DCS800 Drive, FIELD CONTROL AND TESTING, HOW TO CHECK FIELD IN LOCAL, HOW TO FIELD ON | 

Knowledge Development Channel
Подписаться 3,4 тыс.
Просмотров 3,9 тыс.
50% 1

#Knowledgedevelopmentchannel
This channel providing information regarding daily routine follow by an electrical engineer. An electrical engineers, how to works in plant by automation and how to update day to day in his life,all these knowledge in this channel.
#hitkumar
Every day in this channel, we share the upcoming things of the people daily.
Watch this video and learn and follow. I hope you will definitely get benefit.
In this video you can see how to operate abb dc drive in local mode, how to check field voltage, field resistance, how to check field current and others.
DCS800 DC Drive Promises The drive meets the requirements of the most demanding drive applications. Embedded software functions offer upgrades to all classic installations like 12-pulse, double motor operation, and field reversal.
What is the function of DCS800?
The DCS800 provides an internal PLC function with adapt the drive to demanding applications like cranes and winders. To archive higher field currents external field exciter, must be used. External field exciters with field currents up to 520 ADC are available.
What are the components of a DC drive?
In order to realize how a DC drive has the capability to provide the above characteristics, the DC drive has to be analyzed as two elements that make up the package. These two elements are of course the motor and the control.
What is DC drive and how does it work?
A type of electric drive which is employed for controlling the speed of a DC motor is known as DC drive. The DC drive converts the input AC supply to the DC supply output using the rectifier circuit to control the speed of the DC motors. The DC drives are of two types viz.: analog DC drive and digital DC drive.
Checking Relative Polarity of DC Motor Fields:-
1. Connect a low scale (3 volt) DC voltmeter across the shunt field terminals (F1, F2) with F1 connected to the positive (+) terminal of the meter. At least one of the shunt field leads must be disconnected from the controller.
2. Use two flashlight batteries as a source of low voltage (3 volts). Hold or connect the negative, to contact the S-2 series field terminal. Hold one end of a wire conductor to the positive (+) center terminal so that the
other end of the wire can be used to make and break contact with the S-I series field terminal.
3. Watch the deflection of the voltmeter needle when contact is made with S-I and when contact is broken.
4. When contact is made, the needle will first deflect in either the up scale or down scale direction and then return to zero. Deflection will be in the opposite direction when contact is broken.
5. Relative polarities of the shunt and series fields are correct (ampere-turns are cumulative) if the voltmeter needle deflects up scale when contact is made and down scale when contact is broken.
6. Relative polarities of the shunt and series fields are incorrect (ampere-turns are differential) if the voltmeter needle deflects down scale when contact is made and up scale when contact is broken. The motor connections must be changed so that relative polarity is correct. Relative polarity can be incorrect because of an error in the connections to the control or because the series fields leads are improperly marked. In any case, the motor connections must be changed so that relative polarity is
correct.
If only one series field terminal is available at the controller, use it and the available armature terminal for the test. For example, use S-2 and A-l, if S-1 and A-2 arc connected together at the motor and not brought to the
controller.
If you have an oscilloscope, you can use it in place of an analog meter. I have done the same test procedure using a 9v battery and my scope. This procedure also works to determine armature wires that are not labeled. Typically A1 lead will tie directly to one of the brush racks and the A2 lead will come from a special winding which is tied in series to the opposing brush rack of A1. This special winding is called an interpole.
It is very important that S2 and F2 are always tied to the negative outputs of the controller. If the motor is running the wrong direction, swap armature leads.
If the motor controller (DC drive) is regenerative then tie S1 and S2 together or tape off each lead separately and don't use them at all. A good example of a typical DC motor connection
In this video you can know about voltage and current measurements one by one increase through percentage and how to operate dc drive by abb dcs 800 and operate to dc motor.
In this video you can test to dc motor also.
# • SCR Part 2 | SCR WORKI...
• PLC PART 1💡 || PLC INT...
# • Scr part 3 || Question...
# • working of thyristor||...
• Insulation class | Ins...
# • Agc Control Rolling Mi...
# • SCR Part 2 | SCR WORKI...
# • SCR PART 1|| 🤵HOW TO T...
# • Star Delta control wir...
• Torque and Tension, T...

