Agni fire Alarm Panel (Working and installation) by Green Tech Solutions | Agni Smoke Detector 

Green Tech Solutions
Подписаться 65 тыс.
Просмотров 134 тыс.
50% 1

Опубликовано:

 

27 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 126   
@prustycreation7619
@prustycreation7619 2 года назад
I'm appreciate 🙏this video.. For help how to installation🔥 fire alarm system...
@baliramdigitech
@baliramdigitech 3 года назад
Bahot badhiya sir aapka latest video Fiber wala IP camera specially bahot badhiya aur latest ❤️
@GreenTechSolutions
@GreenTechSolutions 3 года назад
Thanks sir
@Anonymous-gq5ow
@Anonymous-gq5ow 5 лет назад
Thanx sir Boht hi helpful hai ye video hamare liye Keep it up and go ahead
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Thanks for appreciation!
@Abhi_Gupta88
@Abhi_Gupta88 4 года назад
Hi Very well explained Our Agni Fire alarm panel shows zone 2 short What does it mean There are two detectors in it. One of the detector is not blinking
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Detector wire is short Plz change Detector and check
@sachinbhatt7926
@sachinbhatt7926 Месяц назад
Is panel k sath hum kya heat detector ko jod skte hai smoke detector ki jagah pe ?
@navnath4086
@navnath4086 2 года назад
Sir hi call point 3 zone ke 3 laga sakte kya wahi floor pe
@GreenTechSolutions
@GreenTechSolutions 2 года назад
Hanji you can use mcp in every zone
@Himanshu_Lavania
@Himanshu_Lavania 2 года назад
What is benefit of this product ???
@GreenTechSolutions
@GreenTechSolutions 2 года назад
Gives alarm when smoke start Prevent from fire
@nikunjdabhi8957
@nikunjdabhi8957 5 лет назад
Good teaching
@mdshahzadraza6713
@mdshahzadraza6713 5 лет назад
Awesome you and your video
@celsojoven3525
@celsojoven3525 3 года назад
Sand pedro city of laguna
@sofiulalum5472
@sofiulalum5472 4 года назад
Nice brother
@prameshcctv3668
@prameshcctv3668 Месяц назад
Ek zone me kitna detector add kar sakte hai bhai
@Dj_Sohit_Jyoti_Linderpur
@Dj_Sohit_Jyoti_Linderpur 2 года назад
Mene Ye Job Kari He me ish job ko kar sakta hu agar karni he to batana
@krishnakavalinge1134
@krishnakavalinge1134 4 года назад
Raval somok didctar ka chanisan kese karte he aur system sensor aur apollo ka karte he sir je please reply searching
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Let me check bhai
@ayushpal3390
@ayushpal3390 3 года назад
Nice
@navinmarchattiwar2881
@navinmarchattiwar2881 Год назад
Sir mai Fire Alarm Installation Work karta hu, Installation Work Ho to bataye
@GreenTechSolutions
@GreenTechSolutions Год назад
Ok sir
@farooqalikhan7126
@farooqalikhan7126 4 года назад
Where we can buy ,pls provide link
@GreenTechSolutions
@GreenTechSolutions 4 года назад
You can buy it on Amazon or Flipkart Or you can directly go to Agni devices website
@nurazman5163
@nurazman5163 3 года назад
How to function short circuit marine isolator (55000-721 MAR)
@maankumarmaankumar8138
@maankumarmaankumar8138 4 года назад
Tnks sir
@amitpatni9530
@amitpatni9530 3 года назад
How could we know + or - in smock sensor
@GreenTechSolutions
@GreenTechSolutions 3 года назад
It is always written on detector and also on user manual
@prakashbadwaik5871
@prakashbadwaik5871 4 года назад
Alarm panal band karane la tarika bataye sir jisase jisase thodi de ke liye kar sake
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Press silence button on keypad It will stop for some time
@mdtausif9660
@mdtausif9660 5 лет назад
Super
@sujitbagchi9909
@sujitbagchi9909 4 года назад
System sensor beam ditecktar canetion ka bare me boliye
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Ok sir
@MohdNadeem-mq3lj
@MohdNadeem-mq3lj 5 лет назад
Hii DESTINY MANU this is nadeem from new delhi can i get proper traning of all types fire alarm panel please let me know thanks....
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Yes sir you can
@MohdNadeem-mq3lj
@MohdNadeem-mq3lj 5 лет назад
@@GreenTechSolutions sir what's the process to get the training....plz explain
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
There are many institute in Delhi which provide crash course for fire alarm panels and gives all technical details about it.
@MohdNadeem-mq3lj
@MohdNadeem-mq3lj 5 лет назад
@@GreenTechSolutions sir, tell us some best institute in delhi..
