This video shows how to connect a KEB F5 VFD, inverter or other device to Combivis 6 automation software.
This first video will show you the cables required to connect the device to your computer running the Combivis program.
#Combivis #cables #Software
Part and Part Number Listed in Video:
KEB USB-to-serial adapter: 0058060-0040
RJ45 adapter: 00F50C0-0020
Combivis cable (DIN 66019II - RS-232 cable) part number: 0058025-001D
USB-to-serial adapter with FTDI chipset: 0000000-7938
KEB Products shown in the video:
www.kebamerica...
KEB software in the video:
www.kebamerica...
► Subscribe to Our Channel Here: www.youtube.com...
-- Follow KEB America Here --
Website: www.kebamerica...
LinkedIn: / keb-america-inc
Facebook: / kebamericainc
Twitter: / kebamerica
Instagram: / keb_america

Опубликовано:

 

3 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@Aaaaaasssssss382
@Aaaaaasssssss382 5 месяцев назад
HI, thank you for the useful video, i have 24F5 KEB SERVODRIVE used in haitian injection machine, i installed and activated the software, I already have the YELLOW RJ45 TO RS232 CABLE BY KEB AND A GENERIC RS232 TO USB CABLE BUT WHEN I POWER THE DRIVE ON AND try to communicate with pc i fail???? no keb device detected after the scan can you give me a hint
@KEBAmerica
@KEBAmerica 5 месяцев назад
Have you contacted Haitian about this issue? I would first contact them as the machine manufacturer for help. If they cannot find a solution for you, reach out to the KEB subsidiary near you. If you are in North America, please contact us through our website: www.kebamerica.com/contact
@estebine1609
@estebine1609 3 года назад
Hello for an S4 can you tell me what cable I need?
@sirojiddinsoatov7178
@sirojiddinsoatov7178 6 месяцев назад
Hi i need your help. Our company has many KEB F5 inverters. We want to replace them with a new one, but the program cannot be transferred to the new one.
@KEBAmerica
@KEBAmerica 5 месяцев назад
Thanks for your question. If you have not received help with your need to replace your F5 inverters, please contact a local KEB representative near you. If you are in North America you can contact us here: www.kebamerica.com/contact/
@tlaxca87
@tlaxca87 3 года назад
Hello, can I use the port X6B in the 00.F5.060-5010 Operator panel for communicate with the PC ( using the correct cables)?
@KEBAmerica
@KEBAmerica 3 года назад
That's correct. You would need the cables in the Combivis starter kit (CV58060-USBC). Contact your local KEB distributor to get this kit. If you're in North America, find a local distributor on this webpage: www.kebamerica.com/contact
@nadeemahmed4427
@nadeemahmed4427 3 года назад
Hi... thank you for the video tutorial, in the video, u gave instructions on connection with (operator F5 CAN ) but I have Operator F5 Powerlink Material no: 00F5060-H000. could you please share a link for how to establish a connection using RJ45 with the operator F5 Powerlink. thanks in advance for your support.
@KEBAmerica
@KEBAmerica 3 года назад
Hay Nadeem, I don’t think I understand your question. Video doesn’t specify CAN anywhere and there is nothing unique about the connection to the Powerlink operator. The video shows you how to connect to your computer using the RJ45 connection. The part numbers are in the description of the video. You will need a (1) KEB USB-to-serial adapter and, (2) an RJ45 adapter. Contact a local KEB rep to get these parts. Have a great day.
@rishinathreghu579
@rishinathreghu579 2 года назад
hi , i am unabe to connect keb f5 ,operator 00f5060-2014 with pc. iam using a rs232 to usb converter(ut-8801).thanks in advance
@KEBAmerica
@KEBAmerica 2 года назад
If you are located in North America, go to www.kebamerica.com/contact If you are outside North America, please contact a local KEB representative for specific application questions. Thank you. www.keb.co.uk/contact/contact-worldwide
@manaspatwardhan8241
@manaspatwardhan8241 5 лет назад
Can I connect HSP5 cable to serial cable and serial cable directly to my pc? As my PC has serial port.
@KEBAmerica
@KEBAmerica 5 лет назад
Safe answer is no, but how you want to connect isn’t 100% clear. We believe you are wondering about replacing the blue USB to Serial converter with a standard serial cable. That is not possible. If you would like a more in-depth answer, you may contact a local KEB Representative here: www.keb.de/company/representatives-agencies
