Тёмный

2kW Grid Tie inverter with 2 CT sensors. Part 3 of 3. For US split-phase system. 

SolarEngineering
Подписаться 21 тыс.
Просмотров 32 тыс.
50% 1

Important update about cable: • Updating CT cable for ...
Part 1: • 2kW Grid Tie inverter ...
Part 2: • 2kW Grid Tie inverter ...
Connecting 2 inverters together: • Connecting 2 2kW grid ...
Emporia energy monitor review: • Installing house elect...
Emporia energy monitor: amzn.to/2SKKREE
CT sensors: amzn.to/35M85QR
Inverter Amazon link: amzn.to/351gWOb
Inverter Ebay link: rover.ebay.com/rover/1/711-53...
As an Amazon Associate I earn from qualifying purchases.
As an Ebay Associate I earn from qualifying purchases.

Опубликовано:

 

4 май 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 194   
@Ulbre
@Ulbre 11 дней назад
I wouldn't have thought that this would work given that the two phases are out of phase with each other. But hey, it worked so well done :) :) :) I will try this on my three phase 230v.
@jimginnyohio
@jimginnyohio 4 года назад
Awesome! Thanks for sharing. Looking forward to seeing more of your videos. I would like to see more about your battery bank.
@SolarEngineering
@SolarEngineering 4 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ic_Ulh8DOlk.html
@learningpower9437
@learningpower9437 4 года назад
Excellent. You showed me that I can extend perhaps the clamp cable... several feet ...since my battery bank and the breaker panel are about 30 ft apart. Since the output is current...maybe it will have little effect at the inverter input. Therefore, I don't need to buy the extender limiter. I read somewhere .that if you have the clamp connected at the panel ..you better have at least a resistor to dissipate the current at the end or have it already connected to the inverter. Good Job!!!
@michaelo85
@michaelo85 Год назад
Did you try 30ft cable, trying to find the max length I can use.
@dr.projectx5142
@dr.projectx5142 3 года назад
This is good especially the limiting factor of ba k feeding to the grid.
@dainthamos4712
@dainthamos4712 3 года назад
I would like to see like a seperate leg test for each side
@benkanobe7500
@benkanobe7500 3 года назад
I really appreciate this effort. And, your hard work to master the English language. I have a sincere input: Maybe find an automated translator you could feed your audio through to make it easier for North Americans to understand. You did a great job on this and translated very useful information. Thank you.
@SolarEngineering
@SolarEngineering 3 года назад
thanks for feedback Ben, I'll see if I can find something..
@petersun21
@petersun21 3 года назад
I have 0 problem understanding him
@benkanobe7500
@benkanobe7500 2 года назад
After listening to several of your RU-vids, I was able to get use to your voice and can understand you with zero problems as xiaoqing has also stated below. So, I just needed to adjust my ear, you don't need to change anything.
@MIKE-il6mu
@MIKE-il6mu 3 года назад
Thanks for your time and effort. Great video with practical information. Do you know if this set up will work with the 1000 w version for 240vac?.
@SolarEngineering
@SolarEngineering 3 года назад
yes, same idea for 1kW version. thanks for feedback, appreciate it.
@JD_Manufacturing
@JD_Manufacturing 3 года назад
Great Information. Well Done. I am considering buying a 1.5kw system with this grid tie inverter. my meter has a round dial and looks like an older model. Pretty sure I don't need to do this hack. But great that you figured it out. Helping the common man is a great thing you have done here. Is there a way to send the power to your battery automatically instead of it going to the grid?
@SolarEngineering
@SolarEngineering 3 года назад
You are lucky with this meter, you could just push energy to the grid and the meter will rotate backward. I can disconnect inverters manually (just one switch) to direct energy to the battery. Thanks for the kind feedback.
@theproperfix
@theproperfix Год назад
sure buy a charge controller you need to figure out what voltage setup you have first though e. 24v or 48v
@jasonsteeg1311
@jasonsteeg1311 3 года назад
Thank you for the video. Does the inverter calculate wattage based on voltage from the sensors? I'm just curios as to why you connected them in series and not parallel, I thought these sensors measure the current.
@SolarEngineering
@SolarEngineering 3 года назад
here is the update: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-PcIfI7jypB4.html now sensors connected in parallel
@adil2016
@adil2016 3 года назад
very good video . thank you for sharing . do you have a video showing how you have the output from the inverter to your home grid is connected , is the AC cable connected directly to an outlet or main panel ?
@SolarEngineering
@SolarEngineering 3 года назад
thanks for feedback, here is update: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-PcIfI7jypB4.html
@earthenergyhex
@earthenergyhex Год назад
Thanks!
@renatoziva
@renatoziva Год назад
The video is very good, I just didn't quite understand the reason for installing the two sensors and which network cables they are connected to, I'm watching the video with a translator, so there is a little doubt, if you answer I'm very grateful, thank you .
@SolarEngineering
@SolarEngineering Год назад
I need 2 CT sensors because I'm located in US and we have split-phase electrical system (2 hot wires, 1 neutral). In Europe it's usually one phase (hot) and one neutral, in this case only 1 CT sensor is needed.
