Тёмный

Customer Called And Said the Blower Won’t Shut Off!  

HVAC GUY
Подписаться 67 тыс.
Просмотров 30 тыс.
50% 1

In this video I visit a mobile home, the tenants said they can’t turn off the blower! #hvacguy #hvaclife #hvac #airconditioner #heatpump #hvactechnician #furnace #hvactrainingvideos #hvacinstall #hvacinstall #mobilehome
Merch Store : hvac-guy-2.cre...
HVAC LIFE FB Group: / 521086622906115
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Inficon D-Tek Stratus: amzn.to/3RvnXOl
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Blutooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
Makita XDT16: amzn.to/3riXuaJ
Makita 18V Light: amzn.to/3Fw4GW4
Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
Makita Jobsite Radio: amzn.to/3HuVp2u
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Fluke 975 Air Meter: amzn.to/3GwD9oM
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Aims Power Inverter: amzn.to/3qOSc87
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
American Flag Gator : amzn.to/3rKBl5u
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

5 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 52   
@danobrien3109
@danobrien3109 Год назад
Most units will go to continuous fan when an open limit or roll out occur. This is a built in safety in a lot of control modules.👍👍🇨🇦
@ilovecannabisalot7324
@ilovecannabisalot7324 4 месяца назад
Wtf does a roll out mean
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
Good video. You’re are really good at electrical troubleshooting
@HVACGUY
@HVACGUY Год назад
Thanks 👍
@paulmoffat9306
@paulmoffat9306 Год назад
Relays can 'weld' their contacts, after enough actuations - each open/close has a small arc that pits the contact surface over time.
@tphvac87
@tphvac87 Год назад
Omg that filter is epic!!! Change your filters people!!
@jazziez6467
@jazziez6467 8 месяцев назад
my blower was stuck on and for the $100 service call the guy pushed the reset(red) button in on limit or rollout switch hiden below the burners, $100 then left without even putting it back together, I had it spotless when he arrived and would never have such filth on my doors, filter, or inner furnace, never
@kens.3729
@kens.3729 Год назад
Thanks Curtis! Hello 👋 Riley! 👍🙏
@RicardoPereira-k5b
@RicardoPereira-k5b Год назад
You are the best down south Curtis… Rick from United Americas Plumbing • HVAC. 🇺🇸🤜🤛🇺🇸
@HVACGUY
@HVACGUY Год назад
Thanks
@billybrown1979
@billybrown1979 Год назад
that was a quick fix good work. be safe.
@Capt-Intrepid
@Capt-Intrepid Год назад
I had a defective POS Nest thermostat that would turn the blower on but not the compressor. Now using a ecobee thermostat that understands I am the master. Don't buy Nest.
@caru3257
@caru3257 Год назад
Can I get an Amen?
@jhatfield2755
@jhatfield2755 Год назад
Dont buy a nest or a ecobee lo
@markspott1741
@markspott1741 7 месяцев назад
Excellent video of troubleshooting the blower. Probably saved another call by changing out the air filter too!
@sjadev
@sjadev Год назад
I always appreciate how thorough you are Curtis
@robalexander7348
@robalexander7348 Год назад
A nice fix Curtis, and so good to see a new clean filter change 👍 Au
@HVACGUY
@HVACGUY Год назад
Thanks 👍
@carlsmith5919
@carlsmith5919 Год назад
I was starting to wonder when you were going to lay down so you can reach that screw. I hate those units, they have so limited hand space behind the line set. I worked one a while back, where someone replace both relays😮😮 with contacts, in that small space.
@odc43054
@odc43054 Год назад
I had an ECM fan motor on a 10 year old Payne package unit that would continue to run even with the control wiring removed. Motor had to be replaced. Bad electronic brain.
@larryl2459
@larryl2459 Год назад
