Тёмный

ELEVATOR MALFUNCTION! 

Star City Elevators
Подписаться 2,2 тыс.
Просмотров 39 тыс.
50% 1

Shot 8/27/2017 & 8/30/2017.
Any elevator technicians who are watching: Can you identify what might've been going on here? I think it's some sort of controller issue.
Anyway, the Woods art building got a new elevator to replace the Wright & Mack (which should've never been ripped out!). This elevator is only about a week old and still needs to be broken in, so I will give it that.
Like me on Facebook: / starcityelevators
Follow me on Google+: plus.google.com/+starcityelev...
Website: starcityelevators.weebly.com/
Direct contact: starcityelevators@gmail.com
© 2017 Star City Elevators Productions

Игры

Опубликовано:

 

8 сен 2017

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 109   
@stevereeves9104
@stevereeves9104 5 лет назад
This is a hydraulic elevator. What it's doing is called "blowing through the floor" in the down direction. Unit valve in the machine room most likely was out of adjustment. It's hitting the buffer springs in the pit and releveling up to the floor. This opens the bottom emergency terminal switch which cancels the call that was registered. Doors then won't open unless DO is pushed on the COP or another call is registered. When it blows through intermediate floors in the down at full speed, it levels down to the next floor. Single floor runs it's not getting up to rated speed and re levels at the floor. Typical of Down Transition not being adjusted properly. That adjustment increases and decreases the Down Leveling transition from full speed. I've installed, replaced and adjusted Maxton and EECO unit valves many times in the last 14 years as an Elevator Constructor.
@beedslolkuntus2070
@beedslolkuntus2070 5 лет назад
Wow thanks for explaining mate
@jonathankoster547
@jonathankoster547 2 года назад
I've been looking for this for YEARS and I finally found it!
@TheOfficialDorianelevator
@TheOfficialDorianelevator 10 месяцев назад
man that hydraulic valve is completly busted... oh and also 4:47 killed me of laughter
@2035jim
@2035jim 2 года назад
It’s not a controller issue it needs a new hydraulic valve
@kanaibanerjee5519
@kanaibanerjee5519 5 лет назад
I have handled many an Elevator Malfunction related to Power Quality and Voltage Fluctuation Issue. These problems are increasingly becoming widespread with the installation of LED Lights and Drives. All those problems have a pattern and you can identify those from the WEB-PAGE below. However, looking into this problem, it is surely NOT DUE TO ANY POWER QUALITY PROBLEM. It is purely a Bad Installation and the OEM need to fix it - it's as simple as that. enconengineers.in/elevator-and-escalator-problem-vfd-drive-card-failure
@arizonaelevatorsandmore2778
This elevator is definitely not a Minnesota Elevator, this is a generic junk elevator.
@EvergreenElevators
@EvergreenElevators 3 месяца назад
Did you not see the branding on the door jamb at the beginning of the video when he shows the door equipment? Because I'd argue it says otherwise...
@blockavgaming7440
@blockavgaming7440 Год назад
I also have a deep fear of elevators, so thats why i always use the stairs.
@JuanP1930
@JuanP1930 Год назад
Everything is gud if you use an hydraulic elevator because in that one you can't free fall in the elevator
@VeeTHis
@VeeTHis Год назад
@@JuanP1930 Traction elevators can't free fall either
@JuanP1930
@JuanP1930 Год назад
@@VeeTHis why are you in a comment from 3 months ago?
@Patriot2609
@Patriot2609 Год назад
The elevator is statistically much safer than taking the stairs...
@jetway756
@jetway756 4 месяца назад
​@@JuanP1930Fun fact, sounds stupid, but hydraulic elevators CAN free fall, and in a more uncontrollable way than tractions, but as long as they're maintained well that won't happen
@AlanTech1
@AlanTech1 Год назад
you ended the video when you where inside the elevator most people end it when there outside just saying Lol
@jahairareyes5638
@jahairareyes5638 2 года назад
your not alone 😂 that happens to my elevator sometimes
@BNSF4475
@BNSF4475 2 года назад
Nice job MEI 🙄
@EC_3276
@EC_3276 5 месяцев назад
MEI with fully innovated bruiser
@boiii3productions945
@boiii3productions945 Год назад
If it’s new it should’ve been mrl not hydro
@EchoDot3
@EchoDot3 9 месяцев назад
That isn't normal...
@bernardtheaubreycoxandcoolgame
@bernardtheaubreycoxandcoolgame 2 месяца назад
That's creepy
@Creamcrus
@Creamcrus Год назад
why the elevator 1st the 1F to BF HUH
@apetersenALT
@apetersenALT 6 лет назад
This is why generic stuff SHOULD NOT EXIST!
@lucasnassar2778
@lucasnassar2778 6 лет назад
Adam Petersen Maybe this one was sed up to manual controlling