@user-xx4qk5sd4p
@user-xx4qk5sd4p Год назад
ok perfect what a genius are you one question then go from the energy meter I have current 220v to 110 But then I will connect the ct to ground or negative phase or positive phase in which sir?
@hansdampf3011
@hansdampf3011 3 года назад
Great video !!! One question. What is the maximum input current for the limiter input? Do you have a data sheet? Could it be that you destroy you input if the input current goes higher than 50mA. I think the current of both sensors is added together so there is the danger that in the worst case the input current is higher than the allowed input current.
@SolarEngineering
@SolarEngineering 3 года назад
I'm not sure what are requirements, so far it works well with two clamps.
@hansdampf3011
@hansdampf3011 3 года назад
@@SolarEngineering Maybe you never exceeded the 50mA. But if you have 100A on both phases I think the current would be 100mA. But maybe the current is limited inside the inverter. Do you know at what limiter current the inverter produces the maximum power of 2000W. Would it be possible that you can measure this value?
@thedavesofourlives1
@thedavesofourlives1 8 месяцев назад
one would assume putting them in series would double the voltage but not the amps.@@hansdampf3011
@jesseflory9910
@jesseflory9910 4 года назад
Should there be any issue with using two of these 2000 watt inverters? Keep the great videos coming!
@SolarEngineering
@SolarEngineering 4 года назад
Theoretically shouldn't be. I'm planning to install 2nd inverter in future.
@woodzyfox4735
@woodzyfox4735 3 года назад
Ihave one of these they should be able to add more. i think you need the remote addon so they can talk to each other to prevent issues. ill add more to my 80V 1900W solar setup later in life. Suggest doing a 48V 100AH+ battery for night time use
@thedabbler2753
@thedabbler2753 3 года назад
Hello! Do you think this inverter can work with 4 x 255W panels and no batteries? The panels are too big for the 1k inverter (VOC 38.7, VMP 30.6, 8.32A), so I think the 2k gives good room for expansion. The only configuration I can think of is two strings of 2, joined in parallel so 77.4V, 61.2V and 16.64A. It should be okay for the 45V-90V input but there is no DC amp input listed. Will 17.7A be okay? Do you think the dryer plug or direct into a two pole breaker is better, and for safety do you think the inverter should have DC and AC protection e.g breakers and shut off switches either side? Sorry for so many questions.
@SolarEngineering
@SolarEngineering 3 года назад
Hi there, 1. 77.4V, 61.2V and 17.7A > yes it will work, inverter will pull as many amps as it needs in range of 0-17.7AA 2. two pole breaker is better > yes, separate 240V line with it's own breaker for inverter is better. 3.inverter should have DC and AC protection e.g breakers > 1 dc breaker, 1 ac double breaker should be fine Let me know if you have any other questions.
@thedavesofourlives1
@thedavesofourlives1 7 месяцев назад
what about running each split phase leg through the one sensor, one in the opposite direction?
@user-yn6md3uw8u
@user-yn6md3uw8u Год назад
你好,請問這個2個CT傳感器的型號是?
@andys5203
@andys5203 2 года назад
Great video as always. My panel is located in the exterior of my house. My set is in my garage which is 50ft away. Do you think the CT clamps will be able to ready line 1&2 because of the distance ? Thanks
@SolarEngineering
@SolarEngineering 2 года назад
it should work, I know that on ebay you could by CT sensors wire 100ft, so 50ft shouldn't be a problem.
@andys5203
@andys5203 2 года назад
@@SolarEngineering Thank you sir!!
@user-xx4qk5sd4p
@user-xx4qk5sd4p Год назад
refers to the sensor where it should be connected It has to be connector after the electrical box or where
@edlum1861
@edlum1861 3 года назад
How is the inverter holding up? Did you reduce the output to extend the life of the inverter?
@SolarEngineering
@SolarEngineering 3 года назад
it works. Set 1.2kW max till I have small array.
@kellyvb9881
@kellyvb9881 3 года назад
THANKS so much for your response. Not sure how to read the display and what its telling me. These were some of the readings I'm getting. I have 6 300 watt panels. 521.1w (solar) 1600 w (Small # under 240 volt) 1064.4w (solar) 1597 w (Small # under 240 volt) 1192.5w (solar) 1594 w (Small # under 240 volt) 1324.8w (solar)1602w (Small # under 240 volt) Does it look like I have this setup correctly?
@SolarEngineering
@SolarEngineering 3 года назад
check this video: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-UrHD9OLmJtE.html let me know if you have questions after
@woodzyfox4735
@woodzyfox4735 3 года назад
What batterys did u use? I got 8 12V 35AH deep cycle seal Lead acid ones for a 48V system. (on a tight budget).
@SolarEngineering
@SolarEngineering 3 года назад
I'm using LiFePo4, 48V 450 Ah. the last video on the channel is a full system overview.
