Тёмный

ELITECH PT 500/800 Wireless Pressure Gauges Kit : Is it worth getting? 

Reliable HVACR
Подписаться 16 тыс.
Просмотров 13 тыс.
50% 1

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 66   
@swanjaymusic
@swanjaymusic 2 года назад
You get a big thumbs up for telling the truth and if they dont adjust the product then why bother with them... Winners make there products better. Losers think they got it right and just do not have a clue...
@ReliableHVACR
@ReliableHVACR 2 года назад
Thanks 🙌🏽 they're aware now and are looking into it. Hopefully it was just mine.
@philltafolla
@philltafolla 2 года назад
I been using the Elitech scale , Elitech leak detector, Elitech digital manifold, with no problems 🤷🏻‍♂️
@sethcrosby9371
@sethcrosby9371 Год назад
So I just bought this set. I been doing A/C and refrigeration for 11 years. Always used analogs and calculated subcool and superheat using temp clamps and using math the guys at my place of work like all the digital stuff until I was intrigued with wireless field pieces. I don’t want to pay $600 + for a setup so I saw these. Good review makes me feel better. I’m not too worried about the brass fittings leaking I can rig stuff up if needed. It’s amazing how technology came a long way . Thanks for the review
@petersamios5409
@petersamios5409 18 дней назад
Great honest review. I've seen in other reviews that you really have to tighten them down to avoid leaks - so you have confirmed this. I also like the displays - just wish the temp gauges also had small displays - that would be even better. As for the App, there may be an option in their Settings part that indicates the actions/connectivity of the probes when you turn off the probes. Something like always remember gauges drop when turned off. Something like that.
@HVACGUY
@HVACGUY 2 года назад
That rooster 🐔 was going nuts
@ReliableHVACR
@ReliableHVACR 2 года назад
I know 😂 there's a lot where I am now
@chrischairez7359
@chrischairez7359 Год назад
I've owned these 2-3 years and replaced the adapter with short hoses works incredible. Elitech released an update for the app
@johncannon7248
@johncannon7248 Месяц назад
The rubber bushing fell out of my high pressure hose the first time I used my new manifold. The fittings are cheap also surprised they are not low loss
@danielalvarez3567
@danielalvarez3567 4 месяца назад
These work great! Had them for 2 years now and never had an issue or leak. You need to use thread tape for the gauge threads and then add or use any fittings. But yes the fitting with curve does not work at all. Had same issue with that one.
@NickolasElliott-us9mk
@NickolasElliott-us9mk Год назад
I have an amazing product that can fix a ton of the issues you were having. Now this product is very new so I may be mispronouncing it but I think its called "Tephlan Tapè." It should be by the burn remover and your van's blinker fluid.
@ReliableHVACR
@ReliableHVACR Год назад
Maybe I didn't mention it but I clearly had it out at 8:17 with my nylog as well, nothing sealed it until I forced the crap out of it. But thank you for your awesome comment 👏🏽👏🏽👏🏽
@NickolasElliott-us9mk
@NickolasElliott-us9mk Год назад
@@ReliableHVACR I figured you were smart enough for it but I was just making a joke. I haven't run into the issues you had but the biggest issue I found it the weight of the gages themselves and the amount of fittings you need can all contribute to leaks. I overall like them for quick pressure readings but past that, I would use normal manifolds with small length hoses. I also work with equipment that can have a negative suction pressure so if I add my gauges as is, I can add air to the system.
@search_eternal
@search_eternal 2 года назад
Those gauges are best to mount on a manifold and leave them on it.
@ivancook1247
@ivancook1247 Год назад
Exactly
@HVACShopTalk
@HVACShopTalk Год назад
Nice and complete review, good work man
@ReliableHVACR
@ReliableHVACR Год назад
Appreciate it, thanks 🙌🏽
@jerometruitt2731
@jerometruitt2731 5 дней назад
For the price if the only thing wrong is cheap fittings id say its worth it. Fittings are wear items anyway.
@tomn4838
@tomn4838 Год назад
Adrian - good review. Best reviews are from the users in the field. Thanks for sharing.
@ReliableHVACR
@ReliableHVACR Год назад
Much appreciated!
