Earthing and bonding part 1: what are main and equipotential bonding conductors 

Pure Electrical Training - by Adrian Davey
Подписаться 11 тыс.
Просмотров 11 тыс.
50% 1

Hello and welcome to this video on earthing and bonding part 1 of 3.
In this video, I talk you through a couple of regulations that you need to consider, the definitions you need to know, and how the equipotential system works by creating a faraday cage effect.
Part 2 of this video will talk you through testing continuity and using test method 2.
Part 3 covers fault finding.
As always, please like share, and subscribe so others can learn from these videos too.
Take care
Adrian

Опубликовано:

 

23 дек 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 24   
@TheFella172
@TheFella172 Год назад
Brilliant video, really helpful and a clear delivery of how and why Bonding and CPC's are used. Well done Adrian.
@michaelcox4081
@michaelcox4081 Год назад
Very good video dude. Clear, concise and easy to understand. Also I think your disclaimer at the beginning hits the nail on the head.
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 🤗 I get mixed reviews of the disclaimer, but I think the training industry lets people down and someone needs to say something
@JShamaal
@JShamaal 2 месяца назад
Thanks for your great videos. Well explained.
@Pure_electrical_training
@Pure_electrical_training 2 месяца назад
Glad you like them!
@Rossisearle
@Rossisearle Год назад
Great video... Keep up good work
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you for taking the time to give me feedback 🤝
@Rossisearle
@Rossisearle Год назад
@@Pure_electrical_training it's well deserved mate..
@munafmufc01
@munafmufc01 Год назад
Brilliant explanation
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 🙏
@matthewfewings6023
@matthewfewings6023 Год назад
Great video 😊
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you Matthew 🙏
@ollyburt6477
@ollyburt6477 Год назад
Lovely vid 👍🏼
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 🙏
@arayated5608
@arayated5608 Год назад
Legend
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 🙏
@michaelcostello6991
@michaelcostello6991 11 месяцев назад
If the plastic pipe comes out of ground and changes to copper in house, then does it need to be bonded. ?? I mean it could become live if an electrical fault occurs..
@Pure_electrical_training
@Pure_electrical_training 11 месяцев назад
No, it does not need to be bonded as it does not go into the ground (zero potential). In this instance, the circuit protective conductor of the appliance will be sufficient
@michaelcostello6991
@michaelcostello6991 11 месяцев назад
I watched another video where a chap suggested a faulty solenoid on a pipe could make the pipe live. Bit scary if the pipe could be sitting there at 230V . Of course with RCD protection one should not get killed if they touch it, but if it was bonded it might be safer ? What are your thoughts on this type of scenario.
@michaelcostello6991
@michaelcostello6991 11 месяцев назад
At 4:22 in video it shows measuring voltage on pipe before removing meter. But if the fault current was small i would imagine you would read zero volts. Then it would shoot up to 230v once you break the joint. Im just guessing here. Please clarify if this may happen. That would mean you must always put clamp on pipe before removing a meter regardless of what voltmeter says.
@Pure_electrical_training
@Pure_electrical_training 11 месяцев назад
At 4:22 the meter is removed, so I am not quite sure what you mean. If you measure with the meter connected, in a fault condition, you would measure a voltage. If the meter was removed, in a fault condition, you could read a fault on either side of the meter, but because the current has nowhere to go, it will just sit there until something or someone, completes the circuit. And that is the issue
@domrisk3572
@domrisk3572 Год назад
Promo*SM
@johnburns4017
@johnburns4017 4 месяца назад
_through_ *not* _frew._
@Pure_electrical_training
@Pure_electrical_training 4 месяца назад
Where does it say that John?
Далее
🤔
00:28
Просмотров 1,1 млн
Where Does Grounded Electricity Actually Go?
19:36
Grounding and bonding: Definitions and details
12:42
Просмотров 85 тыс.
Supplementary Protective Bonding and Touch Voltage
22:23
Off Grid Earthing & Bonding Made Simple | ØY17
21:44