Тёмный

Couple Of My Calls From Today!  

HVAC GUY
Подписаться 67 тыс.
Просмотров 15 тыс.
50% 1

In this video I have an easy call, then I go to a carrier min-split! #hvacguy #hvaclife #hvactrainingvideos #airconditioner #hvac #hvactechnician #hvacinstall #furnace #heatpump #hvactroubleshooting #minisplit #carrier #skilledtrades #bluecollarpride
Merch Store : hvac-guy-2.cre...
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Makita Wet/Dry Vac: amzn.to/3VVHpsz
Veto OT-LC: amzn.to/3wSK1Nj
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

5 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 70   
@derek10w
@derek10w 5 месяцев назад
Capacitor calls are the best 😁
@brianclark803
@brianclark803 5 месяцев назад
Very safe using a screwdriver to short out capacitor😅
@jthonn
@jthonn 5 месяцев назад
Mini splits, I'm trying to like them. They are great when they're working. Thanks for taking us along.
@unmountablebootvolume
@unmountablebootvolume 5 месяцев назад
And the biggest P.I.T.A. when they are not.
@kens.3729
@kens.3729 5 месяцев назад
Had an Issue with a Sequencer today in an Electric Furnace. Furnace kept Running and Running and I quickly determined it was Not the Thermostat. 🤔👍
@dontarguewithfools
@dontarguewithfools 5 месяцев назад
My humble opinion Most mini split issues are an issue with Freon. Usually from a bad install. Either careless or inexperienced at flaring the copper and or tightening the nut
@stevetanner525
@stevetanner525 5 месяцев назад
Agreed. Some of them come with pre-flared linesets, and usually they're gouged or deformed so I always redo them. Had one the other day where the flare nut cracked at ~8 ft-lb (1/4", was supposed to be 11.8). I'd just had the digital torque wrench recalibrated, never seen a flare nut crack like that. Crappy pot metal that looks like brass but certainly isn't up to spec. Replaced with a USA-made nut and it tightened right up to spec, no leaks.
@acrservicesmathewr7565
@acrservicesmathewr7565 5 месяцев назад
P6 is a code for low pressure. Happens all the time
@maxwellsmart3156
@maxwellsmart3156 5 месяцев назад
I've noticed the use of pine needles a weed block where you are. In Canada I've never seen anyone do that, it usually bark mulch, but the needles seems like the obviously better material. I'm going to give it a try as my pine tree is a never ending supply. Loving the videos.
@HVACGUY
@HVACGUY 5 месяцев назад
Pine needles or Douglas Fir needles ? Big difference down here
@bw1841
@bw1841 5 месяцев назад
I don't know where to tell you to look, but I thought I read some comments of people saying a big fluffy pile of pine straw for mulch can catch fire, right next to your house, and therefore some local governments don't allow it for house side mulch. You might want to research that. I think it was on one of this Hvac Guy's videos, he was working on a unit where there had been a fire.
@ThomasWalker-m2y
@ThomasWalker-m2y 5 месяцев назад
Wow people do clean their house in Georgia, SIMPLY AMAZING
@kens.3729
@kens.3729 5 месяцев назад
Shocking! 😬👍
@hinspect
@hinspect 5 месяцев назад
Couldn't resist a joke from the 60s: I smelled mothballs 🤨 How did you get the little legs apart? 😅
@Menik559
@Menik559 5 месяцев назад
😂 Imagine that
@woodystokes1543
@woodystokes1543 5 месяцев назад
Your a glutton for punishment with the duct less 😅nice job 😊
@DevinHVACInc
@DevinHVACInc 5 месяцев назад
I ran into that same sys last winter with p6 code. It was freon issue. Remove and charge by weight. Been good since. It was over charged
@franciscotejeda1461
@franciscotejeda1461 5 месяцев назад
Excelent video Mr Curtis n have a good day
@unclefester4822
@unclefester4822 5 месяцев назад
Someone probably put moth balls in their unit to keep the mice from chewing the wires.
