@LeighWinspear
@LeighWinspear 6 месяцев назад
Eyup, learning plenty from your videos.....Just wondering if you have ever replaced your CK/Jokari tool blades? If so how and how much as mine have just given up after a coupla years........
@JoeJoe-sw6zy
@JoeJoe-sw6zy 5 месяцев назад
Thank you host for sharing your work experience, I hope there will be a translation of traditional Chinese, thank 🙂🙏🙏
@TheTW11
@TheTW11 6 месяцев назад
I'm not a sparks, but it seems to me that industrial is much better work than domestic.
@pistolpete5189
@pistolpete5189 6 месяцев назад
It’s nice when your neat work is left on display and not covered by 12 rolls of insolation
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Yeah I agree
@persona250
@persona250 6 месяцев назад
If someone came in and disconnected a cable it would be their responsibility. You could have fitted none of the banjos and earthed the suitably sized trunking with a suitably sized cable .
@TheChipmunk2008
@TheChipmunk2008 6 месяцев назад
True but it's always nice to try to idiot proof your work. Idiots are everywhere :)
@harryhall2709
@harryhall2709 6 месяцев назад
Tidy Job Chris, better to be looking at it than for it 😆👍🏻
@johneastmond9092
@johneastmond9092 6 месяцев назад
Better to be looking at it then looking for it!
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Yes that’s the one ☝️ 👍
@Mc674bo
@Mc674bo 6 месяцев назад
Hi both. Still enjoyed this type of work as much as any other , that of installing metal trunking tray and conduit . Must have done miles of it , but it’s nice to see someone else doing it , especially when they make such a great job like yourselves . Kind regards
@TheChipmunk2008
@TheChipmunk2008 6 месяцев назад
Banjos are still 'new' to me lol, qualified in the early 90s, never used banjos. But they ARE necessary on modern DBs as they're so heavily painted it's impossible to get a decent earth. Unless you use those spendy pirahna earth nuts or similar. I always toss the thin lock nuts that come with BW/CW glands, and use lock RINGS instead, much easier to work with as they're thicker
@tremblingnoobs5149
@tremblingnoobs5149 6 месяцев назад
Let's go Chris, just recently became a journeyman
@gadgetman36
@gadgetman36 6 месяцев назад
I love your videos. I'm curious why the video format has changed from 16:9 to 4:3. If you can please change it back to 16:9. Thanks.
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Sorry didn’t edit it for RU-vid wide
@Pieman2008i
@Pieman2008i 6 месяцев назад
That's the cleanest hospital plant room I've ever seen! 😂 You can get spring clips for steels made by walvern or something from shittys. Nice job, keep up the good work!
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Yeah beam clips are great but for 6 fixings drill and bolt
@mxslick50
@mxslick50 6 месяцев назад
Beautiful work as usual! I would love to come work with you and James if I ever get back to the UK.
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Let’s do it
@alvina69
@alvina69 6 месяцев назад
That’s a decent day’s work 👍
@persona250
@persona250 6 месяцев назад
Is that tray screwed directly to the wall ? You should try the met pro rolla tray . Fixes direct
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Washers on the 700 long bits
@rogerneale4319
@rogerneale4319 6 месяцев назад
Do you put a flexible grommet around the cutout in the bottom of that panel?
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
No I’ve fitted paxolin
@shibby7153
@shibby7153 6 месяцев назад
It is my understanding that SY cable is only suitable as a control cable and not power more than possible that I am wrong but maybe worth looking into. Another great vid as always your attitude towards your work is an inspiration. Keep up the great work!
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Who’s been using SY cable ?
@shibby7153
@shibby7153 6 месяцев назад
haha just watched it back at 4.35 i thought you said 10mm SY not SWA my apologies@@Cjrelectrical
@ryang6572
@ryang6572 6 месяцев назад
Out of interest (I know nothing about building / structural) is that many holes bored on the bottom of the block (nearly the whole thing) not going to compromise it?
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
See below it floor and metal lintel and non structural above.
@Jay369
@Jay369 6 месяцев назад
Wouldn't be much of a wall if one "damaged" block would affect it. 😂
@tangoengineering
@tangoengineering 6 месяцев назад
Don't forget to bond the tray
@Cjrelectrical
@Cjrelectrical 6 месяцев назад
Did you listen ? I know the AHU are loud
Далее
Electrician VS Angry Customer
11:08
Просмотров 78 тыс.
Ответы Мэил Ру
01:00
Просмотров 1 млн
100 Identical Twins Fight For $250,000
35:40
Просмотров 51 млн
Watermelon magic box! #shorts by Leisi Crazy
00:20
Просмотров 27 млн
Steak Bake stop off = van tools knock-off!
10:39
Просмотров 20 тыс.
I Dropped 2 Phases For This
16:11
Просмотров 19 тыс.
This Is Why Builders SHOULDN'T Do Electrics! 🫣
19:59
En dag som Elektriker
12:38
Просмотров 40 тыс.
Smart Meter Disaster!!
16:33
Просмотров 433 тыс.
we work ish.. at the 6 Bedroom house
11:56
Просмотров 9 тыс.
HOT HOT HOT - INSTALLING AIRCON. No idea!!!!
15:34
Просмотров 22 тыс.