Electrical Designing of High Rise Building G+10 | Electrical Design Course 

Electrical Infinity
Подписаться 45 тыс.
Просмотров 70 тыс.
50% 1

Hey guys! Welcome back to the new video of electrical infinity.
In this video, I attempt to explain the electrical design of high rise building G plus 10
It consists of 5 steps
1. Calculation of total connected load
2. Transformer sizing
3. Circuit breaker selection for transformer
4. Circuit breaker selection for main meter panel and flat load
5. Drawing of Single Line Diagram
Thanks For Watching
Electrical Infinity
Like and Subscribe!

Опубликовано:

 

11 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 147   
@prasenjit_hazra
@prasenjit_hazra 2 года назад
A Big Thanks for your magnificent job of teaching us from scrach. It often helpful to make some quality negotiation with consultant & infra individual as a "Sales Specialist".
@ElectricalInfinity
@ElectricalInfinity Год назад
Thank you too!
@SrujanRaghavendra-y9h
@SrujanRaghavendra-y9h Год назад
A very rare video on electrical design. Thank you so much for the clarity in explaining.
@ElectricalInfinity
@ElectricalInfinity 11 месяцев назад
You are welcome. Make sure you subscribe and share it with your friend's and colleagues. Thanks ❤️
@abdulkhadeer2351
@abdulkhadeer2351 Месяц назад
Thanks a lot for making a video of full knowledge, easy explaination, simple method.. it helps us a lot to perform best in company and to face the interviews. Tons of thanks to you❤
@abdiit5129
@abdiit5129 3 года назад
Great, thank you! Can we consider socket outlet power consumtion as a common connected load? And also please share us electrical design for residential house G+3 with all connected load like kitchen, lighting, washing machine, Iron, sockets, water pumps, oven , etc. Thanks bro.
@salunkhesandeep
@salunkhesandeep Год назад
Very well explained... Thanks so much for sharing knowledge....
@ElectricalInfinity
@ElectricalInfinity Год назад
Always welcome 🙂
@salahuddinbangash4785
@salahuddinbangash4785 2 года назад
Damn Nice bro, I thought it will be difficult but this is just basic electrical engineering 🔥🔥
@ElectricalInfinity
@ElectricalInfinity 2 года назад
Yeah much easier than engineering theories. But on Job it is a challenge to deal with complexity of projects. This was just a basic sample to make it easier for audience to understand.
@mdshadaabalam2612
@mdshadaabalam2612 3 года назад
Awesome explained.....sir kindly make video on cable sizing, voltage drop, ssc, bus bar sizing, earthing and lighting arrester calculation for the same project.
@mdshadaabalam2612
@mdshadaabalam2612 3 года назад
Request you to make video as soon as possible.
@gkd5421
@gkd5421 2 года назад
Sir, all your vedios are very informative..I seen all your channel... waiting for next latest vedios... thank you very much...
@ElectricalInfinity
@ElectricalInfinity Год назад
Keep watching
@saleembasha7924
@saleembasha7924 7 месяцев назад
Thank you for the detailed video bro.,👌👌👌👍👍👍
@ElectricalInfinity
@ElectricalInfinity 7 месяцев назад
Thanks Saleem 😊
@yatinthakuryt3362
@yatinthakuryt3362 5 месяцев назад
Thank you very much for giving such great information.
@ElectricalInfinity
@ElectricalInfinity 5 месяцев назад
You're welcome
@sefatullah441
@sefatullah441 3 года назад
manny many thanks sir g....outstanding video.......please continue thils topic electrical designing. upload more videos related to electrical building design..l...cable selection farmula etc.etc please
@sultanurrahman799
@sultanurrahman799 Год назад
It's helpful for technical support
@StephenAgutu-gt2xu
@StephenAgutu-gt2xu Месяц назад
Good work
@therealitypresenters8616
@therealitypresenters8616 4 месяца назад
Great, haven't found any video on any platform like this. Glad if add cable sizing calculation grounding and lightning protection system.
@ElectricalInfinity
@ElectricalInfinity 4 месяца назад
Glad it was helpful!
