Cable Termination In Panel | Terminate Medium Voltage Cable | Underground Cable Termination 

MM Asif
Подписаться 29 тыс.
Просмотров 3,4 млн
50% 1

♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE
Hello! Friends I am Muhammad Asif Ek Aur new video♥ Cable Termination In Panel | Terminate Medium Voltage Cable | Underground Cable Termination | MM Asif | ke sath Huzoor Hoon.
In this video, we show you how to terminate a power cable in a transformer And show you how to properly terminate an 13.8KV power cable in a transformer.
This video demonstrates how to terminate medium voltage cables in a panel.
This video demonstrates how to terminate a 500mm power cable using a transformer.
This Video will show you various steps that are involved in Medium Voltage (MV) Cable termination. Hope this is helpful.
This video demonstrates how to terminate medium voltage cable using an underground cable termination method.
Meri video acchi Lage toh please like Kijiye comments kijiye aur mere is channel ko jis ke NAME ♥MM ASIF hy is ko subscribe kijiye Shukriya. aapka Pyara dost Mehar ♥Muhammad Asif.
♥Plz subscribe kijiye
ru-vid.com/show-UCiDA...
♥ ♥ ♥ ♥_____/LINKS\_____♥ ♥ ♥ ♥
► Facebook Page:➜ / mm-asif-564997130539877
► Instagram:➜ / asifshazada. .
► Google+:➜plus.google.com/b/10971302588...
► linkedin:➜linkedin.com/in/mm-asif-918258173
====__|Watch More Videos|__====
♥How To Electrical Pole Size In Urdu/Hindi | Types Of Electrical Pole Stay | Bijli Ka Khamba |
► • How Many Types Of Elec...
♥How To Use High Voltage Tester | Electric Detector Work | High Voltage Detector | Urdu/Hindi
► • High Voltage Detector ...
♥How To CT Energy Meter Connection | 3 Phase CT Meter | CT Installation In Urdu/Hindi |
► • How To CT Energy Meter...
♥How To Cable Size | Cable Size Chart | Cable Size Chart With Load | Cable Size Chart In Urdu/hindi
► • How To Cable Size | Ca...
♥How To Use Hilti Gun | Hilti Nail Gun | Hilti Powdered Actuated Tools | INTRODUCING | Urdu/Hindi
► • How To Use Hilti Gun |...
♥Fire In Electrical Store In Riyadh Saudi Arabi | Al janahain | الجناحین الریاض سعودی عرب
► • Electrical Fire In Wal...
♥Electrical Work Maintenance In Saudi Arabia Urdu/hindi
► • Electrical Maintenance...
♥Fuse Lagaane Ka Tarika 33kv/11kv Urdu/Hindi
► • Electrical Fuse Types ...
♥Track: Weero - Mates [NCS Release]
Music provided by NoCopyrightSounds.
Watch: • Weero - Mates [NCS Rel...
Free Download / Stream: ncs.io/MatesYO
#Cable_Termination
#Underground_Cable_Termination
cable termination in panel, terminate medium voltage cable, underground cable termination,
11kv xlpe armoured cable heat shrink termination
11 KV power cable termination
11 KV underground cable termination
Cable termination kaise kare

Опубликовано:

 

16 янв 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 540   
@Luzgar
@Luzgar Год назад
If you are going to only use music for sound, and if you are going to loop it, please choose a song that is longer than 15s.
@UltraGamma25
@UltraGamma25 Год назад
Yes, it's fucking annoying
@maifeng
@maifeng Год назад
Personally I prefer a good 10s loop to a shitty 5 minutes song
@galaxiedance3135
@galaxiedance3135 Месяц назад
I wanna make that song my ringtone. I had no problem with it. I was actually more interested in what they were doing than listening to the song.
@user-fn8wy4jq1j
@user-fn8wy4jq1j Год назад
Желаю тебе автор этого видео всю оставшуюся жизнь слышать бесконечно музыку из этого произведения!
