Тёмный
No video :(

Back On The Tools! Toughest Zappi Install EVER! 

Artisan Electrics
Подписаться 250 тыс.
Просмотров 35 тыс.
50% 1

Back On The Tools! Toughest Zappi Install EVER!
Join me as I return to working life and install an electric vehicle charging point for one of our customers.
Request a quote from Artisan Electrics here - app.openquote.net/company/art...
🔔 Join This Channel To Get Access To Perks 👇
➤ / @artisanelectrics
🧰🛠️ Tool Of The Day 👇
Bahco Pen Reamer: amzn.to/3bXEaYZ
Wiha Electricians Folding Ruler: amzn.to/38bqwAn
Knipex Cable Strippers: amzn.to/2Pzw952
Knipex Installation Pliers: amzn.to/3uTyQi0
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
-----Electricians Business Course-----
📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
➤ course.electriciansbusinessco...
🔔 Subscribe to TOOLS4SPARKS RU-vid Channel 👇
I Also Have A Dedicated RU-vid Channel About Tools:
➤ / tools4sparks
-----TESLA REFERRAL CODE-----
🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
➤ ts.la/andrew24855
-----MY ENERGY PROVIDER-----
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB/?tag=a...
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, i've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
ADVERTS THAT SUPPORT THE CHANNEL:
Thanks for your support!
This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
#evcharging #electricianlife #artisanelectrics

Опубликовано:

 

3 мар 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 249   
@artisanelectrics
@artisanelectrics Год назад
Request a quote from Artisan Electrics here - app.openquote.net/company/artisanelectrics
@neilsmith5166
@neilsmith5166 3 года назад
Standing by for Nick Bundy to mock Jordan’s intro from inside the boot! Let’s see what Mr Bundy can come up with 😂😂👍🏼
@NBundyElectrical
@NBundyElectrical 3 года назад
🤫
@Cablesmith
@Cablesmith 3 года назад
The angle drilling master back in his natural habitat 👌🏼
@artisanelectrics
@artisanelectrics 3 года назад
😎
@vScottYx
@vScottYx 3 года назад
@@artisanelectrics what snickers trousers are they? Do you have the product number please? Cheers.
@artisanelectrics
@artisanelectrics 3 года назад
Snickers 6251 amzn.to/3qkfwHg
@vScottYx
@vScottYx 3 года назад
@@artisanelectrics cheers mate
@Ted_E_Bear
@Ted_E_Bear 3 года назад
I love the channel !! Great information and comical relief at the same time makes the video very entertaining! Keep up the great work !
@artisanelectrics
@artisanelectrics 3 года назад
Thanks Ted
@MyBasketball2012
@MyBasketball2012 3 года назад
A perfect, textbook installation by Jordan. Well done!!
@artisanelectrics
@artisanelectrics 3 года назад
Thanks!
@chrishewlet5471
@chrishewlet5471 3 года назад
Love seeing these clean installs all the way across the pond from The Netherlands.
@artisanelectrics
@artisanelectrics 3 года назад
Thanks!
@mrm.k7655
@mrm.k7655 3 года назад
I just passed my level 3 ev charging by whaching yours and john Wards videos like this. A huge thanks to you guys. Learned a lot from this contents. Time to find someone now to train me properly to start over.😅
@cbcdesign001
@cbcdesign001 3 года назад
lol! Becoming very creative with your cinematography, I like it!
@artisanelectrics
@artisanelectrics 3 года назад
Thanks! 😃
@jontownsend8090
@jontownsend8090 3 года назад
Another quality production, thanks for sharing.
@artisanelectrics
@artisanelectrics 3 года назад
Thanks!
@alansayers9637
@alansayers9637 3 года назад
Another great video and well explained, have to say that having a camera person on the job makes qality viewing, top draw !!!!
@artisanelectrics
@artisanelectrics 3 года назад
Thanks yeah he's amazing its really levelling up our video quality
@jeremyreynolds3574
@jeremyreynolds3574 3 года назад
A very neat and tidy installation, as usual.