@braxtonboysmaintenance2644
@braxtonboysmaintenance2644 5 месяцев назад
Snake away too
@robalexander7348
@robalexander7348 5 месяцев назад
Thanks Curtis, a few Mini Split faults would be a change to view 👍 Au
@kg4muc
@kg4muc 5 месяцев назад
Good thing on the mini splits is there’s only a couple of manufacturers but a gazillion different versions and very little documentation that’s easy to locate. Wish Bluon would add more to their database. Watch that dang wasp 🐝 they are very sneaky and will come atcha outta nowhere to pop you. Being allergic to em makes me hate and scared all at once 😮
@JesseDoesHVAC
@JesseDoesHVAC 5 месяцев назад
If you are smelling moth balls near the condensers, someone has been suffering lizards on the units. I had a pest controller specialist give me that inside tip when dealing with areas where lizards are a problem. Apparently mothballs is the cure! Ive tried it and never had any repeat issues of the little critters frying themselves on the boards
@brushben22
@brushben22 5 месяцев назад
Brostash!! Great stuff We have 3 LG Ductless Mini Splits here. I believe it’s compressor module protection
@stevencossaboon3237
@stevencossaboon3237 5 месяцев назад
Nice work on both jobs Curtis. The second job you need to run from. Mini splits suck.
@harrydickson4575
@harrydickson4575 5 месяцев назад
👍👍👍
@kaptainkush7864
@kaptainkush7864 5 месяцев назад
Worked on a 1994 icp package unit today. Damn thing was older than me
@iamnoone.
@iamnoone. 5 месяцев назад
Mini split has mini problems 😂😅
@joshr2828
@joshr2828 5 месяцев назад
I have one like this about 4 months ago. Ended up having to replace compressor and VFD
@Moistyr1
@Moistyr1 5 месяцев назад
Found a blown up hard start today lol
@zeldamoore8371
@zeldamoore8371 5 месяцев назад
My son completely destroyed his shoulder trying to get away from wasps in AC unit. He fell into something & had hours of surgery to try & repair but still not right.
@NicolasMuniz-n8g
@NicolasMuniz-n8g 5 месяцев назад
If it is rebranded from Midea to Carrier price probably tripled or more.
@markchapman4197
@markchapman4197 5 месяцев назад
One of the reasons I retired, units like this
@yrs94
@yrs94 5 месяцев назад
The big question is what do you charge, Curtis, for a capacitor
@ronchambers9762
@ronchambers9762 5 месяцев назад
My very humble opinion. The residential customers are getting beat over the head with mini splits. They have tripled the cost of heating and cooling your house with almost no added benefit. Love your channel Curtus
@Jbasto97
@Jbasto97 5 месяцев назад
Mini splits should always have a surge protector Best practice
@mikemoseley8711
@mikemoseley8711 5 месяцев назад
That multi head unit is very loud
@tedhicks5431
@tedhicks5431 5 месяцев назад
Nothing good bout those mini splits when they start failing 😅
@davids8133
@davids8133 5 месяцев назад
Question??? I thought you said you heard refrigerant flowing when you initially checked the inside. How was it flowing if the compressor wasn't working due to the capacitor?
@HVACGUY
@HVACGUY 5 месяцев назад
I thought I did too. But, there’s another line set in that closet, maybe that’s what I heard
@davids8133
@davids8133 5 месяцев назад
@@HVACGUY That makes sense. Thanks for your reply.
@geraldleffew7008
@geraldleffew7008 3 месяца назад
Possibly Faulty indoor coil thermistor High or low-pressure switch issues Inverter module protection DC bus voltage issues MCE error Zero speed protection Phase sequence error Excessive compressor frequency variation
@beardedbeast1659
@beardedbeast1659 5 месяцев назад
What magnet do you have on your meter?
@HVACGUY
@HVACGUY 5 месяцев назад
Comes with the meter
@quintoncross2069
@quintoncross2069 5 месяцев назад
It use to be carrier toshiba but I think midea makes theme for carier now
@brianclark803
@brianclark803 5 месяцев назад
Sad thing is he really doesn't know mini splits definitely needs to go to a few classes on them.
