Тёмный
No video :(

Aux Inverter AC Error Code // How To Solve Error Codes //Solutions For Error Codes / Error Code List 

Easy To Learn Tech
Подписаться 10 тыс.
Просмотров 45 тыс.
50% 1

Опубликовано:

 

19 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 113   
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 5 месяцев назад
Unlock exclusive AC maintenance solutions by joining my RU-vid membership today! Get access to expert tips, troubleshooting guides, and more. Don't miss out! ru-vid.com/show-UCjUFtXZ-oMCNht6Icj6R6NQjoin
@mylenesagarang3565
@mylenesagarang3565 2 года назад
Thanks for the information! I support you! Keep it up! God will bless you more and more!😊🙏
@hassanavasavas6053
@hassanavasavas6053 2 года назад
Really thanks maaan u deserve millions like 👍 for this learning vid ❤️❤️👍🌷
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
Thanks a lot 👍👍
@euphoricladyb
@euphoricladyb 2 года назад
Wow. Thank you for this info. I will get back here if i really needed..
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
Thank you so much, I am glad you like my video ☺️ Thanks for Appreciating, please keep supporting.
@ayesha_mixedrecipes
@ayesha_mixedrecipes 2 года назад
Thanks good information about it
@davelemuelvarquez8030
@davelemuelvarquez8030 2 года назад
Thank you for sharing this informative vedio
@georgejpchannel6730
@georgejpchannel6730 2 года назад
Thanks you for information
@trickytrendygadgetz
@trickytrendygadgetz 2 года назад
Very knowledgeable
@iamnobody9919
@iamnobody9919 2 года назад
thanks s info lods
@danielnwobodo6092
@danielnwobodo6092 2 года назад
Nice one
@leejee6172
@leejee6172 2 года назад
Nice video
@gingerbruner9646
@gingerbruner9646 Год назад
Im not getting an error code but they unit does shut off before desired temp and the temp display on the unit flashes once every ten seconds or so. It comes back on after 5 or 6 minutes. I feel like this isnt how its supposed to work but I can not find anything online. Just purchased last winter. It also doesn't seem to be blowing warm air. I know its a lot, but you are the first person to discuss this particular model that i have been able to find.
@gingerbruner9646
@gingerbruner9646 Год назад
Im wondering if the remote is set wrong. I know I'm overthinking. Any suggestion is much appreciated.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
Hi, Thanks for the opportunity. 1) Are you getting proper temperature from your ac, room is getting cool or not.
@gingerbruner9646
@gingerbruner9646 Год назад
1st year using it Temp never really has reached but it did warm some and on cool it continually cooled no matter what temp was set on. Had to turn off to get it to stop cooling. Didnt use it for a while due to not working anyway. Tried again recently and now no cooling, or heating at all, just blows air. I'm beyond frustrated. Had it too long to take it back. Nobody in my area works on them. Worked for 1 season but not properly. UGH
@gingerbruner9646
@gingerbruner9646 Год назад
PLEASE ADVISE
@gingerbruner9646
@gingerbruner9646 Год назад
No error code. Indoor display did flash 1x every eight seconds randomly but not code.
@fazalvlogs7836
@fazalvlogs7836 2 года назад
Thank you for info
@susanvillegas3825
@susanvillegas3825 2 года назад
Nice video, keep it up 😁
@fullbridgeelectric
@fullbridgeelectric Год назад
Mostly E5 error code come from outdoor unit PCB. Mainly reason is power supply to the outdoor unit. Before checking the PCB you must check the motor unit. If short to the windings or short to the ground.
@Hi-levels
@Hi-levels 10 месяцев назад
What do you mean? Fan motor in outdoor unit? Or compressor motor?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 10 месяцев назад
In the compressor we don't have a motor.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 10 месяцев назад
The compressor is divided into 2 parts, electrical winding & mechanical parts.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 10 месяцев назад
For which error code you're asking please let me know.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 10 месяцев назад
@vankedisi1 which error are you facing brother
@sudeshputran69
@sudeshputran69 Год назад
Super
@MR_ASRAF7
@MR_ASRAF7 2 года назад
Op👍
@griemeheatandair5773
@griemeheatandair5773 2 года назад
I am getting an E0 code. I'm getting 249v out of main panel breaker to unit. Is that OK, or what can this unit handle/ rated max for? Thank you.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