@dc-sd3gd
@dc-sd3gd 3 года назад
Such a humble coffee break😂😂😂
@artisanelectrics
@artisanelectrics 3 года назад
🤣
@johnfenlon458
@johnfenlon458 3 года назад
LOL! Good one Jordan hides the trunk... Very funny.. You did AWESOME measure and made a drill hole. Whew! Great work! Thumb up.. Cheer...
@artisanelectrics
@artisanelectrics 3 года назад
Thanks! 😁
@davidtimperley4241
@davidtimperley4241 3 года назад
Jordan - What a boss getting out there and showing your guys you can take on those really tough jobs. Nice video as ever.
@artisanelectrics
@artisanelectrics 3 года назад
HAHA yeah I try and set the lead! Down in the trenches with the lads
@davidtimperley4241
@davidtimperley4241 3 года назад
Great - keep on leading from the front
@krbuilders4685
@krbuilders4685 3 года назад
The intro in the boot had me 🤣🤣👍
@artisanelectrics
@artisanelectrics 3 года назад
LOL thanks
@krbuilders4685
@krbuilders4685 3 года назад
@@artisanelectrics but loved the install though well done Jordan
@leonblittle226
@leonblittle226 3 года назад
How can you tell if someone, especially a stranger owns a Tesla...... They tell you time and time again.
@15markav15
@15markav15 3 года назад
Just like bmw drivers.
@artisanelectrics
@artisanelectrics 3 года назад
LOL
@supersparks9466
@supersparks9466 3 года назад
I don’t think id wanna tell anyone I own a Tesla. Give me a v8 any day
@artisanelectrics
@artisanelectrics 3 года назад
Tools of the day: Bahco Pen Reamer: amzn.to/3bXEaYZ Wiha Electricians Folding Ruler: amzn.to/38bqwAn Knipex Cable Strippers: amzn.to/2Pzw952 Knipex Installation Pliers: amzn.to/3uTyQi0
@Cjrelectrical
@Cjrelectrical 3 года назад
Just about kept a straight face Jordan 🤣
@artisanelectrics
@artisanelectrics 3 года назад
LOL thanks chris
@lonewolfgeoff
@lonewolfgeoff 3 года назад
😂😂😂 oh god! jordans caught cory humour! 😂😂😂 (hey dont get me wrong! corys humour should be sold for a profit everywhere! 😂😂😂) hmm nice sleeping compartment at the start! 😂😂😂 very nice installation, something tells me your totally missing getting messed up doing ace work and enjoying it!
@artisanelectrics
@artisanelectrics 3 года назад
Haha thanks
@Holdeenio
@Holdeenio 2 года назад
For those who aren’t in the industry, like me 😄 can you explain when live became line and the reasoning given? 🤔
@daveo8480
@daveo8480 3 года назад
Hi mate just a quick one on testing . Is it ok when you guys test to somehow flash up on the screen the test result value ? As an improver I find your stuff fantastic . Thanks guys
@artisanelectrics
@artisanelectrics 3 года назад
We will try
@karlhoyle321
@karlhoyle321 3 года назад
Do you have details/a link for the screwdriver adapter/extension/bit driver thingy you use? I can never seem to find anything that long and rigid (ooh err missus)!
@cumberland1234
@cumberland1234 3 года назад
Nice to see you back on the tools Jordan. One thing if you don’t mind me asking - can an EV charger be fitted to a supply that is looped off next door, does this differ by dno’s or is it a no go? I know my supply is looped and I am end of the line. The supply cable comes from the road, down next doors drive, connects into next door, around the back of the house to mine (semi detached). To put the icing on the cake, next door have just had their drive done with tarmac. The main cable in the street runs past the front of my drive too so I don’t know why they looped it, it would have been shorter to run from the street. I suppose I could report it as high Ze, it’s 0.36 on a pme but I doubt they’ll do anything.
@fst1775
@fst1775 3 года назад
Good vid :)
@artisanelectrics
@artisanelectrics 3 года назад
Thanks!
@shaynemacdonald3051
@shaynemacdonald3051 3 года назад
Nice work
@artisanelectrics
@artisanelectrics 3 года назад
Thanks!
@jkgiygigoiuholjojouihgiygf1952
@jkgiygigoiuholjojouihgiygf1952 3 года назад
Liked and subscribed. My olev funded podpoint was installed in a new mini cu with rcd, coming from a rcd protected breaker from the main cu. Nobody has died yet, but is this within regs or just not best practice?
