Having mismatched electrical connectors is a huge bummer. This video covers secure installation of huge modular Anderson SB350 (350 amp) terminal housings using a pocket knife, vice, and propane torch for safe and great looking high-power quick connects that can even be hotplugged/unplugged if necessary.

Опубликовано:

 

22 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@KillerJoeFIN
@KillerJoeFIN 4 года назад
You should buy crimping tool for 350amp connector and heatshrink tube with glue. They are not meant to be soldered.
@jasonbrown467
@jasonbrown467 7 месяцев назад
appreciate the video, i just picked up a pair and a 300amp breaker for my 12.8v 300ah lifepo battery that stays in my vehicle, that feeds a 3.5kw psw inverter, that powers a microwave and small portable freezer/fridge, since i work on the road. i want to be able to quickly disconnect the battery and bring it into the house to charge in the winter. summer time charging is done by a small solar panel. i wont be soldering mine, i will be using a hand held hydrolic press. it smashes the metal strands into one chunk of copper
@unclefatbloke687
@unclefatbloke687 Год назад
Can someone please explain to me the benefit of adding solder to a crimp joint? A gas-tight crimp connection is the best mechanical and electrical connection possible. So what does solder bring to the connection?!
@gf2e
@gf2e 2 месяца назад
The benefit is that you don't have to have the correct crimp tool. And you don't have to worry that your incorrect crimp might result in the wire coming loose. EDIT: Apparently, empirical testing suggests that these terminals have lower resistance when soldered: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-TSzUA0T1YD4.html The disadvantage of using solder is that your terminals have a higher resistance, and your wires are more brittle since you have solder wicking up into the wire. I have a cheap hydraulic crimper which is OK. You have to use the right dies, which gets a bit tedious. I also have a hammer crimper which I've only used once or twice. I think I may go back to trying it again. The crimps that it produces don't look at pretty. But, it doesn't require choosing exactly the correct size die. Choosing the correct die sounds easy, but it's not as easy as it sounds. The cheap crimper I have is rated in mm2. My wire is rated in AWG. And I often use ultra-flexible cable, which is actually a bit physically larger at the same AWG. And, crimp terminals can have different wall thicknesses. So, really, if you want to be correct you should be matching your dies and crimp terminals to be from the same manufacturer. Which gets $$$. Indentation crimpers have a range of terminal sizes they work with, so, less concern about precision.
@bowtiebuilding
@bowtiebuilding Месяц назад
I know this is an older video but why would my winch work intermittently when powered by my Anderson quick disconnect? Quick disconnect comes from the battery out to the back of the truck. 12k harbor freight winch
@dr.leespoorlifechoices1701
@dr.leespoorlifechoices1701 Месяц назад
Check for any fouling where the terminals make contact. They generally clean themselves fairly well, but if frequently connected/disconnected under load it wouldn't hurt to clean them and see if that helps.
@ra8620
@ra8620 2 года назад
I will suggest everyone place this one with your front bumper is more worth than . My case my Nissan Micra stuck battery dead nothing open I tried to breached in but fail if I have by pass I just go .
@hughbatchelor8599
@hughbatchelor8599 3 года назад
You should have shrink wrapped the ends. Would have looked way better and professional.
@adeebmarghalani2112
@adeebmarghalani2112 Год назад
Is the 175 amps enough for a jump cable?
@jasonbrown467
@jasonbrown467 7 месяцев назад
you can go over current from time to time, depends on the application. if its going to be used all the time, i would opt for bigger cables. a little bit of loss here and there is no big deal, but if you try to push 300amps through a cable rated for 175, their will be huge losses in the form of heat and could even lead to a fire.
@joshasaurisgood
@joshasaurisgood 5 лет назад
7:00 you could also rtv or heat shrink that area.
@dr.leespoorlifechoices1701
@dr.leespoorlifechoices1701 5 лет назад
That's a great idea -- will have to try that on the next ones.
@gf2e
@gf2e 2 месяца назад
@@dr.leespoorlifechoices1701 I was watching a video from 3M on cable splicing. They had specific techniques for how to handle electrical tape. If I recall - keeping it under tension while wrapping it, and overlapping 50% was what they said to do. I've been much happier with my electrical tape when I stretch it while applying it.
