Тёмный
No video :(

DIESEL HEATER DISASTER! How To Install Diesel Heater & Error Codes - No Experience Van Build 

Will’s Whereabouts
Подписаться 291 тыс.
Просмотров 71 тыс.
50% 1

⚠️ Don't forget to LIKE & SUBSCRIBE ⚠️
👉 SUBSCRIBE HERE - www.youtube.co...
DIESEL HEATER - amzn.to/3lECx82
‪@UrbanVanlife‬ - / urbanvanlife
📸 Instagram - / willswhereabouts
In today's video I attempted to install a Chinese Diesel Heater step by step into the main fuel tank with ‪@UrbanVanlife‬. Sadly we had some error messages and codes that came up every time we started the heater so had to do some problem solving to see what was going wrong with my Chinese diesel heater.
CAMPER MATERIALS USED! 🚌 🛠️
🔥 Autoterm Heater
5% Discount Code - 'whereabouts5'
planarheaters....
🔋 Eco Tree Lithium Battery
10% Discount Code - 'wills10'
ecotreelithium...
🚙 Tyres
5% Discount Code 'WILL5'
www.roguealloy...
⚡ Electrical Set Up
✔️ Jackery 500 Power Station - amzn.to/3cD59tm
✔️ "32" Inch Light Bar - amzn.to/3vzBuwj
✔️ "22" Inch Light Bar amzn.to/3JXIKpq
✔️ Headlight Bulbs - amzn.to/3Iphboy
✔️ Victron DC-DC Charger - amzn.to/3AyHowX
✔️ Victron MPPT Solar Charger - amzn.to/3JvGHZB
✔️ Victron 1600W Multi Plus Inverter - amzn.to/3oVH6wx
✔️ Victron Cerbo GX (System Monitoring - amzn.to/3rPWc8F
✔️ Victron Smart Shunt - amzn.to/3HXxGrZ
✔️ Max Air Fan Deluxe - amzn.to/3xIhUvA
✔️ Touch Sensitive LED Lights - amzn.to/3Courr9
🏕️ Van Essentials
✔️ Portable Toilet - amzn.to/3rRLOgL
✔️ Jet Boil - amzn.to/34KtmKW
✔️ Fold Up Camping Table - amzn.to/3vWsIEQ
✔️ Portable Gas Stove - amzn.to/3A8hOPU
✔️ Condensation Vaccum - amzn.to/3rvtR5p
✔️ Thrunite Torch - amzn.to/3933N9r
✔️ Super Strong Magnets - amzn.to/3BgCAgO
✔️ Hook Magnets - amzn.to/36ZQhTf
✔️ Knife (2in1 Sharpener) - amzn.to/38yhmNO
✔️ Carbon Monoxide Alarm - amzn.to/3prmPwO
✔️ Gas Canisters (Jet Boil) - amzn.to/3rvHqBU
✔️ Gas Canisters (Stove) - amzn.to/3pp1K64
✔️ Foldable Washing Up Bowl - amzn.to/38Dp3lR
✔️ Water Contatiner - amzn.to/2Ds8UUW
✔️ Wheat Bowls - amzn.to/3rpS8d0
✔️ Wheat Plates - amzn.to/3aHfuoF
🛫 Become A Patreon
/ willswhereabouts
🤟 Join The Travel Community!
/ @willswhereabouts
🛒 AMAZON STORE 🛒
www.amazon.co....
‪@WillsWhereabouts‬
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
SEE MORE VIDEOS ▶️
No Experience Van Build Playlist - • No Experience Van Build
Stealth Car Camping Playlist - • Stealth Camping
FOLLOW ME TO SEE MORE OF MY TRAVELS! 🌎🚶‍♂️
🎬 RU-vid - / willswhereabouts
📸 Instagram - / willswhereabouts
👍 Facebook - / willswhereabouts
📧 Email - will@willswhereabouts.com
HELP SUPPORT THE CHANNEL! 😊
🛫 Become A Patreon - / willswhereabouts
💸 Paypal - www.paypal.me/...
DISCOUNTS! 💲🤑
🎵 Where I Get My Music - www.epidemicso...
🏠 DISCOUNT on Airbnb - www.youtube.co...
MY EQUIPMENT! 🎥
👉 Vlogging Camera - amzn.to/3aYa4lG
👉 Action Camera - amzn.to/2z6ZuM3
👉 Main Lens - amzn.to/2yvrHMl
👉 Second Lens - amzn.to/3dlysz1
👉 Gorilla Tripod - amzn.to/2zas9j8
👉 Big Tripod - amzn.to/2ykqIyN
👉 Camera Microphone - amzn.to/2YyRy0H
👉 Drone - amzn.to/38EkMP1
👉 Laptop - amzn.to/2TTFT9p
**Make sure to subscribe to my channel!**
DISCLAIMER: Links included in this description might be affiliate links. If you purchase a product or service with the links that I provide I may receive a small commission. There is no additional charge to you! Thank you for supporting me and my channel.

