Butchered Fuseboard 🤦🏿‍♂️AND No Main Earth For 40 Years!!! | Fault Find and Repair 

Eastway Electrical
Подписаться 37 тыс.
Просмотров 83 тыс.
50% 1

This video is made in association with Ads + Brand. Facebook Ads Agency for small business:
Contact Ads + Brand for a consultation: www.adsandbran...
Please also follow me on Instagram:
/ delroythespark
We will soon be launching a Facebook Group for all electrical enthusiasts to interact and share information. To be notified when this launches please join the Delroy The Spark Mailing List:
eepurl.com/hdRPXD

Опубликовано:

 

28 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 222   
@edinburghambler
@edinburghambler 3 года назад
I'm not an electrician or needing electrical work and no idea how i ended up on this video but I've just watched the whole thing with great interest. Subbed lol 👍✊
@eastwayelectrical
@eastwayelectrical 3 года назад
Welcome to electrician RU-vid
@Lesboss1968
@Lesboss1968 3 года назад
I used to be a cable jointer, to fit an earth wire to the cable, the best way is to strip back both steel tape armours, clean off the bituminous impregnated paper off the lead sheath. You then tie the earth wire to the sheath and using a blow torch and D metal you plumb the earth wire to the lead sheath and the other end goes into an earth block. Another method was to change the iron clad cut out for a new plastic modern one and the earth wire then went into the earth block connector on the new cut out. We used to strip these cables live by cutting off the lead sheath and then getting to the cores that were only covered in paper tape.
@starman_uk
@starman_uk 2 месяца назад
Sadly we don't solder any more but respect for the old lost to time skills but we use a tension force spring and copper braid to provide a suitable earth on an old PILC based service
@michaelnapier292
@michaelnapier292 3 года назад
The gods were shining on you that day del. I certainly wouldn't be hacking away at a pilc cable. Should have put in a temp earth electrode. Well done on sorting the customer out.
@farooqshah2797
@farooqshah2797 3 года назад
balls of Steel !!
@Tammas
@Tammas 3 года назад
There was no danger mate - he only removed the hessian. Under that it's 2 layers of steel tape armour and you won't get through that with a knife.
@slopsallover
@slopsallover 3 года назад
Man you've got some patience....confirms why I ditched domestic sparkying a long time ago ...fair play to you for taking the job on. 👍
@garrett69
@garrett69 3 года назад
Agreed. I do purely industrial electrics these days.
@therealbosstopob4l974
@therealbosstopob4l974 2 года назад
@@garrett69 What’s the problem with domestic?
@pistolpete5189
@pistolpete5189 3 года назад
Del your braver than me I would have ran for the hills with that one 😂
@caliden
@caliden 3 года назад
I think it's because the lady seemed nice and had him back within a few days so there was no messing him about with price.
@marlonblade007
@marlonblade007 3 года назад
Even I know no earth is bad
@jamesl1143
@jamesl1143 3 года назад
Got to be doing ZS @ DB or ZE on the first visit especially if ZS at socket is to high
@johnnyfive306
@johnnyfive306 3 года назад
Beat me to it, 100% mate
@Mainly_Electrical
@Mainly_Electrical Год назад
Exactly
@mathman0101
@mathman0101 3 года назад
Crazy del your a brave man fitting that clamp to the sheath. Certainly one for the DNO. If u you out work live I would have had CAT rated arc gear on, like we do in the USA. With double insulated rates gloves, face shield and fire rated clothing. No simple jobs for you Del. Get yourself a metabo chaser well worth the investment.
@McMonkeyful
@McMonkeyful 3 года назад
I agree. Not a risk I'd take. That said, a pal of mine who works for the board did the same thing as a temporary fix for me years ago. Shaved off a bit of the lead sheath & replaced the clamp that was on there for a braided TNS connection. Thing is, he'd worked for the board for many years & was qualified to work on it. I've since paid to have the meter relocated outside & they put in a TN-C-S earth. I do not recommend anyone tries this fix, even as a temporary measure!
