Тёмный

Backstay Sensitivity Analyses | Tall Buildings | ilustraca | Sandip Deb 

ilustraca
Подписаться 14 тыс.
Просмотров 2,5 тыс.
50% 1

Backstay Sensitivity Analyses | Tall Buildings
𝐃𝐨𝐰𝐧𝐥𝐨𝐚𝐝 𝐨𝐮𝐫 𝐧𝐞𝐰 𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐀𝐩𝐩 𝐧𝐨𝐰 !
𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐀𝐩𝐩 𝐥𝐢𝐧𝐤👇🏻
amitco.courses.store/download...
𝗜𝗹𝘂𝘀𝘁𝗿𝗮𝗰𝗮 𝗔𝗰𝗮𝗱𝗲𝗺𝘆 is now available for IOS users also !!
Follow the 2 simple steps-
1. Download 𝗠𝘆𝗜𝗻𝘀𝘁𝗶𝘁𝘂𝘁𝗲 App from App Store.
App link- lnkd.in/dxS74bQk
Join this channel to get access to perks:
/ @ilustraca

Опубликовано:

 

4 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 19   
@hirendesai5634
@hirendesai5634 2 месяца назад
Very informative and detailed explanation on behavioural aspects. I must congratulate for taking such noble initiative.
@shareqinamdar8903
@shareqinamdar8903 2 месяца назад
Very very informative video. Explanation is very clear
@seransathish7467
@seransathish7467 2 месяца назад
greetings sir this video gives me more clarify on designing the structural elements for foundation design do we have to consider critical case among the 3 conditions?
@ParthPandya-bv2by
@ParthPandya-bv2by Месяц назад
How to design backstay slab?
@BhavinKumar-gt4yi
@BhavinKumar-gt4yi 2 месяца назад
Make one video on insertion point for column and beam
@gopinath.l6963
@gopinath.l6963 2 месяца назад
Sir... Lower and upper bound modifiers to be applied for peripheral wall and podium slab in video.. Even podium level column also need to be apply or not... If no.. Y no need to apply for column sir?
@rushabhdholu2836
@rushabhdholu2836 2 месяца назад
Sir please make One video on Backstay Level Slab Analysis and Design
@aasutoshgupta4480
@aasutoshgupta4480 2 месяца назад
Sir Upload Multiple Tower Connected With the Same Podium Part 3 and there you please do sensitive Analysis
@gopinath.l6963
@gopinath.l6963 2 месяца назад
According to my understanding... With backstay effect, Tower shear walls at basement Should be idle as podium and it's associations doing resisting work... But in video... Am observing even tower shear walls at basement levels also subjecting high Shear force.. Please correct me if am wrong sir to proceed further on this
@mominshadabanjum2916
@mominshadabanjum2916 29 дней назад
In all three cases modifiers of tower elements will be as per upper and lower bound or will it be the same as given in table 5???
@mominshadabanjum2916
@mominshadabanjum2916 28 дней назад
Can you please elaborate
@divitpatel3757
@divitpatel3757 Месяц назад
have you considered any releases at backstay floor level? coz as per an article online, the tower with podium react as a cantilever and so hinge is produced at main backstay level.
@divitpatel3757
@divitpatel3757 Месяц назад
I've taken backstay as my thesis topic, and have given releases to beams at main backstay level. Is it correct way to model ??
@ilustraca
@ilustraca Месяц назад
Hinge formation and moment release are not the same thing… Hinge formation happens when the structure shows inelastic deformation… That can be asseses by non-linear analysis… That is not shown here.
@michaelloreantz
@michaelloreantz 2 месяца назад
Supposed you are designing the structure complying to ASCE 7, where dynamic base shear has to be scaled to match static base shear. Which dynamic base shear do you take in this backstay case? Do you take it at the podium level or at the base level?
@ilustraca
@ilustraca 2 месяца назад
The basement shall be designed for static case only considering higher spectral as that part is more stiffer, dynamic base shear of tower shall be scaled separately assuming top of basement as support.
@michaelloreantz
@michaelloreantz 2 месяца назад
@@ilustraca so two step analysis then, where you design the tower using response spectrum analysis and the basement using static procedure?
@abhishekjaiswal2691
@abhishekjaiswal2691 2 месяца назад
Did you model the slabs as a rigid diaphragm?
@ilustraca
@ilustraca 2 месяца назад
no…
Далее