Bad HVAC TXV Overview! And a Tip Not Even the Pros Know! 

HVAC Guide for Homeowners
Подписаться 145 тыс.
Просмотров 3 тыс.
50% 1

In this video, Josh goes over what is a TXV? Across America, thousands of homeowners are told they need to replace their TXV on their HVAC system. What exactly is a TXV? Joshua explains what it is, what you should do if a pro tells you it has failed, why it costs so much to replace, and even shares a few tips that not even the pros know. Have a pro tell you that your TXV has failed? Watch this video, before having the TXV replaced!
For more information on Griffin Air, visit www.griffinair...
For more information on New HVAC Guide, visit www.newhvacgui...
*Need Financing for your HVAC? Visit www.newhvacgui...
*Own a Service Biz and want to grow? Visit www.newhvacgui...
*Our favorite products?
Favorite Thermostat click here: amzn.to/3wt3Vwh
Favorite Air Cleaner here: amzn.to/4bGkqGB
Favorite Air Filter here: amzn.to/3vpVbWl
Air Tester/Monitor here: amzn.to/3oJ3LvD
Dehumidifier here: amzn.to/3Q4woPp
Humidifier here: amzn.to/3ilZ9vq
Smart Vent here: amzn.to/3JDfGDX
HVAC Soft Start: amzn.to/3kMXlwT
HVAC Guide for Homeowners is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program to provide a means for sites to earn advertising fees by advertising and linking to amazon.com. Amazon offers a small commission on products sold through their affiliate links. Each of your purchases via our Amazon affiliation links supports our cause at no additional cost to you.
Griffin Air and Joshua Griffin have partnered with Daikin on multiple projects. FTC requires disclosure of these relationships due to the compensation received.
---------Chapters-----------
0:00 Intro: What is a TXV?
1:17 Failed TXV
1:40 Cost to replace
2:13 Heat Pumps
2:40 Different Valves
3:11 Solenoid coils
3:35 Misdiagnosed TXVs
4:14 Get a second opinion
4:52 The Problem
5:51 What do you do?
7:07 Outro
#txv #hvac #heatpump

Опубликовано:

 

