(Analog signals)How to program an analog (input/output) and simulate it on TIA portal (S7-1200)PLC 

B Electric "How to automation tutorials"
Подписаться 4,7 тыс.
Просмотров 12 тыс.
50% 1

you will learn in this video
what is the meaning of normalize and scaling
how to program an analog input or output
how does PLC deal with analog signals
how to simulate it

Опубликовано:

 

10 ноя 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 21   
@alobalo3796
@alobalo3796 23 дня назад
Thank you the easiest explanation
@balachanderbalachander6959
@balachanderbalachander6959 3 года назад
more thanks sir. you have very good technical backround , really happy to follow you, in utube more people making confusing but you are great. continue sir
@niryashk9197
@niryashk9197 3 года назад
Awesomely explained 👍👍👍👍
@masumahmed7978
@masumahmed7978 Месяц назад
nice
@aleemahsan4730
@aleemahsan4730 3 года назад
Very Well explained. Thank you
@binyameen.pkondotty
@binyameen.pkondotty Год назад
Very good explanation. Thank you
@athilaldurry5880
@athilaldurry5880 3 года назад
Very good information many thanks
@athilaldurry5880
@athilaldurry5880 3 года назад
Many thanks for wonderful information
@rashidchibvuri2036
@rashidchibvuri2036 5 месяцев назад
Thank very much sir ❤❤❤
@B.electric
@B.electric 5 месяцев назад
you are welcome
@falconiraqi5604
@falconiraqi5604 5 месяцев назад
🎉🎉🎉
@vishals11
@vishals11 3 года назад
video is definitely helpful screen view need to closer to viewer you explain why and how to choose particular instructions.
@B.electric
@B.electric 3 года назад
Thank u for your opinion i will take care about this points in the next video
@vishals11
@vishals11 3 года назад
@@B.electric waiting for next video .
@alearnerforsafety3692
@alearnerforsafety3692 2 года назад
Dear sir, I have SIMATIC S7-1200 and a Signal Generator Device and I use the NORM_X and SCALE-X functions in the TIA Portal program V 15 . The MIN value of NORM_X is 0.0 and the MAX is 27648.0 . It’s assumed that I use a RTD (PT100) with the Temperature Transmitter ranges ( -100 ˚C to 800 ˚C) and its output is 0-10 VDC. The output of NORM_X function is sent to two SCALE_X functions: one to scale the Ohms and the second to scale the temperature values. I depended on the RTD Temperature VS. Resistance Table to get the MIN and MAX values for these two scale functions. The first scale function which is for Ohms the MIN value is -100 ˚C whereas the MAX is 800 ˚C and the MIN value for the second scale function is 60.26 Ω and the MAX value is 375.7 Ω ( Because -100 ˚C is equal to 60.26 Ω and 800 ˚C is equal to 375.7 Ω in the reference table). But when I inject the following volt values in the Analog input of the PLC the output values of the Two SCALE_X functions are not as shown in the table?! Examples: 1- At 2.5 V the output of the first SCALE_X function is 124.4141 ˚C and the output of the second SCALE_X function is 138.91 Ω but in the Reference table when the Temperature is 124 ˚C the Ohms must be 147.58 Ω. 2- At 5 V the output of the first SCALE_X function is 349.93 ˚C and the output of the second SCALE_X function is 217.9 Ω but in the Reference table when the Temperature is 349 ˚C the Ohms must be 229.36 Ω. 3- At 7.5 V the output of the first SCALE_X function is 575.488 ˚C and the output of the second SCALE_X function is 297.0111 Ω but in the Reference table when the Temperature is 575 ˚C the Ohms must be 305.63 Ω. Why are the SCALE_X outputs not the same as what they must be as in the reference table?! And what must I do to make the outputs the same as what is shown in that table?! Thank you and I’m waiting for your reply.
@josefd4326
@josefd4326 2 года назад
Good video thanks! Only "bad" is music too loud. Maybe turn volume down? Thank you!
@kareamsultan2247
@kareamsultan2247 2 года назад
ممتاز وهل في فيديو خاص بال flow meter وعمل ال totalize؟
@B.electric
@B.electric 2 года назад
انشاء الله في المستقبل سوف اقدم فديو عن الفلو ميتر
@aded719
@aded719 3 года назад
من لهجتك مصري 😂😂😂😂😂
@mahmudmohammed7155
@mahmudmohammed7155 3 года назад
الحقيقة مش واضح شكرا
@Gaza.moh1
@Gaza.moh1 3 года назад
Zs waat we leren in zs video ..,, (work on ur English please)
Далее
TIA Portal: Analog Processing / NORM_X and SCALE_X
25:29
Nurse's dream !! 😂😂
00:17
Просмотров 5 млн
FC & FB : YOU KNOW THIS DIFFERENCE !
4:15
Просмотров 7 тыс.