Electronic flat roof leak detection Testing a leaking roof Roof surveys 

Steve Roofer
Подписаться 30 тыс.
Просмотров 24 тыс.
50% 1

As a roofing surveyor, I'm often asked to do surveys on flat roofs that are leaking. Most of the time we can locate the problem without using any specialist equipment and the first thing to do on any roof is to have a visual roof survey undertaken as this is the most economic starting point.
If however, we cannot locate the roof leak on this roof inspection we will need to move to the next stage of leak detection. The electronic flat roof leak detection we are doing on this roof sends a pulse down into the roof to try to find moister deep down in the makeup of the roof, this kind of electronic flat roof leak detection is good for warm roofs as we can penetrate down to the lower deck of the roof where the water would naturally run. After griding out the roof we carry out two different sweeps of the roof trying to detection the wet spots in the roof and thus leading us to the leak in the flat roof. We mark out the sections that are the watest and form a moister map of the roof. This visual moister map of the flat roof shoud now indicate approximately where the water is getting into the roof and where it may be tracking. We can now start to investigate the roof membrane above to see if we can find where the leak is. Electronic flat roof leak detection is just one too lwe youse to try to find leaks in flat roofs Its a useful tool however it cannot be used on some rubber roofs and has a problem with metal that will give false readings. The electronic flat roof leak detection equipment we are using on this roof is a single that is suitable for finding leaks in relatively small roofs probably up to 100 m² . We also have electronic flat roof leak detection equipment that we can use on much larger roofs, these units have mobile heads and are on wheels so that the user can walk around the roof taking measurements.
#londonflatroofing
#roofsurveyor

Опубликовано:

 

