Тёмный

Airxcel Maxxfan 4500K Smoke Fault 

Adam Sherman
Подписаться 196
Просмотров 220
50% 1

The lid mechanism works fine, but if you hit the ON/OFF button the fan starts spinning momentarily before the beeping starts, the fan shuts off, and the lid closes. It beeps ten times and the green light blinks. I have a multimeter hooked up at the fan to show the voltage, which is normal. The rain sensor is not the issue as I can open the lid and wet the sensor, which closes the lid.
This is an Airxcel Maxxfan 4500K RV roof vent with built in fan that runs on 12V and can be used in enclosed trailers, vans, etc.

Авто/Мото

Опубликовано:

 

4 май 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 6   
@williamrussell1764
@williamrussell1764 2 года назад
Thanks for the fix
@williamrussell1764
@williamrussell1764 2 года назад
Mine does the exact same thing. So is there a fix ? New circuit board ? Disconnect/reconnect power ?
@adamsherman
@adamsherman 2 года назад
I needed a new motor. Airxcel sent me two controller boards, since the first one didn't fix the problem, and then a motor-which was the fix. It's an overcurrent problem.
@grant1075
@grant1075 4 года назад
Did you figure out a fix? My new 10 speed manual open is doing the same.
@adamsherman
@adamsherman 2 года назад
Sorry, I didn't see your comment. The fix was a new motor from Airxcel, as the issue was overcurrent from the motor.
@adamsherman
@adamsherman 2 года назад
But if it’s a manual open, what is it doing?
Далее
MaxxAir MaxxFan Roof Vent full Tutorial & Review
10:21
1HD-T Engine in an HDJ81
1:56
Просмотров 43 тыс.
Каха и суп
00:39
Просмотров 1,4 млн
Why This Combat Knife Terrifies Me
15:22
Просмотров 51 тыс.
KingTech K45G4+
1:03
Просмотров 153
Hot Girl Drives a Land Cruiser 😉
0:54
Просмотров 207
NullTurbo - Compressor 1/8 Speed Test.
0:39
Всегда проверяйте зеркала
0:21
Просмотров 215 тыс.