@JeffBrown1966
@JeffBrown1966 2 года назад
Maybe mount them to an old manifold. And just do the hose
@ramonestrada38
@ramonestrada38 Год назад
I've had this set for awhile now. So far it's been great accept for the tee that has leaked from the beginning. I use it for quick diagnostic to measure pressure's otherwise I use my fieldpiece probs.
@myHVAClife
@myHVAClife 2 года назад
Should have put that money into the 6 piece FP JOB LINK set with air probes, when combined with the Measure Quick APP it will actually take the info from all probes and give you a diagnosis while giving you system performance data and tell you what your most likely issues are with the system! Pricey YES, but they give you every piece of info you need down to RH DB WB enthalpy and actual system capacity.
@travisb9130
@travisb9130 Год назад
Just purchased these, going to give them a shot. I have the Testo set and I cannot stand that you have to use your phone for everything. It's nice if you're going to be at one place for a while and can track everything on the phone and also get a data log to save for later but if you're just doing PM's and need to check a bunch of systems it's clunky at best. I usually keep just stubby individual gauges in my bag but then it's a pain getting the pipe temperature. I wish somebody would make a pipe clamp with a digital readout instead of the k-type clamp or full Wireless. That would be nice. Got the $17 Leak Detectors with my order as well so going to give them a try. Those might be nice to use on some of the bigger leaks that are easy to find before breaking out the H-10.
@tommyteamer9037
@tommyteamer9037 Год назад
Thank you for techcing how to use the digital Elitech Scale I like the hold set up.
@jakem117
@jakem117 2 года назад
I have the Appion ION PT set, love em. They stopped making em which is a shame. Thermistor accuracy is rated at + or - .27*F literally the most accurate thermistor I own. Looks like Appion or Elitech ripped off the name and style lol
@WallStreet749
@WallStreet749 2 месяца назад
Is there a reason your not using pipe dope or Teflon tape for leaks.
@arrealhandymanservice4459
@arrealhandymanservice4459 2 месяца назад
Need to put O rings in them they never fell out
@davidmorris2549
@davidmorris2549 2 месяца назад
2 questions 1 can i put these on a manifold and 2 can i use these on a Vacuum pump system without hurting them?
@ziggyd3114
@ziggyd3114 2 месяца назад
Would either the blue or the red work for simple nitrogen pressure test? I’m installing mini splits so there’s only a low side connection
@HVACRDUDE
@HVACRDUDE Год назад
Good review brother 👍🏼
@WswRefrigeration
@WswRefrigeration 2 года назад
I’m waiting on Fieldpiece to come out with a new gen probe with display
@ReliableHVACR
@ReliableHVACR 2 года назад
🤞🏽
@joeshearer1247
@joeshearer1247 2 года назад
So we have gone full circle back to wanting a display 😂😂
@WswRefrigeration
@WswRefrigeration 2 года назад
@@joeshearer1247 they never had probes with display
@WswRefrigeration
@WswRefrigeration 2 года назад
I don’t like having to use a phone when I juts want to do a quick check. I carry stubbies in my bag but compared to the probes they’re bulky. Probes in that size with a display would be a game changer
@user-nt1oo1kq8m
@user-nt1oo1kq8m 29 дней назад
can i use nitrogen?
@hvacslayer2929
@hvacslayer2929 2 года назад
The cheap version of appions ion gauges. I’ve been using mine(Appion) for over 4 years, they still work fine and the app still works even though they are discontinued. Idk if you ever saw the commercial appion made for these but they were ment to be abused. I’ve been seeing more of these Elitech stuff and honestly I’m not impressed something straight out of toys R us. We’ll see if this company is still around in couple years.
@jakem117
@jakem117 2 года назад
My Appion ION set is still going strong, wicked reliable and accurate. They say they're making a new set, but supply issues and C19 have delayed it until next year lol
@jerometruitt2731
@jerometruitt2731 5 дней назад
They're still around. Lol
@ramonestrada38
@ramonestrada38 Год назад
Probably for the DIY and for the new HVAC guy just starting out but can't afford the very expensive tool's just yet.
@MariosACandRefrigeration
@MariosACandRefrigeration 2 года назад
you need teflon on threads.
