Тёмный

Delta MS300 External Terminal Operation Control 

Delta VFD
Подписаться 852
Просмотров 18 тыс.
50% 1

How to configure operation commands (run/stop/direction) for the control terminals on the Delta MS300.
downloadcenter.deltaww.com/en...

Опубликовано:

 

11 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 26   
@jakubzborowski6426
@jakubzborowski6426 2 года назад
Thank's, very helpfull video. Greetings from Sohbi
@pauldering6539
@pauldering6539 5 месяцев назад
thank you very much.
@julioarias260
@julioarias260 14 дней назад
Hello there. Can this VFD be controlled by an RC-01 accesorie ? Thanks
@ReyRelacion
@ReyRelacion 17 дней назад
How to use the multi function relay output and what are the parameters thats need to set up? thank you.
@cerita-ceritanabi3343
@cerita-ceritanabi3343 5 месяцев назад
Hi, I would like to ask a question. How to save our parameter setting at ms300? because I when I was turn off the inverter and tried to running again, the inverter need seeting again
@fungelelanimaster8668
@fungelelanimaster8668 Год назад
❤️ 💞
@jimmontgomery8982
@jimmontgomery8982 3 месяца назад
Thank you for your video. I'm needing parameter setting information for using an external braking resistor. Can you help?
@deltavfd6406
@deltavfd6406 3 месяца назад
Hello, check parameters 06-01 and 07-00. Search for "brake resistor" in the manual pdf.
@MrBibinkk
@MrBibinkk 2 года назад
Sir i need to work this drive as a counter is it possible.. I tried but it didn't work
@raynelson3404
@raynelson3404 2 года назад
I am wanting to run a vacuum pump for my cnc table. I was to told split the wire from the vacuum on switch and put it on m1 and vcm. Is this a safe method to run the drive?
@deltavfd6406
@deltavfd6406 2 года назад
As long as it is a dry contact from MI1 - DCM and no additional power given to the drive control terminals, then yes.
@controlmate75
@controlmate75 2 года назад
can we take out the digital panel and use an extension wire or something so you can transfer the digital panel on the door of the main panel?
@deltavfd6406
@deltavfd6406 Год назад
Yes there is a keypad extension cable. The part numbers are in the accessories section of the manual.
@pds4927
@pds4927 Год назад
Hi, can you do a video on how to configure the ms300 to a lathe machine(Grizzly / Powermatic) using external switches/buttons to run the run/forwar/stop/reverse
@stevelillie4597
@stevelillie4597 7 месяцев назад
Hi pds4927. I'm Steve. I am trying to do just that..get an MS300 inverter to work on a PM 3520B. Did you ever have any luck configuring it with your lathe? I'm desperate. There are many more options than the original S inverter.
@user-fx8mv6jr1y
@user-fx8mv6jr1y 9 месяцев назад
Do you do consulting?
@0Saints0Photography0
@0Saints0Photography0 2 года назад
Hi Can you do a video of how to connect the MS300 to use a 24v pulse to increase and decrease the frequency if possible?
@deltavfd6406
@deltavfd6406 Год назад
Using an external 24VDC input, see the control terminal wiring fig 6-5 in the manual. Pulse input - the frequency of the pulses determines the speed. Check the description in parameter 10.16 External Up / Down - 00.20, 02.01 ~ 02.07 set to 19 and 20
@mattchu79
@mattchu79 2 года назад
Can I bypass it by connecting a wire from MI1 to DCM bcuz I want it to run as soon as I activate the external switch that provides power to it
@deltavfd6406
@deltavfd6406 Год назад
Yes, also check 00.21 for external terminals and 02.35 setting to enable it
@mrbonah8561
@mrbonah8561 Год назад
What about if the wires are 5. Control nob has 3 wires. Start and stop has 2 wires. How can I connect it
@deltavfd6406
@deltavfd6406 3 месяца назад
The potentiometer is covered in a separate video on connecting analog input.
@hapzc.j.
@hapzc.j. Год назад
fan not function how to
@r.dmotorcontrolworks5066
@r.dmotorcontrolworks5066 Год назад
Hellow sir...can you pls create video tutorial about 4 20ma using ms300..tnx
@deltavfd6406
@deltavfd6406 Год назад
Hi, for 4-20mA use the ACI terminal as signal and ACM terminal as common. For speed reference, 03.00 = 0, 03.01 = 1, 00.20 = 2. For PID feedback, 03.01 = 5.
Далее
Delta MS300 VFD Communication Parameters Setting.
7:39
How Many Balloons Does It Take To Fly?
00:18