Sorry for late reply, i saw today now what is the condition of your AIRCONDITION.
@user-qv3xw2ru3k
@user-qv3xw2ru3k 2 года назад
Peace be upon you, my brother, I am Abu Marwan from Saudi Arabia. I have an Aux air conditioner that has the PE code in it. What does this mean?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
Walaikum assalam
@arneilbaldonadi9050
@arneilbaldonadi9050 2 года назад
Kialhe' bai!
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
Means
@bayanicruz6319
@bayanicruz6319 9 месяцев назад
What is meant by cl appearing in the screen and how to solve it?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 9 месяцев назад
Did you put any child lock?
@maldivesmalework945
@maldivesmalework945 Год назад
Indoor unit pcb fault ya outdoor unit pcb fault Aux E5
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
Indoor outdoor communication fault
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
Check the communication between indoor & outdoor unit. Check the communication dc voltage, indoor out & outdoor out communication dc voltage. Dc voltage should be around 9 to 45 dc voltage in running.....
@lort_prodisz
@lort_prodisz 10 месяцев назад
how adaptation new copresor bldc to inverter - copresor starting 4sec and have overcurent error ...
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 10 месяцев назад
Check the Dc current which is going to the compressor, is not stable. A bridge rectifier in an outdoor pcb card has an issue. Change the outdoor PCBs card or repair the PCBs card.
@lort_prodisz
@lort_prodisz 10 месяцев назад
@@Rehankhan_HVAC_TIPS the electronics are 100% OK, I have an old compressor and it works - the new one must be adapted to the inverter. I tested the new one on an industrial bldc inverter - OK
@griemeheatandair5773
@griemeheatandair5773 2 года назад
I am getting E0 code.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
This error code occurs on your air conditioner due to various reasons. It could either be due to an outdoor PCB defect, clogging of the refrigerant piping system, an outdoor compressor motor lock, insufficient refrigerant, or an outdoor compressor start-up error.
@mranbe903
@mranbe903 2 года назад
Hello bro one help my ac E5 codes view solutions tell me brother
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
E5 error means communication failure between indoor & outdoor unit. Step 1 = need to check cable for communication. Step 2= need to check indoor PCBs card & outdoor PCBs card may be faulty.
@mranbe903
@mranbe903 2 года назад
Thank you bro new AC brother last one month letter power problem this code problem bro
@fullbridgeelectric
@fullbridgeelectric Год назад
See my description on the comment
@CherryIofficial
@CherryIofficial Год назад
there is no error code even fan is running in the head and also in the outdoor unit, but looks like the compressor is not running and on the pcb board three LEDs are blinking, can you please tell what is the problem?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
1st need to check the gas pressure or Ampere for compressor. Need to check refrigerant first.
@maldivesmalework945
@maldivesmalework945 Год назад
E5 aux eror outdoor unit not on
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
E5 error: Abnormality of outdoor unit
@CJ-vg4tg
@CJ-vg4tg 2 месяца назад
Hi. If I disconnect the outdoor unit and measure the indoor unit N to S and it reads 24v DC but no fluctuation does this mean it is still ok or should it be fluctuating? E5 error code. Thanks!
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 месяца назад
1. Firstly, the IDU and the ODU should be matched and connected properly. 2. Observe the main external control panel, turn on the air conditioner, three lights are all lighted up then off and the relay pulls in. If not, it is power supply problem. 3. Connect the black signal line S to terminal N of ODU. Turn on the A/C, if "E5" is still reported, the main external control panel need to be replaced. If "E5" is still reported at this time, go to step 4. 4. Change a new main internal control panel, if the error code E5 remains, then the problem should be on the main external control panel.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 месяца назад
There will be no Fluctuations, because you have removed the communication cable from the outdoor unit. Only one side of communication is receiving That's why it will not fluctuate.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 месяца назад
