Тёмный

Choosing the Right Fuse Type for Off-Grid Solar: Expert Guide for 12V to 48V Battery Systems 

Cleversolarpower by Nick
Подписаться 58 тыс.
Просмотров 15 тыс.
50% 1

Опубликовано:

 

7 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 47   
@cleversolarpower
@cleversolarpower 8 месяцев назад
UPDATE: the NH00-fuse has an Icc of 25.000A, not 120.000A as stated in the video. 🎁 Free diagrams: cleversolarpower.com/free-diagrams/ 📖 My best-selling book: cleversolarpower.com/off-grid-solar-power-simplified
@The_Unobtainium
@The_Unobtainium 10 дней назад
This is the best summary in this subject so far! Thank you.
@SiBex_ovh
@SiBex_ovh 4 месяца назад
If you show a example with Rate Table for ex. Class-T then this video will be perfection.
@rorymax8233
@rorymax8233 4 месяца назад
Interesting and valuable information, thank you.
@davidcromapix9083
@davidcromapix9083 4 месяца назад
Thanks , very useful data.
@Sydneywizard
@Sydneywizard 8 месяцев назад
Thanks for sharing and educating us with your knowledge. Its much appreciated and Merry Christmas to you.
@cleversolarpower
@cleversolarpower 8 месяцев назад
Thank you! Happy holidays!
@magi-jd2ug
@magi-jd2ug 21 день назад
You better make sure your recommendations are correct, the NH00 fuse from siemens does not have an ICC of 120kA at DC voltage, it's only 25kA. Have a look in the datasheet.
@cleversolarpower
@cleversolarpower 20 дней назад
Yes indeed, the DC Icc is 25kA. I didn't make the distinction between AC and DC. Thanks for your comment.
@caseyl3631
@caseyl3631 Месяц назад
are there resetable fuses / breakers out there that you recommend that can do 300amps or more?
@TexasStatesman
@TexasStatesman 3 дня назад
Renogy sells an ANL fuse rated for 72v and provides a spec sheet. I'd be interested in your thoughts on. It is the only ANL fuse I can find rated more than 24v. Thanks for the valuable information.
@Electronzap
@Electronzap 7 месяцев назад
Good info.
@2hotscottpro
@2hotscottpro 8 месяцев назад
Good info.I was looking to upgrade fuses and battery shut-offs.I have cheap fuse you showed ,top left one showed in group of 4. My positive shut off post gets warm from 800 watts using 1500 watt heater on low.I know heat makes them fall apart.Bussman 187 series push button disconnects are $55.
@cleversolarpower
@cleversolarpower 8 месяцев назад
I recommend using the disconnects switches from bluesea systems. They have less resistance. Read my article on my website about 'how to calculate power loss in a circuit'
@finleyandtom
@finleyandtom 6 месяцев назад
Thanks for a super clear and informative video - So i am correct im thinking that with a 12v 105ah lithium battery i would be ok to fuse the main connection from the battery with a suitably sized midi or mega fuse ? 105x10 = 1050 amps max during short - IIC for a midi fuse is 5000A and 2000A for a mega
@cleversolarpower
@cleversolarpower 6 месяцев назад
That is correct.
@laurentsosson1739
@laurentsosson1739 3 месяца назад
Hello and congratulations for the tests with the fuse I would like to ask you something I have a large LFP battery pack (EVE 280K) in 9S 4P or 28 volts 1120AH and my voltage converter is 4000 watts to 28 volts which fuse do you recommend between the + of the converter? 150A? fuse like yours or a fixed fuse like VICTRON? THANKS laurent
@The_Unobtainium
@The_Unobtainium 10 дней назад
Where can you find T-class for $40? I'm just checking T-class JJS-350A/60/V and it is...$250! a piece😢 the fuse blosk itself is $120. So expensive.
@cleversolarpower
@cleversolarpower 10 дней назад
Try Amazon. You can try nh00 fuses as well, they are close to being the same.
@The_Unobtainium
@The_Unobtainium 10 дней назад
@@cleversolarpower yeah, trying but if you want to go for 200A+ mark for DC the prices are kinda shocking
@simon359
@simon359 8 месяцев назад
A lot of the 48 V systems I see use mega fuses, and I didn’t see what you recommended for charge controllers? 48 V system in USA
@cleversolarpower
@cleversolarpower 8 месяцев назад
Some mega fuses are rated for 58V. But people copy from other setups, so they can be faulty. 58V rated mega or midi fuse for charge controllers.
@URackADisciprine
@URackADisciprine 8 месяцев назад
I have found Class-T fuses lower than 100A from Bussman and LittelFuse in my searches. Am looking to get an 80A (something like LittelFuse JLLN080P 80A 200KA) for a 48V LiFePO4 battery but no clue which holders will work with that. Wish they were sold as a pair.
@cleversolarpower
@cleversolarpower 8 месяцев назад