@CenTexElevators489
@CenTexElevators489 6 лет назад
See what I mean about these newer generic elevators? They break down so much, because they always are the lowest bidder, and the old ESCO lasted 55 years with absolutely NO problems!
@lucasnassar2778
@lucasnassar2778 5 лет назад
CaptainElevator42189 And why Star City Elevators rides this thing,why didn't waited one month to go,it's not full calibrated yet,if I was him I had to wait after 1 month at least modernized then I could go
@mattmoreira210
@mattmoreira210 5 лет назад
Oh! I don't think it's supposed to do that... let's continue riding it until it breaks!
@aprilkolwey4779
@aprilkolwey4779 6 лет назад
As kind of a wild guess, maybe the ULM (upper leveling marker) sensor on the tapehead isn't working properly, so it doesn't realize it should be slowing down for the floor until it actually gets there. By that point, it's too far to stop in time, so it misses the floor, and then the controller decides to go downwards to one of the limit switches (bottom floor demand) to kind of "recalibrate" in response to seeing unexpected inputs from the broken tapehead.
@ThompYT
@ThompYT 6 лет назад
probably also doesn't help that it's most likely a 2 speed motor
@aandersen93
@aandersen93 6 лет назад
I also feel like placing the fire alarm and call station next to each other may not be a good idea on the 1st floor.
@JordanLoweElevaToursCanada
@JordanLoweElevaToursCanada 6 лет назад
aandersen93 I agree.
@casualgamer24
@casualgamer24 6 лет назад
YA SOMEONE can easilly pull it
@silasmcgee3647
@silasmcgee3647 6 лет назад
Evan The gamer 3:04that's probably the cutest sound the elevator made
@thecarwashelevatorfanatic7433
@thecarwashelevatorfanatic7433 5 лет назад
Silas McGee Weird.
@helpthehurtlondon
@helpthehurtlondon 5 лет назад
just an afterthought, that fire alarm pull station is wayyyyy too close to the elevator call buttons
@chrisblackstone5975
@chrisblackstone5975 6 лет назад
the second part of the video you mentioned some vibrations. The mic picked that up perfectly. I am wondering if for some reason the brake wasn't catching properly if that would cause the vibrations I heard at the end of the video.
@sheagenix5320
@sheagenix5320 4 года назад
You're super brave to play with elevators the way you do. I couldn't do it, so it wouldn't be the job for me. I barely like riding them but then again I don't like exercise so there you go lol
@aandersen93
@aandersen93 6 лет назад
The elevator in Temple Building will often under level when it hits the basement and relevel while the door is open. Sometimes on other floors as well if it's been heavily used that day.
@aghcatz
@aghcatz 6 лет назад
Can you please go to Lithuania for a lift test? There are some old elevators, you can check them out ;)
@HSETM
@HSETM 5 лет назад
When it's going up, the stuff under the lift might be pulling on the buffer spring. When it's going down, the buffer might be hitting something, making it safety break
@supertechnocat8253
@supertechnocat8253 5 лет назад
Any background history of Wright and Mack elevator?
@Jamestube8439
@Jamestube8439 6 лет назад
Is it a Schindler? Also I think the elevator was going down and while it was doing it, it crashed to the ground and then it thinks it messed up and moves up to level with the floor, that's I think, it may not be calibrated with the floors correctly
@Jamestube8439
@Jamestube8439 6 лет назад
Also notice, you can here the motor after the crash, it had to be leveling with the floor when it crashed.
@matttherailfan
@matttherailfan 6 лет назад
It’s a Minnesota
@SAMIEWALLFORD756
@SAMIEWALLFORD756 6 лет назад
Whoa!!!... Is suddenly a death trap of THIS elevator! Elevator needs fixtures and re-installed on the system modernized properly. How creepy done like this?!
@najlaallawati7232
@najlaallawati7232 6 лет назад
When i went to Iran there was a hotel called toos I rode the elevator it was a little bit different elevator when you reach the floor it under levels and mid levels
@crazydogeROBLOXBuildingandGame
Feel like the door drive may have something to do with it not opening its doors by itself on floor 1 and level B
@StrawPlayz1
@StrawPlayz1 6 лет назад
New elevators sometimes had some glitches here and there but this elevator wasnt calibrated right
@lucasnassar2778
@lucasnassar2778 6 лет назад
Straw Playz If is recent,they had to set in service,to make everyone know they're still in tests
@livionaves
@livionaves 6 лет назад
It went a little bit more down than necessary and had to pump some oil to level up correctly to the basement. The problem is that it did that abruptly. There is a video of some filmer where a Schindler Hydro in a dept. store did a similar thing while leveling down at the ground. Strange that this one didn't open the door automatically.
