Welcome to Ecobubl Technical Series.
Emilie explains how the Daikin High Capacity Heat Pump is wired.
If you're an Installer and require more training on Daikin Heat Pump, give us a call, we are also looking for Quality Installers to join our recommended list.
Nationwide Distribution of Heat Pumps, Mixergy Cylinders, accessories and Smart Controls.
www.ecobubl.co.uk

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 45   
@UrbanPlumbers
@UrbanPlumbers 9 месяцев назад
Daikin wiring - ohh boy, just why do they have to make it so complex. Heating heat pump manufacturers for me all day long. I will save this video for this unfortunate day I have to work on Daikin again. Keep up the vids.
@ecobubl
@ecobubl 9 месяцев назад
Many thanks, glad this video will be of use to you in future. 🙂, by the way love your videos...
@solexxx8588
@solexxx8588 Год назад
HMI = Human machine interface. Unbelievable that it's still called a MMI by Daikin in the UK. Emilie is the best HVAC presenter I have ever seen anywhere. Good work! Thanks.
@ecobubl
@ecobubl Год назад
Yes think that’s wrong
@markcranmer92
@markcranmer92 Год назад
Well done guys😃
@simonfoulsham6867
@simonfoulsham6867 Год назад
Great video. Being an NICEIC approved installer looking to install these units please keep them coming as this helps us decide if this is an area to want to work in. One item you have missed off the consumer unit is surge protection this in now a mandatory requirement.
@ecobubl
@ecobubl Год назад
Hi Simon Many thanks, yes we have many more videos planned. Oh yes we have forgotten the surge protection, we will definitely included that in our kit to installers. If you want any advice on heat pumps please feel free to get in touch. 😀
@uzairhassan8733
@uzairhassan8733 10 месяцев назад
Very well explained dear q
@romanpajak9215
@romanpajak9215 Год назад
Great video I think that Daikin need to look into having terminals for secondary heating pumps if they require you to have a buffer so you can still use there own controls. Using a on/off thermostat like a hive I have found to be much less efficient as there is no hysteris and causes the heat pump to switch on/off way to often. I have now switched to pure weather compensating the heat pump and seems a lot better once you get the curve set right.
@danielmoura3879
@danielmoura3879 Год назад
I bought the Daikin Monoblock 6Kw today and will be able to install it myself thanks to your detailed videos! Super detailed explanation, professional at work! Greetings from Germany!
@michaelnapo4221
@michaelnapo4221 Год назад
Hi Daniel, did you have any troubles with your diy-installation? Or was is "plug and play"? Gruß Michael
@danielmoura3879
@danielmoura3879 Год назад
@@michaelnapo4221 Hi, Plug and Play.
@michaelnapo4221
@michaelnapo4221 Год назад
@@danielmoura3879 Cool. Probably an alternative to the Aquarea from Panasonic. Did you install a buffer tank, or only the floor heating system?
@danielmoura3879
@danielmoura3879 Год назад
@@michaelnapo4221 yes a 50 L buffer Tank, i only use this Daikin for the floor heating, for the Warm water i use another Daikin Pump! In this Moment im heating with the Daikin Split heatpump, its Work very good!Are you German? Mfg Daniel
@michaelnapo4221
@michaelnapo4221 Год назад
Yes, I am. :-) As this Video is in english, I found it polize to write also in english. Ok. But in comparison to the amount of water in the floor heating system, the 50L buffer should be negligible?! Why did you choose the Daikin an not e.g. a Aquarea from Panasonic, as they are quite cheaper?
@luclynn1118
@luclynn1118 Год назад
Brilliant video. I wonder could you make a video on wire connection between daikin Hest pump and hive controler . Thank you
@tobymccoll6079
@tobymccoll6079 Год назад
Great video! Do you have to use the Dakine Madoka wired thermostat - or am I able to wire in another thermostat to the MMI that offers me more features? e.g ecobee.
@michaelporter2295
@michaelporter2295 5 месяцев назад
did you do a video on the basis of having a preplumbed cylinder?
@amateurwizard
@amateurwizard Год назад
That was a funny intro 😂
@martintom7390
@martintom7390 Год назад
Hello. I have a question concerning Wiring the control panel. If I take of the part with the screen there is a green bar with 4 connection points on the left. If I look at this green bar where is the point to fix pin 15 and 16 coming from the outdoor unit.
