AddenDUMB: I Broke My CNC Plasma Table! | Learn from my mistake | Langmuir Crossfire THC 

Clough42
Подписаться 145 тыс.
Просмотров 47 тыс.
50% 1

When I put the monitor mount on my CNC plasma table, I totally broke the torch height control, without realizing it. Today, we're going to figure out why and fix it.
Tools used in this video:
*This site contains affiliate links for which I may be compensated
EEVBLOG Brymen BM235 Multimeter (Amazon*): amzn.to/2YKFSEk
Milwaukee Brushless 3/8" Impact (Amazon*): amzn.to/3uxwHJ4
Cable Raceway (Finger Duct) (Amazon*): amzn.to/3CFUskr
Metal Power Strip 12' Cable (Amazon*): amzn.to/3kZNktm
CarbonX Carbon Fiber PETG (Amazon*): amzn.to/3BEsoh3
CarbonX Carbon Fiber PETG (MatterHackers*): bit.ly/3l2grMx
ASUS 21.5" Touch Monitor (Amazon*): amzn.to/3B7MbW4
Beelink T34 M Mini PC (Amazon*): amzn.to/3nwjy1m
Hypertherm Powermax 30 XP Plasma Cutter (eBay*): ebay.to/2JgTrK6
Rhino Cart Welding Fixture Table (Amazon*): amzn.to/3za8aez
Raw Kevin MacLeod (incompetech.com)
Licensed under Creative Commons: By Attribution 3.0 License
creativecommons.org/licenses/b...

Опубликовано:

 

24 дек 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 199   
@Clough42
@Clough42 2 года назад
SAFETY NOTE: I do not recommend disconnecting any safety grounds. The connections that I isolated were connections between the plasma table frame and the earth ground that I inadvertently added to the system with my modifications. The plasma cutter, CNC electronics, computer, monitor, and plug strip are all still grounded to the safety (protective earth) ground through their power cords, as they came from the factory. I am aware that there are various documents recommending that plasma tables should be separately grounded. The Crossfire plasma table does not come from the factory with provisions or instructions to earth the table frame, and in fact doing so prevents the torch height control (THC) electronics from reading the arc voltage. If you are concerned about this, I'd love to hear about it in the comments, but I can't do anything about that design, as it is inherent to the Crossfire THC.
@spehropefhany
@spehropefhany 2 года назад
I guess a GFI (RCD) would take care of most of those concerns.
@boblewis5558
@boblewis5558 2 года назад
The solution (potentially) would be to opto isolate the signal feed/s from the table. But without seeing a schematic of the CNC height control it's hard to be specific.
@Clough42
@Clough42 2 года назад
@@boblewis5558 that is a very interesting idea. I don't see any reason why that couldn't be done, though it would require very careful matching of an optocoupler to stay in the linear range.
@cs233
@cs233 2 года назад
@@spehropefhany I bet a GFCI in this situation would be tripping out constantly from stray currents induced by the plasma cutter, especially now that you have two ground returns from the plasma cutter and the controller!
@notsonominal
@notsonominal 2 года назад
Telling the internet you did something wrong. Oh i'm putting on the popcorn and coming back to the comment section! Thanks for sharing and educating those open for that sort of thing..
@DavidNayer
@DavidNayer 2 года назад
As soon as you mentioned you went back to the carbon-reinforced materials, I had the concern that carbon fiber is a quite decent conductor. Evidently, the level of integration in your feed material, it's density, and discontinuous orientation of the cut strand is isolated enough that you didn't form a circuit with your part. Again the carbon version, like the metal is NOT necessarily - "more better". Running a composites shop, we are extraordinarily careful to keep fiber strands and dust out of the air as they eventually and inevitably find the magnetic fields of circuits and create shorts. Plain plastic is definitely more predictable isolation. ceramic, phenolic or even end-grain oak can provide modulus if you need them:)
@AmateurRedneckWorkshop
@AmateurRedneckWorkshop 2 года назад
Well you ironed that out really quickly. And I thought I was the only person who could improve things so much that they stopped working.
@Clough42
@Clough42 2 года назад
Fix it 'till it's broke.
@joewhitney4097
@joewhitney4097 2 года назад
Great find and troubleshooting. Hopefully no damage will pop-up later. Thanks for sharing the "Lessons Learned", hopefully it will help the rest of us not over look these small details.
@practicemakesbetter7132
@practicemakesbetter7132 2 года назад
Merry Christmas, glad you solved your problem, no harm, no foul. A while ago, I fried my multimeter while diagnosing a plasma cutter; I mistakenly connected my volt meter to the high voltage output.⚡
@DavidKutzler
@DavidKutzler 2 года назад
As a retired healthcare professional, kudos for your excellent application of diagnostic process.
@AlmostMachining
@AlmostMachining 2 года назад
Solid find and fix James! Thanks for sharing.
@DavidLindes
@DavidLindes 2 года назад
Ah, it's the little things. Thank you for sharing this piece of your process!
@joell439
@joell439 2 года назад
Great troubleshooting James - thanks so much for showing us the problem and solution! Merry Christmas
@Pappaoh
@Pappaoh 2 года назад
"What kind of things have you screwed up by trying to be clever"... might be the best question I've heard all year😆. Great vid as usual James!