Did you check the outdoor unit N to S, after disconnecting the S from the outdoor unit. What is the voltage from the outdoor side?
@CJ-vg4tg
@CJ-vg4tg 2 месяца назад
​​​@@Rehankhan_HVAC_TIPS brilliant. Good to know thanks. I will check the signal from the outdoor unit with it disconnected from the indoor shortly. Thanks for your rapid reply. I also have 2 of the identical units working correctly so can compare values. It did initially trip the circuit breaker before the E5 occurred.
@CJ-vg4tg
@CJ-vg4tg 2 месяца назад
​@@Rehankhan_HVAC_TIPSJust checked it and no DC voltage from S on the outdoor unit. Worth checking the fuse on the odu? Or is it pretty much dead? I'll remove it and have a look in a day or 2. Don't have easy access to it. 👍
@obheymatienzo7359
@obheymatienzo7359 Год назад
How about L7?
@daisyalonzo3892
@daisyalonzo3892 Год назад
F1 error code on an Aux inverter
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
Outdoor unit INVERTER POWER MODULE (IPM) FAULTY. If you can repair from somewhere, otherwise you need to change the outdoor PCBS card.
@kaushikmakwana4337
@kaushikmakwana4337 Год назад
Are BHai handi me batav na
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
Are Bhai kiya hua bolo
@griemeheatandair5773
@griemeheatandair5773 2 года назад
I am getting an F4 error code on a confortotal. what is this code
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
On which brand ac your getting the problem
@griemeheatandair5773
@griemeheatandair5773 2 года назад
confortotal. it was installed new and working. later that day it popped up an F4 code.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
Outdoor mid coil temperature sensor open/short.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 года назад
1) Check for gas pressure, may be leak. 2) outdoor mid coil temperature sensor open/short. 3) PCBS CARD MAY BE FAULTY. THIS ARE THE REASON FOR F4 . if its newly installed, please try for replacement or spare parts change. If warrant/guarantee is claimed in that region. Please let me know Thanks
@ShahidKhan-kp7gu
@ShahidKhan-kp7gu 10 месяцев назад
Aux error code L6 ??
@jasonhoyt6287
@jasonhoyt6287 Год назад
f7. what's this mean. it's when I try to use heat
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
When the air conditioner is switched on, if the compressor is not running but there is an alarm of "OVP or UVP error , then it shows the error f7
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
In cool mode does the unit work normally ?
@kathymaeroxas4143
@kathymaeroxas4143 Год назад
What is LD means?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
In general, the LD error code could indicate issues with the indoor unit's fan motor, temperature sensor, or electronic control board. One common cause of the LD error is a malfunctioning temperature sensor, which can prevent the air conditioner from regulating the room temperature correctly.
@muhammadafif9907
@muhammadafif9907 Год назад
I am getting F6
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Год назад
F6 : external temperature sensor error, 1. Check whether there’s resistance problem, short circuit or open circuit in the sensor; the resistance value shall be within a reasonable range (15KΩ under the temperature of 25℃). 2. Check whether the sensor wire is broken. 3. Check whether the terminal connectors are well fixed; check whether the weld between the terminal and the main control panel is loose, and pull the terminal slightly for inspection if necessary. 4. Check whether the sensor is affected with damp. 5. In case no standard sensor is available at present, replace the external temperature sensor with the other sensor asides, and then check whether the error still exists; if the error disappears, replace the sensor; if the error still exists, it's possible that the main control panel is faulted, change the main external control panel. # Special attention Most of the standard resistance values of the external temperature sensors are 15KΩ (hen temeperature is at 25℃), and the higher the temeprautre is, the lower the resistance value is, and the lower the temperature is, the higher the resistance value is. Do not use improper sensor during repairing and maintenance, or it may led to the wrong temperature sensing of the machine.
@garryarrivado5152
@garryarrivado5152 2 месяца назад
A9 error code AUX multi split
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 месяца назад
All indoor units are showing an error or only one