@rickymundy8663
@rickymundy8663 2 месяца назад
Guys did a good job. I have worked with different companies providing UD training. Some companies don’t provide enough training and the proper tools to properly make these terminations. My experience has taught me that some of the less experienced think that if it holds upon energizing everything is ok. They do not know or realize that improper termination of medium voltage cables with the proper tools will eventually fail prematurely. I came up with I company that provided the training that taught us why we take all the proper steps in UD terminations and the proper tools. While providing training most of those that didn’t follow each step required by manufacturers just didn’t know. Most these guys want to do it right
@mmasif7364
@mmasif7364 2 месяца назад
👍
@fikunademii
@fikunademii Год назад
I just got back from a subsea cable termination for chevron in angola, power and fiber, the experience was awesome
@MW-dd4nd
@MW-dd4nd 22 дня назад
Just out of curiosity, what is your background and how did you get into this? I'm an electrician and high voltage SAP in the UK and would love to see this side of the industry
@unclefatbloke687
@unclefatbloke687 Год назад
Guys, NO! You do NOT use a naked flame on the shrink sleeves!!!! Heat yes; naked flames no!
@aftbit
@aftbit Год назад
9:00 seems like the most dangerous part, both for the cable conductors and the bloke's thumb.
@DrHarryT
@DrHarryT Год назад
Scoring the aluminum when removing the white nylon layer is a no, no. Yes I have done industrial underground power vaults and you don't score the conductor with a blade while removing insulation.
@LordLorenzo834
@LordLorenzo834 7 месяцев назад
Mr pedantic I don't know how you even seen that , a bit of scoring on the cable isn't the end of the world man
@DrHarryT
@DrHarryT 7 месяцев назад
@@LordLorenzo834 Ot's a no no per electrical codes.
@LordLorenzo834
@LordLorenzo834 7 месяцев назад
@@DrHarryT I know I'm an electrician , as long as the cuts are not deep and non of the strands are cut off thus reducing the csa of the conductor which is not gonna happen on cable this size, then it will be fine but I won't disagree with you that its a no no I'm just saying cable this size with a slight mark from a Stanley blade.. not really an issue is it let's use some common sense here
@DrHarryT
@DrHarryT 7 месяцев назад
@@LordLorenzo834 It was well over 30 years ago and I was not actually making the connections but an observer apprentice, Working with MCM1000 AL they had specialized strippers that cut 95% through the plastic rolling it in a circle with end cutter set to the same to cut down the length of the cable so the plastic would easily peel off leaving the AL completely unscathed. The thing about AL is once you score a strand it creates a fracture point when you crank it down in the lug and the strands distort, it can cause strands to fracture/break completely through. AL it brittle like that. Of course you must also use Noalox as I recall.
@frankweatherford6848
@frankweatherford6848 2 месяца назад
Seriously! I built a few load breaks as well. Yes i saw a couple things i would do different but the teamwork housekeeping and attention to detail was pretty damn good. What stood out to me was when my man filed any burrs off lug after crimping. R That spoke volumes. I was trained by 3m and ive had to build these things in nasty paper mills and pwr plants. These guys are better than most of the shit sticks I left behind in contracting. I say if it passed high pot test and im sure it did then good job.
@Gameplayer55055
@Gameplayer55055 Год назад
worst fear: accidentally cut the cable shorter so it doesn't reach the contacts
@j5892000
@j5892000 Год назад
Get so m.h e thick ass solder and a torch lol.
@jannejohansson3383
@jannejohansson3383 Год назад
There's even parts for that, if someone mess up, or changes needed. Otherwise it needs I-joint and some cable, angry boss and try again! $$$
@swsuwave
@swsuwave Год назад
Other worst fear: getting the phase rotation wrong when its done.
@HighestRank
@HighestRank Год назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-f0k2aUizj4s.html
@everydaycompress4259
@everydaycompress4259 Год назад
use extended elbows EZ FIX ...we have even cut off OLD elbows short and still re use the old cable just have new elbows and lightning arresters ..this is just a 3 phase going IN im sure they got 3 more on the other side.
@user-ly9gl8lp9y
@user-ly9gl8lp9y Год назад
Во дела, даже инструкцию прочитали.
@miguellopes4153
@miguellopes4153 3 месяца назад
Parabéns, é satisfatório ver um trabalho desses ser concluído sem falhas. Pernambuco - Brasil.