@saalimbaig4896
@saalimbaig4896 Год назад
Very useful information
@rajeevneela2861
@rajeevneela2861 10 месяцев назад
Thank you... good knowledge given
@smnmj3320
@smnmj3320 4 месяца назад
Thanks brother..it's a very helpful video.❤
@ElectricalInfinity
@ElectricalInfinity 4 месяца назад
Most welcome
@mobilesandcomputers5931
@mobilesandcomputers5931 2 года назад
I am working as a deputy messenger in a good housing society in Pakistan. I have seen your video on youtube. It is important to learn building. Tell me some main points
@incredibleindia3572
@incredibleindia3572 Год назад
Wonderful Explanation ❤
@9852626796
@9852626796 Год назад
Just now I seen your video it's outstanding. Can I get this elaborated topic in pdf format please.
@ElectricalInfinity
@ElectricalInfinity Год назад
Thanks 😊
@rahulgaikwad8430
@rahulgaikwad8430 Год назад
very good Explanation
@ElectricalInfinity
@ElectricalInfinity Год назад
Thanks for liking. Keep watching!
@shahbaazalam1003
@shahbaazalam1003 3 года назад
Can you please make a video on calculation of lightning arrestor and calculation of earthing rod, pits and wire?
@koala4599
@koala4599 2 года назад
first of all thank you for the great video, But please can you explain how you decide to use 7.5 kw for 3BHK ?
@yograjsingh3604
@yograjsingh3604 6 месяцев назад
wow very helpfull
@sagarvv4699
@sagarvv4699 3 года назад
Thank you so much for this. Could you please if you have time just explain the above 40-floors building details as per Indian standard.
@etelanarendra9873
@etelanarendra9873 11 месяцев назад
Excellent
@PraveenKumar-rh9bv
@PraveenKumar-rh9bv 6 месяцев назад
Awesome very useful
@ElectricalInfinity
@ElectricalInfinity 4 месяца назад
Thanks a lot
@imrankhan-uf7ww
@imrankhan-uf7ww 3 года назад
great work sir ❤️❤️❤️❤️
@engmohamedmuraase5119
@engmohamedmuraase5119 2 года назад
thanks sir for your kind to explain us more I would like to ask you PART-4 for the C.B sizing for main meter panel and flats.at PANEL-1 How you got common load result in 60kw? thanks sir.
@_InzimamImtiazuddin
@_InzimamImtiazuddin 5 месяцев назад
Thank you very much for this informative video. I had one question. 2BHK flats are provided with single phase supply. So when determining C.B size, for converting Watts to Amps, we should be multiplying with 8 and not 1.9 right? (Based on your G+5 electrical design video)
@sefatullah441
@sefatullah441 3 года назад
waiting for your next video.. please upload soon
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Soon
@spritor6463
@spritor6463 3 года назад
Good to see you upload regularly again :)
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Thanks 😎📽
@dineshmehta3688
@dineshmehta3688 Год назад
V good
@Bandarofficial
@Bandarofficial Год назад
Thanks you so much.
@emr207
@emr207 9 месяцев назад
🎉super
@ElectricalInfinity
@ElectricalInfinity 9 месяцев назад
Thanks 😊
@davendertaneja3489
@davendertaneja3489 3 года назад
Nice 👍
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Thanks 😊
@mithunmathew7965
@mithunmathew7965 2 года назад
Sir, We need to consider hvac load for public area and corridor's, Firepump
@roofi881
@roofi881 2 года назад
HI Dear, I wanted to know that why did you assume DF as 70% while for the commercial buildings you mentioned earlier standar DF is 80-90% in India. please explain this point, Thanks
@sangularnamibe8572
@sangularnamibe8572 2 года назад
was it 80-90% or 60-90%? I may be wrong.
@md.gufranansari9672
@md.gufranansari9672 3 года назад
Please make a video overall design parts such as cable calculation, voltage drop, short circuit, power factor.
@rashidchibvuri2036
@rashidchibvuri2036 8 месяцев назад
Thank you so much sir
@ElectricalInfinity
@ElectricalInfinity 8 месяцев назад
Welcome 🙂
@sandeshdhungana2749
@sandeshdhungana2749 2 года назад
Great video, thank you!! Would you make video on cable sizing considering voltage drop for high rise building.
@ElectricalInfinity
@ElectricalInfinity 2 года назад
Thanks. Will make it soon.
