Тёмный

CT Clamp Extention 

Mikes DIY Tesla Powerwall
Подписаться 6 тыс.
Просмотров 5 тыс.
50% 1

Mikes DIY Powerwall Update 17 - CT Clamp Extention to my Inverter

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 19   
@swolath
@swolath 8 лет назад
check the resistance with and with out the extension?
@dennisolsson3119
@dennisolsson3119 8 лет назад
Try running it along the route more or less as you intend later on for a test run. When you stretch out the cable you turn it into a long antenna. It may or may not become an issue. Also shielding the cable may help, or using an old coax cable (TV antenna cable, or audio cable, for the cheap version). I'm not really sure though, since the "twistiness" of the TP cable should counteract noise (all increased voltage on the brown at a point in the cable should also be added to the brown/white, so the differential between the two should stay the same).
@MikesDIYTeslaPowerwall
@MikesDIYTeslaPowerwall 8 лет назад
Good point i will lay it out and see if that makes a diff :) It should do
@lm8012
@lm8012 8 лет назад
Working in IT you might have access to shielded network cable, that will help with noise. connect only one end of the shield to battery negative. some single pair phone cable is also shielded. a long cable would lean more towards a lower frequency antenna, and it is dealing with 50Hz mains so could pick up mains hum from power lines in the area, hopefully they are not parallel with you CT clamp cable. you could try a capacitor say a few picofarad across the end closest to the inverter. Just ideas and its working quite well as it is so might not be worth it.
@Yahgiggle
@Yahgiggle 7 лет назад
in the handbook it says you can have the clamp upto 30m away. i just used some thin speaker wire that was 30m, its working sweet as, but what i want to know is how do you run 2 or more units at the same time all set to limit oO do i have to run 2x the cable or could i just splice the cable i have and have one clamp feeding all inverters
@SolarEngineering
@SolarEngineering 3 года назад
do you still use this inverter?
@marganai
@marganai 7 лет назад
Hello, can you tell where to buy the extension cable, online store? Thank you.
@mark_osborne
@mark_osborne 7 лет назад
This is fantastic !... saves the cost of buying the divorced Limiter box
@adil2016
@adil2016 3 года назад
Hi , great video , thank you . do you have link or list for those parts you used ? and is there a way to connect two sensors instead of one ? in the usa we have two wires each has 120v , so boh need to be monitored and each need a ct clamp . ? thank you
@oinkbastudios3150
@oinkbastudios3150 6 лет назад
Is it possible to have 2 of these inverters running.. example: one for a pool pump (ct clamp on pump braker) and the other on the house main box? Is that doable? (Pity you can't adjust in menu for the cable length gain).
@beardedprepper8606
@beardedprepper8606 6 лет назад
Yes you can. Check out oldtimeengineer he has two running on his with one ct clamp on one leg and the other ct clamp on the other leg.
@johnseth-watkins6036
@johnseth-watkins6036 8 лет назад
Isn't the residual 10W the amount the inverter is drawing?
@mark_osborne
@mark_osborne 7 лет назад
By chance, would you know the inside diameter of the sensor clamp ? I've looked high and low on-line and even asked the question to an ebay seller - without results--- (I've heard they are celebrating the Chinese New Year) I want to be sure it will go around my incoming wires from the meter (which are huge)
@MikesDIYTeslaPowerwall
@MikesDIYTeslaPowerwall 7 лет назад
around 12mm , they use the 100a 50mA Blue CT clamp
@MikesDIYTeslaPowerwall
@MikesDIYTeslaPowerwall 7 лет назад
Very ture but i ended up buying it anyways as my CT cable was 20m and i was getting about 90% rather than say 100% if i had a short CT cable. Eg if the house load was 200watts the grid-tie with limter and 20m CT cable read it as 150watts ish so the 50w came from the grid, depending on the house load eg the fridge it would be out by more. However at higher loads it was better just the very low loads it couldnt read well. I will be doing a video of the External unit soon so stay turned :)
@MikesDIYTeslaPowerwall
@MikesDIYTeslaPowerwall 7 лет назад
Very ture but i ended up buying it anyways as my CT cable was 20m and i was getting about 90% rather than say 100% if i had a short CT cable. Eg if the house load was 200watts the grid-tie with limter and 20m CT cable read it as 150watts ish so the 50w came from the grid, depending on the house load eg the fridge it would be out by more. However at higher loads it was better just the very low loads it couldnt read well. I will be doing a video of the External unit soon so stay turned :)
@hacky2008
@hacky2008 8 лет назад
try using a ferrite coil to limit your noise
@d212611
@d212611 6 лет назад
Does the CT clamp have install orientation on the cable?
@MikesDIYTeslaPowerwall
@MikesDIYTeslaPowerwall 6 лет назад
Its on the clamp. The clamp needs to be the right way around. If its not turn it around when testing
Далее
Teeth gadget every dentist should have 😬
00:20
Просмотров 1,3 млн
It works! Limiter problem sorted
15:26
Просмотров 6 тыс.
Inverter Problem Part 3
12:39
Просмотров 3,6 тыс.
Inverter Problem Part 4
17:16
Просмотров 6 тыс.
Grid Tie Inverter External Limiter Install
15:17
Просмотров 37 тыс.
Final MPT-7210A Install and Problems.
12:08
Просмотров 25 тыс.