@Tammas
@Tammas 3 года назад
There was no danger lol, it's got 2 layers of steel tape armour and that's what he temp connected to.
@SamHughes89
@SamHughes89 3 года назад
Gotta love del talking about getting clips on a 12 inch crawl space when the job is already a nightmare without the clips! 🙈
@jooproos6559
@jooproos6559 14 дней назад
As a former elektricien in the Netherlands i am looking at this with amazement!What a mess under the floor!That would not be in the most off the houses in the Netherlands!Just a few cables here and there and under the floor and that is it really! In our houses there is already so long ago decided to use metallic pipes first and later on plastic pipes to get the wires through.Because its tidy and better for the wires.And if some idiote goes mess up with the wires they are easy to find,unless when they are disappearing in the wall. So if there is a trouble with the wiring you can relatively put the new wires on the old ones and it just a matter off puling the wires through until you see the connection with the new wire.And then its correctly again and reliable too. So if there is something above the cellar not right you know you dont really have to check under the floor.
@markfitzgerald223
@markfitzgerald223 3 года назад
Great work Del, but why didn’t you get that lady from your last job around , she would have talk you through fixing the problems in no time 🤣
@eastwayelectrical
@eastwayelectrical 3 года назад
Haha
@PhanoftheShow
@PhanoftheShow 3 года назад
legend has it she’s still talking
@ColinDH12345
@ColinDH12345 3 года назад
18:33 I started sweating and had a panic attack !!! Old TT system obviously and the earth, as you suspected, must have been an incoming water or to a stake somewhere.
@johnlishman4946
@johnlishman4946 Год назад
or probably corroded away somewhere as earth clamp's do
@danieldelaney9062
@danieldelaney9062 3 года назад
You could ring that through to the DNO(distribution) as an emergency job, they would attend on the day to fix the earthing problem
@kennethausten
@kennethausten 8 месяцев назад
Last extension i was called out to was wired in twin bell wire. Several two gang 13a sockets. Then found connected to the lighting circuit. I just powered down and advised the owner to contact the builder who installed it. No earth obviously.
@barrydoherty636
@barrydoherty636 3 года назад
Well done Del, you've got a nice way about you.
@joanofarc708
@joanofarc708 Год назад
God bless your patience mate you litrally don't know what you're walking into
@SPARKY400T
@SPARKY400T 3 года назад
Brave man fitting a bonding clamp onto PILC! could you get the DNO to PME it ?
@stuartandrews4344
@stuartandrews4344 3 года назад
@@fromthetoon1602 Same here,DNO would have also upgraded cutout.
@bradleyjames3709
@bradleyjames3709 3 года назад
I think Delroy said it was all temporary.
@bradleyjames3709
@bradleyjames3709 3 года назад
Oh maybe. At least Ze must be down to a reasonable value now so it’s much safer than it was.
@r3co0
@r3co0 3 года назад
@Dusty 99 you aren't allowed to touch the pilc coming into the property as a normal spark, dodge city. Phone the dno and they will put an earth sweat for the customer for free.
@Mainly_Electrical
@Mainly_Electrical Год назад
It's a DNO issue
@rrenvrrenv8014
@rrenvrrenv8014 3 года назад
If there is rcd protection then a loop reading of 36 ohm's is not a reason to disconnect the power
@Mainly_Electrical
@Mainly_Electrical Год назад
It's unsafe with an inadequate means of earthing
@mattWallJsy
@mattWallJsy 3 года назад
Always amazing what you find! At least it's safer now!
@eastwayelectrical
@eastwayelectrical 3 года назад
Yep, there's always something new to find
@mattWallJsy
@mattWallJsy 3 года назад
@@eastwayelectrical You should see the delights im working on right now! 😳🤯🤣🤣🤣
@roostah
@roostah 3 года назад
Not a spark but enjoy the vids so apologies if this is a daft question...If the earth was non existent originally, was the remedial work on all the sockets truly necessary? Sort the earthing, kitchen and living room in turn sorted? I may be missing something not explained but that's how I took the video after all that.