@jahanzaibilyas2649
@jahanzaibilyas2649 2 года назад
I think common load should be seperated and it should have Seperate SMDB
@ZubairAhmed-uc7tb
@ZubairAhmed-uc7tb Год назад
Thanks for the Video, Can your please explain how the Multipier Value (KW - A =x1.9 ) Comes. Where as I =P/(VxPF) for Single phase and I = P/(1.732xVXPF). Kindly Correct me if I am Doing any mistake understanding Data manipulation. Warm Regards
@shahbaazalam1003
@shahbaazalam1003 3 года назад
Can you make a video on the cable size selection from transformer to transformer's CB and from tx's CB to load' CB?
@AkashSingh-jz4zo
@AkashSingh-jz4zo 2 года назад
In the video, df for residential is mentioned as 0.6, but you considered 0.75, why the difference? And what are the actual standards?
@franchettecariaga
@franchettecariaga Год назад
Hello! I just saw your channel and I am so thrilled. J would just like to ask.. Is this as per australian standard?
@ElectricalInfinity
@ElectricalInfinity Год назад
Hi Franchette 👋, Thanks for watching. Yes, the design is as per Australian standards.
@Saichanti77
@Saichanti77 Год назад
Thanks ❤
@kobe8502
@kobe8502 4 месяца назад
At 11:00 how did you get those MCCB values? Why is it almost doubled when you already multiplied them by 2?
@anandsatsangi1071
@anandsatsangi1071 4 месяца назад
Safety factor
@Premkumark90
@Premkumark90 2 года назад
Hello, Can I convert kw to amps by . First kw to kva Then kva to amps. If do like this different values coming ,what should I do?
@Concepttalks98
@Concepttalks98 2 года назад
Brother you didn't count future expansion of 20-30% why? Also you considered only demand factor but not diversity factor .. And i designed further and calculated and i got secondary current more than 1200A ...so should I take 3 runs of 1core 300sq mm cable or 3 run of 3 core 300sqmm cable.?
@Belive_trust_wait
@Belive_trust_wait 2 месяца назад
Sir give a link for , workout screen calculation...give a new video also sir
@altamashsayed5264
@altamashsayed5264 Год назад
I have a doubt related cb sizizing For 1500kva transformer Secondary side. Once we convert kva to amp 1500kva*1.4 =2100A Should be consider 1.5 safety factor or directly select breaker from 2100A
@kv848
@kv848 3 года назад
Great brother..Suppose you have 2 transfer pumps,1 is standby and other is on duty, means they will work interchangeable and both will not ON at Sam time and they are in same panel MCC,..So how will you calculate main cable to this panel, will you consider kW of both motor or only 1 ?
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Total of both.
@kv848
@kv848 3 года назад
@@ElectricalInfinity but at any instant, both will not work together, then why we consider both load ? Is it general rule to consider both ?
@ElectricalInfinity
@ElectricalInfinity 3 года назад
That's why we take 0.7 demand factor after calculating total load.
@sabinaktar5135
@sabinaktar5135 Год назад
fab❤
@ElectricalInfinity
@ElectricalInfinity Год назад
Thanks
@mujeebrehman7097
@mujeebrehman7097 Год назад
How you find the value of 1.4 when you convert kva to amp ?
@swapnilshiyaniya5306
@swapnilshiyaniya5306 Год назад
Time 11:04 When you are calculating MCB for 2BHK load, you multiplied 5kw by 1.9 ... but wo to 3 phase ke liye aayega na ... for 1 Phase 5.43 Amp aayega na as 5 kw load is Single Phase load. Please correct me if i am wrong.
@eaknadhwilson5931
@eaknadhwilson5931 Год назад
Bro it's better to share the image of those calculations thanks 👍🏻 very useful
@ElectricalInfinity
@ElectricalInfinity Год назад
Noted
@demonkiller2358
@demonkiller2358 3 года назад
Can u make video on Important is and nec standards
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Will try to make one
@seng7333
@seng7333 Год назад
Nice explanation But The breaker size of 40A for 5kw load seems to be high Also 50A breaker is not standard size
@copycatonlyoriginal6585
@copycatonlyoriginal6585 Год назад
Could you please provide links to reference guidelines?
@arunkumarthakur9679
@arunkumarthakur9679 2 года назад
B+P+33 including club, stp, water supply, fire system. Provide electrical load calculation.
