Engineer Explains.. Boiler heat-exchangers blocked with sludge and scale. How to fix it correctly! 

HeatingGeek
Подписаться 28 тыс.
Просмотров 67 тыс.
50% 1

Check out the tools I use below. :-)
To support this content and get access to the PDF files to go with this training click here: / heatinggeeks
The PDFs for this video are not done yet!!! SOON.
Injector cleaning tool: rover.ebay.com/rover/1/710-534...
To support the channel and see the tools used day to day by me check out the links below:
1) CARHARTT Tool Roll amzn.to/2yGiexO
2) BAHCO Screwdriver with LED amzn.to/2Op5Ug1
2)BAHCO Screwdriver without LED amzn.to/2yEhLML
3)WERA Kraftform Kompakt Screwdriver amzn.to/2OnOe4K
4)WERA 0.8x4x100 Flat screwdriver amzn.to/2RNcpra
5) KNIPEX Alligator amzn.to/2RNctqU
5)KNIPEX Cobra amzn.to/2PA5YWY
same size as the alligator above just the “cobra” version
6)BAHCO Spanner amzn.to/2IW3iR8
6)BAHCO Spanner with slimline jaw amzn.to/2yHCq2i
7)CK Wire cutters amzn.to/2RP19dW
7)CK Wire cutters (shorter version) amzn.to/2OnJwnB
8)KNIPEX bent long nose pliers amzn.to/2IW9uZ3
9)TESTO 510 Digital U gauge amzn.to/2Cfz36a
9)TESTO Bluetooth U gauge amzn.to/2IW4t30
10)Mirror tool amzn.to/2OpKVKl
11)Cheap as chips pick set!!! amzn.to/2OpK10o
12)FLUKE alert volt stick amzn.to/2PxCYPF
13)MONUMENT Tailing Spanner amzn.to/2OrypK8
14)Tee Bar 4mm amzn.to/2yDPRAr
15)Tee bar 2mm amzn.to/2yzbjGA
16)Tee bar 2.5mm amzn.to/2OqqSvd
17)Full Tee bar set amzn.to/2yAoIyk
18)10mm ratchet spanner (flex head) amzn.to/2IWCoZ9
19)8mm ratchet spanner (flex head) amzn.to/2IUDZP5
20)14mm/15mm spanner amzn.to/2Aa6wgZ
21)BAHCO small spanner amzn.to/2RRkKKH
22)Cheap Lock knife amzn.to/2IWatZf
23)Sharpie amzn.to/2IVrxPk
24)Injector cleaning pins link coming soon. Review to follow.
25)Rothenberger 18” heavy-duty pipe wrench amzn.to/2ChkRd6
These are the heat duty ones I use.
26)Knipex (large) amzn.to/2OrgfIm
27)BAHCO 12” (not wide jaw) amzn.to/2Aatuob
28)Fluke 115 multimeter amzn.to/2OqaFpF
Drain down hose amzn.to/2RM4ZEN
Gas Tap Grease amzn.to/2SE0jRL
Led lights for the ​van. amzn.to/2Bh7RTQ
Fluke 101 multimeter amzn.to/2PoLP5g
Extech EX330 amzn.to/2AYq872
Silicone grease amzn.to/2Rnls4F
Fluke Twist Guard probes
amzn.to/2CfwCz4
Commando drills
amzn.to/2L5f50u
Weed Sprayer amzn.to/2Ryx1Hh
Large LDF amzn.to/2I0ss4d
NTC Clamps:
amzn.to/2GVUWL5

Опубликовано:

 