@adairjanney7109
@adairjanney7109 11 месяцев назад
I saw the channel name and have a feeling he is like me we shall see I have made TONS of bad life choices but im not a doctor
@benkanobe7500
@benkanobe7500 2 года назад
I purchased the Anderson 175 amp connectors as they looked like yours. (ooooops!). So now I have my truck running front and rear with AWG 1/0 Copper welding cable off aux battery to run my HF Apex 12,000 winch and also a plug-in 3,500Watt 12VDC to 120VAC inverter (run them separately). My winch seems to work OK. Do I need to cut off my 175 amp Andersons and replace them with the much larger 350 amp Andersons like you have demonstrated here??
@dr.leespoorlifechoices1701
@dr.leespoorlifechoices1701 2 года назад
Your winch should have a chart in the manual that shows max power draw under load. The max ampacity of both cable and connectors needs to meet or exceed the max amp draw of the winch.
@christianjensen3182
@christianjensen3182 2 года назад
The HF 12,000lb badlands winch comes with a 150amp circuit breaker on the positive lead, so I guess that would be the maximum current draw.
@benkanobe7500
@benkanobe7500 2 года назад
@@christianjensen3182 Thank you for the reply as that makes a ton of sense (pun intended). How did you determine the circuit breaker is 150amp? That would mean all the folks using larger than 175amp connectors are wasting their money and I just got lucky. Thanks again as I am out of my wheelhouse with electrical stuff.
@andufuse
@andufuse 2 года назад
Got it.
@benkanobe7500
@benkanobe7500 4 года назад
Where did you get your receiver hitch winch mount? I thought I was going to have to make that myself until I saw yours. Great information and presentation!
@dr.leespoorlifechoices1701
@dr.leespoorlifechoices1701 4 года назад
Thanks! The hitch witch mount is also from Harbor Freight. Nothing special.
@benkanobe7500
@benkanobe7500 4 года назад
@@dr.leespoorlifechoices1701 Thank you!
@abecoulter8550
@abecoulter8550 Год назад
the 350 amp are overkill, they are more designed for electric forklifts
@jordivandermeiren4043
@jordivandermeiren4043 4 года назад
Where can i buy the 350 amp ones ? I am from europe and really need a set for making my amplifier and subs a quick disconnect type deal or do you reckon the smaller version would be fine ?
@dr.leespoorlifechoices1701
@dr.leespoorlifechoices1701 4 года назад
You'll have to do the math on your particular application and figure out which type of connectors and cable gauge are required: there's no way to safely skip that. I usually get mine off eBay, and personally always buy the genuine Anderson housings to make sure they will always mate without issues.
@jordivandermeiren4043
@jordivandermeiren4043 4 года назад
@@dr.leespoorlifechoices1701 cable comes in the kit i bought so that's no problem i just need to know how big of a cable in could fit in the housing.
@dr.leespoorlifechoices1701
@dr.leespoorlifechoices1701 4 года назад
@@jordivandermeiren4043 Right but the connector you put on the ends of the wires has an amperage rating, so it's not just the cable gauge that matters but also not exceeding the rating of the connector metal. Just take the max amps you'll need and get the connectors and housings the next closest size up. If you want to buy from Powerwerx (I'm not affiliated but have used them) they will help you find the right type.
@jordivandermeiren4043
@jordivandermeiren4043 4 года назад
@@dr.leespoorlifechoices1701 all right thank you
@patrickdk77
@patrickdk77 4 года назад
@@jordivandermeiren4043 It all depends on the cable size. The connector is rated upto the max amps the cable can handle for the max size that fits into that connector. Using it on an audio system, you won't be drawing the power 100% of the time, so you can get by with burst loading the connector. If you look at the pulse current graph you can see how long and what size cable it can handle. Note that a 350 connector cannot handle 350amps if you use something smaller than 350mcm cable. www.nooutage.com/pdf/Andeerson-SB350.pdf
@jeffrees9994
@jeffrees9994 2 года назад
No this is not correct
Далее
Unleash the Power of Anderson SB Connectors
30:42
Просмотров 20 тыс.
Soldering Large Anderson Style Connectors
20:59
Просмотров 65 тыс.
How to Wire a 50 amp Quick Connect Plug
7:21
Просмотров 47 тыс.
Winch Wiring Quick Disconnect!
10:48
Просмотров 15 тыс.
What Connector To Use For MC Cable
2:15
Просмотров 6 тыс.
24v Travel Buddy Oven | Anderson plug swap
14:55