@altamashsayed5264
@altamashsayed5264 2 года назад
I need urgent help. Actually I got bit confused. I have to select cable, which load I should consider while selecting cable size from transformer to MDB Should it be tcl amp or peak load amp or transformer amp or circuit breaker amp. Pls do reply as early as possible
@ElectricalInfinity
@ElectricalInfinity 2 года назад
Usually a cable between transformer and supply connection facility is provided by supply authority and is sized depending on transformer secondary side ampere setting. Supply connection facility is used by supply authority to set the current to certain required amperes depending on supply application done by electrical consultant by calculating max demand. The cable from supply connection facility is sized depending on circuit breaker setting in supply connection facility. I hope this answers your question.
@altamashsayed5264
@altamashsayed5264 2 года назад
@@ElectricalInfinity appreciate your reply..
@anwarullakhayoom7863
@anwarullakhayoom7863 2 года назад
Always cable +breaker is sized as per continous current of the Transformer + consider the derating factors for grouping depth of laying and Thermal withstand capacity. and also the voltage drop . all calculated precisely.
@kalingahistory
@kalingahistory Год назад
But the loads you clubbed together are single-phase loads. Where as the main power supply will in three phases.
@everythingforyouonly5694
@everythingforyouonly5694 3 года назад
Why you take 2 time demand factor 1) for TCL and 2) for metering panel c.b selection
@everythingforyouonly5694
@everythingforyouonly5694 3 года назад
Please give the answer ?
@tharserohit
@tharserohit 2 года назад
Bhai single phase meter kitna load leta he
@itz_tipzy5949
@itz_tipzy5949 2 года назад
Where is the standard to be exact for 2bhk 5kw energy meter and 3bhk 7.5kw? I need to furnish it for a project of mine...
@ElectricalInfinity
@ElectricalInfinity 2 года назад
IS 13010
@itz_tipzy5949
@itz_tipzy5949 2 года назад
@@ElectricalInfinity thank you so much
@itz_tipzy5949
@itz_tipzy5949 2 года назад
@@ElectricalInfinity can't find it in there... Is it mentioned explicitly that for a 2bhk this much capacity energy meter and so on... I have calculated loads of all flats individually but even after taking into diversity factor the load is quite large...
@itz_tipzy5949
@itz_tipzy5949 2 года назад
@@ElectricalInfinity also if I could discuss it with you somwhere else..
@ElectricalInfinity
@ElectricalInfinity 2 года назад
It's a general thumb rule contractor follows for considering total load. Usually it's 0-10 amps, 10-20amps and 20-30 amps energy meter rating.
@AbidKhan-tj6en
@AbidKhan-tj6en Год назад
Ipad kaun sa hai bhai btana lena hai mujhe
@electricalconcept32
@electricalconcept32 3 года назад
Sir can you tell me if load is 868KW, power factor is.0.8 and voltage is 415v and the cable length is 138meter. Which size cable we should chose to have maximum voltage drop of 3 percent
@anwarullakhayoom7863
@anwarullakhayoom7863 2 года назад
Calculate VD on actual current , Not on Derated Current. Derated Current is only for cable+Equipment selection.
@sefatullah441
@sefatullah441 3 года назад
please make your next video at low speed
@digantpatankar3758
@digantpatankar3758 2 года назад
Sir please mention cable size.....in SLD...
@ElectricalInfinity
@ElectricalInfinity 2 года назад
Will do separate video for that
@tamaghnadutta1644
@tamaghnadutta1644 2 года назад
From where I can get the Standerd chart of Transformer , Cb e.t.c
@ElectricalInfinity
@ElectricalInfinity 2 года назад
You can get Transformer standard sizes from supply authority and cb sizes from manufacturer manuals or datasheets.
@anwarullakhayoom7863
@anwarullakhayoom7863 2 года назад
Buy TNEB Hand book.
@Aliajikar89
@Aliajikar89 2 года назад
Raw power is done ...Sir plz added ups power....
@habibullah7853
@habibullah7853 8 месяцев назад
This is very informative. I am here in UAE as a fresh electrical engineer and looking for job. Can anybody help me getting a job. Thank You
@sachinlandge6401
@sachinlandge6401 Год назад
How to calculate electrical meter room and duct size
@kobe8502
@kobe8502 4 месяца назад
It would be great to explain this slowly. Kind of confusing and some details were not explained properly. Why did you use 400A in 9:52?
@sherifgamal730
@sherifgamal730 2 года назад
Can i have this Sheet you write in the video please?!
