Тёмный
No video :(

Continental drawer freezer - it’s a mystery 

Restaurant Repairs
Подписаться 6 тыс.
Просмотров 1,1 тыс.
50% 1

Опубликовано:

 

7 мар 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@briancarlisi2224
@briancarlisi2224 5 месяцев назад
Excellent troubleshooting with explanations. Keep these coming. Very helpful. Thanks!!
@restaurantrepairs
@restaurantrepairs 5 месяцев назад
🥳
@justanoldhandyman
@justanoldhandyman 5 месяцев назад
Thanks for sharing.👍
@mxslick50
@mxslick50 5 месяцев назад
That original red wire to the outlet was correct, but the outlet itself still had the jumper tab intact (ties the top and bottom hot side together) Which meant that the compressor was getting a constant 120v from the "Vaporizer" side, which I am willing to bet is supposed to be constantly hot. I also see that the old defrost timer had caught fire as well. And the rest of the wiring in that thing is a deathtrap...time to rework it or retire it.
@restaurantrepairs
@restaurantrepairs 5 месяцев назад
Yep. Found out the in house replaced the outlet with a regular
@MrMultitool
@MrMultitool 5 месяцев назад
It would have been fine if the tab had been removed. You did a good job@@restaurantrepairs
@restaurantrepairs
@restaurantrepairs 5 месяцев назад
@MrMultitool Thanks. I get there eventually. 🤣👍🏼
@inothome
@inothome 5 месяцев назад
Agreed, the tab wasn't cut and regular outlets usually have that tab. EDIT: Just have to be careful with the neutral side. Sometimes you cut the hot and share a neutral, sometimes both are cut with a separate neutral. Obviously, just cut what was cut on the original when replacing.
@hvacrnortheastern2110
@hvacrnortheastern2110 5 месяцев назад
Draws are worst thing to repair because there no room .
@berylwhite2983
@berylwhite2983 5 месяцев назад
Great work you did some great troubleshooting. I think anybody ought to hire you!😊 But I did notice all that ice that looks like you when you walk out and it's like 20°
@restaurantrepairs
@restaurantrepairs 5 месяцев назад
Yea I didn’t film to completion. Ended up running that thing thru 3 defrosts to clear the interior while I went and did the roof work scheduled. Thanks for looking out for me 😊👍🏼
@shine-cg9uf
@shine-cg9uf 5 месяцев назад
❄️💪🇺🇸👍 nice troubleshooting
@harrydickson4575
@harrydickson4575 5 месяцев назад
👍👍👍
Далее
Continental drawer freezer - Not freezing
6:58
Electro Freeze soft serve - It’s ALL broken
27:40
Просмотров 2,5 тыс.
How To Clean Your Air Conditioner Condenser
13:09
Просмотров 2,3 млн
Hoshizaki Icemaker - new unit
5:55
Просмотров 735
Freezer - callback?!?
9:11
Просмотров 1,4 тыс.