@ReliableHVACR
@ReliableHVACR 2 года назад
Tried that same thing, ended up just using nylog at the end
@billl3936
@billl3936 2 года назад
@@ReliableHVACR Did the nylon solve the problem of leaking? When switched couplers?
@rickrockin155
@rickrockin155 2 года назад
I just bought the fieldpiece, they re a bit pricey, and that s the exact reason i didnt go with the those chinese made digital gauges
@azryder5308
@azryder5308 11 месяцев назад
Are the temperature probes adjustable?
@tylork8025
@tylork8025 2 года назад
Still working good? I need a good set :)
@ReliableHVACR
@ReliableHVACR 2 года назад
Use them every now and then, I like em. Just be aware of the issues I had in the video
@dorondavid8537
@dorondavid8537 Год назад
How did you get to have both gages display on your phone I can only do one at a time If i add the second gages it is just switches to the other gage Never both together Any idea because your display both at the same time
@hvacwiz7877
@hvacwiz7877 Год назад
Elitech SMG-1
@fyrepowerfireprotection2209
what the range of the Bluetooth to the app
@T-Bone-nk1ng
@T-Bone-nk1ng 7 месяцев назад
All the app stuff is so silly to me. It's nice for getting additional info and whatnot as an option. But relying 100% on your phone is so annoying. 100° out and I am doing the connection dance and squinting at my phone. Just show me the goddamn numbers. I just need the numbers. Long story short these look slick af.
@carlossaenz4075
@carlossaenz4075 8 дней назад
I have about 25 years in the field. Never used these new tec stuff . Retired from hvac. I just order this new product. Seems good for the price but I hope it works. I have 30 days or more 8:26 warranty. Full refund. From Amazon. Still alot of money
@sal9616
@sal9616 3 месяца назад
can this be used to recharge an R134 system automotive?
@jerometruitt2731
@jerometruitt2731 5 дней назад
Yeah. Fittings and gauges are pretty much universal
@arealmaintenanceandrepairl1103
Just tryed mine had issues with recharging with the T idk I charged up it seemed like it got stuck in the t or something I ended up removing the shrewder valve in it and worked good.. seemed to either get stuck at the charging pressure or it would read no refrigerant idk
@ReliableHVACR
@ReliableHVACR Год назад
I had to use my own fittings for this all to work
@dannyboi7695
@dannyboi7695 Год назад
Will these work for a pressure cooker?
@jerometruitt2731
@jerometruitt2731 5 дней назад
The highest is 800 on the red gauge
@stephwaylonwells3218
@stephwaylonwells3218 2 года назад
👍
@danny281983kkjj
@danny281983kkjj Год назад
NOTHING BETTER THAN A YELLOW JACKET MANTOOTH GAUGES
@domboul572
@domboul572 4 месяца назад
I’ve been using them for about year. The fittings that come with them are dog shit. Awesome gauges though
@bigdaddy4975
@bigdaddy4975 2 года назад
Looks really cheap.
@livingstones1196
@livingstones1196 3 месяца назад
Elitech is junk. I have 2 that I’ll be returning. Went with the over $300.00 BluVac pro.
@AErefrigeration
@AErefrigeration 2 года назад
Looks like an unnecessary toy. imo
@ivancook1247
@ivancook1247 Год назад
I'm gonna mount them on a manifold , they leak
Далее
Comparing & Testing Several Valve Core Removal Tools
29:01
Школьник угомонил бандита!
01:00
Mini bag sealer
00:58
Просмотров 4,2 млн
Is Your A/C Unit About To Die? This Tool Doesn't Lie
10:03
Elitech DMG-4B Digital HVAC Manifold Review!
17:11
Просмотров 6 тыс.
Elitech LMG-10 Digital Manifold
9:40
Просмотров 17 тыс.
The Good and Bad of Various HVAC Smart Probes
14:37
Просмотров 12 тыс.
Elitech Intelligent Vacuum Pump
10:39
Просмотров 8 тыс.
What A Rookie MISTAKE!! | HVAC Life
9:35
Просмотров 208 тыс.
Best HVAC Manifold for Apprentices
9:21
Просмотров 49 тыс.
Testo 550 | HVAC Gauges | Complete Review
15:30
Просмотров 39 тыс.
Brazing Training for HVAC Technician
35:45
Просмотров 76 тыс.