The holders are sold separately. Make sure you got the right one. There are different ones for different currents. I think there are two types sold by bluesea systems.
@URackADisciprine
@URackADisciprine 8 месяцев назад
There are two from Blue Sea systems, they are both too large. One is for 110-200A and the other is from 225-400A. I can't find the one I need which is for 70-100A.
@TheFlashmark
@TheFlashmark 5 месяцев назад
Why we can't use ANL fuse for 48v LifePO4 batteries pack?
@cleversolarpower
@cleversolarpower 5 месяцев назад
The Icc rating of an ANL fuse is too low.
@ML-hf6ii
@ML-hf6ii 2 месяца назад
@@cleversolarpower why then victron use them? for example they recomend using "Victron ANL 80V 48V"
@deanb949
@deanb949 2 месяца назад
​@@ML-hf6ii I experienced the re-bridging of the fuse element when I used a 80 amp ANL on my 48 volt AGM pack. I had used the ANL as a temporary fuse and it became the permanent. One time my voltage was low on batteries, I plugged into shore/ utility to recharge and that higher than normal current took out the 80 amp ANL, which was still arcing after the main element blew. This video has great info.
@deanb949
@deanb949 7 дней назад
@@ML-hf6ii You can trust Victron's product to perform as they specify by way of their reputation. 95% of other ANL fuses are no name copies. I'm sure Victron can elaborate on how their ANL fuse is higher voltage capable.
@ML-hf6ii
@ML-hf6ii 7 дней назад
@@deanb949 read comment above
@mopikozz
@mopikozz 2 месяца назад
Why do i use some people using DC circuit breaker instead of fuse? Isnt DC breaker better in the sense its not single use?
@cleversolarpower
@cleversolarpower 2 месяца назад
Normally we use fuses with DC because it's cheaper. And they are not blowing. AC breakers can blow more often so we use breakers.
@fc436
@fc436 7 месяцев назад
my 100a nh have 120kA at 500v dc icc
@magi-jd2ug
@magi-jd2ug 21 день назад
What fuse is that exactly? I quite positive that is AC only (120kA ICC).
@ZIlberbot
@ZIlberbot 6 месяцев назад
except choosing fuse 10 times more than battery capacity, there should be like a precise formula with battery voltage as well, as energy of short circuit battery or power source is Amperage x Voltage x time ....
@cleversolarpower
@cleversolarpower 6 месяцев назад
It is not the fuse rating. It is the short circuit fuse rating, these two are totally different. As you can see on the table different voltages have different short circuit current.
@ML-hf6ii
@ML-hf6ii 2 месяца назад
there are a lot anl fuses for 48V. Why I can't use them?
@cleversolarpower
@cleversolarpower 2 месяца назад
You can if they are rated for 58V. Most are not. ICC also plays a role.
@2hotscottpro
@2hotscottpro 6 месяцев назад
What size fuse for 920ah 48v is why I’m here.
@cleversolarpower
@cleversolarpower 6 месяцев назад
You need to figure out what load you want to power for the fuse size. For the fuse type, you likely need class-t or NH if it's lithium.
@2hotscottpro
@2hotscottpro 6 месяцев назад
@@cleversolarpower 6k watt inverter with Li bat
@npvols4321
@npvols4321 5 месяцев назад
Please help, i have a 5000watt inverter, 4 x 200 amp hour AGM batteries , and 4 230 watt panels. I think i need a 400amp Class T fuse, but i dont know where to put it ? 12v system Please advise.
@jamesmason7124
@jamesmason7124 2 месяца назад
No further than 2 feet from the battery but as close as you can and on the positive cable
@johntheaccountant5594
@johntheaccountant5594 8 месяцев назад
Why can you not use an MCB instead of a fuse?
@cleversolarpower
@cleversolarpower 8 месяцев назад
An MCB is more expensive than a fuse. MCB's are used in AC switchboards. In a DC circuit the fuse wil seldom trip, so that's why we use a fuse. However, and MCB is used as a disconnect between the solar panels and charge controller.
@johntheaccountant5594
@johntheaccountant5594 8 месяцев назад
@@cleversolarpower when you were saying "fuse/breaker" is US$15 dollars, I was thinking that an AC MCB is US$6 and doesn't have to be replaced when it activates.
Далее
How Many Batteries For a 3000W Inverter?
6:09
Просмотров 913 тыс.
Я ж идеальный?😂
00:32
Просмотров 143 тыс.
🛑 ты за кого?
00:11
Просмотров 75 тыс.
Testing 100A Fuses with 100A of current.
9:23
Просмотров 97 тыс.
Fusing Of A Different Sort: MRBF Fuses
7:22
Просмотров 14 тыс.
12V, 24V, or 48V Battery for Off-Grid Solar Power
9:41
How Many Solar Panels to Charge a Battery?
7:16
Просмотров 67 тыс.
How Many 12V Batteries for 3000W Inverter
15:26
Просмотров 91 тыс.
How To Properly Fuse A DIY Solar Panel Array
9:17
Просмотров 53 тыс.
1000W Inverter: How Many Batteries You Really Need
4:54