@ronaldherald3015
@ronaldherald3015 Год назад
finally got lined out on my plasma cutter i have been 3 weeks, burnt up one vim box and your videos saved me. i was ready to give up and sell my machine.
@cletusberkeley9441
@cletusberkeley9441 2 года назад
Merry Christmas to you and family James. A year ago I built my own 3-axis Mach3 control cabinet and also built my own Z-axis for implementing THC on the Crossfire. In doing so, it encountered the same grounding issue, but in the form of crippling EMI at the controller. Once the box was isolated, problem solved.
@VWKID61
@VWKID61 2 года назад
Mistakes the world’s greatest teacher . Thank you for teaching us through your mistake.
@Teklectic
@Teklectic 2 года назад
Thanks for sharing the mistakes, I think I learn more by seeing them and it also helps reinforce the fact that people in videos are actually humans that make mistakes just like the rest of us 😁
@johnwiley8417
@johnwiley8417 2 года назад
Merry Christmas, James & family! Nicely done diagnosis, too. I doubt it would ever cause problems after your fix, but you might want to insulate that mount at the monitor. The water in the tank probably gets conductive between cleanings, and that monitor stalk looks pretty close to ground. 73 de W4YBO
@Clough42
@Clough42 2 года назад
Splashing enough water to conduct is possible. Worth considering.
@Just1GuyMetalworks
@Just1GuyMetalworks 2 года назад
A nice, simple fix to close out 2021 😊. Happy New Year, James! 🥳 Cheers!
@EZ_shop
@EZ_shop 2 года назад
Excellent tip. I should be getting the THC upgrade to my older CrossFire in a few days and I'll try not to repeat your mistake. Merry Christmas. Ciao, Marco.
@keithbrown2458
@keithbrown2458 2 года назад
Not that I’ll ever own one of these, I’ve been a very long time retired however, a video well done sir, and thank you, I enjoyed watching it and learn something
@smithlevenson1
@smithlevenson1 2 года назад
Just found out I have a McMaster-Carr in Atlanta and its only a 30 min drive for pick up. Thanks for introducing them to me. They are awesome!
@Clough42
@Clough42 2 года назад
Indeed. Their shipping is pretty fast and reliable, too. Not cheap, but when you need something, it's good quality stuff.
@DougsMessyGarage
@DougsMessyGarage 2 года назад
A useful gotcha to be aware of. Thanks for sharing
@rpavlik1
@rpavlik1 2 года назад
As soon as you started describing the problem my brain went, the vesa mount screws! You just solved the problem higher in the chain. Very nice, thanks for sharing, and like you I am impressed nothing broke. Given how I haven't seen any signs that say "do not ground" on the metal frame, I'm a little surprised the box doesn't do a similar continuity test on startup. (I'd be curious how good the isolation is that you have now: what at least the British call a "Megger" - for measuring mega-ohms resistance vs thousands of volts, which is part of at least their workplace electrical safety routine testing - would be an interesting test, since the voltage used for continuity checks is pretty low.)
@Clough42
@Clough42 2 года назад
The voltage used for cutting is also pretty low (under 100v) so it's probably not an issue. They give a cutoff in the docs of something less than 100 ohms. Don't remember the exact number.
@seanwolfe9321
@seanwolfe9321 2 года назад
I can see how this is easily overlooked, I guarantee you’re not alone on this one James!
@Clough42
@Clough42 2 года назад
Yeah, for sure. There are a few forum threads about the same issue.
@DustinWill
@DustinWill 2 года назад
Great review of ground loop issues
@joeldriver381
@joeldriver381 2 года назад
Yep- I have done that and sometimes it even makes cool smoke!
@maximusmurua4437
@maximusmurua4437 2 года назад
thank you so much really appreciate the video having the same issue, hopefully it's the same fix
@ninthm00n
@ninthm00n Год назад
Metal is more better has been my musical philosophy for 30 years 🤘🤘🤘. Great video as usual James
@jjbode1
@jjbode1 2 года назад
Nice Christmas gift of advice from a bit of honest self-criticism. Thanks!
@davidewing9088
@davidewing9088 2 года назад
thank you for an honest post
@JonathanRockway
@JonathanRockway 2 года назад
It's always interesting to see what sort of signals people put through the chassis. I've been rebuilding a cheap 3D printer that suspiciously tied the logic board to the frame, but fortunately it appears that was just a "safety" ground. (Note that the printer takes 19VDC in, and no grounding, so it's not earth ground.) The nozzle, thermistor, heater cartridge, and bed heater never connect to the chassis ground, so nothing ends up being mysteriously polarized, fortunately. (You have to check, because if one end of the heater ends up connected to the case and that end happened to be wired to the control board's positive terminal, then you blow a fuse, which is annoying. But, luckily they isolated everything, so it wasn't a problem.)
@Clough42
@Clough42 2 года назад
For welding and plasma cutting, often the table is used to pass the arc current. That's all that's happening here. Though it typically isn't a huge safety issue, in this case it's a problem of offsetting the small divided voltage being fed into a microcontroller analog input pin.