@czarrevs3616
@czarrevs3616 3 года назад
Great Video! Can this be done with the 1000W grid tie inverter? I'm going to try to set up the 1000W inverter here in Los Angeles...hopefully the power company doesn't come knocking on my door.
@SolarEngineering
@SolarEngineering 3 года назад
1kW going to be even easier. you'll just need to install 1CT sensor that coming with inverter. Just make sure you are connecting inverter to correct leg (inverter should be plugged to outlet that is powered from Leg that monitored by CT sensor).
@czarrevs3616
@czarrevs3616 3 года назад
@@SolarEngineering My electrical panel has 2 legs. Wouldn't that cause an imbalance and send power back to the grid?
@SolarEngineering
@SolarEngineering 3 года назад
@@czarrevs3616 1kW inverter works with 120V, so if you install sensor on correct leg it will not cause backfeed. If you want to have 0 grid usage, then you will need 2x 1kW inverters (one for every leg). Or 2kW version(like in this video) - 2kW using 2 legs so you could do 0W grid consumption with just 1 inverter.
@lawnracer1
@lawnracer1 3 года назад
Wondering if the 2kW inverter has the option to use it on a single leg (120V) and use a smaller battery bank (36V) I know it says DC input of minimum 45V but didn't know if it was possible if only using it for a smaller load. I know I can buy the 1kW version and it will do this fine, but I would like to leave room to build onto my battery bank. Love the videos, you have a lot of great information. One of the other things I was wondering on these units, can you have them put them on schedule? I have great off peak pricing and am looking for a way to use it to my advantage.
@SolarEngineering
@SolarEngineering 3 года назад
2kW model will work only in the range 45V - 90V (I think the starting voltage about 47 or 48V). It will not work for 120V, you'll need to buy 1kW model.. You could add a schedule option by adding a timer either on AC or DC side.
@lawnracer1
@lawnracer1 3 года назад
@@SolarEngineering Thanks for the reply! Guess I will have to series a couple of those batteries I want to set up. Looking forward to more content from you!
@thedavesofourlives1
@thedavesofourlives1 8 месяцев назад
I can confirm it does not work with 120v only.
@lauramarsotomayor3668
@lauramarsotomayor3668 4 года назад
What is the best configuration if I already bought two 1000 W with limiters, my setup is one for each leg.
@SolarEngineering
@SolarEngineering 4 года назад
you'll need to find 2 outlets that on different legs. then install CT sensor on correct leg and plug you inverter: INV #1 on LEG1 and clamp on LEG1 INV #2 on LEG2 and clamp on LEG2
@quimbarrera
@quimbarrera 4 года назад
Hi, I am about to buy the same inverter, but I have to place it far away from the electric panel. I was thinking about running a long 2-wire cable to extend the sensor original cable. Do you know how long the sensor cable could be without affecting the data readings?
@SolarEngineering
@SolarEngineering 4 года назад
I don't know max wire length, but you always could connect additional CT sensor in parallel, it will make signal stronger.
@lilanhtu
@lilanhtu 3 года назад
I try install mine today go to the back yard kinna long too it work, but i saw my miter go backwards very slow and the number stay the same if no big load, so i don’t know if that is normal.
@cliffBMRC
@cliffBMRC Год назад
My SUN-2000W GTIL2 will not save settings after correct operations. Any ideas as to how to factory reset, or correct the problem. THANK YOU. Cliff
@brandonoh777
@brandonoh777 3 года назад
You wouldn't happen to know the specifications on the Emporia energy Vue Gen 2 CT censors would you... I'm pretty sure I have the same unit you do there's the 2 100 amp main CT centers and then there are smaller 50 amp ct's for circuits but none of the CT sensors have specifications on them... I'm kind of wondering if the burden resistor is located in the CT sensor or in the actual vue box itself?
@SolarEngineering
@SolarEngineering 3 года назад
sorry, I don't know..
@brandonoh777
@brandonoh777 3 года назад
@@SolarEngineering is there a way to measure some of those values w/o dismantling the CT sensor that you know of?
@benkanobe7500
@benkanobe7500 2 года назад
At 7:50 it appears you have set up your GTI as if it were connected to Solar Panels and not battery. In this mode it will use MPPT, if you use either of the other selectable limit modes and input a setting, it is my understanding from Mars Rock that MPPT is then disabled. I need help understanding how you set up the Menu for using batteries and a what I think is a stand alone MPPT Charge Controller (Outback/Midnite). Thank you as I know I ask/asked lots of questions and you have moved way beyond these little GTIs and are using SolArk now. The chart for my house looks similar. My base consumption is 230Watts so that is what I get from around 10PM until around 8:00AM when sun hits my panels. After 8:00AM until 6:00PM my meter reads between 0.000KW and 0.032Watts all day long. I want to have my batteries run at night and need to understand how you set up the GTIL Menu to run batteries at night and Solar during the day. Thank you! Mine works perfect during the day and I don't need to adjust anything (I have an excellent property for solar so my ground based panels are setup for "sunrise", "mid day", and "sunset").