@user-df1ez2ti3s
@user-df1ez2ti3s 3 месяца назад
"Глаза боятся руки делают" " Опыть приходит годами" "Семь раз отмер, один раз отреж " Музыка несовсем,кто монтировал ролик имей ввиду ! Работа окуратная, хорошая.👍
@AraCarrano
@AraCarrano Год назад
How to derate the line by scoring the outer row of conductors. @ 9:00
@TheHatton7065
@TheHatton7065 8 месяцев назад
Looked like it was done by the bloke with the conduit cutters. Not good
@phonkyfeel1
@phonkyfeel1 2 месяца назад
Doesn’t that cause resistance/heat and worse? I am taking my first electronics class.
@FOH3663
@FOH3663 20 дней назад
​@@phonkyfeel1 It can yes. You just want symmetry in everything ... it can create a failure point.
@psychiatry-is-eugenics
@psychiatry-is-eugenics 19 дней назад
Wonder if there is a better way to do that
@FOH3663
@FOH3663 19 дней назад
@@psychiatry-is-eugenics Just have to be more careful when initially using the cutters ... they dug in too deep. You want to remove the last few mm of material carefully by hand.
@romeowhiskey1146
@romeowhiskey1146 Год назад
You FLICK the switch... The LIGHTS go on! Good work, gentlemen!
@SteelersNSalsa_deMex1co
@SteelersNSalsa_deMex1co 7 дней назад
I service this kind of stuff, my cup of tea.
@AhmadKhan-ce7wx
@AhmadKhan-ce7wx Год назад
ماشاءاللہ میں بھی ریاض میں شرکہ کھربا میں اس کام کی ہیلپری کرتا رھا بہت اچھا کام ھے
@user-nh2ol5us2h
@user-nh2ol5us2h Год назад
интересный вариант полупроводящий слой ножом снимать так бывает на одном кабеле из 100 и не нужно говорить что это только на импортных , так же там инструмент нужен
@mingyitan6388
@mingyitan6388 Год назад
The craftsmanship is very skilled. For future inspection and maintenance, I feel that if the three-color tape is wrapped on the wiring cable to separate the phases, and whether the phase sequence is marked on the cabinet body will be clearer to the staff.
@deang5622
@deang5622 Год назад
No. Phase sequence is not determined by the body of the transformer. Phase sequence is determined by the actual phase of the voltage on the cables. You can actually change the order of the cables connected to the transformer and as long as the output cables are also correspondingly changed, everything is good. So the correct way to indicate the phase of the electricity is to mark the cables first and foremost. You cannot not do that. It must be done.
@rajthanya
@rajthanya 11 месяцев назад
This is a ticking time bomb. Get a qualified Jointor . Jus pay attention to how he removed the seni con layer,This is a NO NO.
@user-cs3el8xr9t
@user-cs3el8xr9t 10 месяцев назад
@@rajthanya с помощью ножниц для резки пластиковых труб... SUPER-EGO не делает инструмент для снятия изоляции с кабелей. Наружные проволоки надрезаны по кругу...
@jenswesterburg18
@jenswesterburg18 9 месяцев назад
Manchmal nervig, aber manchmal auch schön das es hier Standards gibt.... Oh mein Gott ....
@SlickManChoux
@SlickManChoux 5 месяцев назад
Good job guys with adequate toils il would be better
@solvated_photon
@solvated_photon День назад
4:05 it’s better to start tape wrapping at the bottom and move up towards the top. This way each wrap covers the top edge of the last the way that shingles do and help prevent water getting under the tape.
@sebastienghangha3024
@sebastienghangha3024 Год назад
Thanks from France, really good work !
@panoramicview698
@panoramicview698 Месяц назад
Good job. So many unhappy people here seeing work being done well
@mmasif7364
@mmasif7364 Месяц назад
Thank you😍
@rondeal3823
@rondeal3823 5 месяцев назад
Fellas. Think about your eyes . You have flakes of aluminum flying. We always wear eye protection . Especially when cutting wire with saw.
@ZloySok
@ZloySok Год назад
Странно что при таких сечениях кабеля точка контакта совсем маленькая, там где гайка.
@Grishagin1997
@Grishagin1997 Год назад
Это высоковольтка там и не нужно большое сечение, там токи очень маленькие, а вот 0.4кВ уже нужно больше сечение из-за тока
@legendarniyMichail
@legendarniyMichail Год назад
Сечение выбирают исходя из патерь. На длинной линии прийдется переразмерить сечение что бы снизить потери. Иначе ПБВ не хватит и напряжение будет сильно зависить он нагрузки. А гужоны в изоляторах бывают разными здесь видно что тр-р не сильно мощный.