@SianaGearz
@SianaGearz 2 года назад
Something to keep in mind is that the heaters are generally negative switched, because N-channel MOSFETS have a low RDSon and are cheap, and it's also cheap to not use any kind of special gate drive magic circuit; so when the board connects GND to the frame, you're one fault away from the heater switching being bypassed and the heaters being stuck on uncontrollably. Mind you since there is nominal heater resistance present in the path, fuses, even if present and well-chosen, won't fire either. It's a sneaky fire hazard. The only way around this is to have PS_ON control, so an extra relay that the board can switch that would unpower the whole machine, and ideally test that it also works with watchdog timer.
@ChrisS-oo6fl
@ChrisS-oo6fl 2 года назад
Well with a Langmuir it’s a ton! They are riddled with EMI/EMF noise as they use no methods of insulation or isolation. If there’s a manual on how not to build or wire a cnc Langmuir wrote it.
@appalachianman824
@appalachianman824 2 года назад
Thanks for this video !!!
@robertoswalt319
@robertoswalt319 2 года назад
At first I thought you were going to say that the grounding issue fried the computer. That would have surprised me somewhat since industrial computers are more resilient than the consumer PC, but there is always that one instance where something goes south and the magic smoke leaves never to return again. I am sure that this video will help people well into the future.
@outsidescrewball
@outsidescrewball 2 года назад
No harm…no foul…good discussion
@routercnc9517
@routercnc9517 2 года назад
Not a big one but today I was finishing mounting a DRO to my drill press (long project) and after several hours work I turned on the display, moved the axis, but the reading didn’t change. I was worried I had damaged something during the installation. Eventually I realised I had not plugged it into the display! All working fine now.
@jamesbrewer3020
@jamesbrewer3020 2 года назад
Merry Christmas
@makerdave42
@makerdave42 2 года назад
My current project had a similar issue with a USB connector and a touch screen. The entire aluminum frame and enclosure is connected to mains ground. Turns out the OEM touch screen mounting pads were connected to the electronics ground which in turn meant the electronics ground was connected to mains ground. Had to use plastic mounting screws and washers to isolate it. Next was to make a custom USB enclosure surround to keep the USB ground from touching the case. No damage from being grounded but testing with the meter was kinda baffling at the start.
@SianaGearz
@SianaGearz 2 года назад
Whenever USB is present, you can assume that it will be earthed sooner or later, for example via an ATX PC.
@boblewis5558
@boblewis5558 2 года назад
It seems at least one other person has spotted the same issue I did. My youngest brother is the senior electrical engineer at a top F1 team and been there for 27 years! The problems he has experienced and had to resolve due to carbon fibre composite conductivity are many and varied. Without going into great detail I should advise anyone thinking of using ANY form of carbon composite material to consider fully and test experimentally any possible issues that may occur. An example of one "trivial" decision such as to cut two separate holes to pass high current cables through a carbon fibre sheet rather one much larger hole is the potential for LARGE eddy currents WITHIN the carbon fibre to occur (just as in a steel sheet) & generate a LOT of unintended & unexpected heat and even fire. James, you may be lucky with the carbon filament you have used but it MAY just be that there is NOT full isolation but sufficiently high resistivity to "isolate" the problem. A proper high voltage isolation resistance test from a tame sparky might be wise as a precaution.
@Clough42
@Clough42 2 года назад
There isn't enough carbon in this filament, and it isn't continuous. The good news is if it eventually breaks down and conducts, the torch will stop firing.
@scottbscop1251
@scottbscop1251 2 года назад
Great info
@markparker7720
@markparker7720 2 года назад
The ground gremlin strikes again - thank goodness it didn’t damage anything. At first glance, I thought you had epoxied your hand to your forehead - hate it when that happens 😀. Really like the subjects you cover.
@FrancisoDoncona
@FrancisoDoncona 2 года назад
It might be a good idea to relocate the monitor location so you could stitch a larger than the table size on your table utilizing the open end of the table. That is one advantage to the smaller table, I have hard mounted my power strip, the water pump and have my plasma cutter seated on a welded on frame tray. Nice to know I have work to do.
@Clough42
@Clough42 2 года назад
This setup is really ideal for my small shop. I've pulled it out and used it several times, and it's super convenient.
@hamood1234fool
@hamood1234fool 2 года назад
When I was a noob at electronic, I was so confused seeing the starter of my car having a single wire. I was like how the starter is working with a single wire. I didn't know the hole car body was the ground. :)
@rpavlik1
@rpavlik1 2 года назад
Bad chassis grounds are the bane of very many trailer lighting setups, where it's substantially harder to get a nice solid conductive path in say, a folding trailer....
@skesseks
@skesseks 2 года назад
repeating Mathieu B, I would use something other than the carbon fiber petg, it is not conducting now, but I think you maybe lucky, and wear and tear may eventually make electrical contact.
@Clough42
@Clough42 2 года назад
There isn't enough continuous carbon to conduct well enough to be an issue. It would need to be under 10K ohms to be an issue.
@millomweb
@millomweb 2 года назад
It's a matter of remembering where your wires are - and the fact the table is one of them !