First 2 minutes I noticed they are going to have more than fan troubles.
@Tito-hvac8
@Tito-hvac8 Год назад
Great job. You make it looks easy but it’s not. It takes time to get there👍
@RossTheGenMan
@RossTheGenMan Год назад
Nice work and Explanation. Not sure if there was a filter in the door before you started?
@HVACGUY
@HVACGUY Год назад
No there wasn’t
@stevencossaboon3237
@stevencossaboon3237 Год назад
Nice work Curtis.
@bamatractor
@bamatractor Год назад
I had a brand new blower control board stuck on a few days ago.
@johnnym.rodriguezr3562
@johnnym.rodriguezr3562 Год назад
Great job diagnosing!
@treyconner1991
@treyconner1991 Год назад
You can never have to many flashlights. 🤙🏻
@woodystokes1543
@woodystokes1543 Год назад
Nice work 😊
@HVACGUY
@HVACGUY Год назад
Thanks 😄
@woodystokes1543
@woodystokes1543 Год назад
@@HVACGUY you’re welcome I hate that they run he line set in front of the control panel.
@bobboscarato1313
@bobboscarato1313 Год назад
@@woodystokes1543 Pretty poor design for downflow heater; however on the right side they have plenty of room to run the refrigerant line set and the drain line!
@CommercialGasEngineerVideos
Another good video
@sergiohernandez4163
@sergiohernandez4163 Год назад
Them mobile home units sequencers always confuse me lol. I'm just a beginner on working on mobile home furnace
@frankblankenship3026
@frankblankenship3026 Год назад
Very informative thanks
@fernandobazan829
@fernandobazan829 Год назад
Can’t see what your explaining with those wires i guess camera angle is off what controls that relay? The thermostat or the pcb?
@HVACGUY
@HVACGUY Год назад
Thermostat
@fernandobazan829
@fernandobazan829 Год назад
so basically the thermostat send a call 24 V two the sequencer the sequencer send the 24 V to that peanut relay to turn the fan on. Also the thermostat could send 24 V to turn on the air conditioning and also turn on the fan from that same relay, so if that relays stock the fan to beyond all the time, no matter what good job
@ThomasWalker-m2y
@ThomasWalker-m2y Год назад
Dr Curtis is on the job he fixes ot the first time. Unlike Medical Doctors that just keep you coming back to run up your bill. Lawyers, Doctors, and Weathermen, should be paid on whether the do the job right the first time. Most every other profession gets paid only if they fix it right the first time. That's why they all it a practice, and want paid any way.
@steveurbach3093
@steveurbach3093 Год назад
What is with the seriously dirty filters?
@fernandobazan829
@fernandobazan829 Год назад
One more quick question what are you calling a sequencer?
@fernandobazan829
@fernandobazan829 Год назад
never mind I looked it up I call it a heat relay thanks anyway ur a smart tech
@bobboscarato1313
@bobboscarato1313 Год назад
It brings in one heat strip at a time the reduce power surge!
@mos8541
@mos8541 Год назад
the oooole 9340...
@harrydickson4575
@harrydickson4575 Год назад
👍👍👍
@jamierushing
@jamierushing Год назад
Hi bro from west Alabama
@HVACGUY
@HVACGUY Год назад
What’s up man
@jamierushing
@jamierushing Год назад
@@HVACGUY nothing much
@GodisAgapelove4172
@GodisAgapelove4172 11 месяцев назад
If this doesn’t get fixed will it cause an increase in my electric bill?
@benfilipino
@benfilipino Год назад
Can u recommend an honest tech right here in pinellas county, Florida?
@karellodewijks4971
@karellodewijks4971 Год назад
😊😊👍👍
@kylemason5951
@kylemason5951 Год назад
Could be the blower module or relay
Далее
Indoor Fan Keeps Running - 10 Reasons Why
20:19
Просмотров 553 тыс.
这位大哥以后恐怕都不敢再插队了吧…
00:16
Песня РАСПУТИН на русском!🔥
00:56
Furnace Fan Won't Stop Running! Thermostat Off
7:48
Просмотров 3,7 тыс.
You're wasting money on heating! Use your A/C!
17:11
Просмотров 604 тыс.
A/C Condensing Unit Runs Constantly T-stat is OFF
8:25
这位大哥以后恐怕都不敢再插队了吧…
00:16