Тёмный
No video :(

DPM and DPC detail for extensions 

Izzy the Bricky
Подписаться 33 тыс.
Просмотров 74 тыс.
50% 1

DPC and DPC detail for extensions
this is how our inspector likes us to do this detail, other inspectors/sites might vary
thought this would be a helpful video though

Опубликовано:

 

26 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 56   
@hassanibrahim8687
@hassanibrahim8687 Год назад
Answered 4 of my questions on one video.. loved the diagram also. helped visualise it better.
@IzzytheBricky
@IzzytheBricky Год назад
Thanks very much mate, glad you found it helpful 🙂
@fredericknicofabian6931
@fredericknicofabian6931 2 года назад
This is a very informative and easy to digest video. I also like that it is short
@brickrightbuildinglandscaping
@brickrightbuildinglandscaping 3 года назад
Great video. We have radon here as you say every area is different. OUR DPM goes straight through the cavity two courses lower that dpc on the external skin which forms a complete seal between floor and cavity. Dpc is then the usual 4 inch and we add weep holes so any water dont sit on the tray . Every area is different great detailed video. Justin brickright 👍
@IzzytheBricky
@IzzytheBricky 3 года назад
Aah that's interesting how your DPM is. Even in Derbyshire I've found different inspectors like different things..just depends like you say buddy! Glad you liked this little video, thought it might be helpful for some people who dont often see the dpm in. Hope your not getting too wet today buddy!😂😄
@brickrightbuildinglandscaping
@brickrightbuildinglandscaping 3 года назад
@@IzzytheBricky Off on hols at mo in the rain typical UK mate .Interesting how different areas different practices. Most bricklayers like to build brick then block for obvious reasons bug here in wales we always use celotex in the cavities so always block first harder to out your brickwork but i think celotex with a clear 50mm free cavity is better than cavities filled with batts . Anyway great insight to our world great videos keep em coming Justin 👍
@biancaa408
@biancaa408 28 дней назад
Thank you so much!
@JimJimpmjj
@JimJimpmjj 3 года назад
Brilliant information, found that very helpful and informative thanks 👍💪
@IzzytheBricky
@IzzytheBricky 3 года назад
No worries buddy! Glad it helped you.
@SporeZSporeZ
@SporeZSporeZ Год назад
Please do more educational videos please bro 🙏🏽 also love your videos, really helps for a youngen loke me who has jusy finished there NVQ Level 2 in Bricklaying
@michaelwhite28
@michaelwhite28 3 года назад
Really helpful info, much appreciated
@IzzytheBricky
@IzzytheBricky 3 года назад
Glad it was helpful Michael 🙂
@m.harris9512
@m.harris9512 3 года назад
Very helpful! I like these kind of tips.
@IzzytheBricky
@IzzytheBricky 3 года назад
Thanks buddy, glad it was helpful:)
@russellfreestone8580
@russellfreestone8580 11 месяцев назад
Very interesting. To all the regs and everyone does the same but it seems madness that its a balance up on slipy plastic.
@rubblestacker
@rubblestacker Год назад
I remember 10 odd years back having to play origami with the red radon barrier, it was a nightmare to stick (with said radon tape) then a couple of yrs later they decided radon was not in area so we didn't have to use it any longer lol , I lke the way building regs change every year but modern houses are still shit , small the only thing better is insulation, altho new regs this yr on about keeping them cool in summer lol , old ones built with no regs seem to last longer ,look nicer too.
@NatalieBushby
@NatalieBushby 6 месяцев назад
Should the dpc not be sealed to the gas barrier to stop a slip plane? Water could get in between 2 heavy membranes?
@homersimpson5501
@homersimpson5501 2 месяца назад
Excuse my ignorance but why is there a gap between the walls?
@mrboyban
@mrboyban Год назад
Hey mate, do you need to fill the cavity with concrete under dpc?
@gavsmith2106
@gavsmith2106 2 года назад
