Split Cylinder Testing (ASTM C496) 

Matt OReilly
Подписаться 1,1 тыс.
Просмотров 119 тыс.
50% 1

Performing a split cylinder test on a 6x12 cylinder in accordance with ASTM C496.

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 37   
@foxopossum
@foxopossum 5 лет назад
Love this guy’s videos
@ozanergul6000
@ozanergul6000 3 года назад
nice shorts
@tinakumbhare3231
@tinakumbhare3231 5 лет назад
thanx alot
@abasalhussain4072
@abasalhussain4072 7 лет назад
can you tell us the basic concept of this test while we are applying compression load to find tensile strength please?
@syednajamulsaqib7664
@syednajamulsaqib7664 3 года назад
@I know Cause I'm BatMan. exactly this happens due to poisson effect.
@echpee
@echpee 2 года назад
We are applying compression in the vertical direction but the cylinder will undergo tension along the length.
@abubakarmohammed1633
@abubakarmohammed1633 8 лет назад
I appreciate.
@chandrashekharlakavath8748
@chandrashekharlakavath8748 5 лет назад
Hi matt Oreilly, What is the rate of loading of split tensile test...?
@oe3lab
@oe3lab 11 месяцев назад
100 to 200 psi/min [0.7 to 1.4 MPa/min]
@rogso6581
@rogso6581 Год назад
Rate seemed too fast
@rodriggoadolfo
@rodriggoadolfo 8 лет назад
the wood fringe ought be longer or equal to the cylinder.
@MurphysColesLaw
@MurphysColesLaw 8 лет назад
+Rodrigo Adolfo You are correct (and I do state as such in the video); when I made this video, I was a bit pressed for time and made do with what I had. One of these days, I'll go back and rerecord it and introduce a new series of mistakes :) .
@belalhossain5878
@belalhossain5878 5 лет назад
can i test the compressive machine? what type of instrument need the test please
@tengrenwei7684
@tengrenwei7684 7 лет назад
What is ur mix proportion for the cylinder?
@AjayKumar-og6dp
@AjayKumar-og6dp 4 года назад
Could you tell me your specimen height and dia. As far as i know i heard the dia probably 6 inch but i didn't know the height so tell me ?
@Vizzini13906
@Vizzini13906 4 года назад
12 inch, most likely for a 2:1 ratio
@arpitshukla9516
@arpitshukla9516 7 лет назад
Maniac
@italouruguayricano
@italouruguayricano 9 лет назад
I have done this test after treating the concrete with different conditions to see which treatment improves the concrete.
@pauljohnbaybay1099
@pauljohnbaybay1099 5 лет назад
what was the result sir? in numbers.
@DSgwapo
@DSgwapo 9 лет назад
is this the same as shear test?
@belalhossain5878
@belalhossain5878 5 лет назад
can I test the compressive machine beside would instrument name of the test
@udeshakasthuriarachchi8101
@udeshakasthuriarachchi8101 2 года назад
i also want to know if compressive machine can be use
@BiniMerina
@BiniMerina 10 лет назад
what is the practical use of this test?
@Binybini
@Binybini 9 лет назад
***** practically there is no such type of loading in the real environment. for example if you take compression and flexural strength testing for concrete, you can find the type of loading in the actual structure. so that you can use the result for decision purpose. to me the test is neither tension nor compression. to assume it is tension test the whole part(body) of the concrete should be in tension force. as you see here the force is applied in a line wise.
@SallySlayer409
@SallySlayer409 8 лет назад
According to ASTM you are supposed to average two measurements of length.
@hollowtheone
@hollowtheone 8 лет назад
Can we do the split test using 4x8 cylinder???
@MurphysColesLaw
@MurphysColesLaw 8 лет назад
Yes, unless your aggregate size is larger than allowed for a 4x8.
@donrebsagadguevarra687
@donrebsagadguevarra687 8 лет назад
cylinder size should be 3 times the aggregate size
@Kamikorosu0416
@Kamikorosu0416 8 лет назад
can someone tell me the practical use of this test and significance in real world? how do this differ from pure tension? please answer. need for research. thank you!
@angelmusonda7951
@angelmusonda7951 6 лет назад
The test is an indirect way of determining the tensile strength of concrete since direct methods are somewhat difficult.
@AjayKumar-og6dp
@AjayKumar-og6dp 4 года назад
Buddy carefully your finger stock in there
@iitgkaladka1888
@iitgkaladka1888 3 года назад
Your name reminds me of maddy o reilly
@Bellushaie
@Bellushaie 8 лет назад
could i ask at what rate was the load applied?
@MurphysColesLaw
@MurphysColesLaw 8 лет назад
+Baldeep Bhullar The ASTM calls for 100 to 200 psi/min, which works out to a load of about 150-300 lb/second.
@Bellushaie
@Bellushaie 8 лет назад
+Matt OReilly Thank you for your prompt response Matt. Cheers!
@gesyukushibatasou-mansion
@gesyukushibatasou-mansion 3 года назад
私たちの見てくれませんか (12) A NEW IDEA CONCRETE number 1 - RU-vid
Далее
Preparing and testing concrete cylinders (ASTM C39)
13:19
How To Perform a Slump Test - ASTM C143
7:43
Will A Guitar Boat Hold My Weight?
00:20
Просмотров 68 млн
БЕЛКА РОЖАЕТ?#cat
00:22
Просмотров 621 тыс.
Quality Control of Concrete On Site (Part 1)
14:44
Просмотров 187 тыс.
Preparing and testing concrete cylinders
11:23
Просмотров 47 тыс.
This Video Has Had 83,166,341 Views 🤯
11:08
Просмотров 83 млн
Compressive Strength of Cement Concrete Cubes
13:05
Просмотров 1,1 млн
14 Amazing Metal Work Processes You Must See ▶1
10:50