@ride_panzer
@ride_panzer Год назад
thank you for this video
@mroygl
@mroygl 2 года назад
A video out of a couple of plastic washers? 8) still you are good at it and happy 😁
@bernardwill7196
@bernardwill7196 2 года назад
I wish to you and your family Merry Christmas.
@EverettsWorkshop
@EverettsWorkshop 2 года назад
Well, I'm just glad nothing expensive got baked on you in the process. I think we all have some ideas that turned out not so great in the long run, lol, we're all human.
@derecknistler8393
@derecknistler8393 2 года назад
Ground isolation is always a challenge. One thing that is easy to overlook when using PC peripherals is the connector housings. USB, HDMI etc connectors are tied to chassis ground within most devices. Easiest way to check is to measure continuity from AC input ground to connector housing. If no continuity is measured, plug in a regular USB drive and recheck. Some USB peripherals do not isolate signal and chassis ground.
@Clough42
@Clough42 2 года назад
Agreed. This is a big issue with laptops, since often the ground is connected to the negative of the DC supply, and the current causes voltage drop and noise in the ground reference, and any unbalanced audio output.
@thestrouds8823
@thestrouds8823 2 года назад
Love all the haters out there. I made a silly mistake with my table this summer.... I set an exhaust manifold on it to weld a broken bolt. This resulted in damaging the transistor on the motion control board for torch fire control. Didn't know I did until months later making Christmas presents. Guys at Langmuir helped diagnose and really took care of me. I love my little crossfire. Only wish I bought the pro for size!
@klasmalman9249
@klasmalman9249 2 года назад
As others also stated… watch out for the conductivity of CF-reinforced filament. Depending on print settings it can become conductive. If i remember our tests correctly, the conductivity of the 3dxtech CF-Petg increases with print temperature. Stratasys CF-reinforced filament prints ARE conductive to a higher degree… i would replace these CF parts for pure plastic, to avoid indeterministic future issues. ( I would not trust the parts to keep their high impedance when exposing them to transient voltages, as the plastic so easily can alter its behaviour due to print settings.) That said… i am a heavy user of 3dxtech esd-petg for electronic projects… as normal petg generates quite big levels of electro static voltages when breaking them free from the metallic build plate of the Prusas we use.
@brianrhubbard
@brianrhubbard 2 года назад
I fried the PCM on one of my customers Jeep once. I was using a Power Probe Hook to test a crank sensor and needed both hands to place the leads. I had wedged the probe between the heater hoses so I could see the screen. I had a coworker start the engine. As engine started, it shook the heater hoses and depressed the voltage button. It sent 12V to the PCM via the signal wire. $800 later, I learned to never use a Power Probe to check for sensor signal.
@andarthome142
@andarthome142 2 года назад
Happy christmas, and i din't know that earth thing thanks for the warning🎄🎇✨👍😎
@steinmargunnarsson3709
@steinmargunnarsson3709 2 года назад
One thought: the printed sleeves; do they contain considreable amount of carbon fiber ? Carbon fiber is conductive in tself, so you might need to keep an eye how this evolves. Personally I would have used PE for the sleeves as enything containing carbon fiber can easily be conductive.
@splackism
@splackism 2 года назад
I was thinking exactly the same.
@Robinlarsson83
@Robinlarsson83 2 года назад
Same here, I've been toying with the idea of 3D printing some cover plates for a saildrive that I'm modifying to be electric. Would be cool to do them in CF-PETG, which I have an un-opened spool of on hand. But, they would be bolted in to the saildrive housing against bare aluminum. It's on the inside of the boat, so not going to see much water, but definitely some moisture and salt. The plates will cover holes from old hardware, so will need to seal against the housing with o-rings. I'm worried that I'll get a corrosion problem between the CF and the aluminium and the stainless bolts..
@jhawker2895
@jhawker2895 2 года назад
So proud of your honesty and willingness to share ... I am living proof that dumb mistakes only get worse as your age increases ... sorry ... But maybe you will break the trend... Thanks for Sharing ... Stay Safe and Merry Christmas ...
@ocAToccd
@ocAToccd 2 года назад
Hopefully it didn't fry anything... Just in case something (some sheet or else you are cutting) goes shorting the table to the post (which isn't far), I would insulate the monitor from the post (opening the holes in the mount and adding some plastic spacers should do the trick) Don't bother making mistakes! Sure you learn things but we do too :) even more when you make the mistakes before we have the chance ;)
@Clough42
@Clough42 2 года назад
This is not a bad idea.
@weldersandblaster
@weldersandblaster Год назад
I'm about to add THC to my crossfire. Thanks for the heads-up. I'd much rather avoid a problem than spend a day diagnosing it as I pull out my hair.
@askquestionstrythings
@askquestionstrythings 2 года назад
"because Metal is more better" 6:34 yep, generally true... electrical isolation can be a pain though.