@blueauraretriever
@blueauraretriever 6 лет назад
Maverick 3458 I've been on TWO Schindler MT hydros this year that did the same thing. I think that's just a unique characteristic of the logic.
@StarCityElevators
@StarCityElevators 6 лет назад
Must be a fairly new thing. Either way, it's just enough of an issue to set the average person on edge like they're trapped. It might be that some sort of leveling switch/valve was not engaging at the proper time.
@lucasnassar2778
@lucasnassar2778 5 лет назад
Lívio,acontece que nesse vídeo a modernização não passou de uma semana,ou seja a máquina ainda deve estar aprendendo a funcionar,nem todos aprenderão a nivelar rapidamente,o Star City Elevators não poderia estar indo nele,é por isso que tem que esperar pelo menos um mês para calibrar tudo corretamente
@inkognito8888
@inkognito8888 6 лет назад
My university institute has an 60 years old elevator where you manually open the outside door. On each stop it jumps with such a strong jump you are unable to carry a full cup of tea within it. :-D
@watchmakerful
@watchmakerful 6 лет назад
This is typical for single speed traction elevators.
@HannahBug1
@HannahBug1 6 лет назад
That elevator makes scary noises. ;-;
@HannahBug1
@HannahBug1 6 лет назад
They should replace that elevator then.
@silasmcgee3647
@silasmcgee3647 6 лет назад
HannahBug1 or as a description says should have kept the older elevator
@EDISONTECH
@EDISONTECH 6 лет назад
7:55 Classic Leveling!
@AquaSea17
@AquaSea17 6 лет назад
Nice video
@inactivechannel7029
@inactivechannel7029 5 лет назад
Hey, you aren't the only one who has gotten stuck in a generic! I have too!
@drdog101schannel4
@drdog101schannel4 6 лет назад
And I Also Think That It Doesn't Open Due To The Fact That Once Its Done Releveling It Thinks It Already Opened And Closed, And The Time For The Door To Stay Open is Really Short So Thats Why The Controller Must Think That.
@JordanLoweElevaToursCanada
@JordanLoweElevaToursCanada 6 лет назад
This may be new but it could use some help. This controller on the elevator is really messed up!
@LuarAuditore
@LuarAuditore 6 лет назад
At 4:04 if you look carefully at the elevator it looks like it going up without the door closing
@luznoceda5862
@luznoceda5862 6 лет назад
Idk why but while u were doing this I was like: Stop it stop right now..
@HSETM
@HSETM 4 года назад
2nd guess: It might have hit one of the final limit switches
@MrEngineer20051
@MrEngineer20051 6 лет назад
At the end of this video when there was new padding in the Elevator, your talking was softer. And at the beginning of this video, when there was no new padding in the Elevator, your talking was louder.
@OPG2711
@OPG2711 6 лет назад
LOVELY.
@dickcheney6
@dickcheney6 6 лет назад
Not an elevator technician, but could it be the device that tracks the elevator's position?
@mattmoreira210
@mattmoreira210 Год назад
It could.
@Dewbertee
@Dewbertee 5 лет назад
Why I see a hand print on the left lol
@BitGridTV
@BitGridTV 6 лет назад
it might be a reasonable programming if the elevator does not open automatically when reaching the basement. think about water possibly being there or gas/smoke.
@lucasnassar2778
@lucasnassar2778 5 лет назад
BitGridTV Yes,just one week and it's not on full installations
@drdog101schannel4
@drdog101schannel4 6 лет назад
@Star City Elevators Thats Call Releveling, It's when the elevator went down too much from the basement and it had to use to hydraulic motor to go up again so that you can get out safely, So Really The Elevator Wasn't Malfunctioning.
@lucasnassar2778
@lucasnassar2778 5 лет назад
DRDOG101's Channel Yes it's still learning,an elevator in 1 week modded it's still learning the new things,cost any wait?
@Psevdonim123
@Psevdonim123 5 лет назад
The leveling is so painfully long! Even for hydraulic... The pump might be failing, as it overshot's the floor only on way down.
@StarCityElevators
@StarCityElevators 5 лет назад
It's a brand new elevator (not a mod)...and if you watch till the end of the video, you will see that they fixed it. I should probably do an update on that though...
@Psevdonim123
@Psevdonim123 5 лет назад
@@StarCityElevators Even if it's brand new there might have a leak or solenoid valve might have been too weak... New lifts (elevators) also can break especially in first two months or so. Because every installation is a bit unique and engineers need a time to set everything up correctly. I don't think that in this situation it was a wrong setting though... It might have been a manufacturing defect