@artisanelectrics
@artisanelectrics 3 года назад
Thanks for joining us! Sounds ok to me but I can’t say for sure without seeing it.
@renral69
@renral69 3 года назад
4mm? In any circumstances would you install a 10mm incase the customer in future fits a fast charger? When it's such a short run especially.
@PlanetCypher_
@PlanetCypher_ 3 года назад
Jordan, I know you may have changed your point of view installing anything in the meter cupboard, but if it's owned by the householder not the DNO, what is the problem? Just an historical no no ? Thanks 👍
@ThePrawlin
@ThePrawlin 3 года назад
Correct me if I’m wrong but I think you used 4mm cable feeding the Zappi Jordan. I know it’s an ultra short run, but shouldn’t it really be 6mm for 32A? Won’t the resistive heating be a bit high? Not criticising, just learning. Peter.
@G3DOG
@G3DOG 3 года назад
Instead of a copper bus bar to stop the drill damaging the cable in the DB, I find a bolster chisel works best.
@artisanelectrics
@artisanelectrics 3 года назад
Nice tip!
@phillous1
@phillous1 3 года назад
I was lead to believe that an evse should be 2.5m away from and extreneous conductive part (as in the metal tap) or does the pen detection of the zappi cover this? Other wise neat and tidy install and waiting for a video, of an eV install from the supply in the middle of the house under the stairs
@huyongquan6554
@huyongquan6554 3 года назад
I noticed this point. The external hose near the Zappi. Amend 1 page 11 722.411.4.1 I think the external hose connected with the same earthing arrangement with the Zappi TN-C-S/ PME. So there is no earth potential. If install with TT island. That will be a issue, should be 2.5m away.
@AndyK.1
@AndyK.1 3 года назад
Someone could touch the metal down pipe at the same time
@huyongquan6554
@huyongquan6554 3 года назад
Yes. How about insulate the metal pipe or connected 4mm supplementary bonding with tap. Or seek another location for installation.
@imark7777777
@imark7777777 3 года назад
I'm not an electrician yet, I don't have an EV yet, I don't live in England ( yet maybe? ) and yet these videos never get old for some reason.
@artisanelectrics
@artisanelectrics 3 года назад
Haha thanks for watching!
@AndyK.1
@AndyK.1 3 года назад
Your camera man will be able to join your install team soon 😂
@NathanOlooney
@NathanOlooney 3 года назад
I’m learning lots but I’ll leave that to the professionals 😆
@yorkshireoz3583
@yorkshireoz3583 3 года назад
Great to see the passion you show in doing a quality job Jordan. Interesting you didn't crimp the supply cable at the Zappi, which you used to preach before (neither did Cory on his last EV install)) surely not a cost cutting measure by Artisan?? lol Love the vlogs
@ThePrawlin
@ThePrawlin 3 года назад
I believe crimped ferrules are only required when it’s a multi stranded conductor. Solid single conductors are fine as is AFAIK. Folding it over is good practice to increase the screw clamp contact area.
@artisanelectrics
@artisanelectrics 3 года назад
Yeah that’s right ferrules are only needed on fine stranded cables
@richardwillans9871
@richardwillans9871 3 года назад
Great work. What type of cable did you use?
@artisanelectrics
@artisanelectrics 3 года назад
Tuff Sheath
@mtickner
@mtickner 3 года назад
What would you suggest for two charging points/two EV's in one house? I see you can get two grants per household, so I guess it has to be two single points?
@artisanelectrics
@artisanelectrics 3 года назад
Yeah two Zappi's would be perfect as they can dynamically load balance off each other
@mtickner
@mtickner 3 года назад
@@artisanelectrics Great, thanks for letting me know. Just a shame I'm some distance from you down in Surrey.
@dtm789
@dtm789 3 года назад
Do you install a harvi ? I thought you had to install a smart charger to be eligible for the grant ?
@artisanelectrics
@artisanelectrics 3 года назад
Yes we install a harvi and hub
@mikeselectricstuff
@mikeselectricstuff 3 года назад
SHouldn't you use a 40A breaker to avoid long-term heating issues with a 32?