@Graham_Wideman
@Graham_Wideman 2 года назад
James obviously "solved" his problem, but this video provokes more questions than it answers! Part of the confusion appears to be between electronics signal ground versus chassis safety ground and the implications of connecting the chassis ground of the control box to the chassis ground of the table. In principle, no arrangement of interconnected grounds should cause the plasma voltage detect signal to get shorted and read zero... unless.... OK, so the plasma table is basically a positive-ground system -- that is the table carries the positive side of the plasma power, and the torch voltage (to be measured) is negative relative to that. And yet Langmuir's detection interface "Voltage Input Module" (VIM) appears to consist of a simple voltage divider, possibly with some filtering. If it has no active component, then it will produce a negative output voltage (relative to the table). But that would require the Torch Height Controller board to accept and digitize a negative input voltage, which most analog-to-digital converters will not do. That could be easily solved with an inverting op amp circuit on that control board -- but is that what Langmuir implemented? The alternative would be to float the electronics and attach the electronics signal ground to the negative output wire from the VIM, and feed the VIM positive output (ie: possibly the table frame) to the ADC positive input. If _that_ is how it's implemented, then of course an unanticipated connection of the electronics ground to the plasma table will short the VIM output signal, and make the TH control board see zero for the plasma voltage. That would be a very poor design, so I don't want to jump to conclusions, even though it explains the symptoms. It would be super interesting if James would measure the signals from the VIM to the TH controller, and determine what their voltages relative to the table, and relative to electronics ground! Meanwhile, judging by forum posts, some owners of this gear have other problems relating to noise propagation of one sort or another disrupting the controller MCU(s?) and/or comms with the PC. These may entail grounding or shielding issues, but are not the same as the controller running fine but seeing a zero plasma voltage. Further, connection of industrial gear to a PC over USB is a known issue in general, and greatly eased by providing an isolated USB port, at the cost of a ~$1 part, (though supply of those has dried up during the chip shortage).
@MaX271
@MaX271 2 года назад
FYI, you can measure negative voltage with any ADC using a resistor divider. You only need a positive bias.
@Graham_Wideman
@Graham_Wideman 2 года назад
@@MaX271 You indeed propose an alternate way to avoid having the ADC see a negative voltage. And that method is going to require a positive voltage reference and also depends on knowing pretty exactly the source impedance (in the separate VIM box) in order to combine it with one or more additional resistors to get a known divider ratio. Unless you add a local buffer, in which case you might as well make it inverting. My point was that Langmuir would have to implement _some_ strategy, however trivial, to deal with this. One of those strategies (electronics ground connects to the VIM negative) leads to the symptoms James saw, but again I'm reluctant to think they did that without further evidence
@icecool742
@icecool742 Год назад
Well... I am glad I watched this .. lol I was wondering why I need plastic washers for .
@billmaguire6216
@billmaguire6216 2 года назад
Suggestions for your plasma table from experience with mine. Put it in a separate room and/or build a downdraft vacuum system to evacuate the particulate while cutting. Even with the downdraft you WILL get top spray that will accumulate in your shop unless you set a vacuum nozzle at the cutting tip. For best results put it in a separate room and build a downdraft for it. Just saying. Enjoy your videos
@Clough42
@Clough42 2 года назад
Yeah, if I had more than a bay and a half of a residential garage, I would totally do this. I would also have a separate room for grinding. As it is, the table sees occasional use, wheeled out of the corner to cut something, drained and wheeled away to store.
@billmaguire6216
@billmaguire6216 2 года назад
@@Clough42 I was just going to edit what I wrote earlier. I had a 2100sft shop and noticed even with the downdraft it was getting over spray in the surrounding area. I realize you will do occasional cutting so please disregard my previous post. On a side note, I agree with your mistakes video. I should have a PHD by now from the mistakes I've made and learned a lot. I just resubscribed to enjoy your content. Have fun.
@kswiorek
@kswiorek 2 года назад
This looks like a nightmare to find the short, but fortunately you didn't break the controller with this high voltage. I once connected 20V to USB data through a faulty stepper driver and it broke a few USBs on the motherboard and the computer has some trouble booting now
@eglenns
@eglenns Год назад
Nice. Any chance on sharing the G-Code for the spacer?
@donteeple6124
@donteeple6124 2 года назад
Deductive sleuthing at its best !!! And how do I fix it with innovative reasoning. Good Job......
@edwardcruz5187
@edwardcruz5187 2 года назад
2- things i need to know from you.. your powermax 30xp, have you cut aluminum with it and what is the max thick you have cut with it (any material) ..?
@CJ-ty8sv
@CJ-ty8sv 2 года назад
I'm really curious now if that did in fact fix the problem because our plasma table at work (which has THC too) has the controller box grounded though the table and through the ground pole of the power plug. One thing to note though that might be a factor here is that per the manufactures instructions, our table is directly grounded to earth via 10ft of ground rod driven into the ground next to one of the legs of the table and its connected to the ground connection point on the table where the plasma work clamp ground connects. I know that there was a note in the install instructions that said that without that true earth ground, there will problems with erratic THC control behavior.
@Clough42
@Clough42 2 года назад
The THC design is probably fully isolated on that unit.
@Midlife-Adventures
@Midlife-Adventures 2 года назад
Whilst this is working the use of carbon fibre reinforced plastic raises a little concern for me. Makin the sleeves with a conductive element seems like a risk for some future hard to debug issue. I've not done any work with that material yet in 3d printing, mostly know it in terms of electrolysis risk in composite form where the structure is quite different.