Опубликовано:

 

26 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 333   
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Well the heater may not be working but still plenty of lessons learnt. Going to be tackling it again later in the week so any advice or suggestions let me know 🤙🏼
@BigVanSmallWorld
@BigVanSmallWorld 2 года назад
Hay Will I just recently fitted a 2kw heater it lasted a week gone back to my old 5 kW good luck
@andymcclelland4243
@andymcclelland4243 2 года назад
The reason it’s not working is because you have fuel filter around the wrong way and your using the shit fuel pipe that comes with it if you go on eBay for about £10 you can get the uprated fuel pipe that is hard and your have no problems if your local to bmth I can help you
@wingingit3071
@wingingit3071 2 года назад
its best to use hard line between the pump and the heater :)
@mp180170
@mp180170 2 года назад
Winging It definitely over the exhaust 👍🏼
@James_Howarth
@James_Howarth 2 года назад
It looked like there was air entering the fuel line after the fuel filter, did you check the filter for cracks and the connection after the filter?
@inmyhoose
@inmyhoose 2 года назад
God bless the internet, Sunday night in a chilly Scotland and I'm lying in the bath watching a scouser in a onsie fit a heater to a stealth campervan 🤣. Great stuff chaps, keep up the vids 👍
@El-Tel63-Terry.
@El-Tel63-Terry. 2 года назад
Yep, the internet is a strange but very funny place at times ! 😂😂👍🏻
@Flash685.
@Flash685. 2 года назад
Not just any old onesie, a teddy bear one 😂🙌
@WillsWhereabouts
@WillsWhereabouts 2 года назад
😂😂😂 this cracked me up
@overlandingwolf
@overlandingwolf 2 года назад
Hi bud - I have fit a few of these in my time. Here are my points. - the fuel filter is set the wrong way around (I know you discounted it) set this as close to the tank as poss and the screw cap end is the towards heater end. - the pump with such a long run dry can destroy itself I would swap out the pump first. - the green line is pretty rubbish, it expands with the pump pulses - swap this out to hard nylon line asap and set the pump as close to the heater as possible - the longest run suggested for the pump is 2m from tank to heater - less with green line. Hope you figure it out, if you need a extra pair of hands I’m in Bristol if you need help.
@UrbanVanlife
@UrbanVanlife 2 года назад
If it was the wrong way round it would push air in to the main tank and not suck fuel out lol
@BigVanSmallWorld
@BigVanSmallWorld 2 года назад
@@UrbanVanlife Hay Neil ya nutty bugger ya had the fuel filter the wrong way round not the pump not that it matters lol good effort
@overlandingwolf
@overlandingwolf 2 года назад
@@UrbanVanlife as Mel said bud :)
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Thanks Tim, will give these things a try and hopefully they work out
@UrbanVanlife
@UrbanVanlife 2 года назад
@@BigVanSmallWorld it’s a 2 way filter . So that means no matter what way you put it the fuel is filtered in that direction . So even if it was the direction of the filter . That dose not explain why it was erroring with by passing the filter .
@ap8407
@ap8407 2 года назад
Hello Will, I installed one of these last week. I would say change the green fuel line to a smaller diameter white nylon fuel line; available on ebay for a few quid. Not a 100% wether that will solve the issue, as you guys tried with a short run from the fuel can. But definitely worth giving a go
@richardmillican7733
@richardmillican7733 2 года назад
Yes the white harder fuel lines are better... But, will needs to turn of the internet, and get Scotty road man, to put the in line filter the right way around??
@abdulbham3406
@abdulbham3406 2 года назад
Hey Will hope your well and still fighting the diesel heater. I suggest you get the white nylon pipe and also use a separate tank as close as you can to the diesel heater so the pump doesn’t have to work too hard also that way you’ll be Abel to use red diesel as that’s much cheaper. Hope this help x
@robbblair6289
@robbblair6289 2 года назад
She looks like a pro. What a beautiful area. Thank you for sharing.
@thinkingoutofthebox.9421
@thinkingoutofthebox.9421 2 года назад
I fitted a 2kw diesel heater because my van is a small Transit custom SWB hightop. Mel fitted a 5kw in his mwb sprinter and it was too hot on lowest setting. I didn't use the soft green pipe, I used a thinner hard pipe, and with the Transit clip on attachment you just cut off the spare auxiliary spur on the Sender unit on the van fuel tank and push the straw in and clip it on, all worked fine.