@user-zx4nw1pr6q
@user-zx4nw1pr6q Год назад
Да многое странно! Зачем высокую сторону подключать таким большим сечением провода?, если исходя из расмеров тр-ра, то его мощность не так велика. Еще обратил внимание, что когда закроется крышка, то клеммы окажутся совсем рядом с нею. А заглушки на клемах, это так себе... всёже 14 кВ.
@Grishagin1997
@Grishagin1997 Год назад
​@@user-zx4nw1pr6q расстояние там позволяет, у нас ячейки открываешь и сразу ВН стоит и кабель, и расстояние 10см, про RM6 молчу там еще меньше места, до крышки ячейки, все же нагрузка там есть, по высокой максимум 70А, ТР на видео примерно 1600А по низкой это в районе 2312А
@user-zx4nw1pr6q
@user-zx4nw1pr6q Год назад
@@Grishagin1997 И тем не мение, там сечение минимум 300 квадрат, и на ток в 70А? Ну да ладно. Как говорится, хозяин-барин. А вам спокойной ночи!👋😉
@mikeiver
@mikeiver 8 месяцев назад
Much prefer load break connectors. Fast off and on loaded or not, simple grounding of the cables and the primary for safe service work. Far superior. But good job on this one none the less.
@PATELHARSHOHM2693
@PATELHARSHOHM2693 11 месяцев назад
crimiping start always from bottom of lugs ....like this chance of cable to sleep downwards
@user-sf2bx1dn3h
@user-sf2bx1dn3h Год назад
Professional job well done
@andreymatuznyj1043
@andreymatuznyj1043 Год назад
Я думал, будет вторая серия, третья. А тут , в один ролик уложился ! 23 мужика , две недели ставят розетку ! ВЕЩЬ!!!😂
@slesarg65
@slesarg65 Год назад
У них оплата повременная, это они ещё на обед торопились!
@alvaromachacon6317
@alvaromachacon6317 Год назад
Excelente presentación muy buena gracias
@andyblackpool
@andyblackpool Месяц назад
Very professional and neatly done job.
@noelbyrne8735
@noelbyrne8735 Год назад
Absolutely nothing is right about this installation. 1: wrong type cable for the job, single cores in a trefoil should have been used instead of a multi core cable 2: wrong type termination kit used, a break out or multi to single core kit should have been used which keeps the screen on all the way to the dead break elbow. 3: no grommet or gland used to seal the in enclosure from ingress or moisture 4: the clamp is installed at the crutch which will cause stress and early kit failure Solution: have your technicians trained and educated properly. Government should introduce a standard based apprenticeship system. Follow jointing kit instructions to the letter.
@brettvanwey9419
@brettvanwey9419 Год назад
Y’all did good until you took off the vinyl insulation and went too deep, putting a deep nick in all the outer conductor strands.
@MoritzvonSchweinitz
@MoritzvonSchweinitz 10 месяцев назад
How come they applied (dieletric?) silicone grease to the contact area? Shouldn't grease be applied after making the contact crimping?
@AndyIsHereBoi
@AndyIsHereBoi Месяц назад
I assume they do that to slip the bigger piece over?
@Mabreujf
@Mabreujf 5 месяцев назад
Trabalho bonito e profissional. Parabéns a toda a equipe!
@Ogcbesty
@Ogcbesty 8 дней назад
This is confusing and seemingly good
@claroypunto3774
@claroypunto3774 Год назад
Saludos DESDE BOLIVIA... soy Tecnico Electricista.. muy buen video 👌
@chevypu4
@chevypu4 4 месяца назад
I'm not really qualified to question anything but wouldn't a heat gun be safer than risking frying insulation from the cables?😮😮
@rajatariq6808
@rajatariq6808 10 месяцев назад
Mr Asf I appreciate ur work dedication / tc urself during working
@rajeshs4447
@rajeshs4447 Год назад
Don't put silica grease on conductor,
@rogerdodger3477
@rogerdodger3477 Год назад
I know right? Doh!