@chris-tg6ki
@chris-tg6ki 2 года назад
Carbon fiber is a great conductor!
@larelare1
@larelare1 Год назад
I skipped checking all corners on a cut and over an empty space, the THC started diving. Coulda been bad but the empty space wasn't that big.
@PaulSteMarie
@PaulSteMarie 10 месяцев назад
Any issues with the carbon fiber making the sleeves somewhat conductive?
@davidcashin9194
@davidcashin9194 2 года назад
Hi James there is not enough lines on you tube to list all the screw up's I have made in my life time but that one is a very easy one to do and yes I have done it not on a plasma table as I don't have one, but it can happen on many different machines that have a computer attached. Often it is allot harder to track down probably why I don't have any hair left.
@ajd1079593
@ajd1079593 9 месяцев назад
I noticed you are using a 30xp and the thc upgrade. I am using the same table and cutter. I purchased the thc upgrade but I am not sure how to hook it up inside the 30xp any tips? Specifically what color wires to hook to.
@amahashadow
@amahashadow 2 года назад
ah, yes, the goods old ground through a data cable. Learned that one the hard way on my first project at my first job. We made a data capture box for Buses (that they could plug in to the bus PLC, capture acceleration/deceleration/speed to analyse driver performance), spent 4 months on it, worked flawlessly. we deliver it to the customer, they come back saying it didn't work. We try it, it works, ok, check all the cables, everything is fine. I go, with my boss to their office, we plug it in, it doesn't work. I get my laptop out, it works. raaaah. turns out, their laptop power bricks passed ground over to the positive pin to the computer. When plugging in the serial port, while the capture box was connected, the ground from the db9 between computer and plc would create a ground loop and crash the electronics.... that was a fun one.
@Clough42
@Clough42 2 года назад
Wow. That's pretty bad. I guess as long as everything you connected was floating, you'd never know the whole laptop was below ground potential DC.
@johannglaser
@johannglaser 2 года назад
Did I understand correctly, that the nuts in the monitor's VESA mount are connected to the monitor's ground? Then I would rather recommend to isolate the monitor's VESA mount from your monitor stand, instead. As it is now, a larger sheet of metal could easily short between the vertical bar of the stand and the table.
@Clough42
@Clough42 2 года назад
Yes, it could. The torch would not fire, though, so it would become immediately apparent if this happens.
@MalcolmReynolds14
@MalcolmReynolds14 2 года назад
How long did it take to chase that down? Myself, I'd have pulled most of my hair out before finding that issue.
@yellvett76
@yellvett76 Год назад
I have a similar problem, maybe you can help. When I check continuity from the USB to machine frame It show continuity, only when the Plasma cutter is plugged into the DIV input. Do you know what would cause this. any help would be appreciated.
@nicolaspillot5789
@nicolaspillot5789 7 месяцев назад
do you think the manufacturer could feed the height voltage through an isolating adc/comparator ? instead of simply feeding it to the control box, which is the root of the problem ... afaik
@edwardcruz5187
@edwardcruz5187 2 года назад
dude , you're a fabricational rock star ...
@QuebecoisSti
@QuebecoisSti 2 года назад
High frequency of plasma unit can be pretty bad on electronics. Good thing you didn't fried anything because sometimes it does that to boards....
@Stefan_Boerjesson
@Stefan_Boerjesson 2 года назад
Shit. A ground loop the long way.... During university courses in electronics and measurements we learned about ground/earth free measurement situations, and the cautions. . Why a screen, computer would be have chassis to ground/earth? Poor design I would say. Pooh, nothing got damaged. Very nice to hear. You were lucky having equipment that just shut down. It's nice to deal with electrical stuff being "fully isolated" meaning having to protective ground/earth... To Your final words.... In the end of the 1970:ies we built hobby computers, Z80, Texas 9900 etc. One hard thing was to get a monitor. Some guys used televisions and they had the chassis connected to one of the two mains pins..... That called for turning the mains plug to the right position to get the chassis connected to the neutral......
@dave_the_bartender4904
@dave_the_bartender4904 2 года назад
Any reason you went with the Avid CNC router instead of the Langmuir mr-1 ?
@Clough42
@Clough42 2 года назад
The MR-1 didn't exist a year ago when I placed my order.
@JohannSwart_JWS
@JohannSwart_JWS 2 года назад
But, but, but, surely CF PETG is also conductive to some extent? Did you measure with the resistance setting, instead of the continuity test of the meter? My Fluke has a threshold for continuity, which still shows reduced resistance, but does not always trigger the continuity signal. But then again, you know what you're doing...
@Clough42
@Clough42 2 года назад
Not really. It would need to be under 10k to matter.
@frijoli9579
@frijoli9579 2 года назад
Curious what the resistance is of the Carbon printed parts.
@thefekete
@thefekete 2 года назад
My thoughts exactly! The carbon fibers are definitely conductive, whether they're close enough together in the PETG to cause a low enough impedance connection is the question he answered in this video😋
@Clough42
@Clough42 2 года назад
It reads open circuit. The fibers are not continuous.