15 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 32   
@larrymedina9737
@larrymedina9737 4 дня назад
Brother, I just checked back on your channel and saw you're over 145K subscribers man that's awesome. Congrats on that
@SleepStoryCentral
@SleepStoryCentral Месяц назад
During my yearly AC maintenance visit, I as told the TXV is bad: “ Refrigerant pressure appears well above manufacturer specifications Upon inspection of the indoor unit. Placed handover metering device sensing bulb, refrigerant pressures begin to normalize. Removed hand from sensing bulb and system goes back to appearing overcharged. System will require replacement Thermostatic Expansion Valve.” Installed this Carrier AC & furnace 4 years ago. So still under warranty. They quoted me $2300 to replace TXV. I think I need to get another “regular maintenance” done by another company and see if they say anything without me bringing up what the other company said.
@bmorekairful
@bmorekairful 17 дней назад
So your saving customer adding refrigerant b/c they are little low. That system would have a leak then. Guys generally try to add 1st b/c they don’t check SH & SC b4 they condemn TXV. Many don’t know, but very few condemn txv b4 adding refrigerant
@corruptedbrain6
@corruptedbrain6 Год назад
good video man !
@NewHVACGuide
@NewHVACGuide Год назад
Thanks pal!
@theoutspokenengineer
@theoutspokenengineer Год назад
Good video Josh!
@NewHVACGuide
@NewHVACGuide Год назад
Thanks pal!
@tekjunkie28
@tekjunkie28 Год назад
The other problem is that placement of the TXV and installation is almost always wrong. I have a Trave RTU at work that the TXV was placed on the suction line incorrectly from the factory.
@bobboscarato1313
@bobboscarato1313 Год назад
How often did that happen?
@tekjunkie28
@tekjunkie28 Год назад
@@bobboscarato1313 well from the few units I’ve seen compared to other tech it’s been every single one. The last one I seen was at my current work and the TXV is installed on the top go the suction line. Manual states it has to be installed on the bottom 1/3 of the line. So at the 5oclock position from what I gather.
@ohiopat
@ohiopat Год назад
I've seen where there is a dirty or frozen coil and they overcharged it trying to get the suction pressure up, then they try adjusting the valve to make up for it.
@NewHVACGuide
@NewHVACGuide Год назад
Same. Crazy pal
@bobboscarato1313
@bobboscarato1313 Год назад
Poor training is one reason that comes to mind.-
@virtual_bomber5698
@virtual_bomber5698 Год назад
Mannnnn, just do like all the big companies do nowadays when there is ANY kind of issue with a system: "Sir/Ma'am......you just need a new unit!"
@eastcoast186
@eastcoast186 Год назад
What’s the tip ????
@NewHVACGuide
@NewHVACGuide Год назад
TXVs are misdiagnosed because of low refrigerant, air flow issues, and incompetence by techs all the time
@dankelley9361
@dankelley9361 Год назад
2K to change out a valve? Give me a break, isn’t any repair done without ripping off the customer?
@NewHVACGuide
@NewHVACGuide Год назад
Second opinion time!
@bobboscarato1313
@bobboscarato1313 Год назад
For that price you can install a new coil with extended warranty!
@Garth2011
@Garth2011 Год назад
Seems like the licensing process for HVAC needs to include more information, training and then final testing before they issue some of these people a license to diagnose equipment issues. Time and time we see and hear of HVAC techs misdiagnosing and performing below standard quality work and use of below average quality parts. My guess is the charges are right up there with the industry average yet the labor and workmanship suffers rather large.
@NewHVACGuide
@NewHVACGuide Год назад
It’s a dilemma. Pros deciding if they should invest more in themselves while customers think they make too much.
@Garth2011
@Garth2011 Год назад
@@NewHVACGuide LOL...its all about pride in workmanship and doing the job as it should be done. Defineately not based on the boat and RV payments coming due. If work is done well, the money follows
@pefkpickell
@pefkpickell Месяц назад
Truth. Started for new commercial company. I am seeing some things are mind blowing.
@elgringoec
@elgringoec Год назад
Hey Josh. Have you seen a case where the supply plenum air temperature ramps up and down periodically? I haven't before, but here's what's happening. It oscillates between 90 and 97, takes about a minute for each change to complete, plateaus about half a minute at high and at low then proceeds to change again. Up-down-up-down repeatedly. Something I might expect if the compressor power were being cycled. Conditions: outdoor 59F, 51% humidity Indoor 66 and 46% Airflow/static normal, good, and constant. Coils clean, outdoor devoid of frost, compressor and outdoor fan running continuously and sounding smooth. R22, orifice metered both directions. Bizarre?
@elgringoec
@elgringoec Год назад
Sorry if that was too much to ask. Maybe Brian at HVAC school would know and answer.
@NewHVACGuide
@NewHVACGuide Год назад
A couple things come to mind. Since it’s an orifice, I would rule out metering device. Noncondensibles, reversing valve, compressor valves, low-voltage issue are the first things I would check. Sorry, I didn’t answer your question right away.
@elgringoec
@elgringoec Год назад
@@NewHVACGuide Thanks Josh, no prob, I know how easy it is to forget about stuff for later, that's why I pinged you. I've not seen anyone talk about this happening before so it must be either unusual or people just aren't witnessing it because it's a long term monitoring situation. So from your list, the only thing on it that hasn't already been ruled out is compressor valves. It's a Goodman that's been running for 29 years so maybe it's time. It's been heating like a champ all winter, which I'm thankful for. I've never seen this ramping happen but then again this winter is the first where I've had a permanent thermometer installed to see duct temp at a glance of the readout on the wall. It's a great way to alert me that ice is starting to form on the outdoor evaporator. And I've been watching its behavior this season so this unusual activity caught my eye but I have no way of knowing if it's ever happened in prior years under similar operating conditions when I wasn't watching the duct air temp. The indoor temp was so close to the outdoor temp, and that was because I'd turned the system off while we were away for a bit. It worked surprisingly well when we had large temp differences inside to out, like 74 inside and teens outside. I was still getting duct air temps in the upper nineties. This warm spell has caused little to no need of heat so I haven't been able to watch its behavior since that time last week when it caused me concern. I'm thinking if it gets to where we need heat enough that it runs a while and I see the temp ramping up and down again, I should throw the gauge set on and watch for pressure ramping. Not that I'd then know what's causing it but it would be another clue I think. But the way the weather is going (and no complete about that) it probably won't come on much more this year. It's 77 in the house now and it hasn't run at all for a couple days. Appreciate you getting back to me Josh. Take care and enjoy!
@NewHVACGuide
@NewHVACGuide Год назад
@@elgringoec 29 years! Wow. I see so many people bash Brands, and Goodman always seems to be one of those brands that is polarizing. 29 years really says some thing though!
@elgringoec
@elgringoec Год назад
@@NewHVACGuide It's like you said earlier, Josh - companies change, the industry changes - change is the only constant. At that time, in '94, Goodman made units for five or six "brands" plus their own. My unit was bought straight from the factory in Texas, it has no external brand markings on it. It came with six or so labels in the doc pac for the purchaser to brand with. Presumably they'd be shipped to a dealer who'd apply their affiliate brand label. I just got lucky. It was built well with decent components and the only problem so far is the reversing valve getting stuck in heat mode about ten years ago. And I blame myself for brazing up my lineset without nitrogen so I likely introduced flaking and the filter/dryers maybe didn't capture it all. I really expected I'd have to renew the system sooner. And I'd'a done so if it weren't for all the flux surrounding the refrigerant scenario. I feel like I'm stuck in an uncertain world of limbo.
@SonsofIssac
@SonsofIssac Год назад
I think there’s just a lack of experienced guys out here. When I was an apprentice it was the school of hard knocks. The guys who knew what they were doing really didn’t care to pass on on information or help a guy out with things… a few of them did but to be straight up there are a ton of a$$hol€s in this industry. If you’re starting from the ground up the first 3 or 4 years are gonna be tough
@NewHVACGuide
@NewHVACGuide Год назад
This is definitely a theme. I was lucky to find a couple gold mentors along the way, but my overall experience aligns with your assessment.
Далее
Мухочирон эхтиёт бошед!
01:31
Просмотров 117 тыс.
❌Ему повезло больше всех #story
00:41
HVAC Systems Elevated for These Reasons!
6:04
Просмотров 2,4 тыс.
R32 Flammability Test
7:16
Просмотров 11 тыс.
Troubleshooting  the TXV
19:23
Просмотров 49 тыс.
Bad TXV:   Is it always the powerhead?
27:13
Просмотров 3,6 тыс.
HVAC 105 Scenario: Overfeeding Metering device
6:59
Air Conditioning isn't free... but we're close.
25:45
How to know if the TXV is Bad?
5:43
Просмотров 81 тыс.
Bad TXV & The Reason Why They Are Going Bad
12:28
Просмотров 186 тыс.