@thebeardedgeordiephotography
@thebeardedgeordiephotography 2 года назад
Mate I've got a little nissan nv200 and the heater that turned up for mine was a 5Kw version 😳 it's in the garage for now but I'm seriously contemplating fitting it anyway for this winter (use it for astrophotography) and change it next spring for a 2Kw. I should think it will only be on for ten mins at gas mark crematorium to keep me toasty 😂😂😂😂
@martinwyatt6390
@martinwyatt6390 2 года назад
Hiya will, throw that crap heater in the bin, and get urself a multi fuel burner, Pipsqueak is what u need, u have the room, the stove comes with its own hearth, u can cook on it, there's no noise, it will stay in all night, and u will b to warm, but better tha being cold, loads of wood about, , it burns s.mokeless coal as well which burns longer and is hotter, am glad i got one in my van, Happy new year Will😃
@davidbloomfield4135
@davidbloomfield4135 2 года назад
Everyone needs a Neil in there life...LEGEND...keep going Will you'll crack this and like you say your learning
@Kitfoxmk1
@Kitfoxmk1 2 года назад
Sorry to see you had trouble. I’ve just fitted a 2kw heater to my boxer and it provides more than enough heat, even on its lowest setting. It’s been fantastic and hasn’t given any trouble. As far as I can see the only difference I have to yours is that I’ve used a separate fuel tank, it has a shorter fuel run, incidentally im pretty sure you’ve got the filter the wrong way round (you need to be able undo it and have the crud on the outside of the filter so you can clean it). I primed my fuel line using a 50ml syringe and dragged the fuel through to the heater. My fuel pump is very close to the heater but obviously under the floor. All the reviews I’ve seen are excellent as is mine so hopefully you will get it sorted and still have spent only one tenth of the European version!
@fairysrreal180
@fairysrreal180 2 года назад
My stomach is still recovering from watching the bloopers, thanks Will.🤣😂🤣
@pengoocamper
@pengoocamper 2 года назад
😱 oh no I got 2kw heater to go in mine (cos like will ) tight on the purse strings.....lol...But yep .white fuel pipe is a must upgrade if you not got it in the kit ...all ready ordering one too ... Let us know if you do get the 2kw running or just go direct to the 5kw .....you get there one day Will....with a little bit more help from Neil....🤞
@feebeeadventures-vanlife7818
@feebeeadventures-vanlife7818 2 года назад
Everyone needs a Neil - can we have him after you have finished with him? 🤣 Especially if he keeps wearing those Yogi Bear trousers! Loving your content 👍🏼
@grahamball7243
@grahamball7243 2 года назад
Not having a lot of luck lately are you Will. It's not easy to keep your patience when a few things go wrong at the same time. At least with Neil and his experience of installing Chinese Diesel Heaters you know it was a fault with the product you bought. The good thing about all this is you now realise it's better to go with the 5kw heater instead of the 2kw heater that you had. All this is good experience for any other van builds in the future. Stay strong mate, you'll get there soon. Graham 💪
@parkay3560
@parkay3560 2 года назад
taking out that sender unit was like The enterprise ejecting her warp core. Having my heater fitted this week. I'm so glad someone else is doing it 🥵 I should have got Neil and Em to convert mine. I'm only up the road from them lol and it would have been finished now.
@bluej511
@bluej511 2 года назад
That fuel hose isn't gonna last id keep an eye on it. I think its gonna rub thru going into the sender. Frim what ive read the hard nylon hose is a better choice.
@WillsWhereabouts
@WillsWhereabouts 2 года назад
I’ve bought the new nylon one so hopefully this does the trick
@bunglefarian9853
@bunglefarian9853 2 года назад
I would get a Fuel Tank Sender Stand Pipe Pick Up Hose Clips Kit For Eberspacher Diesel Heater of ebay.
@bluej511
@bluej511 2 года назад
@@WillsWhereabouts nice glad to hear mate, wouldn't want it to fail and start leaking fumes.
@shaunhardwick9759
@shaunhardwick9759 2 года назад
i just fitted mine recently and had a few issues with just getting smoke and it shutting down after 2 min, i decided to blow through the air intake a few times while it was starting up as hard as i could, kept doing it while it was fireing up and hepresto it it fired into life and its been great ever since
@richardkelly4254
@richardkelly4254 2 года назад
My money would be on the fuel lines, you need hard nylon ones. When the pump sucks on soft tubing like that it collapses the pipe (cavitation) rather than suck fuel from the tank.
@librab103
@librab103 2 года назад
That might be the problem. I do not know why these kits come with soft green tubing instead of ridge nylon that I am sure if these companies bought in bulk would maybe add $1 to cost.
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Thanks for letting me know I’ve bought the nylon one which should arrive soon
@davehoughton9663
@davehoughton9663 2 года назад
Is Neil , Ricky Tomlinson’s love child?😆
@suziemc5291
@suziemc5291 2 года назад
Neil in a teddy bear onesie............really phwarrr 🤣how could you take him seriously that's so funny. vans looking good tho, he knows his stuff. we had the same trouble with ours and in the end we demanded a replacement mother board which they sent and it worked.
@MrDodgeeames
@MrDodgeeames 2 года назад
Had an issue with my 2kw for my vw transporter after 6 months installed. Same error codes cap as yours Will. Took it apart and it was coked up, cleaned it out put it back together has been good as gold since now for last 18 months.