@McMonkeyful
@McMonkeyful 3 года назад
I'm not a spark either but I think the tripping was due to the faulty wiring and the fact there wasn't a reliable earth was just another problem on top of that, not the cause of the tripping. I could be wrong.
@adamsharp201
@adamsharp201 Год назад
Both comments are accurate but mean nothing if you aren't a fully qualified electrician. Stick to your day job.
@roostah
@roostah Год назад
@@adamsharp201 What's yours? Trolling on YT? Nothing wrong with asking questions
@jonathanowens7252
@jonathanowens7252 3 года назад
Not a spark, but I'd have thought you'd have had to call the DNO on that one - That main incomer is ancient!
@johnlishman4946
@johnlishman4946 Год назад
defo an earth clamp for a main earth on a old cable like that mmmm
@adamsharp201
@adamsharp201 Год назад
Your opinion means nothing unless you are a qualified electrician
@jonathanowens7252
@jonathanowens7252 Год назад
@@adamsharp201 Ok...
@Mainly_Electrical
@Mainly_Electrical Год назад
Jonathan 100% correct
@kristianbarrett7215
@kristianbarrett7215 3 года назад
Great video delroy big fan of yours keep up the good work 👍
@eastwayelectrical
@eastwayelectrical 3 года назад
Cheers Kristian. Thanks for the kind words
@davidclarke2513
@davidclarke2513 Год назад
As a retired sparks of 50 years I have the exact same consumer unit in my house ,its a split board and the 2 rcds and mcbs come with the board ,the problem comes when An mcb develops an earth fault it will trip the rcd therefor disconnecting everything else covered by that rcd .so that sparks swapped the mcbs to rcbs so an earth fault on an individual circuit will only trip that circuit and not multiple circuits but he should have spotted that there was no main earth cable
@Mainly_Electrical
@Mainly_Electrical Год назад
He definitely should .
@IllusivePrime
@IllusivePrime 3 года назад
That Cowboy Sparky who did all that should be in jail for such a crime of a job in the sparky world! Good job on the fix Delroy!
@Awynn0
@Awynn0 Год назад
Sparky?!? Ha, that has 'Builder' written all over it! 😵
@farmersteve129
@farmersteve129 3 года назад
I always try to make a point of checking the earthing & supply arrangements first, otherwise you just end up chasing your tail. Once I know that the earth is satisfactory at the supply end I will move on & do the fault finding at circuit level, it never ceases to amaze me how often I come across a bad main earth!
@richardmennell5745
@richardmennell5745 3 года назад
Great video Del,not sure if your supposed to clamp on to the sheath like that,shouldn’t the DNO be called to install an earth?and the chase going across to your high level tv socket is not in a zone,did you find where all them cables went to in the kitchen?3 cables in each socket and most of them down crazy,the last Electrician wants putting in prison before he kills someone.
@adrianholt1561
@adrianholt1561 2 года назад
Hi ask the DNO to provide an earth they will strip the armour exposing the lead underneath and bond the lead and armours to an earth block. Using the armours alone is the old method and earth may be lost if they corrode at any point.
@johnlishman4946
@johnlishman4946 Год назад
i was think that it's now you have damaged DNO's property it's there cable it's not on our side to just scrape away & hack at there cable
@LAsparkTVWireTestLimited
@LAsparkTVWireTestLimited 3 года назад
How are you sooo relaxed... that was a nightmare!
@Lewdacris916
@Lewdacris916 3 года назад
need to stay calm no matter what or you cant think straight
@jamesarney358
@jamesarney358 3 года назад
The DNO won’t provide an earth as it’s a Pilc service and are not required to provide one. The only options would be an earth stake or request a new a PME service.
@jamesarney358
@jamesarney358 3 года назад
@@totherarf sorry but maybe you didn’t understand. Why would the DNO refuse you a new PME service if you’re happy to pay for one? ie £4000
@jamesarney358
@jamesarney358 3 года назад
It really makes no difference TNS or PME. The network is all PME. That sheath is still connected to neutral in the joint.
