Тёмный

AM2/S GN3 Test procedure with safe isolation AM2 help apprentice 121 

Mark The Sparky Allison
Подписаться 13 тыс.
Просмотров 6 тыс.
50% 1

I do my best to run through safe isolation and a full set of testing on a radial circuit. With a look at filling in the test results.
I am not a teacher! This is not instructional just an effort to help and probably full of mistakes so buyer beware lol!
Hope it helps one or two out.
Please check out the A121 podcast here for audio only help on AM2 and GN3! open.spotify.com/show/0yaVnUV...
Also feature the TIS MFT pro and TIS 859 voltage indicator. Not paid, donated or sponsored. Just my own! www.testinstrumentsolutions.c...

Опубликовано:

 

7 мар 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 11   
@deanbull4347
@deanbull4347 3 года назад
Very well explained, I’m doing my AM2 this year. Thanks for the help!
@ifyougetstucklookitup237
@ifyougetstucklookitup237 2 года назад
Thank you again appreciated. Making more sense as I work my way through year 2 at college.
@electrician247
@electrician247 2 года назад
Thanks and keep on trucking!
@seandempsey9396
@seandempsey9396 3 года назад
Always a joy to watch
@seandempsey9396
@seandempsey9396 3 года назад
Just two points, firstly for safe isolation you should probe onto the least dangerous terminal first ie onto neutral then onto line / of line of neutral onto earth onto neutral of neutral of earth onto earth onto line, the earth conductor has always been and always will be called the earth conductor it is only college teachers who call it the CPC 😁and the cable is called flat twin and earth NOT pvcpvc twin and cpc. Also you don't have to null the test leads but you will need to deduct the leads resistance from the test result Great video mate. Well executed. Thank you.
@electrician247
@electrician247 3 года назад
Lol thanks sean. I was doing my best to talk in modern college talk. Its hard because like yourself I have spent years calling it twin and earth. Done my best mate. Its hard as hell trying to remember stuff on camera. Not comfortable at all for me these kind of videos as yet!
@seandempsey9396
@seandempsey9396 3 года назад
@@electrician247 yes I know what you mean, but I think you did a dam good job
@homeschoolelectrics4323
@homeschoolelectrics4323 3 года назад
Thank you.
@daveschwarz5279
@daveschwarz5279 3 года назад
When l did my AM2 l had to remove the cover of the light fitting and test for voltage there... l failed this unit the first time because l forgot to test for voltage by switching the light switch on....
@alecturner2008
@alecturner2008 3 года назад
Maybe not relevant to AM2 on fixed installations, but when making safe it might have been worth mentioning that even equipment that is supplied via a plug in supply, lock off can be achieved using a box for the plug. More common on 3 phase equipment in industrial environments maybe.
@electrician247
@electrician247 3 года назад
Very good point. I didnt want to make it to instructional. More encourage people to learn the process etc. I did cover locking off on another video and mentioned plugs. Its hard to remember everything lol. Thanks for the suggestion, appreciate it Alec.
Далее
Угадай МОБА 1 🥵 | WICSUR #shorts
01:00
Просмотров 688 тыс.
КРАСИМ ДЕНЬГИ В РОЗОВЫЙ!
01:01
Просмотров 337 тыс.
RING FINAL CONTINUITY AM2 and/or AM2S Training
6:33
Просмотров 38 тыс.
Earth fault loop impedance testing - ZS
9:32
Просмотров 14 тыс.
Угадай МОБА 1 🥵 | WICSUR #shorts
01:00
Просмотров 688 тыс.