Тёмный
No video :(

Checking on a gas pack Adjusting gas pressure with fieldpiece SDMN6. Abnormal flame caught on camera 

HVAC GUY
Подписаться 66 тыс.
Просмотров 8 тыс.
50% 1

I was called out to this call because there was no heat in the morning. It later started to produce heat. I still checked on it. I adjusted gas pressure with the fieldpiece SDMN6. Found a very rusty heat shield, which I replaced. I also noted an abnormal flame in the first burner. #hvac #hvaclife #fieldpiece #rheem #SDMN6 #makita

Опубликовано:

 

5 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 35   
@k-laus9435
@k-laus9435 7 месяцев назад
As a service manager now after being in the field for last 29 years the toughest thing to deal with is getting younger techs to take the effort to do the calls the RIGHT way. Taking the time and energy to check all of the unit like this heatexchanger inspection. The extra effort not to bail on it even though things like rotted screws get in the way. “Well I wasn’t there for that” is the go-to response when the call comes back in.
@camolance
@camolance 5 месяцев назад
Wanting the techs to do a detailed checks on all calls is fine , but are the techs giving enough time to do all that or they are bambarge with calls , repairs and maintenance all in one day ?
@tyleraustin4720
@tyleraustin4720 Год назад
Hello sir I just want to thank you for posting this info. I learn from you're daily experiences as a relatively new tech. As a prior service member I see the attention to detail you share. Thanks again.
@brianporter4352
@brianporter4352 2 года назад
I work for a Rheem dealer in Burlington NC, and we service a lot of gas packs like this. I find that the stainless steel heat exchangers are very robust, but like you mentioned in the video, they tend to fail on the backplate. The radiation shield is a commonly replaced part, because they are a sacrificial lamb so to say. Always rusting out. We carry them as part of our truck stock. The Rheem/Ruud packs are very easy to work on though, and very easy to diagnose problems. Great video, thanks for sharing your knowledge. What you work on is pretty much what I work on here in NC
@HVACGUY
@HVACGUY 2 года назад
Thanks for watching
@1776cootsflybynight
@1776cootsflybynight 2 года назад
I saw it! You have quickly became one of my favorite hvac channels. I was cleaning out my van this afternoon and was listening to an older video of yours where you had metallica playing in your van. Rock on 🤘
@jimsumner7360
@jimsumner7360 4 месяца назад
I guess I missed where you cleaned flame sensor, burners, brass orifice, vacuum port on draft motor 😂
@realestateservicessaleshea99
@realestateservicessaleshea99 2 года назад
That's close to condemnable from here ,looks like it's not gonna be to long before the scrap yard calls!🤔🤣 Thanks again for the videos! 🍺🍺🍺🥃🥃🎯🍿 Retired (werk'n)keyboard super tech. Wear your safety glasses!
@Parabellum-X
@Parabellum-X Год назад
That 2000, 3.5-ton gas pack had the most rusty-lookin coil I have ever seen.
@hughholt121
@hughholt121 2 года назад
Nice work Bud. Another combo unit. Thanks for posting
@boby115
@boby115 2 года назад
I am a little concerned with your startup pressure. Next time you do this you should take pressures from both sides, Inlet and Outlet gas pressures on that valve. Sometimes the gas company has a problem with something called a creeping regulator ( when the unit is turned off the pressure on the inlet side should escalate a little bit and then lock up, we call this lockup pressure but in the event the pressure keeps escalating a little bit and a little bit more and a little bit more we call this a creeping regulator and the gas utility should be contacted about a possible pressure problem). Hope this information helps and stay safe out there 👍🛠. PS- you may want to use your CO2 condensate drain cleaner on the burner Venturis in order to clean any debris or spider webs🕸🕷.
@HVACGUY
@HVACGUY 2 года назад
Thanks, I’m always open to help.
@boby115
@boby115 2 года назад
@@HVACGUY , just sharing information and experiences. Thank you for sharing your experiences, knowledge and RU-vid content👍🛠.
@throttlebottle5906
@throttlebottle5906 2 года назад
something looks fishy there for sure, I've seen bugs and people painting meters fill the regulator vent screens with paint/mud daubers and make it react very slow and over-pressure. for sure need to check incoming and manifold outlet, as that could be gas co. regulator or the gas valve itself. not good either way.
@boby115
@boby115 2 года назад
@@throttlebottle5906 , you're absolutely right. I was a first responder / service technician 35 years for the full service gas utility in St Louis, Missouri and probably replaced well over 20, 000 Regulators in my career. Everything you said is all possible causes and one of the most common causes is as simple as debris on the regulator seat or a torn regulator seat ,this is why taking inlet pressures (lock up & working) is so important.👍🛠.
@johnwalker890
@johnwalker890 2 года назад
Good job Curtis.
@thesilentonevictor
@thesilentonevictor 2 года назад
Good work on this one
@ReliableHVACR
@ReliableHVACR 2 года назад
Nice one
@carlossaenz4075
@carlossaenz4075 4 месяца назад
U also need to do close up at to where u put the hose at the gas valve and the adjustment place
@graymodeler
@graymodeler 2 года назад
Might have been a spider web in the burner. I saw it too.
@johnthomson3691
@johnthomson3691 Год назад
Compressor variable control
@stevealoia
@stevealoia Год назад
I seen a flash on the left burner
@seadeas
@seadeas 2 года назад
👍
@Jack-ur6gx
@Jack-ur6gx 2 года назад
I've had that happen to me on a conversion, gas pressure was too low. That low starting pressure likely issue, gas valve might be faulty.
@HVACGUY
@HVACGUY 2 года назад
Yes, I agree.
@joehead1294
@joehead1294 2 года назад
Those bells ringing was kinda nice. Must be a church close by?
@HVACGUY
@HVACGUY 2 года назад
Right across the street
@hvaclifeatx7012
@hvaclifeatx7012 2 года назад
👍🏻💯
@danbell1733
@danbell1733 2 года назад
👍nice! Thank u
@carlossaenz4075
@carlossaenz4075 4 месяца назад
Burners need to cleaned !!!!!
@carlossaenz4075
@carlossaenz4075 4 месяца назад
Roll out
@tomwalker9184
@tomwalker9184 2 года назад
Is that coupling Allowed in the fire box area???
@HVACGUY
@HVACGUY 2 года назад
Locally, yes. I think that gas code says different though.
Далее
Checking Furnace Pressure Switches
10:53
Просмотров 49 тыс.
Fieldpiece SDMN6 Review EP23
14:40
Просмотров 15 тыс.
Measuring & Adjusting Furnace Gas Pressure X2
12:28
Просмотров 69 тыс.
Adjusting Honeywell VR8000 Series Gas Control Valves
11:08
Fieldpiece Pressure Switch and manometer tool
10:17
Просмотров 7 тыс.