@artisanelectrics
@artisanelectrics 3 года назад
Manufacturers instructions recommend a 32A breaker so that’s what we fit
@buaan
@buaan 3 года назад
I thought that, my sparky put a 32amp in for the Zappi, I've set the Zappi not to charge over 30amps as I'm not a electrician but running the charger near the breaker limit seems sketchy?
@buaan
@buaan 3 года назад
Found this on Zappi install manual "This device must be equipped with an over-current protection device of maximum 32 Amps (B32)"
@cocoino2307
@cocoino2307 3 года назад
@@buaan no thats fine , the breaker is to prevent the charger from running more than 32A on the supply to protect the cable from melting , your zappi will only use how much you set it
@TheChipmunk2008
@TheChipmunk2008 3 года назад
yeah, I would if manuf's didn't recommend otherwise
@skullelliott
@skullelliott 3 года назад
Just had a zappi installed and it failed next day on pe fault 25. Found earth rod connection rusted off, so re made. Supply is not combined neutral earth. It is still going out on pe fault at end of charge, but will now reset. Car is mg zs. Any ideas?
@artisanelectrics
@artisanelectrics 3 года назад
I would connect it to the PME earth, im guessing you had an old charger and replaced it with a Zappi? Earth rod is not needed with a Zappi unless youre on a TT system for the whole house.
@NikolaiBeier
@NikolaiBeier 3 года назад
Let an electrician measure the impedance of that earth rod (an electrode) to the 'general mass of earth' or the 'loop impedance' to see if it generally has a high resistance that is barely good enough. Maybe parts of the rod further down into the soil is also corroded and making a poor contact to the soil around it. Then a new rod, or electrodes embedded in conductive concrete should help decrease/improve the contact resistance to the soil. Some say 'conductive concrete' works well, and reduces corrosion of metal parts embedded into the concrete. Manufacturers talk about 60 years of life expectancy.
@skullelliott
@skullelliott 3 года назад
@@NikolaiBeier . The earth loop impedance was good when fitted. Should be better now rod is reconnected. I researched and found earth settings in advanced setup. It was set on TT and I have now set it to TI, which is less sensitive. It is now not tripping and working fine. Does my fix sound OK?
@ravenx447
@ravenx447 3 года назад
Hi Jordan Good to see you back in the real world ! again What’s happened to your Metrel tester then? Not getting on with it??
@artisanelectrics
@artisanelectrics 3 года назад
Cory has it!
@richardnewton1800
@richardnewton1800 3 года назад
Great video, is the cable h07?
@artisanelectrics
@artisanelectrics 3 года назад
No its NYYJ
@JoannaHammond
@JoannaHammond 3 года назад
As so many new builds these days are actually flats with insufficient parking what do you think the solution is to charging when Petrol cars get banned?
@artisanelectrics
@artisanelectrics 3 года назад
More public charging points
@Blackf1ngers
@Blackf1ngers 3 года назад
I see the consumer unit has been given the usual new build level of care on installation!
@dc-sd3gd
@dc-sd3gd 3 года назад
The old chuck it in amd run
@artisanelectrics
@artisanelectrics 3 года назад
🤣
@chrishewlet5471
@chrishewlet5471 3 года назад
Does it look that bad?
@Blackf1ngers
@Blackf1ngers 3 года назад
@@chrishewlet5471 it's not great is it? I would give it 4/10 at best for workmanship. It's not awful and understand the race to the bottom is a hotly contested one on new build sites but it doesn't take a lot of effort to make it a lot better than that. I presume it's safe and compliant but it makes it more difficult to add new circuits and harder to test/inspect. When you think of the price of a nice new build house and consider the electrical installation is probably only worth £1000 you start to wonder where the money goes.
@chrishewlet5471
@chrishewlet5471 3 года назад
@@Blackf1ngers I guess it could do with some tidying up but I do like me a bit of slack. True, it's less about being the best at what you do than it is about making money fast these days for many professional installers out there.
@nathanhedgeley8016
@nathanhedgeley8016 3 года назад
Imagine being the customer and you look at the window and you see a guy with a massive camera and your electrician climbing out the back of the boot of his car.. Surely they must wonder wtf is going on sometimes 😂
@artisanelectrics
@artisanelectrics 3 года назад
Customer was a RU-vid subscriber so he offered to let us film!