Seen people do this before and had to go back to remove it as water can be carried inside due to bridging the cavity at dpc level. If it was lower then fair enough but anything at dpc level or above bridging the cavity is a recipe for disaster.
@paulcollins6221
@paulcollins6221 2 года назад
Well said mate this izzy aint got a clue water going to track across the cavity his building inspector needs to go back to college
@BerkleyBuilds
@BerkleyBuilds Год назад
I think you’ll find that if water tracks through the DPC something else has gone wrong or isn’t correct. If the exterior ground level is correctly installed 150mm below DPC as stated in Approved Document C of the building regulations then no water will be able to track across. Izzy is correct in saying the radon barrier bridges the cavity as this is a standard radon detail however, the radon barrier should be continuous or at minimum lapped by 300mm and taped with radon tape. Ben
@TheTraditionalGolfer
@TheTraditionalGolfer 3 года назад
We have 1 dpm sat on top of our hard-core and sand blinding that thr concrete goes on and it flies over both internal and external skins to form a radon tight barrier. Then we have a 4 inch dpc and a 18 dpc tray straight on at first course with weep holes.
@dalemalpas4960
@dalemalpas4960 3 года назад
Same in Northamptonshire 👍
@jamesdiver2183
@jamesdiver2183 3 месяца назад
my joiner drilled through a dpc and a dpm to fix down a wall plate on top of 150 block am I going to have a problem in the future
@IzzytheBricky
@IzzytheBricky 3 месяца назад
Hi mate, no problem there ☺️
@andrewpalij4691
@andrewpalij4691 3 года назад
Thats how I do it but we don't have any Radon in our area👍
@kingofthetrowel1725
@kingofthetrowel1725 2 года назад
Izzy do you tape your dpcs together on the bed joint or just leave lapped 🤔 seen loads of different ways of doin it just wondered your preferred method, seen lads running silicone ct1 all on the bed to seal the two together and seen others just thin bed with gear and other use the good old vis queen tape lol good video mate 👍 new sub 😊
@IzzytheBricky
@IzzytheBricky 2 года назад
Ayup mate! Thanks for subscribing fella! We tape the DPC to the DPM. The dpc usually has a good 300mm overlap on the dpm and then its taped :) to be fair..anyway is pretty good👌😁 Hope your having a good weekend fella🍻🍻
@kingofthetrowel1725
@kingofthetrowel1725 2 года назад
@@IzzytheBricky nice one mate 👍👍 cheers
@BerkleyBuilds
@BerkleyBuilds Год назад
As a building inspector may I just add that you’re correct to lap any joints by 300mm however, you should also tape this with a radon tape. Essentially it works like double sided tape but the critical thing is it forms a gas barrier preventing any gas penetration into the property. Ben
@kingofthetrowel1725
@kingofthetrowel1725 Год назад
@@BerkleyBuilds yes I understand that., but when using the tape to tape dpc tray to radon barrier and the tape runs all the way along the bed joint (of the outside skin) is this acceptable as in theory your walling on top of a squishy tape
@BerkleyBuilds
@BerkleyBuilds Год назад
@@kingofthetrowel1725 you don’t need to tape the DPC tray to the radon barrier because the radon barrier has already formed the gas seal. You’ll have 3 layers of plastic, first layer is your 1200g DPM to form the radon barrier that comes over the sand blinding up the block and over the cavity, second layer will be your cavity tray and third is your 4 inch DPC. You only need to lap and tape joints in the first layer if one sheet is too small, where possible limit joins. Hope that answers your question.
@lesleywillis6177
@lesleywillis6177 4 месяца назад
01:32. Good to hear you get no damp in this arse!😂
@adizarabiu8185
@adizarabiu8185 2 года назад
Please where can one buy the dmp sheet from.
@IzzytheBricky
@IzzytheBricky 2 года назад
Any building merchants
@foundthetruth2003
@foundthetruth2003 7 месяцев назад
Is it me or does it look like over kill?
