HI GUYS IN THIS VIDEO I HAVE EXPLAIN ABOUT DUAL PUMP MOTOR AUTOMATIC ON/OFF ALTERNATE RUN OPERATION FOR THREE PHASE MOTOR SO THAT YOU CAN TURN ON YOUR WATER PUMP ALTERNATE AUTOMATICALLY RUN BY USING PULSE RELAY.
HERE I HAVE USE SOME MORE USEFUL COMPONENTS LIKE AS:
1. MINIATURE CIRCUIT BREAKER (MCB)
2. MAGNETIC CONTACTOR
3. OVERLOAD RELAY (OLR)
4. SELECTOR SWITCH ON/OFF
5. PILOT LIGHT SIGNAL INDICATOR LIGHT LAMP
6. FLOAT SWITCH
7. PULSE RELAY
IT’S VERY USEFUL CIRCUIT AND YOU CAN MAKE AND PREPARE VERY EASILY.
#DUALPUMPMOTORAUTOMATICONOFF
#JOHNWICKDSTIII
#GodisGoodAlltheTime

Опубликовано:

 

17 май 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 9   
@EhtishamAkhtar-pf6ne
@EhtishamAkhtar-pf6ne 11 месяцев назад
Great job
@rh0meo
@rh0meo 2 года назад
Magaling sir, malinaw ang diagram, paano kung mag lagay ng pressure switch sa diagram nayan at may selector na manual at auto, sana gawa tutorial
@johnwickdstiii3679
@johnwickdstiii3679 2 года назад
Salamat po sir,. Copy paste po sir ng mga images or idownload po yung mga gusto mo na pics po sir sa google 😅
@arielcunanan4994
@arielcunanan4994 Год назад
Gagana cya pero gumamit ka pressure switch yung normally closed contact
@arielcunanan4994
@arielcunanan4994 Год назад
Pwedi rin sa manual and auto gumamit ka relay 14 pins 2 pieces
@arielcunanan4994
@arielcunanan4994 Год назад
Mass ok payan kung lagyan mo trip activation kapag nagtrip motor 1 mo automatic aandar motor 2 ganon din sa motor 2 pag ngtrip andar din motor 1
@ibnmasoud1682
@ibnmasoud1682 Год назад
wrong wiring in pulse relay.. there is same phase in the coil, please correct it.
@emmanuelmweti8426
@emmanuelmweti8426 Год назад
The other side of the lamps are connected to Neutral. still wrong there...
@emmanuelmweti8426
@emmanuelmweti8426 Год назад
Please pull down that video. its wrong, its wrong it will mislead a lot of new folks. L2 in the schematics refers to Neutral and not phase wire. in most cases if not all cases the A2 of the contactor is connected to neutral..
Далее
Basic Motor Controls Explained
14:01
Просмотров 164 тыс.
İranda azərbaycanlı prezident seçilib
00:32
Просмотров 279 тыс.
Еду за гитарой…
01:00
Просмотров 322 тыс.
POLI зовет Газана
00:12
Просмотров 633 тыс.
Three-Phase Power Explained
9:58
Просмотров 1,3 млн
Motor Control 101
15:59
Просмотров 1,9 млн
Relays Load Alternator - duplex relay How it works
12:32