@OnusBones
@OnusBones 5 месяцев назад
Frustrating. It seems to me that AC should be a lot simpler. Oh well.
@carlossaenz4075
@carlossaenz4075 5 месяцев назад
Really like the magnets on ur meter can u please let know where to buy it for my meter . Brand, Model. Please
@bobwelker8013
@bobwelker8013 3 месяца назад
Why not use a magnetic strip or magnetic bowl to keep you screws in?
@woodyshvacr
@woodyshvacr 3 месяца назад
Shouldn't pressing the contactor in discharge the dual capacitors you keep stick a screw driver into???
@Garth2011
@Garth2011 5 месяцев назад
Either or both the condenser fan(s) or compressor don't sound normal with that ticking sound as the system ramps up and down. What is the other condensing unit there for?
@carlossaenz4075
@carlossaenz4075 5 месяцев назад
Could u tell what type , make , model of meter magnet on ur meter is !!!!! Please
@christiansmith2855
@christiansmith2855 4 месяца назад
I'm trying to figure out why the first thing you didn't do after getting the one system back up and running is check your running amperages of your compressor. The second thing is how are you going to test freon without making sure that your components are clean. You didn't check anything inside. You know for a fact that can answer coil is dirty. Therefore, your pressures are not correct and how are you checking superheat or sub cool when you didn't put not one temperature probe on nothing,... And 160 suction pressure is hardly ever okay. Just saying
@anthonyyoung7344
@anthonyyoung7344 5 месяцев назад
That mini split is a Madea
@roqueherrera8471
@roqueherrera8471 5 месяцев назад
DUUUUDE missed a screw
@sergiohernandez4163
@sergiohernandez4163 5 месяцев назад
They sure dont make easy to work on them mini splits. I hate the ones that have the boards up side down.
@jamierushing
@jamierushing 5 месяцев назад
Hi bro
@HVACGUY
@HVACGUY 5 месяцев назад
What's up?
@mplewis5388
@mplewis5388 5 месяцев назад
Curtis, I finally got the first comment!!!! Wooo
@HVACGUY
@HVACGUY 5 месяцев назад
Woohoo
@mplewis5388
@mplewis5388 5 месяцев назад
I think you are right with the multiple problem idea. Good work on that one buddy.
@stevea6722
@stevea6722 5 месяцев назад
"Made in China" well there's your problem lady!
@geraldleffew7008
@geraldleffew7008 3 месяца назад
Low pressure fault
@unmountablebootvolume
@unmountablebootvolume 5 месяцев назад
The difference between the first and second call is quite striking. First call: No beeping smoke detector, barking dogs, rat crap or piles of trash, everything is labeled correctly, clean, normal equipment, even smelled of moth balls and not of trash! And then there's that second call... Shitty mini split, even more frustrating than usual, Shock hazard, cryptic error code, mucky outdoor unit, annoying video ad, couldn't find the problem, and worst of all: WASPS!!! Could be worse (rats, trash, barking dog, actually getting zapped, sewage), but also far better.
@AustinTaylor-b1o
@AustinTaylor-b1o 5 месяцев назад
That would still be better than a mini split. :D
@w5cdt
@w5cdt 4 месяца назад
Mothballs….to keep cats from doing their business there.
@crg061
@crg061 5 месяцев назад
Mini split sounds horrible
@chrissipple1018
@chrissipple1018 5 месяцев назад
Bluon refrigerant is crap and so is their website and manuals. Waste of time
@BPassalaqua
@BPassalaqua 5 месяцев назад
Don't like new systems too many brains for me you fry brains out trying to figure what wrong
Далее
Women’s Celebrations + Men’s 😮‍💨
00:20
OIL FURNACE AND AC SYSTEM UPGRADE
20:17
Просмотров 7 тыс.
Condenser change out
30:08
Просмотров 2,3 тыс.
HVAC No Cooling Service Call WORST HELICOPTER EVER !!
22:15