Наука

Опубликовано:

 

3 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 20   
@gufransaifi3175
@gufransaifi3175 11 месяцев назад
Thank you sir
@user-zp4yj6jk1y
@user-zp4yj6jk1y 7 месяцев назад
Sir if i changed a motor field voltage 110 to 220 v what parameter or wiring to be chaned in drive dcs 800
@hearttouchingwords6221
@hearttouchingwords6221 6 месяцев назад
300 A dc load box ready karna hai to kon sa drive sahi hoga input volt 110 vdc hai
@user-zp4yj6jk1y
@user-zp4yj6jk1y 7 месяцев назад
If i change a dc motor having field voltage 110 to 220 which parameter/wiring to be changed
@gufransaifi3175
@gufransaifi3175 11 месяцев назад
Next video
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 11 месяцев назад
Wait 2- 3 days
@gufransaifi3175
@gufransaifi3175 11 месяцев назад
Sir all perameters details
@hasibansari7242
@hasibansari7242 23 дня назад
Dcs800 drive me x96 me kon sa wire connect hota hai sir ji
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 18 дней назад
Yah as a realy kaam karta hai ,yah output DO8 hai. As a dc contactor on /off ke liye use Kiya jata hai. Thanks for query, If any more query then ask me.
@hasibansari7242
@hasibansari7242 18 дней назад
Sir ji 24v dc out put deta hai
@kuldeepdhiman7570
@kuldeepdhiman7570 7 месяцев назад
Sir, Please guide me. ABB DCS800 me armature over volt ka fault aa raha h. Kya reason ho sakta h. Please bataye
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 7 месяцев назад
What is fault, fault is F503?
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 7 месяцев назад
Drive on karte hi trip ho raha hai ya thori der baad trip ho raha hai?
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 7 месяцев назад
Agar turnt trip ho raha ho to cable check karo or agar thori der baad trip ho raha ho to feedback ka problem ho sakta hai.
@kuldeepdhiman7570
@kuldeepdhiman7570 7 месяцев назад
@@knowledgedevelopmentchanne8720 fault is F503. And ye 2day ya 10day ya 25day me hota h kabhi kabhi...
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 7 месяцев назад
Please check your encoder and speed feedback. When it trips that time please check speed of equipments. What is speed, may at maximum speed, it's trip. You can check also by bypass encoder.
@ashishgoyal9565
@ashishgoyal9565 4 дня назад
Sir aapka number
@user-zp4yj6jk1y
@user-zp4yj6jk1y 7 месяцев назад
If i change a dc motor having field voltage 110 to 220 which parameter/wiring to be changed
@knowledgedevelopmentchanne8720
@knowledgedevelopmentchanne8720 7 месяцев назад
110 v or 220 v ac incoming or dc out put?
Далее
ABB DRIVE CONNECTION WITH DIFFERENT MODE SELECTION
15:22
VFD Control Methods | Scalar Mode | Vector Mode
13:35
ELA NÃO ESPERAVA POR ISSO 🥶 ATTITUDE #shorts
00:20
Китайка Шрек всех Сожрал😂😆
00:20
🔴DC Motor Field Control and Parameters 🔵
12:24
Просмотров 11 тыс.
IGBT  TESTING
6:10
Просмотров 100 тыс.
Abb dcs 800 drive parameter settings
2:39
Просмотров 1,4 тыс.
ABB ACS150 Drive Parameter Settings
13:46
Просмотров 9 тыс.
iPhone 16 - 20+ КРУТЫХ ИЗМЕНЕНИЙ
5:20
Просмотров 101 тыс.
КРУТОЙ ТЕЛЕФОН
0:16
Просмотров 6 млн