@shahed2535
@shahed2535 4 года назад
If we use RS232 to usd adapter wifh Prolific PL2303 chipset, can we connect the F5 drive?
@KEBAmerica
@KEBAmerica 4 года назад
USB to Serial Adapter requires an FTDI chipset to work with our drives/Combivis. We cannot guarantee any specific 3rd party cable will work and strongly recommend our USB to Serial Converter. Hope this helps. Thanks for the question.
@ghouseahmed4u
@ghouseahmed4u 3 года назад
I have a USB to Serial converter with FTDI chipset, which is functioning well in all my industrial needs, now i want to know that whether i can connect "Combivis 6 software with KEB16F5A1E-34GA" whose version on drive name plate is Blank (without anything written). Can you Please guide me.....
@KEBAmerica
@KEBAmerica 3 года назад
Hello. Thanks for your question. Connecting to this drive without knowing the nameplate data depends on the operator used (p/n 00F5060-xxxx). Only the -2000 operator would work without an additional cable. Also while the FTDI chipset is required for the cable to work, there is no guarantee a generic cable will work properly. Recommendation would be to order the Combivis Starter Kit (CV58060-USBC). If you need more info please contact us via email or phone and talk with an application engineer.
@ghouseahmed4u
@ghouseahmed4u 3 года назад
@@KEBAmerica Thank you for Reply, i will try
@viethuynhquocviet107
@viethuynhquocviet107 3 года назад
Please, You guide me to copy parameters from old_inverter to new_Inverter (same series/power... F5-combiver) by KEYBOARD, thanks
@KEBAmerica
@KEBAmerica 3 года назад
The best way to find a solution for your application is to contact a KEB engineer through our website here: www.kebamerica.com/contact/
@javaidaslam1804
@javaidaslam1804 4 года назад
sir if i use rs232 usb adapter with db9 conntor cable can he will online vfd
@javaidaslam1804
@javaidaslam1804 4 года назад
plz reply
@KEBAmerica
@KEBAmerica 4 года назад
Hello Javaid, Thank you for your question. You will need to clarify a few things in your comment: 1. If you use a USB to serial adaptor, it must have an FTDI chipset. For example, the USB to serial adaptors you would get from Office Max would not be made for industrial applications and most likely would not work. 2. A straight serial cable will not work. To connect to the drive using a serial operator, you would need to use a serial cable wired with pins 2-2, 3-3 and 5-7 (PC side-Drive side). 3. As mentioned above, you would need a serial operator as well. A better option is to use our new USB to serial converter part number CV58060-USBC. The USB converter can connect to the drive in multiple ways so gives more flexibility to cover all applications. We hope this helps clarify your needs to connect to a KEB VFD. You can always contact a local KEB Representative here: www.keb.co.uk/company/representatives-agencies
@md.belaluddin4099
@md.belaluddin4099 4 года назад
do not progam display cp....,display program it th. 07 how problam it please.
@KEBAmerica
@KEBAmerica 4 года назад
Hello, and thank you for your comment. If you would like to find a solution to a technical problem like the one you are describing, contact a local KEB Representative using this link: www.keb.co.uk/company/representatives-agencies
@mdadilrameezkhan
@mdadilrameezkhan 2 года назад
sir i want to purchase keb cable
@KEBAmerica
@KEBAmerica 2 года назад
You can contact a local KEB representative or distributor. See the part number in the description of this video and contact a KEB rep. here: www.keb.co.uk/contact/contact-worldwide
@vaithisub
@vaithisub 4 года назад
I have a keb f5 vfd with e66 error how to solve
@KEBAmerica
@KEBAmerica 4 года назад
We serve the North American market (US and Canada) to find a local KEB Representative go here: www.keb.co.uk/company/representatives-agencies
@ketanpatel1245
@ketanpatel1245 5 лет назад
Dear sir. Please explain in Hindi
@KEBAmerica
@KEBAmerica 5 лет назад
Hello Ketan, We are KEB America. If you would like to learn how to do this in Hindi you can contact a local KEB Representitive: www.keb.de/company/representatives-agencies Thanks You.
Далее
The RS-232 protocol
26:10
Просмотров 843 тыс.
КОГДА НАКРОШИЛ НА ПОЛ #shorts
00:19
Просмотров 684 тыс.
У КОТЕНКА ПРОБЛЕМА?#cat
00:18
Просмотров 633 тыс.
How to Wire Sensors to a PLC - Part 1
5:44
Просмотров 440 тыс.
CAN Bus Explained - A Simple Intro [v2.0 | 2021] 🌟
14:44