@rogerhargreaves2272
@rogerhargreaves2272 2 года назад
Aww Will, those diesel heaters are a complete nightmare to fit, what with all the right ways to put the filter etc etc, I feel your pain. The all in one solution is an option like your Jackery. Yes, you both did everything correctly, just those damn error codes. I thought you cracked it when the fan on the controller was spinning, but alas it didn’t work. I can’t think of anything. Neil is experienced so he knows. Great van build video, thanks Neil & Emma. Good luck with part 2. Rog.
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Thanks Roger, think it was mostly likely the dodgy green pipes they come with so I’m changing this out
@Rockhopper1
@Rockhopper1 2 года назад
the flange-spring is offset to the conurbation union joint, is so obvious if you look at the google sprocket as it in a concentric arc, best thing to do is use high magnetic frequency plates to disjoint the flux. A flux capacitor is required, warning do not hit 88 mph that if your lithium battery can supply the recommended gigawatt required use the doc brown equation method. Good luck bud glad to have off help.
@grahamstaddon9990
@grahamstaddon9990 2 года назад
Good effort Will, Neil and Emma. Glad to see you went down the turret plate route. Can’t help with E-08 error but have heard the green pipe is rubbish. Mine came with the white line but I’ve not installed it yet
@markparish9072
@markparish9072 2 года назад
Dont know how your timeline and socks with sandals timelines are running exactly but it might be worth you contacting each other and he has a contact for silent pumps. only a thought best of luck. Neil n Emma loving the assistance for those not in the know, seen the efforts with the trolls, keep up the good work and have some time to yourselves
@Wayno_50
@Wayno_50 2 года назад
Some people have swapped the 5kw for 2kw saying they get too hot, even on the lowest . I’ve got a 5kw but it had 4 outlets so I’ve got them going to the shower room and other parts in the van and that’s all good for me 👍🏼
@nickpritch3152
@nickpritch3152 2 года назад
Considering Neil has fitted a few of these heaters still fitting the shit pipe wrong size bore and a waste of time as it just breaks up and crap filters that come with it 🙈
@UrbanVanlife
@UrbanVanlife 2 года назад
corrrect fit , NOT supply . over to you smart arse
@nickpritch3152
@nickpritch3152 2 года назад
@@UrbanVanlife not a smart arse Neil just saying and no decent pick up pipe in tank lol you carry on guys you seem to know what your doing lmao anybody else think it's shit pipe and fish tank pipe just pushed into sender unit lmao 🤣
@nickpritch3152
@nickpritch3152 2 года назад
Fuel pipe eberspacher d2 is hard plastic 4mm outer bore 1.5mm inside diameter over to you smart arse 👌
@UrbanVanlife
@UrbanVanlife 2 года назад
@@nickpritch3152 just pointing out it’s not an eberspacher but you would know that if you had fitted one which I’m guessing you haven’t . I’m no expert but I’m certainly not a Google expert . END OF CONVERSATION BABE !
@nickpritch3152
@nickpritch3152 2 года назад
Neil I've fitted a few ....there a knock-off eberspacher . ok the controller's different but they are .got another two in garage waiting tobe fitted .I GET it YOUR EMBARRASSED AT SHOWING THE WORLD YOUR NOT THE GURU YOU THOUGHT YOU WERE.JUST GOGGLE CORRECT PIPE AND FIT IT WITH A PROPER STAND PIPE OUT OF TANK A DECENT FILTER AND FILTERS ARE DIRECTIONAL THE SIDE THAT HOLDS THE MOST FUEL GOES TANK END .THERE'S SO MANY PEOPLE NOT JUST ME TELLING YOU . I really don't want to get in to a slanging match with you .BUT JUST FIT IT RIGHT FOR POOR WILL OR YOU'LL BE GOING BACK TO IT.IVE WORKED ON ENOUGH TRUCKS TO KNOW THAT DIESAL BREAK'S DOWN SHIT PIPE .KEEP UP THE GOOD WORK WE ALL THE BANTERING ,HAVE A NICE DAY 👍
@Scud_and_thesTig
@Scud_and_thesTig 2 года назад
Clickbait… tune in for Diesel Heater fitting Part 2 😂😂😂 Good video.. excellent music too 👍💙❤️
@yetanotherone...1814
@yetanotherone...1814 Год назад
Screw on or screw up the diesel heater? Screw up a Freudian slip? lol Really enjoyable series.
@matthewdavies7431
@matthewdavies7431 2 года назад
Fitted and used a few 2kw myself. Perfect. Again as mentioned I don't think the fuel filter is the correct direction
@richardmillican7733
@richardmillican7733 2 года назад
Fitted several of these, I even have 2 in my van! I run mine on red diesel from the supplied tank. Had a few issues from time to time, but can usually fit one from scratch inside a couple of hours!
@hollandduck79
@hollandduck79 2 года назад
I've seen more install videos where the fuel pump malfunctions . thanks for the video Will
@jonclassical2024
@jonclassical2024 2 года назад
Oh no Bo, recommend the Eberspacher Espar Airtronic D2 Air Heater 12v Diesel with Digital EasyStart Select Controller and Exhaust Silencer Muffler work really well...just say'n.
