**Still valid in 2024**
CRMCA presents the Online Concrete Procedures for preparing for ACI certifications.
ASTM C157 / C157M - Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete
------------------------------------------------------------------
CRMCA website: www.crmca.org/
CRMCA Registration for ACI: www.crmca.org/...
ACI website: www.concrete.org/
ASTM website: www.astm.org/
ACI Reference for Modifications to C157 (2018): • Modification to ASTM C...

Опубликовано:

 

19 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 9   
@RajuSharma-ir5is
@RajuSharma-ir5is 3 года назад
The video at time 11:29 minute, How the shrinkage percentage value is calculated? Please explain..
@azbam87
@azbam87 4 месяца назад
I think your information is incorrect in your initial information in respects to consolidation. Although at 4:01 the reference to ASTM C192 is correct C192 does not give us a range for consolidation per lift it would be a flat 30 or 40 rods depending on the size of the mold. There should also be a range of 10-15 taps with a mallet as noted in C192. Although the video did help understand the test method in general. I thank you for many clarifications.
@crmcacolorado
@crmcacolorado 3 месяца назад
Thank you for the note. We will review for our update soon!
@JorgeLuisJaldinLarrain
@JorgeLuisJaldinLarrain 3 года назад
Thanks for this video. It arrived just in time.
@crmcacolorado
@crmcacolorado 3 года назад
We are glad to be there just in time for you! Hope it helps in the process.
@jesusglopez8430
@jesusglopez8430 Год назад
Thanks for sharing.
@taiwoagunbiade3619
@taiwoagunbiade3619 2 года назад
The % shrinkage looks incorrect.. or am i getting it wrong?
@arminjamali9067
@arminjamali9067 9 месяцев назад
Could you possibly inform me what value should be substituted if the gauge length is not 250mm (10 in.)?
@vlogsbybushra
@vlogsbybushra 3 года назад
awlla video
Далее
A SMART GADGET FOR CLUMSIES🤓 #shorts
0:21
Просмотров 1,7 млн
Split Cylinder Testing (ASTM C496)
5:22
Просмотров 119 тыс.
Alkali-Silica Testing, Alkali-Silica Reactivity
21:23
HOW TO OPERATE : Length Comparator Apparatus
1:55
Просмотров 15 тыс.
A SMART GADGET FOR CLUMSIES🤓 #shorts
0:21
Просмотров 1,7 млн