Bench testing the new EME DLE111 Starter
The 3542 outrunner Electric motor that powers the starter pulls 16.38 amps and uses 192.9 watts for a cold starts. It pulls 8.19 amps and uses 95.9 watts for warm starts.
The DLE111 tacks 1400 rpm at reliable idle and 6600 rpm at full throttle on a 28 x 8 Xoar prop. That calculates to 56.29 pounds of static thrust or 11.034 HP. The engine the latest V3 and is new with only about 8 ounces of gas run through it for now.
5 сен 2024