@zgrad2008
@zgrad2008 8 месяцев назад
Больше всего мне понравилась идея надеть на контакт "Y1 конденсатор", выполненный в виде внешнего черного корпуса. Вот так и нужно заводить электричество на дачу и в квартиру, т.е. с использованием конденсатора в месте контакта ввода. Не силен в физике, но по-моему по проводкам заземления из кабеля будет уходить на землю вакуум через конденсатор. Было бы любопытно измерить емкость между кабелем и заземлением, наверное ~2nF.
@atnstn
@atnstn 10 месяцев назад
Respectable professionalism. Reall enjoyable watch.
@rajkumarponnuthurai9696
@rajkumarponnuthurai9696 Год назад
Good job 👍 We shall take little more care when sleeving insulations and clamping. Thanks for the video.
@janeli5725
@janeli5725 8 месяцев назад
Nowadays, there is no need for stamping pliers on the terminals. It is safe and fast. Also, the protective cover is not very good if it is heated by fire. Now there are terminals that do not need to be burned. Just put it on and it can be used.
@mohammadhoseinghadirzade-mo3fu
@mohammadhoseinghadirzade-mo3fu 7 месяцев назад
👍👍👏👏بسیارعالی
@kouamekouakouraphael9402
@kouamekouakouraphael9402 7 месяцев назад
❤❤❤ Super
@user-go6gw8qy8j
@user-go6gw8qy8j 8 месяцев назад
I specialize in this! Only minor errors but congrats.
@nb117
@nb117 Год назад
Excellent professional installation.. Good Job!!
@BarfusWOW
@BarfusWOW Год назад
not really - no safety glasses at all anywhere.
@oldtimer2192
@oldtimer2192 Год назад
The cable clamping bracket was pretty average!
@Boraxo
@Boraxo 9 месяцев назад
Did you use a dull axe to cut those holes in the clamp bracket ?
@JustBadMeAndI
@JustBadMeAndI 2 месяца назад
No, they seem to have burnt the holes with a welder
@almosthuman4457
@almosthuman4457 Год назад
its nice to see someone doing things the right way in one of these videos.
@patrickd9551
@patrickd9551 10 месяцев назад
If you want right, you better watch other channels, like jointech cabling. As for the issues: They didn't apply the proper torque spec in the end and they scored the conductor, as you can clearly see around the 9 minute mark.
@CEE-POWER
@CEE-POWER 6 месяцев назад
Nice
@Electricalpower96
@Electricalpower96 4 месяца назад
Mashallah 5000kw good 👍👍@electricalpowerpk
@Alsifer12
@Alsifer12 Год назад
why did they lubricate the exposed part of the cable with silicone this will worsen the contact
@alexs2778
@alexs2778 8 месяцев назад
It's probably has dielectric properties so when tightened IF any is between it shouldn't effect much, on the other hand it should provide waterproofing, oxidation and maybe lessens the chance of arching (not sure how effective on high voltage but on main breaker panel thin layer on rail contacts might prevent arching when breaker is installed in that spot..
@marciojose8993
@marciojose8993 6 месяцев назад
VERY GOOD,,
@SaleemAhmad-dw7dw
@SaleemAhmad-dw7dw Год назад
Very good job
@emrahklc3391
@emrahklc3391 4 месяца назад
Thank you for sharing.
@adrianosantos9709
@adrianosantos9709 8 месяцев назад
Very Good....
@asr1460
@asr1460 Год назад
Чудова робота! Молодці!
@mohbouhouch674
@mohbouhouch674 10 месяцев назад
Good job brothers
@mjaved2978
@mjaved2978 Год назад
Knowledgeable able vedio
@osmanhectormusa8843
@osmanhectormusa8843 6 месяцев назад
Good
@jasondsr.pillora968
@jasondsr.pillora968 Год назад
Good work.
@ronaldviens7862
@ronaldviens7862 День назад
If you start the torch on the shrink tubing at the bottom, you take advantage that heat rises and you won't scorch the shrink tubing. Nothing says "Quality work" better than scorched shrink wrap or nicks in your conductor. And that's a hellacious dielectric. No phase tape. Makes me wonder if this is even in the US. Yeah, there's sharpie letters, but sharpie disappears just cause of the air. And they're pretty strict about phasing your conductors here in the USA.