@starman_uk
@starman_uk 2 месяца назад
A SNE earth from a PILC service would usually be best endeavour for pre 1972 installs if the joint connection supports it and it passes it would usually be offered but some older networks the (typically legacy ex-DC ones) the lead was not bonded across the old joints so would require either a new connection onto the passing main or at least the old joint dug and cross bonded.
@kingcobrauk
@kingcobrauk 3 года назад
Del didn't hear you ask her "have you done anything to your house before this started" 9x10 they did and that's the problem very strange to get that many faults for no reason over night
@robinmyman
@robinmyman 3 года назад
My last neighbour called me around after they had a kitchen refit. MCB would not turn on for kitchen ring. All sockets in kitchen were dripping wet after tiling. So I pulled them all out to dry out. Next day when they were tidy and dry I put the sockets back in. MCB happy again. Noticed new mini strip lighting under wall units...wondered where they were powered...no plugs. Bell wire from the back of the cooker. Neighbour said leave it...they were professional kitchen fitters...they must know what they are doing. Absolutely flabbergasted.
@bigt6889
@bigt6889 3 года назад
That wouldn't surprise me at all... ive been sent to sort out many a " professional kitchen fitters " work. Joiners should stick to working with wood lol
@Mainly_Electrical
@Mainly_Electrical Год назад
They don't know what there doing
@user-wk7wv8rn8h
@user-wk7wv8rn8h 3 года назад
Looking at the quality of the work there id guess there's a toasty junction box under the floor somewhere
@ABRUSAHAELEKTRIK
@ABRUSAHAELEKTRIK 3 года назад
Nice sharing...
@paulinedaubney8052
@paulinedaubney8052 3 года назад
Poor woman had to pay twice but at least you sussed it ,good job
@alanwalton5735
@alanwalton5735 Год назад
Did my 2391 as part of my training. Was surprised that there was sparks out there without it. Plus there fault finding was 💩 because of it. No wonder that we have installs like this.
@therarmann
@therarmann 3 года назад
did the rcb trip when hitting the test button?
@steverobinson8170
@steverobinson8170 3 года назад
Either originally a TT system or they used the water mains as the main earth .
@daviej8180
@daviej8180 3 года назад
Really common ....I change them everyday
@steverobinson8170
@steverobinson8170 3 года назад
@@daviej8180 always call the dno its a no charge repair and thier ilability do it yourself and an issue occurs its your nuts on the grill
@daviej8180
@daviej8180 3 года назад
@@steverobinson8170 I am the dno
@daviej8180
@daviej8180 3 года назад
@@steverobinson8170 and it does my nut right in when folk stick a bonding clamp on ...most of the time they dont realise the lead is the earth and no the armours
@McMonkeyful
@McMonkeyful 3 года назад
@@steverobinson8170 The DNO will charge for a PME connection, unless there is an existing TNS or TN-C-S that they installed, in which case they're responsible for maintaining it. I'm also DNO. It's possible different regions have different policies on this though.
@shanewilson1160
@shanewilson1160 Год назад
Appreciate the videos. What a lad!
@sticky170
@sticky170 3 года назад
Still think it's a terrible system putting the wires in the wall like that. Over here everything is put in 16 or 19 mm PVC pipe. So if there is any fault you can replace the wiring. I do like the switched and seperately fused outlets.
@McMonkeyful
@McMonkeyful 3 года назад
If US & UK standards got together & combined the best elements of both, it would be the envy of the world. As it is, we both have our own peculiar set of deficiencies.
@HIDLad001
@HIDLad001 Год назад
I like the old metalclad ISCO cut out.
@Kitchentotaste
@Kitchentotaste 3 года назад
This doesn’t surprise me , I meet one Romanian electrician who did 500V DC insulation resistant test without disconnecting the load and was keep asking why he had low IR test results . He blowed up fridge and microwave 🤫
@Mainly_Electrical
@Mainly_Electrical Год назад
Quality 😂
@Chlorate299
@Chlorate299 3 года назад
I suppose one saving grace about these old houses is you can get underneath everything to work on it.