@Chris-ik2tw
@Chris-ik2tw Год назад
Izzy you av North Derbyshire accent where u live matey. I'm south Chesterfield I'm avid Watchet your channel
@IzzytheBricky
@IzzytheBricky Год назад
Hiya mate! I'm Belper way buddy ☺️
@IzzytheBricky
@IzzytheBricky Год назад
Thanks so much for the support
@paulcollins6221
@paulcollins6221 2 года назад
Bad building inspectors wind driven rain will saturate an external wall and water will rundown the inside did you do a proper apprenticeship
@IzzytheBricky
@IzzytheBricky 2 года назад
There are TWO...TWO DPCs. Number ONE. Raydon Barrier. This is the DPC you keep referring to "bridging the cavity" is the RB. This is bedded on both the external brick and internal blockwork at the same FFL hight...So, in one respect, your quite right to raise concerns about bridging the cavity and the other comments you made. These comments would be totally true if I were to only have this one DPC detail in. HOWEVER. Number TWO The 2nd DPC; is sitting on top of the first Dpc (overlapping it) on the external Brickwork and then..goes 225m up onto the first block laid ABOVE FFL. Therefore. The first DPC which is "bridging the Cavity" is totally irrelevant in reference to damp and moisture. As the SECOND DPC is doing all the work and protecting the building from penitential Damp and raising damp. How can moisture cross the cavity when moisture cannot even get into the tray detai created, as the 2nd DPC overlaps the first? Regardless of the detail, I've yet to have an issue, or even have any concerns raised by the multitude of inspectors used over the years, nor NHBC when working on multiple sites. A thing I like to remind myself if that houses use to be built without all these DPCs and precautions all the time. As you well know. They rarely have any issues with damp and moisture. Cheers fella
@paulcollins6221
@paulcollins6221 2 года назад
Your bridging the cavity
@haydnbrewer7426
@haydnbrewer7426 2 года назад
Once it’s concreted and dried they will trim back the membrane
@paulcollins6221
@paulcollins6221 2 года назад
You ballsed that up bridged the cavity Your dpc polythene should go above inside wall then down and out three courses under
@IzzytheBricky
@IzzytheBricky 2 года назад
Been doing this last 10 years on sites and on all privates. Never had an issue or been told to do it any other way by all of the inspectors over the years. That Dpc goes on top of the fist internal block and then down and out 3 course
@IzzytheBricky
@IzzytheBricky 2 года назад
Also the first Dpc bridging the cavity is a Radon barrier.☺️ just the way we've been told to do it mate. As I said, all over the country inspectors want or expect different Dpc details, as you probably know☺️👍 Hope your well mate
@paulcollins6221
@paulcollins6221 2 года назад
Water is going to run down inside of outer skin hit the dpc run across the dpc to inner skin common sense
@IzzytheBricky
@IzzytheBricky 2 года назад
Is there a hosepipe in the cavity 😂😂😂😂
@mrboyban
@mrboyban 11 месяцев назад
lol@@IzzytheBricky
@paulcollins6221
@paulcollins6221 2 года назад
Other reader's do not copy this example its bad workmanship
@IzzytheBricky
@IzzytheBricky 2 года назад
😂😂😂 you still going on mate
@paulcollins6221
@paulcollins6221 2 года назад
Yes you dont Bridge a cavity
@ymac7245
@ymac7245 10 месяцев назад
1:30 did you just say "so we get no damp in this arse"? 🫢
Далее
Bricklaying- Blockwork and DPM detail
10:44
Просмотров 24 тыс.
Ajdarlar...😅 QVZ 2024
00:39
Просмотров 267 тыс.
What Are Cavity Trays & Where Are They Used?
12:11
Просмотров 189 тыс.
Bricklaying Extension: upto DPC part 2
9:54
Просмотров 144 тыс.
Say Goodbye to Rising Damp - A Simple Solution!
8:21
Просмотров 598 тыс.
Bricklaying Guide -How To do a Cavity Tray Over Lintel
10:54
Ground Floors HQ
26:41
Просмотров 99 тыс.
Plasterboard HACK | Every DIY'er Should Know
11:29
Просмотров 557 тыс.
How to fit cavity closers for windows and doors
3:45