25 апр 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 184   
@asif530
@asif530 4 года назад
Absolute legend. This industry needs people like you. Keep up the fantastic work.
@HeatingGeek
@HeatingGeek 4 года назад
Thankyou. :-)
@tmautosstaustellcornwall5882
@tmautosstaustellcornwall5882 2 года назад
Brilliant explanation mate, I had an old boiler and took exchange rout and cleaned using your method it fixed the hot water getting colder , but didn’t power flush - then we moved
@Will-zv9xh
@Will-zv9xh 3 года назад
I love you brother! This channel is breakdown gold. Quality videos with top visual and verbal explanations. Thank you. Subbed and recommended 👌
@HeatingGeek
@HeatingGeek 3 года назад
Welcome aboard! Thanks for commenting too. I appreciate it. :-)
@richardking6066
@richardking6066 3 года назад
I flush the HW side by fitting a couple of isolating valves and a washing-machine Tee beneath the boiler, in the HW feed and flow pipes. I use a small pump to circulate white vinegar (5% acid) through the plate heat exchanger for an hour or so. Does a great job of descaling, for the cost of 5l of vinegar (about £5). In the US they seem to do this annually, and have the necessary valves fitted during a normal installation of a 'Tankless Boiler', as they call them. I just don't understand why it isn't also normal practice here in the UK! (I also mains-flush the heating side and radiators every two years)
@jaybee258jb
@jaybee258jb 2 года назад
Excellent work. Thank you. I wish my boiler man knew this before he replaced my boiler after multiple visits.
@russellbird2246
@russellbird2246 4 года назад
Awesome vid, no woffle straight to the point 👍🏻🔥
@HeatingGeek
@HeatingGeek 4 года назад
Thanks :-)
@krosfala
@krosfala 4 года назад
Great video again man!Thanks for sharing,we do the same thing here in Greece.1 problem i also wanted to add is that sometimes the acid might burn through the heat exchanger
@HeatingGeek
@HeatingGeek 4 года назад
It has never happened to me yet. Maybe one day it will
@krosfala
@krosfala 4 года назад
@@HeatingGeek Hope it never will:) It hasn t happpened to me either,many of my friends have expierenced it and told me to be carafull.I use an acid from aquamax and i mix it with a lot of water just to be safe
@skypirate4806
@skypirate4806 Год назад
The amount of Plate Heat Exchangers I have cleaned in the last 2 weeks is 9 so far, but I think your right, replacing the whole Plate and doing a Powerflush would be the best way. Great video. 👍👍👍
@955trainboy
@955trainboy 2 года назад
Great channel. Thoroughly enjoying it.
@Ed-fp9rx
@Ed-fp9rx 2 года назад
What a fantastic video, thankyou very much for taking the time to make it.
@piotrserafin9728
@piotrserafin9728 4 года назад
Absolute Legend, wish I could train with you, I do breakdowns but your knowledge just supercedes everything I've learned by a thousand miles. I used to be your Patreon but haven't been doing extremely well financially I know it sounds pathetic, still love watching your videos, stay safe Oliver
@HeatingGeek
@HeatingGeek 4 года назад
It's hard being a self-employed heating engineer. Don't stress it. :-) Enjoy the vids and stay safe. :-)
@rickshabin
@rickshabin 2 года назад
I removed the plate heat exchanger from my Buderus 2 years ago and rinsed it out with spirit of salt for about 1 hour. The closed circuit part was clean due to the circulation of the inhibitor but the other side was very black and clogged. I live in a hard water area. My tap water has been hot ever since. By the way, a good description of the symptoms of what happens when the exchanger gets clogged. I'm not a plumber by trade so it took me a while to diagnose the problem.
@ianstewart2486
@ianstewart2486 2 года назад
Yes! and i wish there were more guys like you.
@santiagobardelli5675
@santiagobardelli5675 3 года назад
Hi¡ great video¡ I am having low flow from my Baxi Duo Tec 28. I have checked cold water pressure is high enough (35 liters/minute) while hot water flow is no more than 6 liters/minutes: do you think it can be caused by heat exchanger (blocked)? Thanks
@strongbow310
@strongbow310 Год назад
Finally someone who knows what they are doing unlike all these people changing synchron motors when the spindle is stuck
@HeatingGeek
@HeatingGeek 6 месяцев назад
:-)
@Nibiru999
@Nibiru999 2 года назад
Hey thanks for this video it explained better than most. Some people siphon cleaner through the heat exchanger but isn’t this only going to clean the central heating side of thr plate?
@davidoshea1536
@davidoshea1536 4 года назад
Awesome video bud🔥, lovin it.👍. Hope to some more soon.🤞
@HeatingGeek
@HeatingGeek 4 года назад
Got a couple getting edited at the moment. I need permission for one of them first though. :-)
@brenndonherbert4583
@brenndonherbert4583 2 года назад
Excellent video mate 👌
@jeffbent5453
@jeffbent5453 3 года назад
Superb video. Lukewarm DHW issue solved. Much appreciated, thank you👍
@HeatingGeek
@HeatingGeek 3 года назад
Glad it helped. What boiler?