@nathanhedgeley8016
@nathanhedgeley8016 3 года назад
@@artisanelectrics Haha that makes it a bit better then 😉 Nice vid as per mate 👍
@robputt
@robputt 3 года назад
Christ, your Tesla needs a clean, imagine how the aerodynamic impact of all that dirt is affecting your range :-P
@artisanelectrics
@artisanelectrics 3 года назад
Yeah unfortunately all the car washes are closed... I need to get a pressure washer!
@gino2465
@gino2465 3 года назад
Jordan did you use swa in this short run or just rubber cable.
@artisanelectrics
@artisanelectrics 3 года назад
We used Tuff Sheath cable from Doncaster Cables NYYJ 👍
@supersparks9466
@supersparks9466 3 года назад
Nagy type camera man, things are looking up.
@9plusinstalaciones
@9plusinstalaciones 3 года назад
That inside Gland is cool :-)
@artisanelectrics
@artisanelectrics 3 года назад
Thanks!
@9plusinstalaciones
@9plusinstalaciones 3 года назад
@@artisanelectrics far better than silicone
@artisanelectrics
@artisanelectrics 3 года назад
@@9plusinstalaciones yep!
@mihaidragoscretu7276
@mihaidragoscretu7276 3 года назад
Hi, just noticed you are using the Metrel EV tester with Fluke, will the EV tester work with Megger too?
@artisanelectrics
@artisanelectrics 3 года назад
Yeah it will work with all brands of tester
@mihaidragoscretu7276
@mihaidragoscretu7276 3 года назад
Great, thank you! And also will you make a quick video with the new Metrel tester that you guys have ! That would be great!
@jackflavell3908
@jackflavell3908 3 года назад
What cable was used h07 or hi tuff
@artisanelectrics
@artisanelectrics 3 года назад
Tuff Sheath NYYJ
@zjzozn
@zjzozn 3 года назад
Dave in the boot! ;-)
@artisanelectrics
@artisanelectrics 3 года назад
LOL
@darrencox150
@darrencox150 3 года назад
Can I ask a question? We've just had an Ohme charger installed. Should I have received any paperwork/certification from the installer? Thanks.
@artisanelectrics
@artisanelectrics 3 года назад
Yes you should have electrical and building regulations certificates as well as instruction manual of the charge point, they should also have submitted a DNO notification which they may choose to give you a copy of although they aren't obliged.
@darrencox150
@darrencox150 3 года назад
Thank you. Very helpful. Love the videos.
@PaulGrosvenor1
@PaulGrosvenor1 3 года назад
Would be interested to see about how to shuffled the breakers around to get the non RCD protected way.
@artisanelectrics
@artisanelectrics 3 года назад
Just shift everything to the left then add a bit of busbar
@aytonbob
@aytonbob 3 года назад
That deburring you can get double sided tools, so you can do both sides at the same time.
@artisanelectrics
@artisanelectrics 3 года назад
Cool thanks
@RobboSystems
@RobboSystems 3 года назад
is there a reason you mega before you r1 r2?
@lewis94uk
@lewis94uk 3 года назад
If the cables fucked no point carrying on with the test
@UserName-yk7om
@UserName-yk7om 3 года назад
Hi Jordan, don't be too afraid that people won't subscribe to your channel, they will, since you produce great videos! So don't push them too hard by showing of the statistics about subscribers ;) We like you, your humor and your great content! So...subscribers will come, don't worry ;) Have a nice weekend!
@artisanelectrics
@artisanelectrics 3 года назад
Haha thanks it’s just that statistically if you mention subscribing you do get way more people who subscribe because otherwise people forget! Hence why pretty much every RU-vidr asks you to like and subscribe 👍😂
@ru8y1987
@ru8y1987 3 года назад
What Snickers trousers do you get? Floorlayers?
@artisanelectrics
@artisanelectrics 3 года назад
6241
@ru8y1987
@ru8y1987 3 года назад
Cheers pal 👍🏻 say hello to Cory for me 👋🏻
@stuartjohnston1086
@stuartjohnston1086 3 года назад
Nice neat job. Shame about the hub PSU cable at 23.30 though. It's just hanging untidily to the left of the consumer unit.