@KhanContent
@KhanContent Месяц назад
Time 06:17 where this 1.4, 1.9 and 1.5 came from ?
@mangeshdalvi842
@mangeshdalvi842 3 года назад
Whay about shop, if considerd?
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Well we need add total load of the shop and consider demand factor as 0.8 to 0.9 for commercial places.
@muhammadwaqas4699
@muhammadwaqas4699 Год назад
Circuit breaker calculations?
@AK_Entertainment26
@AK_Entertainment26 Год назад
please upload video we are waiting for new video
@VijayKumar-qx1kr
@VijayKumar-qx1kr 2 года назад
IN FOUR POINT HOW WILL YOU DESIGN THE PANEL?
@mudassariqbal8532
@mudassariqbal8532 Год назад
You should explain it according to any international standard,
@sumanbepari609
@sumanbepari609 2 года назад
How a flat will use 3 phase???
@ElectricalInfinity
@ElectricalInfinity 2 года назад
All loads are distributed equally among each phase of 3 phase supply. Usually the loads are single phase for example lighting circuits and power loads. If it's 3 phase load then a 3 Phase supply is provided.
@sumanbepari609
@sumanbepari609 2 года назад
@@ElectricalInfinity sir, then there are SPN inside the room which are not showing here???
@anwarullakhayoom7863
@anwarullakhayoom7863 2 года назад
upto 3KW - 1PH /240V IS enough , >3kw opt for 3ph 415v.
@shaneefh926
@shaneefh926 3 года назад
For 19 amp y we use 40 amp breaker+
@khan__123
@khan__123 2 года назад
Bhai ye pen kaha se magbaye
@ElectricalInfinity
@ElectricalInfinity 2 года назад
Logitech
@kashmirengineeringvision
@kashmirengineeringvision Месяц назад
really helpful amir need a small help is it possible to get in touch with you that will be your most kindness
@prithivi5440
@prithivi5440 Год назад
Hloo bro can you share your linked in profile?
@outofthebox6027
@outofthebox6027 4 месяца назад
Sir can you share the notes??
@mohammedezaj1018
@mohammedezaj1018 3 года назад
Where is cable sizing, voltage drop, sc calculation?
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Will make another video for that. The video would have become lengthier if added everything you asked for.
@mohammedezaj1018
@mohammedezaj1018 3 года назад
@@ElectricalInfinity Thank you
@mustafaidris6476
@mustafaidris6476 5 месяцев назад
Thank u , but its very fast way so As you r trading from papers
@mobilesandcomputers5931
@mobilesandcomputers5931 2 года назад
ONLY I NEED YOUR ONLY FEW TIME IF POSSIBLE I WIST YOU GIVE ME POSITIVE RESPONSE
@everything7790
@everything7790 4 месяца назад
1 KVA = 1.9 anybody explain please in my calculation its is 1.39 something
@md.gufranansari9672
@md.gufranansari9672 3 года назад
This video already you had made
@ElectricalInfinity
@ElectricalInfinity 3 года назад
Steps 4 and 5 are different. This one is for high rise building not g plus 5. Watch it full you will know the difference. 😊
@notfalcongaming7839
@notfalcongaming7839 3 года назад
Hlo
@farazuddin7160
@farazuddin7160 10 месяцев назад
they said three lift but write only two lifts
@peopleofkpk5558
@peopleofkpk5558 Год назад
Very interesting but your vedios is too much fast 🙈
@ElectricalInfinity
@ElectricalInfinity Год назад
Thanks and sorry for that. You can use reduce the speed to 0.8x while watching
Далее
Oops 😅
00:10
Просмотров 6 млн
Обыкновенное чудо
00:48
Просмотров 857 тыс.
Million jamoasi - Sportsmenka bilan uchrashuv
15:05
Просмотров 645 тыс.
4 Year Sibling Difference! 😭 #shorts
00:11
Просмотров 9 млн
The Electrical Distribution System
12:35
Просмотров 378 тыс.
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
5 Formulas Electricians Should Have Memorized!
17:00
Просмотров 953 тыс.
Flawless PCB design: RF rules of thumb - Part 1
15:45
Which Electrical Engineering Subfield is For You?
40:27
Busbar sizing
9:27
Просмотров 133 тыс.
Oops 😅
00:10
Просмотров 6 млн