@Frits1975
@Frits1975 3 года назад
Man as a sparky in the Netherlands i'm crying right now!! we only use PVC pipes put into the wall so that the wires can always be accesed or removed. The owner having to fuck all the walls up must have been so painful and costly. Is this UK standard?
@arongretarbjornssonhoiriis3120
@arongretarbjornssonhoiriis3120 3 года назад
I am so surprised how often you come across the cables failing, I have never come across cables/wires failing. unless it is due to mechanical damage. most of the time a faulty on the usage end.
@Will-mp2ij
@Will-mp2ij 3 года назад
Installed by a part p kitchen fitter no doubt..
@martynb9
@martynb9 Год назад
If you were getting the same readings on the old cables does that mean the lack of main earth was the problem all along or did I miss something?
@nitt3rz
@nitt3rz 3 года назад
That amount of damaged cable sounds like either crushed cables, or seriously dodgey junction box
@stephenmorgan1470
@stephenmorgan1470 3 года назад
Nice job so far delroy. Interested to see how you get the cables to the kitchen sockets without wrecking the tiles
@Ragnar8504
@Ragnar8504 3 года назад
I don't think there's anything you can do, unless that wall's plasterboard. Apart from that it's either take the tiles off or go trunking with pattress boxes.
@gbwildlifeuk8269
@gbwildlifeuk8269 Год назад
John wayne must have wired that lot up 😂😂😂
@neiltrevatt
@neiltrevatt 3 года назад
Nice job Del 1thing the tv socket cable when it goes over the top of tv bracket it’s not with in the zone if you had gone left out of low level socket and the straight up to tv you would have been ok
@Improveng1
@Improveng1 3 года назад
Great work Del, and fantastic, chilled attitude and approach.
@Tammas
@Tammas 3 года назад
Call the DNO to provide a proper earth. Of the lead sheath, not the armour :-)
@stephen-truthseeker
@stephen-truthseeker 7 месяцев назад
Spirit orbs.
@Christopher_S
@Christopher_S Год назад
I'm not an electrician, so have no idea what you said. But, from how it looked in the consumer unit I guess it was really really bad.
@CbrigBear87
@CbrigBear87 Год назад
He who dares, wins. Eh, Del?
@stewartthorpe7159
@stewartthorpe7159 27 дней назад
Contact DNO to provide an earth 0.85 is still to high Hessian and 2 x tape armours need to be removed before the correct eli reading can be achieved
@dougaltolan3017
@dougaltolan3017 2 года назад
3:12 LOOK AT THE BUS BAR!!
@ThePa1ch
@ThePa1ch 3 года назад
What on earth is going on with that left hand RCD being used as as a connector block? It looked like there was a neutral joined to the phase of the 32a breaker next to it...
@kevinrobinson6055
@kevinrobinson6055 Год назад
0.8 max tns system Surly that supply authority issue I wouldn’t have left it like that
@malcolmcroll
@malcolmcroll 3 года назад
why can you see the buss bar -any reason Del ?
@Ragnar8504
@Ragnar8504 3 года назад
The idiot put in RCBOs but left a socket circuit(!) with only an MCB??? Why would you put the lounge on a ring? Surely a 20 amp radial would be more than adequate for such a room?
@johnreed8891
@johnreed8891 3 года назад
Coz when the boiler goes down in winter and they plug a couple of 3kw fan heaters in to warm the living room it will overload it.
@seamusellis1450
@seamusellis1450 Год назад
As well as no earth I'd bet that head has DP fusing ...definitely one for the DNO...
@Cornz38
@Cornz38 3 года назад
Hehehe, i had a bad earth, 2 light sockets, 3 feet apart, 11 megaohms resistance between the patress box..
@09weenic
@09weenic 3 года назад
Aggghh - ring circuit faults 😩
@arnoldvanblanken2594
@arnoldvanblanken2594 3 года назад
Very nice video`s!