@SolarEngineering
@SolarEngineering 2 года назад
I didn't find solution to use batteries just at night without complex solutions
@SolarEngineering
@SolarEngineering 2 года назад
And that's one of the reasons I moved to SolArk
@jeffwelch2934
@jeffwelch2934 2 года назад
After 6 mnths mine has "grid error" message and no output. Company not helpful. Do you have a site or number for help? Thanks for the excellent video and for responding/helping people.....
@SolarEngineering
@SolarEngineering 2 года назад
unfortunately I don't know where to repair it. May be try FB groups: "Solar Grid Tie Inverter with Limiter USA Users" and "SunG Grid Tie Inverter with Limiter"
@martinhilburger2971
@martinhilburger2971 3 года назад
Hello, I want to compensate 3 Phase(Legs) Grid here in germany with 1 inverter. Are this working with 3 CT senors parallel or serial?
@SolarEngineering
@SolarEngineering 3 года назад
I haven't try it
@petersun21
@petersun21 3 года назад
I have 14 battery modules. Each one has 12 lithium ion battery cells. The nominal voltage for each module is 3.7 * 12 = 44.4 , the charging voltage is 50.4v. The low discharging protection voltage is 36v. I want to charge the battery in the night and use the battery during the day for time-of-day purpose. I like what I am seeing here. If I use a limiter so I would like to have 2000w model which does not support input voltage as low as 36v. Is there a setting to adjust the input voltage? Thanks.
@SolarEngineering
@SolarEngineering 3 года назад
unfortunately, the minimum voltage cannot be adjusted. I think you have 2 options: 1. connect batteries in series to make 24cells battery, and charge cells up to 3.75V per cell to get 90V (not ideal, since you are going to lose some capacity) 2. buy few 1kw version inverters.
@joseantonioescobedo1897
@joseantonioescobedo1897 3 года назад
A question please: Can I use these clamps via wifi with a transceiver?. Thank,s.
@SolarEngineering
@SolarEngineering 3 года назад
I haven't heard about WiFi clamps..
@kellyvb9881
@kellyvb9881 3 года назад
I just installed this unit (2000 watt model) It looks like you have both sensors arrows are pointing to the right. shouldn't 1 point left???
@SolarEngineering
@SolarEngineering 3 года назад
correct, one sensor needs to be reversed.
@mtyetiman
@mtyetiman 3 года назад
so for a 240v us system wire the sensor in parallel or in series.
@SolarEngineering
@SolarEngineering 3 года назад
here is latest update: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-PcIfI7jypB4.html works excellent.
@user-xx4qk5sd4p
@user-xx4qk5sd4p Год назад
the consumption was more expensive for me rather! that I have badly connected do you know where the ct sensor goes I have 220 in the neutral, ground or positive phase? I have this model SUN 1000W Solar Grid Tie Inverter with Limiter Sensor Wi-Fi DC 22-65V 45-90V AC
@vegasromaniac
@vegasromaniac 3 года назад
So you got a 240v inverter connected to the dryer connector? Hmmm that is interesting...
@SolarEngineering
@SolarEngineering 3 года назад
this video is from a long time back.. It's grid-tie inverters, even if someone pulls plug from outlet, the inverter will shut down immediately. here is latest setup: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-XpPdbo1LXEg.html
@capsoval
@capsoval Год назад
How has this inverter held up? Still functioning as it should?
@SolarEngineering
@SolarEngineering Год назад
I did use it for about a year without issues, but then upgraded to Solark inverter.
@carlosguzman4461
@carlosguzman4461 4 года назад
So If I get a 110v GTIL with one CT, I will be feeding only one leg and other leg will no be feed, and it will no backfeed... becuase is 110v and is only serving on hot from meter (provider) ---- to feed whole household... a GTIL on each leg... conected to a outled for the corresponging Hot wire.... ?
@SolarEngineering
@SolarEngineering 4 года назад
please watch 2nd part of this videos.
@jaeryu97
@jaeryu97 2 года назад
hello, would this work with 3 CT sensors? I have a 3 phase electrical system. Thanks
@SolarEngineering
@SolarEngineering 2 года назад
I don't think so, you'll need to use 2 or 3 inverters to make it work. for 3 inverters - each inverter will supply individual phase with it's own CT sensor.
@reneenietes
@reneenietes 4 года назад
What charges your batteries.do you have solar panels?
@SolarEngineering
@SolarEngineering 4 года назад
yes, 3 panels 260W each
@user-vm3mj1iw8m
@user-vm3mj1iw8m 9 месяцев назад
hello, if we have one phase, how we connect 2 limiter sensors ?on the same phase will work? i wait 2 grid tie inverters so i ask your help please
@thedavesofourlives1
@thedavesofourlives1 8 месяцев назад
If separate sensors don't work together on same phase, try using only 1 sensor with 2 units (parallel sensor wiring). in UK 1 phase.
@tuantrankim
@tuantrankim Год назад
what's the difference between 2 ct sensors clamp on 2 phases and 1 ct sensor clamp on 2 phases (2 lines at same time ) . Are they same ?
@mikesgarage394
@mikesgarage394 10 месяцев назад
1 clamp on 2 phases would cancel each other so you would omly see the difference between the phases.