@StarCityElevators
@StarCityElevators 5 лет назад
@@Psevdonim123 It's possible that might be what happened. Usually I give an elevator six months to a year to get up to "out of the box" working order. I don't remember how old this was though, probably less than a month.
@snddly84
@snddly84 6 лет назад
Seems to me that if it weren't for elevators this guy would be in his mother's basement staring down a dark hole muttering something about lotion and hoses...
@jaworskij
@jaworskij 5 лет назад
No matter how many times I replay this video I just can't understand what he's mumbling about at 0:22
@Jamestube8439
@Jamestube8439 6 лет назад
Instant door close.
@DaRealIlnois
@DaRealIlnois 6 лет назад
All those buttons
@scythal
@scythal 6 лет назад
If this happens really frequently, the buffer springs would wear out.
@rainalmida4436
@rainalmida4436 5 лет назад
I think the elevator can't stop at basement or 1st floor because there is no one lives there
@chrisblackstone5975
@chrisblackstone5975 6 лет назад
received a reply to my comment I had posted about this particular lift. What the individual doesn't realize when they wrote their reply is I have been watching videos like this for quite a while. So, it is easy to pick out a installation that is a garbage insall or badly maintained. This installation in this case is both a crap install and not kept up very well.
@lucasnassar2778
@lucasnassar2778 5 лет назад
Chris Blackstone Well but don't you know that a modded elevator when even did just one week it still can be in tests,why a person like has to ride without waiting the full installation,at this time the machine is still getting it's learnings
@HSETM
@HSETM 5 лет назад
It safety breaks at -1
@RaynFox
@RaynFox 6 лет назад
It was like the thing doesnt have brakes when it stopped at basment, but the real reason is, the floor is too close to the cab, so it stops, but the door wont open. And when you wanted to stop at 1, it forget to brake and slowly did go Down to the basement, Controller may be failing ;)
@drdog101schannel4
@drdog101schannel4 6 лет назад
and I also think it never opens cause the timer for the door to stay open is like.. really short so once its done releveling it thinks it already opened automaticly
@VOLTRONDEFENDER4440
@VOLTRONDEFENDER4440 6 лет назад
I hate when that happens
@albertsflamingo7993
@albertsflamingo7993 5 лет назад
I'M SO CONFUSE
@Jamestube8439
@Jamestube8439 6 лет назад
Not calibrated.
@chaterii8093
@chaterii8093 6 лет назад
I would of broke the alarm button for help
@AquaSea17
@AquaSea17 6 лет назад
The elevator was making creepy noises
@chrisblackstone5975
@chrisblackstone5975 6 лет назад
elevator is simply crap. I was listening to it going down and it is strange how it sounds like it stops for half a second and then from what it sounds like the pump kicks on and it continues to go down. I however also didn't like the sounds it made when it would go up or down at certain points.
@mataribrahim8500
@mataribrahim8500 6 лет назад
Chris Blackstone its crap huh? Ur lazy ass uses it everyday boi shut up
@AN-yy9cq
@AN-yy9cq 6 лет назад
That looks to be a major controller issue.
@dawnzephyr
@dawnzephyr 6 лет назад
Obvious question, did you let anyone know there was a problem?
@gracephipps9423
@gracephipps9423 5 лет назад
im scared of elevators so when he was standing in the door way I was like GET IN THE ELEVATOR BEFORE THE DOORS CRUSH YOU
@msj191961
@msj191961 6 лет назад
Garbage installation. Nothing more to say about it.
@supertechnocat8253
@supertechnocat8253 5 лет назад
Rushed Modernization? :/
@lucasnassar2778
@lucasnassar2778 5 лет назад
Super Techno Cat Actually he is wrong of riding something fresh out of the box,it's just one week in this video,why not wait once everything is done,the installations are complete?
@TransitUSA
@TransitUSA 6 лет назад
Hate to say it, but thats a POS.
@juggernaut911
@juggernaut911 6 лет назад
U have no life straight up
@bss1346
@bss1346 6 лет назад
Arash Mazand fuck off mate 😂 look at your views compared to his views...
Далее
Top 15 | Worst Elevators I Have Ever Filmed
35:41
Просмотров 72 тыс.
Auburn High School's Broken Elevator
3:59
Просмотров 77 тыс.
D3 BMW XM LABEL Король.
31:52
Просмотров 755 тыс.
Beautiful sport😍
00:20
Просмотров 237 тыс.
2023 Lift/Elevator Fails & Funny Moments Compilation
25:53
MUST WATCH!!!  I GOT STUCK IN THE ELEVATOR!!!
7:20
Просмотров 105 тыс.
How to Install an Elevator in your Living Room!
13:20
Car Wash Malfunction
15:42
Просмотров 940 тыс.
Weird Elevator Malfunction Caught on Camera!
6:26
Просмотров 73 тыс.
СТРИМ СТАНДОФФ 2 #shorts #standoff2
4:58:46
Просмотров 151 тыс.