@tomwright3390
@tomwright3390 4 месяца назад
Nice work but please wear safety glasses especially when using a Sawzall to cut wire!
@Vladynko1
@Vladynko1 Год назад
Nice working.
@doglover5461
@doglover5461 5 месяцев назад
nice video boss
@user-up1yl5vo8t
@user-up1yl5vo8t Год назад
-Эх! желтой изоленты чуток остался. -Ничё, растянем как нибудь.
@user-vi3go1vq7r
@user-vi3go1vq7r Год назад
Изолента не правильная.Должна быть только синяя😂😂😂
@tatangsumarna3850
@tatangsumarna3850 6 месяцев назад
God job brother and bravo every one amin❤
@Raufalktrekalwarkr
@Raufalktrekalwarkr Год назад
السلام علیکم ماشاءاللّٰه‎ ماشاءاللّٰه‎
@x84pav84x
@x84pav84x Год назад
Снимать изоляцию надо не повреждая жилы.
@ilovepizzadoyou
@ilovepizzadoyou Год назад
This is why Pakistan has no running electricity...
@sv9141
@sv9141 3 месяца назад
lovely music
@bstelectronics9627
@bstelectronics9627 Год назад
Before applying silica grease.. Should be rubbed with smooth sand paper on grey layer
@donniedollarhidejr.2766
@donniedollarhidejr.2766 Год назад
No, you shouldn't. One little scar on the dielectric layer and bye bye termination.
@remist
@remist Год назад
why
@theqwert228
@theqwert228 Год назад
I'm an electrician and I work with 10 to 20 kilovolt cabels. This is how not to do it. In fact, I will show this to my colleges and we'll have a laugh over this! 🤣😂 This is a very good example on how not to do. 🤦🤦‍♂🤦‍♀ Update: We all had a laugh! 🤣😂🤣😂🤣😂🤣😂
@popiszo9367
@popiszo9367 Год назад
😋
@paolodolimpio1382
@paolodolimpio1382 Год назад
Crimping the terminal directly on the insulator is an unnecessary risk in my opinion ... it could break !!! for the rest, great manual skills, word of an electrical technician
@sumuduasiri
@sumuduasiri Год назад
Definitely. 🙏
@blackviper7754
@blackviper7754 Год назад
So are you electrician?
@paolodolimpio1382
@paolodolimpio1382 Год назад
@@blackviper7754 Yes I am an electrical technician and I have worked with terminals up to 30KV I have never crimped directly on the insulator above all in glass or porcelain where breakage is at high risk
@johngy6296
@johngy6296 Год назад
@paolo D'Olimpio - I thought the same thing. I’ve seen plenty of cracked bushings cause ground faults, spectacularly.
@dolkong_1049
@dolkong_1049 Год назад
꼼꼼하게 설명 잘해주시네요
@joeldicks2181
@joeldicks2181 Год назад
Great work.
@kiranborhade9079
@kiranborhade9079 11 месяцев назад
Very good
@alassaneniang7669
@alassaneniang7669 6 месяцев назад
Good job
@karl7796
@karl7796 Год назад
You kicked the aluminum conductors with the conduit cutters when you removed the inner insulation layers and you should not use retractable blade cutters on HT cable, there are special knives for removing insulation. Did you put dielectric grease on the TX stems before putting the boots on?
@xaxabdo
@xaxabdo Год назад
Where is the QA at!
@schamberlain1
@schamberlain1 Год назад
They probably don't even have multilins or sweitzers on the high voltage side.
@karl7796
@karl7796 Год назад
@@schamberlain1 I should have said nicked the conductors, but that is what happens if you use a stanley knife to cut through the outer layers. We use to use venitian blind cord to cut through the outer layers, the friction cut through the plastic layers with out damaging the copper conductors.
@XREXP0
@XREXP0 Год назад
This looks like a dry climate
@HighestRank
@HighestRank Год назад
@@XREXP0 It is dry, and so they don't have horizontal venetian blinds, but the vertical ones with a stiff staff to open & close them.
@evgeneevgen8177
@evgeneevgen8177 10 месяцев назад
А инструмент кабельный нет не знаем какой нужно использовать?