@pedroalvarenga9210
@pedroalvarenga9210 3 года назад
Hello, if connect two-phase 220v, will I have an injection in both phases? Or only in the phase that has a current sensor.
@SolarEngineering
@SolarEngineering 3 года назад
In video I'm talking about US split phase. Are you sure you have 2 phase system? It's not used anymore..
@pedroalvarenga9210
@pedroalvarenga9210 3 года назад
Yes, here in Brazil we have 220v monophasic and 220v biphasic in some cities.
@SolarEngineering
@SolarEngineering 3 года назад
I'm not familiar with it. Could you describe what voltage you have in Brazil and how many wires coming to house? (like 1 hot wire, 1 neutral, 1 ground etc). I'll try to help.
@WReletricista-agoraoffgrid
@WReletricista-agoraoffgrid 2 года назад
bom dia aqui na minha região ( Brasil) a rede energia elétrica é bifásico 220 volts: fase+ fase: 220 volts e neutro e Terra. e em alguns estados é 127+ neutro e Terra e em outros estados é 220 + neutro e terra. porque você usou dois sensores, seria porque tem duas fases? comprei um desses de 1k mas ainda não instalação. abraços
@RJ-cc1fz
@RJ-cc1fz 4 года назад
Can u verify the amount of power u are using matches what your inverter screen says the grid is supplying? If u are backfeeding it will show as a positive reading on your electric company meter and u will be charged for it. Can u verify with your emporia monitor?
@SolarEngineering
@SolarEngineering 4 года назад
emporia stopped working at this time, because it sense power from L1 and L2 individually (L1 + neutral) (L2 + neutral). and inverter pushing power trough both legs. I know how to fix it, will shoot video later. need to buy additional sensor for emporia. but at this time looks like inverter pushing right amount of power (looking at electric company website 10:05)
@RJ-cc1fz
@RJ-cc1fz 4 года назад
Your electric company app will most likely show backfeed as power used so once u get your emporia configured to read your mains wires at 240v instead of 120v and 120v u will know for sure if cables are working correctly
@crazyjoecasino1066
@crazyjoecasino1066 3 года назад
Will this run without limiter. I have net metered and want power to run back to grid
@SolarEngineering
@SolarEngineering 3 года назад
yes, you could disable limiters in the menu, then inverters will produce full power.
@penrodautorepair3170
@penrodautorepair3170 4 года назад
What size wire is used in these wires.
@SolarEngineering
@SolarEngineering 4 года назад
white CT sensor that came with inverter: 20AWG blue CT sensors: 24AWG 48V to inverter: 8AWG 240V power cord: 14AWG
@luckywang95
@luckywang95 2 года назад
I have the same unit (SUN-GTIL2 2kW), but mine will shut it self off after running for few hours at around 600W outputs. The LCD turns black and I heard the AC plug has sparking sound. After turning everything off for a few minutes and turn on again, it will boots normally and start output power. However, I can see the temperature shown on the LCD is around 50C. May I know at what temperature will the fan turns on? From your video, I can hear your fan is spinning constantly (8:15) even at 400W. The fan on my unit doesnt spin at all... Initially i tot because of the low output, but now it seems like the unit is shutting down due to overheating...
@SolarEngineering
@SolarEngineering 2 года назад
I don't remember at what temp fans did initiate. But keep in mind that fans are the weak point there. It is possible that fans in your case failed and the inverter overheating... However it should start reducing it's output and display "overheat" message on the screen, it shouldn't restart. I'm not using these inverters anymore, so cannot check any details.
@luckywang95
@luckywang95 2 года назад
@@SolarEngineering there is no overtemp warning, or at least I don't see it coz it is off everytime I notice it. my unit is not rebooting itself but it is like killed its AC output (so no power to turn on the whole unit). I need to unplug the ac outlet, wait for a few minutes and plug it back on to get it working. If I don't unplug the AC, there is will occasionally sparking sound coming from the plug. It is like the unit tries to turn on but something wrong so it cuts the AC to protect it... Will add a fan to see whether it can solve the problem... Thanks!
@SolarEngineering
@SolarEngineering 2 года назад
@@luckywang95 It sounds like the fan is not going to solve the problem, I'd suggest to open inverter and check transistors for potential damage. May be it would be easier to replace damaged parts earlier.
@luckywang95
@luckywang95 2 года назад
@@SolarEngineering hmm. But the inverter is not completely faulty, it can still work, just occasionally it stops and need a "manual" reboot. I don't know how to troubleshoot this...
@darylw792
@darylw792 Год назад
@@luckywang95 Do you have the 2000W inverter?
@samfish6938
@samfish6938 2 месяца назад
will you do another video of grid tie and does it still work after 3 years
@SolarEngineering
@SolarEngineering 2 месяца назад
I sold my units after 1 year and moved to Sol-Ark
@samfish6938
@samfish6938 2 месяца назад
@@SolarEngineering can you power limit the solark
@pkefvkef4856
@pkefvkef4856 3 месяца назад
My dear friend.Can you be more specific for the efficiency of the 2kw sun grid tie inverter...If you want my experience offering him DC panel power 2000 watt it gives me no more than 1450 watt.so increasing the panel power to 2850 watt v=85 volt and I =35 ampere DC. THEN IT GAVE ME 1850 watt....so 1850/2850 = almost 66 % efficiency......i am really curious for yours measured efficiency......thank you .