@arniewheeler4673
@arniewheeler4673 3 года назад
Toolstation board
@ImranKhan-cf8gs
@ImranKhan-cf8gs 3 года назад
Hi delroy I never saw a split load with rccbos madnesses crazy
@jasonhowe1697
@jasonhowe1697 3 года назад
1 is likely being used as a 20 amp fuse
@m101ist
@m101ist 3 года назад
A fire hazards, l can't believe this, they left a fire hazards. 😳
@mikegb1969
@mikegb1969 3 года назад
millions of houses in the uk have no earth . most have had mdpe fitted old lead replaced! and the dno i was told .no oblagtion to supply one £160 to solder to sheath. cannot wait for elec cars most need a very good earth am told. i am not a spark.
@nitrofar34
@nitrofar34 3 года назад
When installing an EV charger they are separated from the main earth anyway in PME arrangements with their own earth rod so it becomes a TT.
@cbcdesign001
@cbcdesign001 3 года назад
@@nitrofar34 Not necessarily, some charge points are connected directly to the existing earthed supply on a pme installation, they have built in pen fault detection so dont require a separate earth rod.
@bonaminhrasmey42
@bonaminhrasmey42 11 месяцев назад
😂could be a different standard electrician 😊
@matharvey87
@matharvey87 3 года назад
Those rcds arnt evan connected 🤭🤔😲
@CraigMansfield
@CraigMansfield 3 года назад
I'd like to see what happened next
@MMG_MoonManGuitar
@MMG_MoonManGuitar 3 года назад
Solid work as always Del. Hope you're keeping well mate.
@eastwayelectrical
@eastwayelectrical 3 года назад
Cheers MMG, very well thanks. How are you?
@mikeZL3XD7029
@mikeZL3XD7029 3 года назад
Mate, Are there that many flex's run all over the floor?
@cogidubnus1953
@cogidubnus1953 3 года назад
According to the opening comments they're unable to draw any power at all from their own board, and are temporarily surviving by means of extension cables from the flat upstairs.
@thomasbyles3075
@thomasbyles3075 3 года назад
I feel so sorry for clients like that, none the wiser to what these ‘electricians’ get up to. Not much you can do in that instants
@McMonkeyful
@McMonkeyful 3 года назад
It's almost worth paying a 2nd electrician to come in afterwards just to check the first one's work. However, if #2 is also a cowboy, they'll probably charge you a small fortune to put #1's bodge job & you have no way of telling whether they're any better
@TheFootballManager11
@TheFootballManager11 Год назад
Swerve that job
@electricalservicesmaroc
@electricalservicesmaroc 3 года назад
HELLO WHAT IS THE NAME OF YOUR CAMERA
@eastwayelectrical
@eastwayelectrical 3 года назад
This was recorded on a Samsung Note 10
@illegalfreedom1055
@illegalfreedom1055 3 года назад
15:20 great use of cable zones 🙄
@nisarhussain4021
@nisarhussain4021 3 года назад
Should ve changed rcbos to mcbs first then you should ve checked rest of the installation.coz there are must be some combine neutral and rcbos would trip no matter what.
@gogosel2705
@gogosel2705 3 года назад
Hi all! What qualifications you need to be a sparky?
@aeameselectrical
@aeameselectrical 3 года назад
None just need to know how to put cupboards on a wall apparently
@tommythomson99
@tommythomson99 3 года назад
Trade skills for you is a good pathway to go.
@MS-Patriot2
@MS-Patriot2 3 года назад
Google EC4U - I was very pleased with their training resulting in Part P Domestic Installer. This is only the beginning, nothing beats on the tools experience.
@adamsharp201
@adamsharp201 Год назад
4 year apprenticeship am2 qualification and then 18th edition electrician installation qualification. Long process mate. Then 2391 and approved recognisition. That's why it's the hardest trade to get
@shredbydaylight8329
@shredbydaylight8329 3 года назад
Could you not have put the link in from the neutral and then you'd have had tncs?
