@islam56898
@islam56898 Год назад
We need videos about acoustics in architecture
@darwishmajdi
@darwishmajdi 11 месяцев назад
I literally die with the city of chicago reviews. Do you do consulting by means of sending you building department comments and you offering the best way to address city comments For example I have issues providing the correct UL numbers for a wall type
@archicorner
@archicorner 11 месяцев назад
At this time, I don't take on consulting work. My apologies.
Далее
How To Measure Building Height (AC-SHORT-001)
0:56
Просмотров 3,5 тыс.
AC 047 - Fire Extinguishers
13:32
Просмотров 3,4 тыс.
Finding General Lighting Load for Dwellings
16:59
Просмотров 94 тыс.
AIR CANADA INTERVIEW PROCESS EXPERIENCE
10:13
Просмотров 15 тыс.
What it Takes To Become A Corporate CFO
3:10
Просмотров 7 тыс.
AC 033 - Accessory Occupancies - What are they?
11:26