@Know-Way
@Know-Way 2 года назад
I thought the same thing, while simultaneously thinking carbon fiber embedded in plastic likely not a problem. The conductivity of the carbon fiber is probably measured in nanosiemens and is irrelevant. Though I'd keep it in the back of my mind if things get wonky in the future.
@KW-ei3pi
@KW-ei3pi 6 месяцев назад
Great Info. Thanks very much. Did you really say that metal is "more better"? LOL Just had to give you a bad time.
@jmhannnon
@jmhannnon Год назад
This is a bit confusing. If what you say is true this means in operation anything connected to the return lead of the torch is not at ground potential. This sounds potentially dangerous. I think the problem really is related to the way the torch height voltage is measured. Got to look at how my torch is wired tomorrow. Planning on mounting my plasma torch to my CNC router table.
@Clough42
@Clough42 Год назад
On this table, the cutting circuit is floating, and not ground referenced. In practice, the table probably ends up floating around 5V above the earth ground, due to the way the torch height control divider circuit works. As others have pointed out, this wont be a safety problem unless something else goes wrong. But it could become dangerous if the torch lead were shorted to ground, for example. I would not have felt comfortable designing it this way and selling it.
@DavidV328
@DavidV328 2 года назад
Well, building the ELS, mixing 2 projects on the workbench and connecting 25V DC to the circuitboard instead of to the servo. Which fried the logic board, the Clough42 driver board, the rotary encoder and the display circuit board. Nice going, expensive mistake, and smelly
@Clough42
@Clough42 2 года назад
I'll bet.
@MichaelLloyd
@MichaelLloyd 2 года назад
Ground loops can really be a pita to solve. Nice work!
@koen8973
@koen8973 2 года назад
Finding those kind off short circuits in elevators always make you rethink your capabilities.
@duke4119
@duke4119 2 года назад
Isn’t carbon fiber typically conductive?
@Clough42
@Clough42 2 года назад
The fibers are, but the composite of chopped fiber in PETG isn't.
@ChrisS-oo6fl
@ChrisS-oo6fl 2 года назад
It is interesting since most pro level tables ground the enclosure to everything through star grounding. Hypertherm has a 12 page manual in proper “star” grounding of everything so does Lincoln. All main plasma systems call for a single busbar to each individual component including Cabinet, gantry and the Z to an earth ground/ Rod! It’s common to ground all these points then run it to a wall ground. Langmuir machines are a horrible quality product. They don’t use ANY (absolutely no) double shielded cable or drains and in fact.. they use standard printer cable with no db9 pas through EMI filters. The noise issue is exactly why they don’t implement safety products like limit/ home switches or e stops. They don’t use any ferrites They split wire all power lines, coms and grounds! They use no busbars or distribution blocks! They use all (too long) 22 gauge non silicon wire with agin no shielding or ferrites between the controller and the cheep $10 Chinese drivers. The don’t use proper terminals or ferrules, they just tin the wire! (Even in the PS! They use cheep, unbranded and “Noisy” power supplies! They use usb power to power the 5v and 24v lines of their older Chinese boards....pre Arduino uno board. They shipped units with improperly rated torch relays for months! The original relay was also inadequate! They don’t coat the control box in EMI/EMF protective coatings. They inadequate ground the entire machine. They use extremely cheep stepper motors. They use undersized ball screws that whip like it’s a hurricane and many times arrive bent. They use no preload bearings/nut on the ends. They use cheep backlash nuts. They use non EMI filtering AC panels mounts. They use extremely cheep panel connectors know to arc, rot, crack, and melt with no ability to drain EMI! They have customers use T-splice connectors on their plasma cutters. Their marketing is the only thing they do well...like no other cnc plasma company that came before. They have a business model that sells inadequate products then UP sells continuous UPGRADES to its consumer base. Their forums are filled with idiots who’ve completely rebuilt their machine many times over but are still loyal to the brand like a cult. They used to falsely claim that their linear bearing system was proprietary but wasn’t. Their water pans / water table can’t even fully drain, yet they know this, still produce it the same and suggest that each and every customer modify their own pan. They white labeled “fire control” and utilized open sourced projects for their THC and main board firmware. I was extremely disappointed to when you started pushing their machine. You know quality components and engineering! How many sub par machines do you think your channel sold? You fully comprehend EMI protection. You know the value of these sub par components don’t justify the MSRP if a 2x2 2 axis machine. Your peddling junk. There are serious quality control issues with this brand! n in arguable fact.
@jamescole3152
@jamescole3152 2 года назад
Ok lets say you are right about the quality. Yet they do seem to work for most people. And we can afford to buy it. You forgot to mention what CNC machine we should buy. All your complaining and you left out the main point.
@ZomB1986
@ZomB1986 Год назад
I spotted a multimeter that I also own
@seanwolfe9321
@seanwolfe9321 2 года назад
How did all of us genius-tell you what you’re doing wrong, know it all’s, not see this coming?!?
@tootalldan5702
@tootalldan5702 2 года назад
I would have thought the plasma cutter voltage would have had a full isolation measurement.
@Clough42
@Clough42 2 года назад
I think this is a case of it being a simple hobby-grade controller.