@jensschroder8214
@jensschroder8214 8 месяцев назад
Medium high voltage of 13.8 kV. They do a good work
@PplsChampion
@PplsChampion Год назад
good cable music
@juanpablorestrepo5540
@juanpablorestrepo5540 Год назад
Excelente trabajo 👏🏻 👍🏼 💪 pero algo muy importante los EPP Elementos de protección personal ✅️
@HichamChahboun-yj8bt
@HichamChahboun-yj8bt Месяц назад
👍👍👍👏👏
@chinmayasahoo4805
@chinmayasahoo4805 Год назад
All protection is good but earth connection is best important part
@josephsouza2160
@josephsouza2160 Год назад
Excellent job
@delicious_seabass
@delicious_seabass 10 месяцев назад
Three guys to do a one man job an the rest sitting around watching.
@inq752
@inq752 Месяц назад
imagine the GDP growth
@user-gt6sl6bd8n
@user-gt6sl6bd8n 3 месяца назад
Nice 🎉
@restorerestoration4705
@restorerestoration4705 Год назад
lubricating contact joint is priceless 🤦
@NeverTalkToCops1
@NeverTalkToCops1 Год назад
Plus the box cutter technology.
@BramBiesiekierski
@BramBiesiekierski 10 месяцев назад
My favourite was the clamp/strap that secured the cable in. It looks like they drilled the holes by shorting it out on a car battery.
@BramBiesiekierski
@BramBiesiekierski 10 месяцев назад
At 0:51😂
@Gte83497
@Gte83497 Год назад
Да, уж,монтаж кабеля из сшитого полиэтилена это само искусство,сам на монтажника кабельных муфт обучался!
@softbytesunlimited
@softbytesunlimited Год назад
Nice work 👏
@2023TMc
@2023TMc Год назад
No eye protection but hard hats 😂
@HamguyBacon
@HamguyBacon Год назад
Its not live
@lizhageman5457
@lizhageman5457 Год назад
Good work! Big cable, compared to the physical size of the transformer. 500 kcmil @ 13.8 kV, corresponds to 10 mVA?? Transformer seems smaller.
@HichamChahboun-yj8bt
@HichamChahboun-yj8bt Месяц назад
👍👏👏👏
@claudiuserprinse3115
@claudiuserprinse3115 Год назад
very good💪
@lovenkeytermitus673
@lovenkeytermitus673 8 месяцев назад
Nice work ❤
@Ackmipro
@Ackmipro Год назад
Great job
@wwsss8255
@wwsss8255 6 месяцев назад
👍👍👍👍👍💯💯💯💯💯
@TheGodpharma
@TheGodpharma Год назад
How do you know which cable is which? They all seem to be identical.
@christopherleubner6633
@christopherleubner6633 Год назад
Excellent work. It might get a fault but it sure AF isn't going to be the primary feed connection 😎
@patrickd9551
@patrickd9551 10 месяцев назад
You sure? Did you see them apply proper torque on the bolts using the proper tool? Did you not see the scoring of the outer conductor @9:00? I sure as heck did not. So if you please, would you guide me to those missing pieces?
@Milten130
@Milten130 10 месяцев назад
@@patrickd9551 also resistance to ground is not important there, they can just go by with crusty torch cut metal pieces
@patrickd9551
@patrickd9551 10 месяцев назад
@@Milten130 true story: I went to an outdoor lan party back in 2000. Big army tent, diesel gens, etc. The power was ..... bad. Loads of parasitic voltage through the earth lead. So we all tied our computers to a piece of UTP cable and wrapped it around a couple of tent pegs. Then through the magic of powerstrips, all our computers were all cross-connected to many small grounds. It was enough from getting us zapped by our own computers tho, as stupid as it looked.
@briwire138
@briwire138 10 месяцев назад
great job lads.
Далее
Replacing a Pad Mounted Residential Transformer
10:20
How Do Substations Work?
12:38
Просмотров 3,2 млн
BRAWL STARS x DRAGONFORCE: A Draco Tale
03:46
Просмотров 10 млн
Мама ударила дочь #shorts #iribaby
00:17
Switching 11kV VCB Tamco
7:34
Просмотров 2,4 млн
How to Safely Shutdown and Reenergize Switchgear
3:28
A closer look at Padmount Transformers
10:15
Просмотров 630 тыс.
Ensto cold shrink termination - Installation
5:13
Просмотров 20 тыс.