New (ish) gas engineer

Wanting to share my week by week jobs and help new guys learn what I have had to learn over the last couple of years

Gear reviews

Tool kit walk throughs of what I use

New tools as I buy them and will review as I use

Baxi, Worcester Bosch, veissmann, vaillant, atag, main, megaflo, ferroli, ravenheat, navien, grundfoss, wilo, heatgeek, intergas, talon, heatrae sadia, adey, boiler repairs, boiler servicing, boiler installation, new boilers, powerflushing, magna clean, adey chemicals, faulty pump, faulty pcb’s, diverter valve, balancing, efficiently, gas engineers, plumbing, Honeywell, Drayton, 2 port valve, 3 port valve, top up pressure
A job in my day as a gas engineer
5:18
5 месяцев назад
My 7 tools I can’t live without
2:26
5 месяцев назад
Vaillant boiler service & pressure loss
6:31
5 месяцев назад
Vaillant turbo max diverter valve replacement
3:41
5 месяцев назад
Worcester greenstar flow manifold replacement
6:11
5 месяцев назад
Vaillant diverter cardtridge replacement
6:48
6 месяцев назад
A day in the life of a gas engineer
9:01
10 месяцев назад
Day in the life of a gas engineer
2:07
10 месяцев назад
A day in the life of a gas engineer
20:53
10 месяцев назад
A day in the life of a gas engineer
12:16
10 месяцев назад
Let’s bring back 90s/2000 cars!
16:58
11 месяцев назад
Your gas fault app in depth
4:48
Год назад
F22 app in more detail
4:06
Год назад
Mount snowdon summit climb
47:25
Год назад
Plumber playing mechanic
8:57
Год назад
REACTION video,plumbing FAILS
8:03
Год назад
Vaillant Ecofit F83 fault code
9:01
Год назад
Комментарии
@tedchan7537
@tedchan7537 4 дня назад
Hi, in what situation or fault of the boiler for this hydraulic assembly replacement?
@adept66
@adept66 6 дней назад
Cheers, exactly what was needed, improved the continuity with a piece of emery and it all worked as it should
@Dimpaul7
@Dimpaul7 10 дней назад
Currently got this problem on a two year old install and im absolutely stumped.
@Dimpaul7
@Dimpaul7 10 дней назад
Open vent, 3 port, new pump 🫠
@seanb-ol3up
@seanb-ol3up 11 дней назад
If the co2 doesn't adjust within range is it a faulty gas valve?
@snapgas9832
@snapgas9832 10 дней назад
Not necessarily mate, could be that the gas valve needs adjusting Or could be the heat exchanger is blocked up etc
@Putinspurpleheaded
@Putinspurpleheaded 14 дней назад
The tapper just blitz it instead of taking weeks over it
@johnadams1976
@johnadams1976 17 дней назад
I'd have refused to fix it until they put a new battery in their smoke alarm!!
@zxcherry7356
@zxcherry7356 21 день назад
Hi for brown and orange wot shud the readings be? Not very familar with s and y plan systems. Thank u
@snapgas9832
@snapgas9832 20 дней назад
Message me on TikTok under snapgas and I’ll try and help mate with a video! Hope that helps
@janegreen191
@janegreen191 24 дня назад
Engineer said by Greenstar 24i junior is overheating, said I should replace the boiler. Do you agree. The boiler is 11 years old.
@snapgas9832
@snapgas9832 24 дня назад
Yes, Aslong as he has checked all the other avenues
@janegreen191
@janegreen191 24 дня назад
@@snapgas9832 What are all the other avenues. Please list them. I had a Sime boiler before and it lasted 15 years. This Greenstar combi boiler 24i only lasted 11 years. I want a simple boiler and not the computerised ones, easy to access. What do you recommend that would last longer that 11 years.
@haiderm1384
@haiderm1384 26 дней назад
Brilliant video thank you! Just a few questions: 1. Did you add inhibitor to the system after? 2. Were the other radiators left open or closed? 3. Did you drain the system completely or near enough?
@sulemanpeer9433
@sulemanpeer9433 26 дней назад
Great of you to share
@seanmolloy7622
@seanmolloy7622 26 дней назад
I think I have a boiler with the same issue, set it going runs ok for a couple of minutes, cuts out, loads of water hammer. Leave it for 10 mins to cool down and it starts again ok. I'm thinking I take the casing off and see if it still trips out
@andrewscourfield7530
@andrewscourfield7530 Месяц назад
Great information mate thanks Andrew
@b1h2u3p4
@b1h2u3p4 Месяц назад
Has this tip worked
@mistaceali1177
@mistaceali1177 Месяц назад
I did this without a vac, bottom floor. Just to note i destroyed the area and my thumb as it cut so deep trying to stop the flow when taking the trv off, whole area was drenched with water and my blood, to date i don’t even know what made me attempt it 😭 never again!!!