@artisanelectrics
@artisanelectrics 3 года назад
Yeah its not the final location, that was just to set it up as they have no internet there yet.
@Gr33nMamba
@Gr33nMamba 3 года назад
I could give you a tougher install, mid-terraced house (with drive), with the Consumer Unit and informingly supply under the stairs, in the middle of the property.
@artisanelectrics
@artisanelectrics 3 года назад
Yeah that IS tough!
@huyongquan6554
@huyongquan6554 3 года назад
I would avoid to do the job. I can not imagine how hard it would be
@mannysandhu2215
@mannysandhu2215 3 года назад
Are EV chargers not ment to be tested to trip at 6ma smooth?? Your Fluke like my megger only do 10ma. (Im looking to get my 1741 upgrade to 1741+ for that sole reason). Apologies if its a dumb question
@AdamNoble1988
@AdamNoble1988 3 года назад
Never realised the Zappi plays a FFVII tune (victory fanfare?) on startup 😹
@artisanelectrics
@artisanelectrics 3 года назад
Yeah so cool
@isaaccknight
@isaaccknight 3 года назад
Do you mainly do ev installs I’m in Australia and have never come across one
@artisanelectrics
@artisanelectrics 3 года назад
We do all types of electrical work but we have a large growth in EV Charge Point installs at the moment as the transition to electric vehicles is happening fast here in the UK
@alanjrobertson
@alanjrobertson 3 года назад
Haha Cory would be proud of that introduction there, Jordan 😂😂
@artisanelectrics
@artisanelectrics 3 года назад
Thanks i've learnt a thing or two from his humorous slant to the videos!
@RichardArblaster
@RichardArblaster 3 года назад
7:39 Mr Angles strikes again 😎
@artisanelectrics
@artisanelectrics 3 года назад
😁
@darrencoyle3290
@darrencoyle3290 3 года назад
I would be worried about the water tap being so close to the charger... Is there any regulations about fitting so close??
@ProGamingKieran
@ProGamingKieran 3 года назад
I don't think anything would be wrong as the ev charger are waterproof
@gap9992
@gap9992 3 года назад
Nice video Jordan, did I hear you say you used 4mm cable (NYY-J)? For those watching this thinking about having an EV Charger fitted, don't use BP Pulse. I have to because a free installation was included with the car. 5 months into the process and still not fitted. OK, I have not been making a fuss because the car is only just about to arrive. They have asked for the same information multiple times, plus photos, I don't mind sending it but they ask for different things and then ignore what I have already sent! They never answer the phone! The latest mail asked if I have a spare location on the NON-RCD side of the board (again) and then they say I have to have an Isolator after the meter in the meter cupboard! Why could they not have told me that before! I now have to try to get the supply company out to do that - which will no doubt cost three times what it should and take ages! So is it true that you sparks can't add a new MCB in a CU unless the tails are dead? What's wrong with isolating the main switch in the CU??
@jonathanireland2913
@jonathanireland2913 3 года назад
Most likely a company health and safety policy to require the CU be completely dead inside. Personally after working in live industrial control panels I don't see any issues having live tails into a CU, but that's me...
@gmeadowcroft84
@gmeadowcroft84 3 года назад
good to see the Jordan is still beating Nick in the spark RU-vid battle
@artisanelectrics
@artisanelectrics 3 года назад
Haha thanks
@tvmvishnu
@tvmvishnu 3 года назад
👍
@andypaddon690
@andypaddon690 3 года назад
Measuring stick - please put a link for this - really want one but struggling to get the right type - which you have! Thanks :-)
@artisanelectrics
@artisanelectrics 3 года назад
Tools of the day: Bahco Pen Reamer: amzn.to/3bXEaYZ Wiha Electricians Folding Ruler: amzn.to/38bqwAn Knipex Cable Strippers: amzn.to/2Pzw952 Knipex Installation Pliers: amzn.to/3uTyQi0
@spammyjenkins87
@spammyjenkins87 3 года назад
"ev charging and trigonometry specialists"
@artisanelectrics
@artisanelectrics 3 года назад
Haha thats a great streamline
@python8018
@python8018 3 года назад
300ms x1 isn’t it Jordan?