3 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 55   
@d8461
@d8461 2 года назад
I'm no roofer but to me this shows somebody who takes pride in their work and has a keen interest in all aspects of their job. Cant beat someone who's passionate about what they do. Brilliant.
@SteveRoofer
@SteveRoofer 2 года назад
Thanks
@benrichards1
@benrichards1 2 года назад
Glad you're making videos again. Very informative.
@SteveRoofer
@SteveRoofer 2 года назад
More to come!
@jaki1979
@jaki1979 2 года назад
Yes please
@haroon420
@haroon420 2 года назад
All that insulation being ripped apart is making my eyes water!! 💸💸💸
@SteveRoofer
@SteveRoofer 2 года назад
Yes it was such a shame nex video will explain why
@dannymurphy1779
@dannymurphy1779 2 года назад
Very interesting Steve. A chain is only as strong as its weakest link! Looking forward to the reveal.
@SteveRoofer
@SteveRoofer 2 года назад
Correct except we are not training our links
@philsims6607
@philsims6607 2 года назад
As has already been said great to have you back Steve! You didn't say in the video what was wrong to cause the leak?
@SteveRoofer
@SteveRoofer 2 года назад
I will do that in one of my next videos
@brandongranados5569
@brandongranados5569 11 месяцев назад
The membrane had small cuts that barely let water seap in. Maybe before setting the membrane the roll was sitting on top of gravel, when unrolled it got cut. Maybe somebody had a sharp object underneath their shoe when setting it up, somebody threw a rock on the roof, when setting it up they might have dropped their sviccors or box cutter knife on accident leaving a really small hole barely noticeable to the eye. Etc
@SteveRoofer
@SteveRoofer 11 месяцев назад
No, we know what the problem was. The problem was that he didn't use enough liquid to saturate the reinforcing membrane. You could actually see that some of it was still naked.
@dominiktur6235
@dominiktur6235 2 года назад
Good job.But there are better and faster methods, such as the electric imulsus method on a wet and dry roof. Good for any weather. Although I must admit that RWS Tramex is one of my favorite devices. Best regards from Belgium and good luck.
@SteveRoofer
@SteveRoofer 2 года назад
Thanks for the tips!
@aryana2324
@aryana2324 7 месяцев назад
Hello great video! I have a question, Ive a concrete ceiling which has been waterproofed but still I see water during inside the hoouse thorugh a crack, the issue here is that none of the experts who came to inspect where able to get to the source of the leak, we see the leak but not knowing from its coming, any trick to check that please?
@advancedue476
@advancedue476 3 месяца назад
They probably should have painted that membrane over the wood as well
@bobjit252
@bobjit252 2 года назад
Doesn’t this show that these types of roofs aren’t actually that good as the workmanship doesn’t look bad , and looks as though it’s been done the right way ?
@SteveRoofer
@SteveRoofer 2 года назад
Its the workmanship they didn't apply the liquid to the correct depth
@AWB70UK
@AWB70UK 2 года назад
Another great video, I've been watching these now for months and the tips I've picked up are priceless regarding why warm roofs fail. Just waiting for a break in the weather before getting mine fitted which hopefully is very soon. I wish you worked up our way as I often find myself having to point things out to the roofer. Steve, one things I'm still confused about is I appreciate that you recommend using a self adhesive VCL but in one of your previous videos you advised someone to use a novia polythene kit which I bought at the time, one thing I'm not sure about is what do you think is the better detail for the vcl at the top of the kingspan layer? Folding the excess vcl over the upstand and perimeter before fitting the secondary layer of osb or folding it back in over the top of the kingspan and taping it down?
@SteveRoofer
@SteveRoofer 2 года назад
If its a warm roof you should be using Alutrix 600 novia polythene kit can be used for a warm roof but is more difficult to use I think he already had it and that's why it was used
@AWB70UK
@AWB70UK 2 года назад
@@SteveRoofer yes, I wish I did get the alutrix but I found out about the product after I had already bought the Novia. The guy who did the drawing just stated "vcl" then I found a celotex detail showing 1000 gauge vcl so went with that. I had to buy 100m2 worth when I only need 18 so I couldn't really buy the alutrix as well. Any tips or mistakes that should be avoided when using the Novia?
@warrenbarton6608
@warrenbarton6608 2 года назад
Hi Steve, why do you say "good choice of insulation,tissue-faced not foiled-faced ? Thanks Warren
@haroon420
@haroon420 2 года назад
Tissue faced is the recommended one I believe but I think everyone uses foil because of price. And I don’t think performance is *much* more different.
@SteveRoofer
@SteveRoofer 2 года назад
@aroon420 is correct basicly tiles faced insulation is more oven cell IE it breaths a little better however its more expensive
@peteramberley9952
@peteramberley9952 2 года назад
Looked like duoply epdm or was that the grid lines put on?. What we really want to know Steve is the fallout and who's paying for it to be put right. There's a lot of money someone's losing.
@SteveRoofer
@SteveRoofer 2 года назад
All that info will be coming in my next video
@saintslad5399