@SolarEngineering
@SolarEngineering 3 месяца назад
sorry cannot answer this question, I used them for short period of time and switched to another brand
@smartines
@smartines 4 года назад
I have the same bug on starting the inverter, starts with 1450w. When set limiter and battery type I had constant 125w and no reaction on high grid consumption. How did you fix the inverter bugs?
@SolarEngineering
@SolarEngineering 4 года назад
in my case it works fine at the end of video. did you connect CT sensors correctly to L1 and L2 wires?
@smartines
@smartines 3 года назад
@@SolarEngineering I used the original limiter sensor that was in package with the 2000w grid inverter. In my case the inverter didnt measure the power.
@SolarEngineering
@SolarEngineering 3 года назад
@@smartines yeah, it will not work correctly with standard sensor. Look at Part2 video, I'm explaining why it's not working.
@smartines
@smartines 3 года назад
@@SolarEngineeringThanks for your hints, Im from EU we have 230V Standard here. I have now other gtil here. And it was working as it shoud. Then I tryed limiter Clap on one line and Gtil on other line. And now its not working right aswell as the first gtil. Is there a way to reset it completely? Iknow the select+up on Ac connect. This reset the Statistiks and the battery Mode. But I still have this error, gtil putts all energy to the grid and ignore the limiter sensor. 🗯After some hours reseting and trying I have it working again. Somehow I reverse the clap sensor resetet all options and Its working again.
@salvatoremaugeri1980
@salvatoremaugeri1980 Год назад
Ciao sono italiano mi potresti scrivere qui nel commento come collegare il limitatore di corrente e come collegarlo grazie mille
@NomadFella
@NomadFella 3 года назад
Can i use this inverter without connecting the limiter or it will not feed power into the grid at all?
@SolarEngineering
@SolarEngineering 3 года назад
yes, it can work without a limiter. Without a limiter, it will output full power to the grid, but you could limit MAX feeding power in settings.
@NomadFella
@NomadFella 3 года назад
@@SolarEngineering Thanks. Also, can i use this with a 3 phase wind turbine and using a bridge rectifier to feed DC power to the inverter?
@SolarEngineering
@SolarEngineering 3 года назад
@@NomadFella yes, since it's going to be just DC power, check the minimum voltage requirement for the inverter. Additionally, this kind of inverters has a model made for wind turbines.
@thedavesofourlives1
@thedavesofourlives1 8 месяцев назад
the wind version literally is the exact same with a 50a 3 phase bridge rectifier and studs built into the unit. (I own one). @@NomadFella
@kivasku
@kivasku 2 года назад
Is this set up still working for you? I see that the video was made in 2020 is why I'm asking.
@SolarEngineering
@SolarEngineering 2 года назад
I switched to another inverter. It worked well for 1+ years till I sold inverters and charge controller.
@earthenergyhex
@earthenergyhex Год назад
For the US 220V, what did you connect the ground to? You L1, L2 & N, where does ground go?
@SolarEngineering
@SolarEngineering Год назад
it's L1&L2 and ground, no neutral.
@protechnh
@protechnh 3 месяца назад
did you figure this out? Did use the neutral or the ground?
@earthenergyhex
@earthenergyhex 3 месяца назад
@@protechnh yes thx
@popeyeswetcactus
@popeyeswetcactus 3 месяца назад
@@earthenergyhexdid you use the neutral or ground? I’m currently using neutral….
@earthenergyhex
@earthenergyhex 3 месяца назад
@@popeyeswetcactus I used the neutral as well
@infernoal2994
@infernoal2994 4 года назад
With two ct clamp sensors in series to the limiter how does the inverter know to send for example 2 amps to L1 and 5 amps to L2?
@joshuabest100
@joshuabest100 3 года назад
It doesn't
@carlosguzman4461
@carlosguzman4461 4 года назад
Resistor at min 05:58 - what is the Ohm = 800 ?
@SolarEngineering
@SolarEngineering 4 года назад
it's 50 Ohm, using this resistor to pre-charge inverter. new video will be soon of entire system
@m20gerzy81
@m20gerzy81 3 года назад
Hello, does it work also on Solis on-grid 4G mini single phase inverter? Our utility is split phase 240v.
@SolarEngineering
@SolarEngineering 3 года назад
does it use the same CT sensors?
@m20gerzy81
@m20gerzy81 3 года назад
Yes, a Split core CT, CTSA-100A 100A/33.33mA.
@m20gerzy81
@m20gerzy81 3 года назад
Our supply is same in the US, 120v- Neutral-120v.