@zamirahmed832
@zamirahmed832 4 года назад
I am working as fire alarm technician in Saudi arabia at king Abdullah university for science and technology here we take care system like simplex, est3, autrosafe , vesda , etc I can share you what I learned +966559872853
@ashwin.thakur09
@ashwin.thakur09 4 года назад
What is loop card?
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Loop card use in addressable fire alarm system This is conventional alarm system Loop is basically signal line in which many addressable detectors are connected
@ashwin.thakur09
@ashwin.thakur09 4 года назад
Thanks for your reply
@jantiklejcn9684
@jantiklejcn9684 4 года назад
Please do an English version
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Yes I will Thanks
@tofij....7960
@tofij....7960 2 года назад
Vai sres nhi kya prelalme connect kya
@GreenTechSolutions
@GreenTechSolutions 2 года назад
?
@gopalchdas8532
@gopalchdas8532 Год назад
Agni fire alarm panal a akta problam hocha display ta FIRE ALARM আসছে kintu kono address দিচ্ছে না are field a kono smoke nai tahola ki korbo
@humen1974
@humen1974 5 лет назад
Hello Manu, we want to give smc of fire alarm Frylaast Agni. Reply is you interested.
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
What is SMC ?
@shelendrashelendra7236
@shelendrashelendra7236 4 года назад
9359018732
@kumarbhupender6820
@kumarbhupender6820 5 лет назад
Bhai agar muje ye Kam suru karna ho to apne area me kya karna hoga
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Aapke area main jo installer hoga unke pass kuch time ke liya kaam sikh lo then you can start
@kumarbhupender6820
@kumarbhupender6820 5 лет назад
@@GreenTechSolutions okay sir aap ka kon sa area h
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
@@kumarbhupender6820 kurukshetra haryana
@kumarbhupender6820
@kumarbhupender6820 5 лет назад
@@GreenTechSolutions aap ka no. Mil Sakta h kya
@samsadansari6793
@samsadansari6793 4 года назад
1 zone me kitne Detector Laga Sakte Hai....?
@GreenTechSolutions
@GreenTechSolutions 4 года назад
12 detectors
@GreenTechSolutions
@GreenTechSolutions 4 года назад
NC = Normally close NO = Normally open
@shelendrashelendra7236
@shelendrashelendra7236 4 года назад
159 take
@bkhrangkhol5799
@bkhrangkhol5799 5 лет назад
Fire alarm panel isolate seh heldi me k se rakte he
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Did not understand your question
@kayumkhaninjoyatozkhan8744
@kayumkhaninjoyatozkhan8744 4 года назад
Agni smoke detector cannectoin and ri bhi
@ashrafulashraful9219
@ashrafulashraful9219 4 года назад
sar panel ma kasa koneshon kartahi thankyou
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Series connection
@zamirahmed832
@zamirahmed832 4 года назад
Class B
@Muskbuck
@Muskbuck 5 лет назад
Why we are using resistance in last of zone
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
To complete the circuit Only than it works proper.
@naveenkumar-zz1dd
@naveenkumar-zz1dd 5 лет назад
If u are not contact the resistance so panel show open circuit .....
@zamirahmed832
@zamirahmed832 4 года назад
To complete the circuit ...resistor allow to flow the little amount of current and FACP read that current flow for confirmation that circuit is completed all devices are connected In FACP fixed limits of current flow for different type monitoring For example no current flow means circuit open low current flow means system normal High current flow means alarm Very high current flow means short circuit
@manojkashyaprajputkhaira7162
@manojkashyaprajputkhaira7162 5 лет назад
well discribed
@ammulala9577
@ammulala9577 5 лет назад
1 zoon available hai kya
@ammulala9577
@ammulala9577 5 лет назад
Bhai
@luckykumar2724
@luckykumar2724 2 года назад
Hi
@vijaygajjar9482
@vijaygajjar9482 4 года назад
How much price of this unit ?
@GreenTechSolutions
@GreenTechSolutions 4 года назад
12000 Approx
@mdshahab2965
@mdshahab2965 5 лет назад
Bhai fire alarm system me technician se interview me kya puchhta h any tips
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
For Installation purpose He should know the series connection and also know about 12/24 volt system
@mdshahab2965
@mdshahab2965 5 лет назад
I want to talk with you but how😢??