@lukaszhydraulik3306
@lukaszhydraulik3306 Год назад
👍💪
@wobby1516
@wobby1516 10 месяцев назад
I’ve a Honeywell home system of smart TRVs that act as independent zone valves if one opens calling for heat, power is output to my existing gas boiler. Octopus Energy will in the near future be installing one of your heat pumps. What I’d be interested to know is will my Honeywell smart TRVs work with your heat-pump
@bojan23
@bojan23 Год назад
In my country Daikin instillers telling me that they don’t put buffers any where that they instal pump? How is your experience? Isn’t that bad for short cycle for compressor? Thx
@dlahat
@dlahat 6 месяцев назад
Is it possible to make a video about FCU?
@miwat111
@miwat111 Год назад
Hi Emilie, great video! World be great if you helped me with an issue on my 3m..... my electrician pulled only 1 cable 5×4mm2, and only 1 30 Amp FI. There is no 2nd supply for the Backup theatre..... can this be right?
@ecobubl
@ecobubl Год назад
Hi Michael That doesn't sound correct, you need to install each power supply individually, so 2 or 3 supplies (compressor, back up heater and Booster heater/immersion supply)
@mathieulh5386
@mathieulh5386 Год назад
I wanted to connect my relay to control the heating, but I have 230V on the pin 35 and 0V on the pin 30. Do you have the same values ?
@ecobubl
@ecobubl Год назад
Yes, until you send a neutral feed back from 30 to 35, it will give you 230 volts, it’s the same as a light bulb 💡 if you take away the neutral you will have 230 volts on the neutral connection. So In short this has to be voltage free, so link terminal 30 & 35 together. If you put 230 volt into terminal 35, it will blow the board.
@mathieulh5386
@mathieulh5386 6 месяцев назад
I did it, and it works, but, since some weeks, I have an issue. When the temperature is cold (under 5°C), after 1 or 2 hours, the leaving temperature fall to the lower value available (35°C), even if the law water ask 45°C@@ecobubl
@ecobubl
@ecobubl 6 месяцев назад
@@mathieulh5386 could be simple flow rate issue, check the filters are clean. Or heat pump could be undersized for the property
@mathieulh5386
@mathieulh5386 6 месяцев назад
@@ecobubl thank you for the answer, I will check it This issue appears only with only when I choose to command the heat pump by the external thermostat
@skinnzthedon
@skinnzthedon 3 месяца назад
HELP!! were stuck on this bit! So if/when we link 30 and 35. Do we then send a wire each from 30 and 35 back to our room thermostats/ heat enables Lr and Ls? Would massively appreciate any help. And can this be done without the relay? @ecobubl
@matthewmilne
@matthewmilne 9 месяцев назад
@ecobubl have you issued the video on the preplumbed Daikin tank yet 5:00
@ecobubl
@ecobubl 9 месяцев назад
Hi, Sorry I'm afraid we have done this yet, hopefully soon, happy to send you a wiring diagram if you send us your email address.
@matthewmilne
@matthewmilne 9 месяцев назад
@@ecobubl perfect thanks. I will drop you my email. ❤️ the channel 😊
@skinnzthedon
@skinnzthedon 3 месяца назад
Hi would it be possible for a diagram ad well please?!
@martintom7390
@martintom7390 Год назад
Hello to All. Since 3 weeks I operate a Daikin altherma 3 M and use the basic Set up for for floor heating System. Because I have a house that is not very well insulated I need 33 degree flow temperatur and return is 30 degree. The flow rate is 22 l/min. The average outside temperature is 7 degree. Right now i am quite disappointed about the cop as well as the daily performance. The daily performance is only 4.0 The power consumption while is 0.9 kw only. I do not know why the machine has a really bad daly performance. I hope that someone could give me an advice.
Далее
NEW Daikin Altherma 3 M R32 Monobloc Installation
20:02
🤡Украли У ВСЕХ🤪
00:37
Просмотров 251 тыс.
Daikin Altherma ESBE 3 way valve explained
8:06
Просмотров 14 тыс.
How a plate heat exchanger works with a heat pump
5:01
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Просмотров 24 тыс.
Unboxing the Daikin Altherma 3 Monobloc
14:41
Просмотров 27 тыс.
Daikin Altherma 3 working principle
4:07
Просмотров 116 тыс.
Power on and Initial Settings
5:59
Просмотров 34 тыс.
Electric Heat Strips (Wiring For Beginners)
13:49
Просмотров 38 тыс.
🤡Украли У ВСЕХ🤪
00:37
Просмотров 251 тыс.