@offgridtbone2162
@offgridtbone2162 2 года назад
Mate, I have got a 2kw in a lwb ducato and it's fantastic . My van was 4 degrees the other day and in about an hour of having it on it was 24 degrees and the beauty of it is you can turn it down and it will maintain temperature beautifully and I'm guessing it will be more fuel efficient. I wouldn't replace it for a 5kw. I have had zero issues in 2 years . That 5kw in that van is going to be toasty too quick . You would be turning it off and on all the time. I'd consider keeping it. Good luck
@peterlori36
@peterlori36 2 года назад
never mind. you will get it right next time. frustrating as it seems. try the fuel line change option. i have the heater under the passenger seat. on ford transit custom. works well. no problem yet. dont give up its all a learning curve. stay safe .
@Pipboy83
@Pipboy83 2 года назад
Just a bump in the road Will, you will get there eventually. Keep your head up laa
@nickpritch3152
@nickpritch3152 2 года назад
Will Neil is it a 2kw or 5 KW heater pump settings all wrong on controller . Anyway I've had more issues with 5 KW sooting up because there to big for small vans and yr always running them on low so they never burn hot enough to keep the burn chamber clean .ebspach are 2,2 and that's all they ever fit in trucks and never have problems with them because they run full chat all it's life I've run a number of 2kw Chinese in vans in my opinion the best no problems ever . 5kw and ⁸8kw all the 8kw is a5kw over fuelling to burn hotter it's only my opinion mind keep up the good work boys I'm subscriber. To both your channels 👌👌👌
@UrbanVanlife
@UrbanVanlife 2 года назад
Could be plus settings
@suzybeetravels
@suzybeetravels 2 года назад
Watched our friend fit one the other week to his T4. It was a bugger to bleed BUT it works. Hope you get it sorted.
@the_crafty_fishers7507
@the_crafty_fishers7507 2 года назад
I’ve fitted a 2kw in my transit and had no problem it had different fuel line to that and it’s in its own tank and I’ve got the filter the other way round I’ve just brought a 5kw for the new crafter build fingers crossed I have no problem with that one 😬 good luck with yours mate
@iansworkshop
@iansworkshop 2 года назад
I'm surprised Neil didn't swap his pump on to yours to eliminate the faulty fuel pump , I've just had my heater delivered today, fingers crossed I don't have your luck , lol, cheers will as always great video👍
@alessia0064
@alessia0064 2 года назад
So sorry things didn't go to plan and yes Neil's impression of you was pretty accurate 🤣🤣 but we wouldn't want you any other way 😊👍.
@campervanzoso
@campervanzoso 2 года назад
Have had a 2kw fitted for 4 years now, no problems. And have fitted another 3 to two vans and a boat. The heaters are really basic so can't see much going wrong as long as the fan isn't jammed. Did you try disconnecting fuel line from heater and seeing if the pump would pump into a container.?
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Yep we tried all of this, think I need to replace the green pipe
@BuiltnotBoughtCampers
@BuiltnotBoughtCampers 2 года назад
Hi Will, i know i have already spoke to you, after watching this video, and an FYI, I fitted a 2 KW heater in a Renault Espace and had the exact same error codes and I mean, identical. One other thing, Neil's Bear onesie, lol, absolutely love it.
@baldvale5418
@baldvale5418 2 года назад
Hi Will, loved the video as always. I know what the Heater problem is........................you need to pour the Deisel over it and set the B4stard on fire ; )
@WillsWhereabouts
@WillsWhereabouts 2 года назад
😂😂😂 I hope this works
@baldvale5418
@baldvale5418 2 года назад
@@WillsWhereabouts 😂 should make a great video 👍
@john-ec6sy
@john-ec6sy 2 года назад
fuel filter was the wrong way around, the green hose is known for causing aggro so best to change it for the hard nylon stuff, youll also need the slightly bigger black fuel line and jubilees for connecting it all together. these heaters can be a pain. i have 2 2kws both working but have had teething problems getting them going. it did look like air was entering the fuel filter somehow. you should see air bubbles (cavitation from pump) after the pump but not before it. i connected everything up apart from the pump and gravity primed my lines then quickly inserted the pump in the fuel line where it should be without losing too much fuel. id look at changing the fuel pickup on the sender unit for a proper metal pipe. these can be a pain but worth it when u get there in the end. hope you get it sorted
@Flash685.
@Flash685. 2 года назад
Nice to finally meet someone who has the same luck...if it can go wrong it will happen to you! However, silver linings and all that, that was a banging playlist of tunes on the way up!
@operativethisistheway6384
@operativethisistheway6384 2 года назад
I couldn't make out what was the last song
@Flash685.