@saintslad5399 2 года назад
Very informative video thanks. One question though, I assume this piece of equipment works similar to a conductive damp meter you would stick in walls to find rising damp etc. Does this piece of equipment have the same shortfalls of a damp meter for example giving false high readings when a conductive material such as foil backed plasterboard is detected within the roof?
@SteveRoofer
@SteveRoofer 2 года назад
Yes, also won't work through some single plys such as rubber but I have tested it on rubber and it worked!
@timmymues9256
@timmymues9256 2 года назад
If only the top layer Epdm is repaired and leak proof, is it possible that the moisture drys by time itself?
@SteveRoofer
@SteveRoofer 2 года назад
yes but slowly
@kenmammel7748
@kenmammel7748 10 месяцев назад
I've got water between layers on my flat roof. It sounds like a tennis shoe sneaker after walking under water. From the sky inward, there is a standing seam metal roof, then TPO rubber roof, then 2 layers of ice and water-shield. How can I get the large amount of trapped water out of there?
@kevinrae3299
@kevinrae3299 2 года назад
Maybe laid the boards in the wet? Liquid applied should have a carrier membrane. Is the water detector a good investment?
@SteveRoofer
@SteveRoofer 2 года назад
Think it was dry but one of my next videos will explain why we striped this. is it a good investment if it lasts another 5 years yes but at around 2K No
@THE-AIDEN-PROJECT
@THE-AIDEN-PROJECT 2 года назад
Hi Steve, would you cover SE3 at all? Could you give an indication on how much a non invasive flat roof survey would cost? Roof is less than 10m2
@SteveRoofer
@SteveRoofer 2 года назад
Email me with more info and photos and ill get back to you with a cost info@londonflatroofing.co.uk
@dublinboy
@dublinboy 2 года назад
That could of been put down with wet weather. Sorry to say but flat roofs in the uk are lagging miles behind europe.
@SteveRoofer
@SteveRoofer 2 года назад
It is wet weather and bad workmanship and choice of materials
@asif530
@asif530 2 года назад
Would it have helped if there was ply ontop of the insulation?
@SteveRoofer
@SteveRoofer 2 года назад
No they didn't apply the liquid roofing correctly
@Jackzuk
@Jackzuk 2 года назад
Has the poor owner had to pay twice to have this roof fitted due to the 1st persons poor work or was he lucky enough to have insurance company cover it
@SteveRoofer
@SteveRoofer 2 года назад
From my understanding, the roofer wasn't paid really unfortunate as he tried his best and used a lot of expensive materials but as you can see the work was substandard
@zigavojska1672
@zigavojska1672 2 года назад
culdnt you just put another layer of liquid insulation?
@SteveRoofer
@SteveRoofer 2 года назад
No as there was water trapped in the constitution now
@zigavojska1672
@zigavojska1672 2 года назад
it would dry out eventually
@SteveRoofer
@SteveRoofer 2 года назад
​ @Ziga Vojska Possibly and there may not be any mildew or fungus that grown. however, the scaffolding is there the opportunity is there the other roofer is at fault and needs to give the customer a proper roof with no Ifs and buts. What would you do if you were the customer?
@ianhastwell9194
@ianhastwell9194 2 года назад
Crazy .... just let's get this right...you laid a roof on top of the old roof ...that's fine but you say roof has only been down a few days and had rain before you arrived to test ...maybe the roofers got caught out by the rain when doing the installation and water got under the insulation before they could cover it up ...the liquid roof looked OK to me...why is the customer walking around the roof ....was water showing inside ...if not then that's just stupid ripping up the roof ...as if new roof wasn't leaking into the building surely what water was sitting on the old roof would of evaporated in time and would of been find 🤔
@SteveRoofer
@SteveRoofer 2 года назад
The problem was the water was in the roof and could not get out
@ML167305
@ML167305 7 месяцев назад
@@SteveRooferHey Steve what’s the name of this machine or the manufacturer? I’m across the pond and no one does this over here. It would be cool.
@PeakyBlinder
@PeakyBlinder 2 года назад
Always perform an electronics test on completion of any liquid roof, As morons will use the roof as a storage area. This will then puncture the membrane. And never apply liquid directly to insulation. Fix ply onto of the insulation to prevent punctures.
@beltdrivetypea6534
@beltdrivetypea6534 2 года назад
Why not just go over it again rather than rip it up
@SteveRoofer
@SteveRoofer 2 года назад
It had water under it and they hadn't insulated around the side
@beltdrivetypea6534
@beltdrivetypea6534 2 года назад
@@SteveRoofer cheers
@eddjordan2399
@eddjordan2399 2 года назад
what a waste of materials
@SteveRoofer
@SteveRoofer 2 года назад
Yes unfortunate
Далее
Flat Roof Leaks
6:09
Просмотров 206 тыс.
why roofs in Sydney leak only in heavy rain
8:20
Просмотров 84 тыс.
БАГ ЕЩЕ РАБОТАЕТ?
00:26
Просмотров 153 тыс.
Vapour barriers for roofs and walls explained
9:58
Просмотров 109 тыс.
Electronic Leak Detection | Build Meets World (EP. 06)
33:06
leak detection video
9:10
Просмотров 7 тыс.
Inspecting a 2 month old TPO roof that still leaks
16:40
Preparing for an Electronic Leak Detection Test
4:28
Просмотров 3,5 тыс.
Charlie Luxton is Leak Testing his Flat Roof
4:45
Просмотров 9 тыс.