@SolarEngineering
@SolarEngineering 3 года назад
@@m20gerzy81 theoretically should work, I pushed new video with cable update: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-PcIfI7jypB4.html you could do this cable and test it as I showing in the video. I quickly googled Solis on-grid, looks like it's made for the US market, is it correct?
@m20gerzy81
@m20gerzy81 3 года назад
I think it start in australian and chinese market and pushed it to some asian countries (I'm from Philippines), europe and now in america...by the way, thanks to all your help and your very informative videos.
@juanpena5993
@juanpena5993 2 года назад
Can I use 120 volt
@SolarEngineering
@SolarEngineering 2 года назад
you can buy 120V version, then you'll need only one CT sensor.
@sakhumtang1
@sakhumtang1 4 года назад
Will this plug in 110v in your plug?
@SolarEngineering
@SolarEngineering 4 года назад
it goes to 240 outlet (7:02).
@SolarEngineering
@SolarEngineering 4 года назад
standard cable has 3 wires: hot (black), neutral (white), ground(green) so black and white wires should go to Leg1 and Leg2, ground wire to ground wire.
@thedabbler2753
@thedabbler2753 3 года назад
@@SolarEngineering how does it work for a newer dryer plug that has 4 wires?
@SolarEngineering
@SolarEngineering 3 года назад
@@thedabbler2753 3 wires plug: L1 L2 and ground 4 wires plug: L1 L2 neutral and ground For 4 wires plug you just do not use neutral.
@mikerussell5454
@mikerussell5454 3 года назад
Your Amazon link for the inverter has gone down. Any chance you can link to the model you use? I am guessing its a likely a lot cheaper to order from Aliexpress or something anyways.. So throw up a patreon link so I can send you some beer money.
@SolarEngineering
@SolarEngineering 3 года назад
yeah, Amazon kicked me off from affiliate program due to lack of subscribers. I've ordered 2nd inverter from this seller: www.ebay.com/itm/2000W-Grid-Tie-Inverter-with-Limiter-Sensor-MPPT-Stackable-DC45-90V-to-AC190-260/164298256289?ssPageName=STRK%3AMEBIDX%3AIT&_trksid=p2057872.m2749.l2649 They delivered from China to US in 7(!) days.
@dwey2557
@dwey2557 3 года назад
Hey can you send me the RU-vid video again about the limiter sensor
@SolarEngineering
@SolarEngineering 3 года назад
here is latest update: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-PcIfI7jypB4.html
@lilanhtu
@lilanhtu 3 года назад
I just got mine install today, the meter go backwards very super slow the number stay the same when no big load. Is this normal? Am i doing it right?
@SolarEngineering
@SolarEngineering 3 года назад
Do you have digital or analog meter? Analog - where you can see spinning physical wheel.
@lilanhtu
@lilanhtu 3 года назад
SolarEngineering it is digital it have 2 bars when i turn off inverter it will go from left to right, when inverter running when no big load that 2 bars stay and backwards very slow. Thank you.
@SolarEngineering
@SolarEngineering 3 года назад
@@lilanhtu I see, this smart meter. In place where I live, company will charge me for kW that I'm backfeeding into grid, so here is why I need to install limiters. Sounds like your system works, congrats.
@lilanhtu
@lilanhtu 3 года назад
Hi sir one more question. I run 6 panels of 275watts/60 cells, 2 in series = 62 volts. Most the time we use around 400watt so try to save the one from solar to battery to use at night. I have a lot lithium ion batteries (18650) i try to do 3s battery bank, so 4 of them in series will come out 50.4 volts but the charge controller i bought before is 30amp for 12/24 volt system. Do you know any charge controller that will work with my system? Thank you.
@SolarEngineering
@SolarEngineering 3 года назад
@@lilanhtu you could use MakeSkyBlue MPPT controller, I reviewed it recently. And going to do more detailed test soon.
@leamyelectricinc1
@leamyelectricinc1 Год назад
The inverter is design for 1 leg. USA has two legs combined at 240v. 120v per leg. The CT is design for 1 leg. If you split the CT's and run the inveter at 240vac split phase how does it know how to distribute an unbalanced load by doing this since there is only 1 input for the CT. If your fridge on leg 1 is drawing 200 watts at 120v and your washer on leg 2 is drawing 500 watts seems the inverter will put out 700 watts. Having that said. I assume each leg from the inverter is pushing back 350w per leg meaning. The fridge is getting 150 watts more witch goes back on the grid. The fridge is 150 watts short. As again seems to me you will be back feeding the grid with 150w. Can the inverter manipulate each leg vs each legs power draw. If not this idea is no good for USA split phase system. Seems the joining of the two CT's is adding up the watts for a 240v application. Again the concern is how it dustrbutes per leg. Thoughts?
@SolarEngineering
@SolarEngineering Год назад
you are right, inverter doesn't balance between legs. It works just because the meter doesn't measure consumption for leg1and leg2, only can measure total consumption for 2 legs together. So when we have load 1000w on L1 and 0w on L2, then inverter pushes 500W on each leg, but the inverter "sees" it as 0W consumption.
@carlosguzman4461
@carlosguzman4461 3 года назад
If L1 is requesting 100w and L2 Requesting 500w, does the Inverter will know which one needs what?