@jasonbennett3076
@jasonbennett3076 3 года назад
I never realised you had a Tesla!!!🤭🤭🤭
@artisanelectrics
@artisanelectrics 3 года назад
Gotta really be able to understand my customers!
@John-pw7et
@John-pw7et 3 года назад
good job tesla can drive it’s self I think your supposed to sit in the driver seat not the boot
@artisanelectrics
@artisanelectrics 3 года назад
OOPS
@johnoreilly7052
@johnoreilly7052 3 года назад
Jordan that was a very close call when you were drilling
@artisanelectrics
@artisanelectrics 3 года назад
Thanks
@johnoreilly7052
@johnoreilly7052 3 года назад
@@artisanelectrics no problem jondon
@scotspie501douglas7
@scotspie501douglas7 3 года назад
love it was that luck
@philipshanahan4228
@philipshanahan4228 3 года назад
I see Cory's comedic attributes are starting to rub off on you. 😂😂
@artisanelectrics
@artisanelectrics 3 года назад
I’m trying 🤣
@harvdub9904
@harvdub9904 3 года назад
That's easy install
@artisanelectrics
@artisanelectrics 3 года назад
Yep!
@stephenchallis5822
@stephenchallis5822 3 года назад
Why not centre it between the door and down pipe? Too close to the tap?
@artisanelectrics
@artisanelectrics 3 года назад
Yeah it would catch on the tap when you unwind it
@pauledwards9493
@pauledwards9493 3 года назад
Don't worry, I'm sure Elon will give you a cybertruck.
@artisanelectrics
@artisanelectrics 3 года назад
I've already got one on order!
@neilwright4515
@neilwright4515 3 года назад
Didn’t know Elton John had shares in Tesla
@edc1569
@edc1569 3 года назад
Ideal for British b-roads
@pauledwards9493
@pauledwards9493 3 года назад
@@neilwright4515 good catch.
@pauledwards9493
@pauledwards9493 3 года назад
@@artisanelectrics Van thieves will be a thing of the past with that security.
@nick_yeah
@nick_yeah 3 года назад
Good to know anyone with a key for the outside box or a pair or pliers can turn off their electric...
@artisanelectrics
@artisanelectrics 3 года назад
True...
@kevy427
@kevy427 3 года назад
Yup, like millions of other houses across the Country. You often see scallywags with meter cupboard keys turning off peoples’ electric and gas🤦‍♂️
@neilwright4515
@neilwright4515 3 года назад
90% of uk houses?
@IanFarquharson2
@IanFarquharson2 3 года назад
To be fair, I did it once when my terraced neighbour left his 5am alarm for an airport run on and went away for a week. Handy way to reboot a clock.
@jordanscott96
@jordanscott96 3 года назад
definitely that kid at college who thought he knew it all
@troydavies7311
@troydavies7311 3 года назад
Im in the wrong job. Driving a Tesla to work.. wonder what Artisan earns 🤔🤔🤪
@Marclee78
@Marclee78 3 года назад
Zappi or Pod-Point??? What do you reckon?
@artisanelectrics
@artisanelectrics 3 года назад
Zappi definitely! No question
@BC-qt6fv
@BC-qt6fv 3 года назад
Installed pod points in the past under par to say the least
@Marclee78
@Marclee78 3 года назад
Thanks 👍🏻
@Marclee78
@Marclee78 3 года назад
From what I can see they are a lot easier to order with installation, and they are a bit cheaper. That’s probably why they are popular??
@bradleymay4770
@bradleymay4770 3 года назад
Is Pod point, pen fault detected??
@TheChipmunk2008
@TheChipmunk2008 3 года назад
ahem. 917 rounds to 0.92kA ;) [/first year arithmetic teacher] and you cost me 18 quid on amazon LOL
@artisanelectrics
@artisanelectrics 3 года назад
Thanks! LOL
@martinwright5113
@martinwright5113 3 года назад
Patter is howling man. Leave the comedy to the young team
@artisanelectrics
@artisanelectrics 3 года назад
Thanks mate
@martinwright5113
@martinwright5113 3 года назад
@@artisanelectrics I’m just jealous Jordan, crack on mate
@LoudAsFuckk
@LoudAsFuckk 3 года назад
That vehicle is sorely needing a wash
@artisanelectrics
@artisanelectrics 3 года назад
I know 🤦‍♂️
@anenglishmaninbrazil3212
@anenglishmaninbrazil3212 3 года назад
Nowt to do with Pye its good old fashioned hit or miss lol
@artisanelectrics
@artisanelectrics 3 года назад
Thats one way of looking at it LOL
@mikeclewlow6510
@mikeclewlow6510 3 года назад
Think Scotty kilmer has already beaten you to the boot welcoming.
