Nice one brother... Carbonisation of the electrodes and rectification probes is very common. The state of the electrodes gives a good insight into if the burner mix is too high or too low.. Burnt or melted probes can mean too high carbon ratio or heavy coating to little. Correct set up of the gas/air ratio very important to correct operation.
Thanks for uploading! I had same exact symptoms. Allowed me to narrow down cause. I cleaned the probe but issue persisted. Ended up being the contacts on the other end of the cable needed cleaned. Contacts calcified from a prior leak.
I had E133 yesterday, it turned out to be a split condense pipe leaking onto the flame rectification plastic joint and cutting it out. It was the original grey flexible one, replaced to black hose.
Litrally have the same leaking boiler and have not had heating or hot water since 5 15 on 16th Dec.. should be fixed oin next 24 hours but exactly same issue it's leaking and putting the pilot light out
Been missing your videos mate. Hopefully your back soon. Always seems to happen. Engineers go in a different direction or just stop filming. More importantly, hope everything's good with you 🎉
I’m really sorry I don’t anymore I’m a bit too far away, Sounds to me like the gas may not be getting to the boiler or needs to be purged Please call a local gas safe engineer to repair or rectify this Thanks for watching
Guys got a eco compact 30 hot water runs fine but no heating.rads and water symbols shown but no flame when demanding heating.The red and green lights are flashing on receiver cant solve?i have turn the hot water dial 90 degrees twice it fires up with flame symbol then heats up then flame goes out do it a couple of times then i get flashing error 133 flame crossed out and an R top right above error number. i have blaming my receiver and thermostat no connecting does that narrow it down ?its getting cold. regards