@Clough42
@Clough42 2 года назад
I think that would be ideal. Even a non-isolated differential probe would probably solve it, also.
@hairyfro
@hairyfro 2 года назад
USB ground is connected to earth ground through the monitor?
@martinmckee5333
@martinmckee5333 2 года назад
There are loads of ways that people connect ground and shield in USB. In basically all cases though, they are tied together to earth ground at least somewhere. And the shield is typically connected to chassis ground, so eventually they will be connected. USB is, essentially, never an isolated connection.
@Clough42
@Clough42 2 года назад
Shield ground is probably a better term for the USB cable, but yes, they get connected somewhere eventually.
@notsonominal
@notsonominal 2 года назад
The shield should only be connected to ground at one end normally, but it also wasnt the only path.
@mith5168
@mith5168 2 года назад
And I thought you were going to show us a Fusion add-on for Pareto Analysis… maybe next time? Two givens for my projects> 1. Its always Something… 2. And usually not exotic.
@cjtroutt8092
@cjtroutt8092 2 года назад
James Marry Xmas to and the Family. On my plasma system I put the work clamp to the sheet that I am cutting I did the table thing and get ark spikes that would shut the computer off it was isolated system I seen my friend system in his shop and ask him about how he was connected the work clamp to the steel directly and then he said the spikes would reset or shut down his computer. The light bulb 💡 on yaaaaa since then my table been running flawless for 10 years.
@repairtech9320
@repairtech9320 2 года назад
Carbon is conductive too. Not a good conductor but conductive none the less.
@Clough42
@Clough42 2 года назад
PETG is not, however. Which is why the part reads open circuit.
@repairtech9320
@repairtech9320 2 года назад
@@Clough42 True. I was expecting a high resistance reading but not OL. Glad it worked. Great videos BTW. I'm very jealous of all your tools.
@LocnavLivoc
@LocnavLivoc 2 года назад
When I was very very young my parents had some decorative candles for the Christmas tree. And, in my mind, candles should burn, no? Otherwise they wouldn't be candles. So I "fixed" my parents' mistake... And then I couldn't sit right for a week...
@grumpyoldman5368
@grumpyoldman5368 2 года назад
Seems that Langmuir has made a poor choice by not providing isolation for the torch height circuit. Mesa (common hardware supplier with linuxCNC) has a fully isolated THC input board which eliminates this issue for systems using their hardware. Thanks for confirming that it is better to build and know what you have than trust others to design safe and robust systems.
@rennkafer13
@rennkafer13 2 года назад
The torch height circuit was isolated until James inadvertently connected them. Doesn't seem like a design flaw to me. Glad you're happy with what you have, no point bashing others though.
@Clough42
@Clough42 2 года назад
I think this is probably right. A true differential input with enough allowable offset to accommodate the open circuit plasma voltage would solve this
@Clough42
@Clough42 2 года назад
The torch circuit was isolated, but the input to the controller is not. If it were, grounding the plasma circuit would not matter.
@rennkafer13
@rennkafer13 2 года назад
@@Clough42 agreed, but 1) it's the cheapest table you can buy, and 2) it was fine until modified. As delivered it does the job it was intended for safely. There's no way Langmuir can plan for every possible owner mod at the price point they sell at. I doubt the $50k machines are entirely fool-proof. Anyway, Merry Christmas James!
@grumpyoldman5368
@grumpyoldman5368 2 года назад
@@rennkafer13 If the input circuitry was actually isolated from the rest of the controller, connecting them would not have caused any issue. Having to rely on plastic washers to keep the controller isolated from the frame of the machine it runs is a poor design choice, probably just a miss during design, but when discovered the fix should have been proper isolation of the input not plastic washers. A similar choice was Ford Pinto runabout gas tanks and bumper bolts. not a robust design, but fine if nothing unexpected happened. In this case it is lucky that the reading was zero instead of damaging the plasma machine or wiring. Mesa's board is $70 in singles, the parts can't be more than half that. That table is $1500, the THC control option is another $550, maybe it should be $600 with real isolation. $2100 vs $2050? I would be happy to pay that difference.
@sunuk1915
@sunuk1915 2 года назад
Oho so sad 😔
@GregCormier
@GregCormier 2 года назад
What's the model of the Asus touchscreen?
@Clough42
@Clough42 2 года назад
Link in description. Unfortunately prices have risen since I bought it.
@GregCormier
@GregCormier 2 года назад
@@Clough42 darn, either in short supply in Canada or perhaps there is a newer model I'll try to find later. Would be great for my CNC!
Далее
First Cut on the Langmuir Systems CrossFire XR
25:15
Просмотров 43 тыс.
We will see who will do it better 😂
00:14
Просмотров 2,7 млн
شربت كل الماء؟ 🤣
00:31
Просмотров 12 млн
Tips
22:31
Просмотров 3,1 тыс.
The Langmuir Crossfire Pro Is A MONEY MAKER!
15:09
Просмотров 46 тыс.
High Speed Parting with CARBIDE in a Small Hobby Lathe
13:21
Langmuir Systems CNC Plasma 1 Year Review
11:40
Просмотров 29 тыс.