@snapgas9832
@snapgas9832 Месяц назад
😂😂😂 that’s brilliant mate! We learn by our mistakes! It’s just such a rush 😂😂
@sXRaider91
@sXRaider91 Месяц назад
Very helpful. Thank you!
@snapgas9832
@snapgas9832 Месяц назад
Brilliant
@ryantidball1118
@ryantidball1118 Месяц назад
Pretty sure the pump is fine the new high efficiency pumps don’t have pump speed they modulate down with boiler
@abrarhussain5478
@abrarhussain5478 2 месяца назад
Bro good but don't draw your pic show proper boiler
@11982463
@11982463 2 месяца назад
that main combi at 6:40 E50 error code, have you been back to change DHW NTC or did you get it by cleaning out limescale on cabel whilst u were on site
@dodger445
@dodger445 2 месяца назад
I had the f83 on an open vented vaillant. F and e tank, cold feed was blocked where it tees into open vent. Bunged the tank, rather than full drain down and risk more air locks. Undone the compression tee and cleaned out with a screwdriver. Refitted, removed bungs , vented air valves in cylinder cupboard, reset boiler. Now works like a dream.
@snapgas9832
@snapgas9832 2 месяца назад
Yep that would cause F83 mate, good job getting it sorted
@sarajan9392
@sarajan9392 2 месяца назад
Video was so rubbish not good at all
@Noname4now2025
@Noname4now2025 2 месяца назад
If i press - and + together what s happend?
@snapgas9832
@snapgas9832 2 месяца назад
Nothing, This is for gas engineers, thanks
@Noname4now2025
@Noname4now2025 2 месяца назад
@@snapgas9832 thank You,i pressed by mistake and i worry i done Something wrong
@andyking5670
@andyking5670 2 месяца назад
Informative but cut the crap music.
@joshmannix8173
@joshmannix8173 3 месяца назад
Decent tip👍🏼
@dickiedubs3137
@dickiedubs3137 3 месяца назад
Those burner gaskets are crap, not fit for purpose. I've been to boilers that are no older than two years and those gaskets are leaking. It's got to the point it's now my first check.... nothing worse than changing one of those on a hot heat cell
@iqbalnuthoo1566
@iqbalnuthoo1566 3 месяца назад
Thank you, good explanation
@Pottenham
@Pottenham 3 месяца назад
Evidently I have a 'single pipe' sytem , and had a Vaillant Eco Pure installed about 18 months ago, and it's now showing F83 AND F23! Vaillant say it's the system, installer says I need to bleed all rads and try just turning the boiler off at the receiver and leave for 10 minutes, then turn on again?? Nothing's working. Would a 'power flush help?
@snapgas9832
@snapgas9832 3 месяца назад
Hi, I don’t think it will help, it’s to do with the flow and return temps back to the boiler on 2 sensors So yes vaillant are correct it’s a system issue unfortunately My advice to get by would be to get the boiler changed to a Worcester RI as they don’t have these sensors and that could work
@Pottenham
@Pottenham 3 месяца назад
@snapgas9832 thanks for your help, much appreciated.
@seanb-ol3up
@seanb-ol3up 3 месяца назад
Was at one of these today the data badge says co2 9.6%/8.6% but any manual i find or see says 9.8%/9.2% which is right?
@Murph9000
@Murph9000 3 месяца назад
The tundish looks dodgy as well. Looks like 15mm in and out, should be 22mm out per building regs and cylinder manufacturer (or 28mm if it's a long run). Also doesn't have 300mm vertical pipe below the tundish. If one of the relief valves decides to let go with a lot of flow, it will likely overflow inside the loft space. Edit: Or, if that's 22mm in and out, and a 22mm T&P valve, should be minimum 28mm out.
@reececoy9071
@reececoy9071 4 месяца назад
Best way to do it is use your grips to grip the bypass ass close to the manifold as possible big flathead inbetween grips and manifold twist and it will fly out
@snapgas9832
@snapgas9832 4 месяца назад
Nice
@Derekm-ls7jr
@Derekm-ls7jr 4 месяца назад
just got into your videos they are the jobs i get and really relate to in the real world chris. keep up the good work and look forward to the ones i aint seen yet!
@snapgas9832
@snapgas9832 4 месяца назад
Nice 1 Cheers derek
@FXHEROS
@FXHEROS 4 месяца назад
Did you get professional training or doing this yourself?
@snapgas9832
@snapgas9832 4 месяца назад