@robertburrows6612
@robertburrows6612 3 года назад
I'm glad I'm not the only one who suffers HPS (Harry Potter Syndrome) spending most of the day stuck in a cupboard with no room to manoeuver
@artisanelectrics
@artisanelectrics 3 года назад
🤣
@frasercullen4525
@frasercullen4525 3 года назад
You cant install it that close to the tap??????
@jonl536
@jonl536 3 года назад
Preferred the videos without the cameraman personally. Feels abit more forced this way.
@acelectricalsecurity
@acelectricalsecurity 3 года назад
It seems what Mr Nagy does, the trend is to copy, although some do take the piss first then copy him.
@mrsandman1416
@mrsandman1416 3 года назад
Why do they not install these at eye level so you can see the screen without bending over
@edc1569
@edc1569 3 года назад
why would you look at the screen?
@seandunne2673
@seandunne2673 3 года назад
There’s regulations which state two figures (which I can’t remember right now) that the display has to be mounted on the wall. It’s so disabled people are able to reach it I think they said in one of their previous videos.
@AndyK.1
@AndyK.1 3 года назад
@@seandunne2673 it’s the height of Corys nipple I think 🤣
@mrsandman1416
@mrsandman1416 3 года назад
@@seandunne2673 all for access but that argument doesn't make sense. If we have to mount the Ev charger at that height for people in a wheel chair then surely everything else in the house such as doors, counter tops, switches etc need to follow suit.
@AndyK.1
@AndyK.1 3 года назад
Metal down pipe these days. How flash
@AndyK.1
@AndyK.1 3 года назад
Jordan doing comedy. Oh dear. Cringe
@artisanelectrics
@artisanelectrics 3 года назад
LOL
@arniewheeler4673
@arniewheeler4673 3 года назад
fell out with wife? lol... getting out the boot
@danielelise7348
@danielelise7348 3 года назад
Ok next video has to be a NON electric car charger install,because they're pretty predictable😴😴😂😂
@artisanelectrics
@artisanelectrics 3 года назад
True...
@danielelise7348
@danielelise7348 3 года назад
Next job must be a big ass 3phase factory,with all hands on tools ok?😂😂⚡⚡⚡
@AndyK.1
@AndyK.1 3 года назад
Jordan’s not use to a camera man.
@artisanelectrics
@artisanelectrics 3 года назад
No i'm rather new to it
@hallga2
@hallga2 3 года назад
45500 Fremont Blvd Fremont, CA 94538, Ha, Ha
@martingreen2633
@martingreen2633 3 года назад
Small point... It's not a reamer It's de burrer...
@artisanelectrics
@artisanelectrics 3 года назад
Thnks
@SquirreliciousMe
@SquirreliciousMe 3 года назад
Translation: Jordan wanted to show off about having a Tesla somewhat unnecessarily.
@artisanelectrics
@artisanelectrics 3 года назад
I literally don’t have a van right now as Cory nicked it! 🤣
@ChrisCordwell
@ChrisCordwell 3 года назад
Don't be a jealous badger! Jordan has worked hard for it so enjoy it!
@SquirreliciousMe
@SquirreliciousMe 3 года назад
@@artisanelectrics Sure, that's what you would say!
Далее
The lightweights ended Round One with a BANG 💪
00:10
Я тоже так могу
00:12
Просмотров 1,2 млн
На фейсконтроле 💂
09:41
Просмотров 994 тыс.
Helpful Invention | Smart DIY Idea | Useful Tools
12:16
Best 5 Home Batteries Compared - BRUTAL OPINION! 🫢
1:01:05
Do you know how an electrical cable is manufactured?
10:15