@rickybeans8504
@rickybeans8504 3 года назад
Axiom..... Cheapest brand from toolstation. You know there's gona be dogs hit when the cover comes off
@johngoard8272
@johngoard8272 3 года назад
Hiyya Delroy just how do those cowboys get away with doing jobs like that??
@stuartlee8041
@stuartlee8041 3 года назад
Domestic jobs are such a pain in the arse, no worth the hassle....
@waynenrich
@waynenrich 3 года назад
Looks like a right can of worms
@spookyboo3164
@spookyboo3164 3 года назад
That Florey light fitting wiring is terrible whoever done that wants shoting
@incrediblemichael
@incrediblemichael 3 года назад
an earth fault wtf dangerous and this electrician that this done before him omg momemt
@manwithapan9481
@manwithapan9481 3 года назад
40 years, all this proves is that you don't really need earth :p
@grumpygit447
@grumpygit447 3 года назад
Because he wasn’t an electrician
@arniewheeler4673
@arniewheeler4673 2 года назад
wtf, pointless setup
@daverose4774
@daverose4774 3 года назад
Nice job mate but they are asians so bin it any run away
@donwright3427
@donwright3427 3 года назад
Still safer than installations i seen in some Asian countries .Thank God we got guys like you to keep us safe
@zjzozn
@zjzozn 3 года назад
What a job.... well done to sort that. Perhaps a TT earth system or old earth that used incoming metal water or gas 😳
@trespire
@trespire 3 года назад
Wow. That violation is as seriouse as they come. Diagnostic is half the solution, well done Del !!
@outofrange1982
@outofrange1982 3 года назад
That's why we use tubing inside the walls all the time (it's mandatory), so you can always change, modify or repair any wiring if necessary. It's anyway really strange to see the differences in wiring between different countries. We never use rings and all our houses and flats are always three phase (3x400 Volts, so 230V per Phase)
@thepenguin9
@thepenguin9 Год назад
Typically it's a lot cheaper on the copper to just have a ring circuit
@zaxmaxlax
@zaxmaxlax 8 месяцев назад
​@@thepenguin9In 1950, maybe...? Nowadays its not even 10% of the bill. Did you ever check the price of those gourmet/designer outlets and switches people put in their homes?
@paultipton743
@paultipton743 3 года назад
Is the Cooker hood ok? I was just thinking as it was close to the faulty sockets. Also if you had 36.5 ohms at the sockets on Zs is the Main earthing arrangement a TT system? I've had it at a property where the main earth was wired to the cutout MET terminal as TNC-S but it wasnt connected inside the cutout on the Dno side.
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 3 года назад
Mate you always get these crazy jobs hahaha
@eastwayelectrical
@eastwayelectrical 3 года назад
Tell me about it
@heronimousbrapson863
@heronimousbrapson863 3 года назад
Up until the 1950's, many electric systems here in Canada were unearthed; there wasn't even an earth wire.
@trespire
@trespire 3 года назад
That's mad. Just shows how much the industry has advanced.
@robertmcgibbon7116
@robertmcgibbon7116 2 года назад
As it stands the DNO duse not have to provide an earth if there is no earth ,they will maintain an existing if one's is there
@djb774
@djb774 3 года назад
Actually sh** myself watching this one!
@sdgelectronics
@sdgelectronics 3 года назад
It probably was TT before.
Далее
Unhappy Customer?
11:18
Просмотров 44 тыс.
11 ming dollarlik uzum
00:43
Просмотров 279 тыс.
Катаю тележки  🛒
08:48
Просмотров 225 тыс.
Fuseboard doesn't trip?!?! I wonder why!! Electrician
14:55
Electrician's Job In A Pub Goes Wrong...
17:42
Просмотров 18 тыс.
Customer: "We Could Have Been Electrocuted..."
11:36
Просмотров 14 тыс.
Electrical Emergency! | Electrician's Vlog
20:47
Просмотров 21 тыс.
Electrical Fault Finding UK
24:54
Просмотров 90 тыс.
11 ming dollarlik uzum
00:43
Просмотров 279 тыс.