Hi mate, I learnt as I went along, but also I used to buy old boilers from people and strip them down and rebuild them at home to get to know how they went together And once you have done 1 heat exchanger then they become a lot easier after that as you learn from mistakes or that you have taken too much stuff out that you didn’t need to
@FXHEROS
@FXHEROS 4 месяца назад
@@snapgas9832 I've repaired computers and built computers not much different I would imagine it's easier as a bigger component. I'm fed up with cowboys coming out and just telling you get a new boiler half my boiler is new after 11 years of repairs so why let all those new parts go to waste plus you can pick up a spares boiler or used one for £50-100 and need £10-20 worth of tools rather than spending £2500-£4000 on a boiler which will break down yearly.
@jwebber8938
@jwebber8938 4 месяца назад
nice shout. will keep that in mind.
@lakerfan7324
@lakerfan7324 4 месяца назад
What does 100 represent?
@ging93
@ging93 5 месяцев назад
Is it safe to spray these with WD40, GT85, etc?
@TheDickPuller
@TheDickPuller 5 месяцев назад
Mate, you don’t need a new fan. Any Fan on the negative side of the Burner, you just replace the Bearings.
@CarolinefmRadio
@CarolinefmRadio 5 месяцев назад
Hi Can you advise, my boiler is the 24i junior with the same problem, where is the gasket?
@snapgas9832
@snapgas9832 5 месяцев назад
Please get a gas safe engineer to repair this, as may be a different fault!
@charliewillis8527
@charliewillis8527 5 месяцев назад
Needs a canopy built over it to finish it off
@plumbertime
@plumbertime 5 месяцев назад
It was only meant in a light hearted way mate 👍
@edmoffatt-dv6yx
@edmoffatt-dv6yx 5 месяцев назад
All thumbs and loud music. What did he say? Much easier to follow if shown in situ
@snapgas9832
@snapgas9832 5 месяцев назад
Apologies, this was 1 of my first ever videos and was extremely nervous
@craigmcgregor5463
@craigmcgregor5463 5 месяцев назад
Just been on holiday to Denmark last week and back to catching up. Scrolled down to your name to watch your videos first. Enjoy them. Keep up the good work. Missed you when you stopped. Just need people to be aware of your videos. Contents good. Part of a select few i would highly recommend. Some boys have made it youtube famous now and content is different or stopped doing videos. Thanks mate
@snapgas9832
@snapgas9832 5 месяцев назад
Nice 1, thanks for that mate! Much appreciated
@stephenharris5519
@stephenharris5519 5 месяцев назад
And don’t take the min max from the data badge. Some Greenstars have different on the badge than is in the MI’s.
@macpatel7810
@macpatel7810 5 месяцев назад
Nice one mate
@andrewscourfield7530
@andrewscourfield7530 5 месяцев назад
Which one is red seal
@snapgas9832
@snapgas9832 5 месяцев назад
The top burner seal, they need to be checked for any leak of products of combustion every time, and replaced as necessary
@andrewscourfield7530
@andrewscourfield7530 5 месяцев назад
Thanks for help
@andrewscourfield7530
@andrewscourfield7530 5 месяцев назад
Great information mate thanks easy to follow
@snapgas9832
@snapgas9832 5 месяцев назад
Glad to help
@ginola602
@ginola602 5 месяцев назад
Great Video,I wish you would have posted this sooner,but thanks anyway, any advice is welcome!
@snapgas9832
@snapgas9832 5 месяцев назад
This is actually an old video re uploaded to help out, go back through my earlier videos and you’ll see more mate like this
@stephenharris5519
@stephenharris5519 5 месяцев назад
The will to live
@snapgas9832
@snapgas9832 5 месяцев назад
😂 we all need this mate
@stephenharris5519
@stephenharris5519 5 месяцев назад
You forgot the welds on the heat exchangers failing and the non cleanable burner blocking up. Absolute garbage piece of kit.
@snapgas9832
@snapgas9832 5 месяцев назад
Sorry yeah your right, I was more thinking for servicing or just for safety aspects
@stephenharris5519
@stephenharris5519 5 месяцев назад
@@snapgas9832us service monkeys cop for it all. Starts the jet engine noise when on low fire ? Best get that probe whipped out the flue quickly cos it’s about to flood your analyser. Then the customer comes running in going “that’s the noise I was telling you about !”
@paulcairns-me3lb
@paulcairns-me3lb 5 месяцев назад
Real shortage of Vokera content on RU-vid. Particularly Linea 4709490.
@ginola602
@ginola602 5 месяцев назад
Waste of an expensive filter! That is shocking.
@ginola602
@ginola602 5 месяцев назад
How to test and change boiler components.