@Flash685. 2 года назад
@@operativethisistheway6384 Usher “love in this club”
@hughjasse3375
@hughjasse3375 2 года назад
The fault most report is E8 - lack of fuel - usually because the filter isn't primed, and it times out pumping fuel - then E10 (multiple faults), if it tries a few times pumping fuel, but still hasn't loaded. Filling the filter with a syringe is a good idea, as if you keep running the pump too many times, the pump will wear out eventually, before it is fully lubricated. A long stretch of fuel line doesn't help - keeping it as short as possible reduces required work/pressure. Those pumps are pretty cheap, and are bare metal on metal inside. The quality, expensive, super quiet ones cost as much as the whole heater again! But as you discounted that, may be the heater itself. I have the same 2K and it worked first time, been running trouble free a few years. You may have just been unlucky. If you got it on Ebay/Amazon. make sure you don't go past the returns date.
@ILikeThatchannel
@ILikeThatchannel 2 года назад
Love your videos will, never fail to have me in stitches. I to will be fitting a diesel heater next year and you showed they can be tricky , so I will brush up on the learning cheers
@adrianwellington7096
@adrianwellington7096 2 года назад
Cheers mate I am learning heaps here, as a kiwi in lockdown in the Philippines i will be doing such a build when back in NZ . One small difference I am a Paraplegic . Keep rockin.
@rossfender6411
@rossfender6411 2 года назад
I fit these on boats all the time… e08 can also be low power to the fuel pump ( if the cables your run to the battery are to thin that can give you that error
@h.bsfaithfulservant4136
@h.bsfaithfulservant4136 2 года назад
Hahaha… Neil doing the best impersonation of Will I’m ever likely to hear 🤣👍. That’s a damn shame about the diesel heater Will 😖… and I hope when you finally get it sorted that you’ll be able to sleep through the noise it makes 🙏
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Haha so do I
@anserkhan9430
@anserkhan9430 2 года назад
Bro forget the heater...them trousers your friend is wearing I'm sure I saw them worn by an Eskimo on the discovery channel 😆!!! Stay blessed people 🙏. Its all ❤!!!!
@Lou_Sylw_Bulgarian_Rescue_Dogs
@Lou_Sylw_Bulgarian_Rescue_Dogs 2 года назад
I second what a couple have said in the comments. Try another power supply. When you first turn it on it demands alot of power. After its running it doesn't use that much. Nightmare in the winter without one. We are in Poland now and its -14. Without the heater we would be screwed. Ps. Change your fuel line to a nylon one as others have mentioned 👍
@timgrossmann5898
@timgrossmann5898 2 года назад
North woods Tim; I feel your pain brother. I've had more than my share of projects like that. Frustrating as all get out. That's why God gave us alcohol. Keep on truking.
@refillsontheroad7511
@refillsontheroad7511 2 года назад
Another vote for trying a different power source or checking the voltage on your battery - my heater would start up for a minute and then crash because the battery voltage wasn’t high enough
@adamsher86
@adamsher86 2 года назад
Another good vlog Will and funny too. Am liking your channel and seeing how to convert a van similar to mine. Good to see Neil promoting Daz's channel from The Urban Motorhome too with his hat! Pity your heater didn't work. Keep up the good work!!
@jobell7356
@jobell7356 2 года назад
well done to you two, your patience is amazing!! Good luck the second time
@adampugh3493
@adampugh3493 2 года назад
I had the same issue with code e-07 keep stopping the heater. Changed the control panel and it solved the issue.
@Alivefrom45
@Alivefrom45 2 года назад
Only you Will could end up buying a broken diesel heater, at least you should be able to switch out the faulty unit for the new one on you own. Well done Neil for helping Will.
@Scottishebikeadventures
@Scottishebikeadventures 2 года назад
Will those green fuel lines are prone to air-locking. Everyone recommends ditching it for the white. I have the all in one heater unit and mines air-locked. I ripped the green pipe out and replaced it. So far so good. ATB Martin
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Awesome will give this a try
@Scottishebikeadventures
@Scottishebikeadventures 2 года назад
@@WillsWhereabouts good luck 👍
@njp2k914
@njp2k914 2 года назад
Neils impression of you is spot on
@keepitreal3453
@keepitreal3453 2 года назад
Hi mate just some advice. You need better fuel line and that will do the trick 100% or I will pay for your next heater for you mate . Good look keep me informed . Buy harder fuel line because them ones you've got will just suck in on them selves when fuel being pulled through.
@charleswillard775
@charleswillard775 2 года назад
They work great eventually. Just gotta sort the noise lol
@RustyCandyAdventures
@RustyCandyAdventures 2 года назад
I got my air intake. The plastic hosing I used a step drill and put more holes in it and fitted a sock. Then the hose is grey water hose. It's bigger. I found a fitting on heater.
@Quickblood1
@Quickblood1 2 года назад
Always bench test everything. I got lucky with my diesel heater and stupidly didn't test it before installing but I did test my Maxfann, imagine finding out that was faulty after installation. 😮 I bought the 2KW no issues as was told the 5KW was too much for a small van.
@elldees4071
@elldees4071 2 года назад
Will, I feel your pain I’m having issues with E-03, changed glow plug and still the same.
@WillsWhereabouts
@WillsWhereabouts 2 года назад
They seem to be troublesome
@elldees4071
@elldees4071 2 года назад
@@WillsWhereabouts for sure, I think my plan of attack is to disconnect heater fuse for 3 mins and disconnect the LCD control panel and use jump leads and see how it goes then.