@zamirahmed832
@zamirahmed832 4 года назад
Basic sawal puchte hain Q:- Fire alarm system kitne type ke hote hain? Ans - conventional, addressable, intelligent, wireless Q -: conventional aur addressable me kya fark hota hai ? Ans - conventional system me sirf zone ka pata chalta hai ki kis zone me detect hua hai fire. Exactly pata nahi chalta ki kis office kis room me ya kaun se area me fire hua ye chote office ya ghar ke liye use karte hain jahan kam area ho to asani se pata chal jayega Addressable system me exact LOCATION ka pata chal jata hai kis room ya area se trigger hua hai Q - fire alarm system me kitni tarah ki wiring hoti hai Ans. 2 type. Class A. Class B Class A me wiring PANEL se nikal kar sare device connect hone ke bad wapas PANEL me aa kar connect hota hai Class B me PANEL se nikal kar last device par EOLR end of line resistor laga ke band ho jata hai Control module. Aur monitor module ka use kis liye aur kahan kahan hota hai ? Control module ka use kisi dusre system ko fire alarm system se integration ke liye hota hai. Jaise ki AHU , FANS , elevator, glass doors , access control, barrier etc. In system ko fire case me on ya off ya bypass karne ke liye CM ka use hota hai. Aur horn strobe ya NAC circuit active karne ke liye bhi hota hai Monitor module ka use kisi aur system ko FACP me duara monitor karne ke liye hota hai. Jaise preaction system, fm200 or novec , vesda , flow switch , tamper switch , zone control valve etc
@ismaila156
@ismaila156 5 лет назад
Shall I get this job
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Yes you can Just take a knowledge for fire system etc And there are many companies who offer for the fire safety specialist
@ismaila156
@ismaila156 5 лет назад
Thank you
@ammulala9577
@ammulala9577 5 лет назад
Bhai 1 zoon ka panel hai kya
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Minimum 2 zone
@mdshahab2965
@mdshahab2965 5 лет назад
I want to talk with you but how😢??
@sitaramfirealarmsystemtech2643
@sitaramfirealarmsystemtech2643 2 года назад
Hiu
@thinkpositive3887
@thinkpositive3887 5 лет назад
MCP pe no reset ka switch hai Us se fire panel ko reset hota hai kay
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Konsi company ka fire Alarm Panel h
@ganeshwarghadepatil29895
@ganeshwarghadepatil29895 4 года назад
Aur mehnat kr beta tuze our bhi sikhna padega😄😄
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Hanji sir, Thanks
@ammulala9577
@ammulala9577 5 лет назад
Fire panel
@GreenTechSolutions
@GreenTechSolutions 5 лет назад
Bhai minimum 2 zone ka aata hai
@nasiadomary4893
@nasiadomary4893 4 года назад
Language problem
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Sorry for that
@nasiadomary4893
@nasiadomary4893 4 года назад
But its not an end You have opportunity to learn sir.
@arshadulislam8039
@arshadulislam8039 3 года назад
Conventional hai
@GreenTechSolutions
@GreenTechSolutions 3 года назад
Yes
@arshadulislam8039
@arshadulislam8039 3 года назад
@@GreenTechSolutions SIR WILL YOU UPLOAD ADDRESSABLE
@GreenTechSolutions
@GreenTechSolutions 3 года назад
Yes I will
@arshadulislam8039
@arshadulislam8039 3 года назад
@@GreenTechSolutions thank you which company
@GreenTechSolutions
@GreenTechSolutions 3 года назад
Morley/ceasefire
@vindashchennal3461
@vindashchennal3461 2 года назад
Job dila do sar please
@aniketgaikwad1316
@aniketgaikwad1316 4 года назад
Hey, we have gone through your product (Fire Alarm System). Our company is interested in your product. Can we have a Formal discussion. Please revert me back. Thank you.
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Yes sir 9354444290
@udayalure544
@udayalure544 3 года назад
Hii sir this is uday here we are also fire alarm panel provider so shall we speak once my number 6362459535 please call me once .
@sachin.agrahari94
@sachin.agrahari94 4 года назад
Mai qya puch rha hun aur tu qya bta rha h ? Made !
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Bhai sahab kahna kya chahte ho ??
@HANUMANTHU.130
@HANUMANTHU.130 3 года назад
Telugu lo chappu sae
@sachin.agrahari94
@sachin.agrahari94 4 года назад
Teri bat bilkul smjh ni aayi re.
@GreenTechSolutions
@GreenTechSolutions 4 года назад
Bhai kya nahi smjh aaya
@willipine1863
@willipine1863 4 года назад
bad presentation
@technicalcharcha4490
@technicalcharcha4490 5 лет назад
Nice
Далее
Fire Detection and Alarm System
20:18
Просмотров 209 тыс.
ИСТОРИЯ ПРО ШТАНЫ #shorts
00:32
Просмотров 286 тыс.
Nightmare | Update 0.31.0 Trailer | Standoff 2
01:14
Просмотров 584 тыс.
What is a Fire Alarm System?
11:06
Просмотров 2,1 млн
25 - Control Modules - Introduction to Fire Alarms
10:00
ИСТОРИЯ ПРО ШТАНЫ #shorts
00:32
Просмотров 286 тыс.