@SolarEngineering
@SolarEngineering 3 года назад
Inverter will send equal power to both legs 300w/300w. Smart meter measuring total W going in/out using only L1&L2 (meter not connected to neutral), so meter will see that total consumption as 0w.
@carlosguzman4461
@carlosguzman4461 3 года назад
@@SolarEngineering niceeee, thanks!!!!
@carlosguzman4461
@carlosguzman4461 3 года назад
@@SolarEngineering Waht tool u use to detect backfeeding ?
@SolarEngineering
@SolarEngineering 3 года назад
@@carlosguzman4461 I was just looking at smart meter, it shows negative amps when backfeeding.
@dainthamos4712
@dainthamos4712 3 года назад
How does the inverter know which leg the power is coming from
@SolarEngineering
@SolarEngineering 3 года назад
it doesn't, it will push energy back using 2 legs (equal amps to each leg I assume and smart meter will calculate total A coming to/from grid)
@dainthamos4712
@dainthamos4712 3 года назад
@@SolarEngineering The reason I ask is that in my country we have similar leg in our main breaker box but we only use 110v ac appliance that only require one leg of power
@SolarEngineering
@SolarEngineering 3 года назад
​@@dainthamos4712 to confirm: you have 2 legs coming to your electrical panel, 110V each. And all appliances using 110V, so loads for entire house distributed equally across 2 legs (or at least close to equal), is that correct? In total you have 4 wires in electrical panel: 2 Legs, 1 neutral, 1 ground?
@dainthamos4712
@dainthamos4712 3 года назад
@@SolarEngineering That is correct. But my load is not balance so if for example I am using 600watts on 1leg and 300 on second leg the inverter would produce 900watts equally which would equal to 450 watts on each leg which would mean that I would be over producing on leg 2 which the power company would charge me for
@dainthamos4712
@dainthamos4712 3 года назад
I am considering to have two 1000w inverters which give me mor control over each leg demand
@user-lv4jx3hk1q
@user-lv4jx3hk1q 9 месяцев назад
Prise koto
@kellyvb9881
@kellyvb9881 3 года назад
Your explanation is CONFUSING, How can your inverter supply ANYTHING at night with NO sun? Do you have batteries on it? You don't mention having batteries at all.
@kellyvb9881
@kellyvb9881 3 года назад
AND, I don't have batteries hence (Grid Tie) will this unit work without batteries?
@SolarEngineering
@SolarEngineering 3 года назад
@@kellyvb9881 yes, this inverter working with batteries OR solar. Anything that in range of 45-90V. So you could connect solar panels directly to inverter. In my case I have 16s LiFePo4 battery connected to inverter. you could check entire system here: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-kf9mkorFV2g.html
@lilanhtu
@lilanhtu 3 года назад
I do 2 panels in series come out 62 volt work fine with sun only. Will add battery in features :)
@gustavocamargo9340
@gustavocamargo9340 3 года назад
how is the operation of the 110v equipment? your inverter is 220v, in that case you put two sensors the grid will inject current into the network when you have 110v equipment? in my resistance I have 110v and 220v equipment. I used Google Translator
@gustavocamargo9340
@gustavocamargo9340 3 года назад
At the AC output of this neutral grid, another phase does 110v?
@SolarEngineering
@SolarEngineering 3 года назад
@@gustavocamargo9340 this video is for split phase systems, like USA/Canada/Mexico If you have only 110V, then you can use 1kW version of this inverter, it will work right out of the box. Let me know if I answered your question.
@gustavocamargo9340
@gustavocamargo9340 3 года назад
@@SolarEngineering I need an orientation, my resistance here in Rio de Janeiro the power supply is 1 neutral and 2 phases 120v. The 1000w grid tie limiter would only inject power in 1 phase 120v, the 2000w grid with 2 phases 120v injects energy in both phases. In my resistance I have equipment that works on 120v (neutral + 1 phase 120) and I also have equipment that works on 220v (two phases 120v). What would be the ideal grid tie limiter? Does the 2000w 220v grid work for 120v equipment? Or I have to put two 1000w grid tie limiter (one for each phase). Using Google translator , I live in Rio de Janeiro.
@SolarEngineering
@SolarEngineering 3 года назад
@@gustavocamargo9340 hi again, I don't know if 2kW version will work with 2 phases. You can install two 1000W inverters. One inverter on every phase, then I think it should work properly.
@gustavocamargo9340
@gustavocamargo9340 3 года назад
The 2000w grid tie limiter would have to have two separate inputs for the TC sensor . Only then would the equipment do the correct mapping in both phases regardless of whether it is using 120v or 220v biphasic.
Далее
ШАР СКВОЗЬ БУТЫЛКУ (СКЕРЕТ)
00:46
Easiest Grid-Tied Solar On The Market!   Plug-N-Play
11:12
Sun GTIL2 Troubleshooting
10:02
Просмотров 6 тыс.
Grid-tie 2000W Inverter Testing
14:12
Просмотров 3,6 тыс.