Depyrogenation Tunnel Working principle & validation #sterilization #usfda #aseptic ‎@PHARMAVEN
Your Queries
1. What is Depyrogenation
2. How to qualify Tunnel
3. Hot Air Sterilization
3. Dry Heat Sterilization
4. Depyrogenation
5. Tunnel Qualification
#sterilization #sterile #heat #dhaval #usfda #aseptic
‪@PHARMAVEN‬
Why Air Removal is Required in Autoclave?
How to calculate F0 Value?
What is Overkill Cycle in Steam Sterilization?
#sterilization
#autoclave
#aseptic
#usfda
#steam
#bacteria
#bacterial
#filter
#pharmaknowlege
#sterility
#qualityassurance
#quality
#sterile
#gmp
@PHARMAVEN

Опубликовано:

 

6 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 29   
@PHARMAVEN
@PHARMAVEN Год назад
Excellent video on simple explanation about Depyrogenation Tunnel working principle, how to select container size and how to qualify tunnel for different container sizes
@SandeepSingh-td7yq
@SandeepSingh-td7yq 4 месяца назад
Thank you
@manikantasiva337
@manikantasiva337 5 месяцев назад
Very understandable and useful sir thank you
@upendrakushwaha8122
@upendrakushwaha8122 Год назад
Also explain Endotoxin challenge test during Tunnel validation
@arpitpandya8231
@arpitpandya8231 Год назад
Easy explanation with thorough understanding. Thank you sir.
@michaelscofield1577
@michaelscofield1577 Год назад
Very well explained, thank you
@kichootv
@kichootv Год назад
Depyrogenation Tunnel Working principle & validation
@dreams7763
@dreams7763 Год назад
Very helpful sir
@1985sourabhm
@1985sourabhm Год назад
Sir my heatly gratitude for the very good initiative. Please make video on cool zone sterilization also and how to place the sensor. Sir, should we keep Fh as the acceptance criteria, if yes then how much Fh is desirable or 3 log reduction of endotoxin is sufficient.
@nidhigarg3857
@nidhigarg3857 8 месяцев назад
Simple and knowledgeable video. One suggestion to jnclude the references of different guidelines used in industry. This will be helpful for viewers.
@PHARMAVEN
@PHARMAVEN 8 месяцев назад
Ok I will do
@dreams7763
@dreams7763 Год назад
🙏🙏
@harishthakur5124
@harishthakur5124 Год назад
Exllent sir
@ravendrakumar2646
@ravendrakumar2646 Год назад
Please provide the video of vial filling and sealing m/c
@ap14spt
@ap14spt Год назад
Thanks for sharing! My queries:. Is smoke study applicable for Tunnel ? If online flow Measurement then do we need to check Flow Measurement at 5 points Similarly about Filter integrity of Tunnel How is the industry practice? As all of above is not easy to perform. Kindly suggest or make vedio on this
@rajpalsingh6245
@rajpalsingh6245 Год назад
Sir please make a video for sip, cip
@thefactsshow5674
@thefactsshow5674 8 месяцев назад
Great 👍👍👍
@RAVI-sv9co
@RAVI-sv9co 6 месяцев назад
Sir thank you so much🙏 Can you please explain FH value
@PHARMAVEN
@PHARMAVEN 6 месяцев назад
FH value is same as F0 value Only difference is F0 value is for moist heat sterilization and FH value is for Dry heat sterilization
@PankajSingh-wu9zp
@PankajSingh-wu9zp Год назад
Kindly provide guideline references if possible
@uday4640
@uday4640 Год назад
Dear Sir, Please clarify following Points. 1.I have 10mL moulded and 10mL tubular vials with the same dimension. Can I Qualify only for 10mL Moulded vials? by considering worst case. 2.5mL moulded vials having 13mm Neck and 5mL tubular having 20mm neck.which one i should selected and Qualified? 3.2mL moulded and tubular vial having 13mm neck then which one is should consider worst case for Qualification?or both the vials should be Qualified? 4.when my vials having Type-1 and Type-3 with the same dimensions... Qualification should be performed for both the vials or worst case I can consider as a type-3 and recommended same parameters for type-1 vials? Thanks/Uday
@PHARMAVEN
@PHARMAVEN Год назад
10 ml Molded 5 ml 13 mm neck (less air penetration in vial with small neck) 2 ml Molded You can take approach as 2 ml minimum, 10 ml Max, three runs each 5 ml as one run verification
@ap14spt
@ap14spt Год назад
What should be the cooling zone pressure wrt Filling room . Kindly suggest
@PHARMAVEN
@PHARMAVEN Год назад
Filling Room should be positive to cool zone
@ArunYadav-qp8re
@ArunYadav-qp8re 9 месяцев назад
Dear sir plz confirm that can we understand the dwell time and fd value is same tunnel validation?
@balambpk
@balambpk Год назад
Why dwell time is 3mins sir.. can you explain sir???
@gopalbhambhariya8854
@gopalbhambhariya8854 Год назад
Dear sir please. Send all videos in Hindi language
@tinoandtini
@tinoandtini Год назад
Depyrogenation Tunnel Working principle & validation
Далее
Пчёлы некроманты.
00:46
Просмотров 29 тыс.
ke pantai karang jahe, @seruniwibowo
4:34
An Introduction to Isolator Technology
56:43
Просмотров 23 тыс.
Sterile Processing Technician--Donna Reich
12:14
Просмотров 940 тыс.