@goody390
@goody390 2 года назад
A you should have used a stand pipe to go into the sender B change the fuel line as that green one is crap C get rid of that filter as well its not needed I have run my heater for years without one remove it !!
@llorylloyd
@llorylloyd 2 года назад
Hilarious video as usual. Aye your videos are so loud. I turn down the volume - so much noise. Then turn it up to hear you speak. Yes Will, Neil got you on spot. 🤣 Neil loved the cuddle ears on your onesie.
@nickpritch3152
@nickpritch3152 2 года назад
Goggle Chinese diesel air heater part 11 fuel delivery he explains it quite well 👍
@tyranneous
@tyranneous 2 года назад
Great video... But, word of warning... Diesel pumps pump diesel. They don't suck air - or at least, they're very bad at it. The other thing is that typically, a diesel pump will be designed to be lubricated by the diesel they're pumping, so if you're pumping air then the pump isn't being lubricated. This means that running it for any length of time will damage the pump, and it won't pump properly - or enough - any more. As such the line between the tank and the pump should be as short as possible, and ideally below the fuel line in the tank, that way the line before the pump, even after not running for a while, will remain filled with diesel for the next time it starts. Evidence for what I've said: vehicles have in-tank lift pumps for this reason - the inlet of which is always submerged. Worth bearing in mind when you fit the next upgrade!
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Awesome thanks for the advice I’ll make sure to remember this for the re-attempt
@tyranneous
@tyranneous 2 года назад
@@WillsWhereabouts You'll smash it mate - one thing I know from watching your videos is that it doesn't matter that there's bumps along the way, you get it all sorted and properly pukka in the end. Keep it up with the great energy!
@mariemarshall5082
@mariemarshall5082 2 года назад
Sorry the heater didn’t work, don’t despair you’ll get there, loved the deleted scenes at the end so funny x
@justincurrie2102
@justincurrie2102 2 года назад
You could have drilled through the breather tube directly on the sender unit. Saves taking out the sender unit.
@FredasAdventures
@FredasAdventures 2 года назад
exactly what i did
@michaelstevens9394
@michaelstevens9394 2 года назад
Me too, easier ,no special tools reqd
@UrbanVanlife
@UrbanVanlife 2 года назад
We found this out later on
@chris20years1
@chris20years1 2 года назад
You get technical hitches but you can fix them and loving these videos
@RustyCandyAdventures
@RustyCandyAdventures 2 года назад
The pump is not designed to suck. It needs to be close to tank. It can push. The exhaust I fitted a copper elbow which increased size then on pipe. Just fitted silencer. You might need bigger pipe.
@lindalawrie148
@lindalawrie148 2 года назад
I understood rhe accent. Not bad for a South African.
@El-Tel63-Terry.
@El-Tel63-Terry. 2 года назад
Normally I'd say never trust a man wearing a Lion? Possibly a bear? Onesie... Unless of course he's Neil from Urban Vanlife from Liverpool ! 😂😂
@UrbanVanlife
@UrbanVanlife 2 года назад
not allwasy true
@El-Tel63-Terry.
@El-Tel63-Terry. 2 года назад
@@UrbanVanlife Ha ! 😉👍🏻
@johnphilip6609
@johnphilip6609 2 года назад
Great videos, always enjoy watching yours. Hope you get your heater sorted asap 👍
@NorthernersonTour
@NorthernersonTour 2 года назад
Hi Will, Mark here. Did you try the pump pulse rate as I noticed at the end you had it set to 35 degrees meaning fuel supply demand is likely more than the pump pulse rate can provide.
@UrbanVanlife
@UrbanVanlife 2 года назад
having it on the highest temp just means the unit will continue until the internal temp of the van reaches 35,deg . the only difference with pulce is your slowing down the pump rate and , its technically both the same but not the same , but ultimately dose the same thing , high pulce and high temp just means the units going to run on full and vice versa for lowinging pulse and temp
@joemckigen4065
@joemckigen4065 2 года назад
You should have got a professional in like Dan from the travel trolls lol
@catherineferguson7388
@catherineferguson7388 2 года назад
Hi Will, Neil is so funny, he cracks me up, I’m loving it that your van is coming together Will, it’s a shame the diesel heater was faulty, that would be my bad luck too. At least you can laugh about it. Thanks Will, your an awesome guy, love the content. Xx🚐✌️🤟🏼
@martinrandall5836
@martinrandall5836 2 года назад
Hi Will and Neil, the channel Mel’s big van small world?, just swapped out a 5Kw heater for a 2Kw heater because he found it was to hot, why he didn’t just turn the thermostat down I don’t know. He did find something of interest , there was evidence on the mounting plate of soot at the exhaust port so used exhaust putty to give a good seal when he reinstalled the heater. Will, you could always sleep over at Charlie and Lauren’s van as their heater works just fine, or have I just cursed that for them? Hope all goes well with the replacement heater.
