Calibrating a Test Mark Pressure Meter 

Test Mark Industries
Подписаться 143
Просмотров 40 тыс.
50% 1

Informational video on how to calibrate a Test Mark concrete pressure meter.

Опубликовано:

 

25 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@jesusglopez8430
@jesusglopez8430 2 года назад
Thanks for sharing, very Educative and Informative.
@winnipegkevin1
@winnipegkevin1 7 лет назад
Nice video. If had to make any needle adjustments during calibration, I would be re-checking my IP to make sure all is still well. I have never seen the glass-plate method mentioned by other commentators. Not the common procedure around here, I guess. Sounds like more trouble with glass plate and a scale.
@samanthatreutel1609
@samanthatreutel1609 12 лет назад
There are a number of variables related to the exact volume of the water needed to fill bowl and the amount needed to extracted to check throughout the range of operation. The water should have all air evacuated and be at room temperature. The empty meter should be weighed and then filled with water and weighed again with the weight of water needed to fill the bowl. That weight times the percentage within the range of operation of the check gives the weight of water to remove for each percentage
@kromekicks
@kromekicks 6 лет назад
What does it mean, if when I open the petcock (to fill cylinder) and it automatically fills the cylinder. Without the need to push down on the main air valve. Any help would be appreciated. Thanks
@markbalcom5408
@markbalcom5408 7 лет назад
you talk about adjusting the tabs if the gauge doesn't read zero, can you talk about that, also every video I have seen on air meter calibration does it on a new meter, that's easy to do, doing one on a meter that's been used and abused is a little harder.
@LuisAntonioCastelletFernandez
@LuisAntonioCastelletFernandez 2 месяца назад
Calibración C0170/F
@tariqabdullah3091
@tariqabdullah3091 8 лет назад
I want aggregate correction factor
@captnhowdy01able
@captnhowdy01able 8 лет назад
the calibration procedure is wrong, where is your glass plate to make sure you have zero air? and when filling the meter with the tube you are suppose jar it as you add water shaking it introduces air into the system, and where is your weights for empty vessel with plate? and empty vessel with water and plate? you need those to calculate actual reading against gauge reading
@magdymohamed1640
@magdymohamed1640 5 лет назад
Very good
@jeffreysouth
@jeffreysouth 11 лет назад
What is the volume of the graduated cylinder? Once you adjust it to 5% does that mean that your initial pressure is calibrated to 3%?
@jamesm1651
@jamesm1651 3 года назад
in ASTM C231 (Section 8.3.2.1) states "Jar the meter gently until all air is expelled from this same petcock." You are not supposed to shake it like that
@jamesm1651
@jamesm1651 3 года назад
Also petcocks should sty open while you pump air into the chamber. That way you know if the pump is leaking
@joshl90
@joshl90 5 лет назад
Water not confirmed to be 23.0 C. No weighing of the discharged water in the graduated cylinder? No calculating air content by water discharged? No check at 10%? This was not done in accordance with ASTM
@aseeroha
@aseeroha 7 лет назад
Is that per ASTM C231?
Далее
ASTM C173-Air Content of Concrete-Volume Air Meter
19:06
Blackboard ASTM C138
16:46
Просмотров 55 тыс.
NPC Bloxfruits🤖🔥| Doge Gaming
00:13
Просмотров 1,6 млн
Pressure Meter Calibration
7:11
Просмотров 10 тыс.
Type B Pressure Air Meter Assembly
3:56
Просмотров 2 тыс.
Quality Control of Concrete On Site (Part 1)
14:44
Просмотров 187 тыс.
pressuremeter
11:52
Просмотров 2,7 тыс.