@vandemon1822
@vandemon1822 2 года назад
Will I have heard that the 2 kw heater Does give problems a 2 kw heater is the same price as a 5kw however I've heard you need to go into the settings on the controller and change some settings as the controller is set up for 5kw one's Good luck with that one
@aureltanasan1413
@aureltanasan1413 2 года назад
Change the glow plug, I had this on a new heater, drove me mad 3days trying various things. I took a plug of a known working heater, and hay presto, it fired up and still working over two years later. Change the glow plug and it will fire up.
@moe_1886
@moe_1886 2 года назад
Maybe just get back on to the 12v electric blanket Will? 🤭
@angusrobinson7032
@angusrobinson7032 2 года назад
Unfortunately loads of things contributing to it not working and if it does work the efficiency will be poor. The filter is backwards, the pumps are great at pushing but not at sucking so best to install it as close to the tank as possible. The chinese units are copies of the eberspacher/webasto ones but the chinese pumps lack the built in filter, so theyre best mounted straight vertical with inlet at the bottom to prevent air bubbles blocking diesel from lubricating one side of the valve constantly, if not vertically, at least close to, and definiteely not horizontally. As for people suggesting the white skinnier fuel lines, they're best to run from the pump to the heater, but its best to have the larger line running from tank to pump so there's no resistance limiting the pumps supply. I also suggest getting another section of exhaust tubing and using it as your inlet pipe, much stronger and wont collapse and block the air intake if a rock hits it while driving and cause the heater to fail on next use. Ideally exhaust pointing to the rear also, no more than 90deg bend and no low spots without drain holes or condensation/rain will block it. Learnt most of this from John Mck 47 on his channel, no one knows more about diesel heaters! some tips are just common sense. Cheers!
@p24hrsmith
@p24hrsmith 2 года назад
I've had these codes and what you do is turn the heater over and just between the inlet and exhaust you hit it really hard with a ruddy big sledgehammer 🔨⚒️🔨
@paulcalvert5735
@paulcalvert5735 2 года назад
Well that looks like a lot of work hope the fuel doesn’t freeze when it’s cold.
@mattpierceplayz
@mattpierceplayz 2 года назад
Daft comment time, are you worried about the pipe running from the sender unit (under the van) getting damaged? Should you run it through some flexy conduit to protect it?
@SuperOMARKO
@SuperOMARKO 2 года назад
He said its a cable so it should be ok..
@toddv6411
@toddv6411 2 года назад
Hi, that pump only pumps .02ml per stroke (click) ... AND relies on diesel for lubrication. So, running it dry for so long trying to suck fuel through that long feed ... not doing the pump any favors. Always draw fuel through the line to the pump suction side before running the pump. Cheers.
@PK_Blinder
@PK_Blinder 2 года назад
At least I know Will will be as cold as me without a fitted diesel heater.... 🤔🤭😉
@josenicolau2349
@josenicolau2349 2 года назад
Ouch, tuff luck on the unit then 😔 hope the next one comes ok, or else, there's a simple solution, just keep traveling south instead of north 😂😂 Cheers, Krak, Portugal
@martinrees5690
@martinrees5690 2 года назад
I put a 2kw heater in mine for the 1st year i had my van and it was a nightmare, had nothing but problems, upgraded to 5kw and never had an issue
@Thebritishbarnacle
@Thebritishbarnacle 2 года назад
There's nothing worse than sending faulty items back especially when you've spent hours trying to solve it. I was fecked off sending a Bluetooth speaker back coz it didn't pair with the other wireless speaker 😂😂😂 can't imagine how you feel. Good luck Will hope you sort it
@dickiemcnutsack3248
@dickiemcnutsack3248 2 года назад
Not the trusty Berghaus 😱🤣
@thomashaining6171
@thomashaining6171 2 года назад
Enter code 1688 to enter hidden menu and adjust the fuel pump HZ also change the fuel pipe to 4mm hard nylon typ, burner relys on the fuel squirt to burn
@UrbanVanlife
@UrbanVanlife 2 года назад
We hate it when you leave .but I still smell of Deisel lol
@WillsWhereabouts
@WillsWhereabouts 2 года назад
Haha so do I
@weaksyweak
@weaksyweak 2 года назад
Great stuff - a UK version of Mav
@deirdre444
@deirdre444 11 месяцев назад
You can sing! Nice!
@SenneVandeSompel
@SenneVandeSompel 2 года назад
I have a 2kW diesel heater and works perfectly
Далее
SIGMA ENVY IS UNTOUCHABLE 🔥 #insideout2
00:10
Просмотров 1,4 млн
🎙А не СПЕТЬ ли мне ПЕСНЮ?
3:09:39
Просмотров 1,6 млн
VAN BUILD NEVER ENDS! No Experience Van Build
20:44
Просмотров 65 тыс.
STEALTH VAN CAMPING - Life On The Road Alone
20:32
Просмотров 438 тыс.
Foam Bones Van Build System Vol. 1
50:18
Просмотров 905 тыс.