@jeffbent5453
@jeffbent5453 3 года назад
@@HeatingGeek Ravenheat CSI 85
@HeatingGeek
@HeatingGeek 3 года назад
@@jeffbent5453 Nice one. Thats an underrated boiler. :-)
@Newmusicreview
@Newmusicreview Год назад
Nice info bud….one of the best I’ve found.
@jockster5525
@jockster5525 2 года назад
Brilliant thanks for your efforts 👍 need some new videos from your ace channel
@antoniogalluccio4213
@antoniogalluccio4213 2 года назад
Replace the plate other than cleaning it will still get it blocked again if you don't powerflush it?
@ashbyts3900
@ashbyts3900 Год назад
Hi GEEK, Great video a few queries regarding domestic use. I currently have a Viessmann 200 W installed with a Spira-Cross low loss header fitted, light industrial pump to add to the circulation but in just over 3 years I've ditched two heat exchange plates. I've spoken with the plumber regarding dirt separation but the header should take care of this, I've also mentioned the hard water within our area and possibly installing a water softener. Do you think this could help??
@HeatingGeek
@HeatingGeek Год назад
I don't know the low loss header you speak about. How big is it? If it has a large bore the dirt should separate into the bottom of it. How do you clean it out though? Hard your installer cleaned it out?
@955trainboy
@955trainboy 2 года назад
How do you get your work from insurance companies and manufacturers? Are there specific channels, or do you just contact them directly?
@ianmoody7039
@ianmoody7039 4 года назад
Grand job as normal, top information
@HeatingGeek
@HeatingGeek 4 года назад
Glad you enjoyed it. Thanks for watching
@danieljackson3125
@danieljackson3125 3 года назад
Hi! I've got a Plate Heat Exchanger to change on a Logic + 30. Is it as easy as it looks? Is there anything I should watch out for or be aware of? First time changing one on a Logic. Thanks for your help and advice, it really does make a difference!
@HeatingGeek
@HeatingGeek 3 года назад
Same as all the others really. :-)
@stephenbrown5844
@stephenbrown5844 Год назад
Brilliant explanation mate👏👏😀👍❤️🇬🇧
@_Steven_S
@_Steven_S 4 года назад
Would a plate blockage cause a combi-fed shower head to whistle? Trying to narrow down wether the work the water company is doing in my area is causing my issue, or if it's the boiler, or if it's the mixer valve (~12 year old system).
@HeatingGeek
@HeatingGeek 4 года назад
Point of use issue must be the head. Try descaling that first :-)
@justtruth8310
@justtruth8310 8 месяцев назад
Im a plumbing and heating contractor here in the US and I install Navien quite a bit. I clean them using vinager thought eh service ports on the DHW side. The heating side do not normally clean. Replacing heat exchangers is common when customers do not clean their systems annually. I run the vinager through the HE for 45 minutes. Seems to do the job.
@HeatingGeek
@HeatingGeek 8 месяцев назад
I use spirits of salt all the time. Works fast and never really had any issues.
@moulesanctuary
@moulesanctuary 3 года назад
You are truly the oracle
@heatpump8566
@heatpump8566 4 года назад
Worcester will always replace a plate in warranty or on a service contract. Great video again 👍
@HeatingGeek
@HeatingGeek 4 года назад
Worcester also have the biggest plates of any boiler. :-) So they take longer to block. :-)
@Han-es8qu
@Han-es8qu 4 года назад
@@HeatingGeek Exactly, Worcester have the nicest design heat exchangers with lower heat transfer rate and massive surface area hence the lower incident of blockedge .
@poppabear1062
@poppabear1062 Год назад
Is a vinegar bath a good solution to unclug Bosch greenstar Heat Exchanger clogged with grime and scale. Furnace was not cleaned in 9 years and stopped. Did a clean up but flame won't stay on after cleaning goes on for a minute the flame dies. Remove as much as I could but the middle of the core still clogged. It seems there's no suction. Any advise? thanks
@HeatingGeek
@HeatingGeek Год назад
usually the heating side of the heat exchangers get blocked. I find, if the mains water side gets full of white scale it's easer for me to replace the whole heat exchanger. If however it is the heating side then use spirits of salt or a good system cleaner to remove the debris. I am usually in a hurry and thats why I use spirits of salt (very fast but very risky)
@danielflintoft9643
@danielflintoft9643 4 года назад
Hi what’s the name of the acid that you use to clean the sludge out?
@HeatingGeek
@HeatingGeek 4 года назад
Spirits of salt
@mrtopbreak333
@mrtopbreak333 Год назад
Hi, I'm a tenent and been without hot water for a week and the engineer has diagnosed the heat exchanger as the problem in the HIU the unit was made in 2006 and there are no longer spares for this unit. He has refered it back to the landlord that says it could take up to two weeks to replace the HIU. I can't be with out water for this long If I remove the exchanger myself would there be any benifit in doing a quick back flush. I only need it to last a couple of weeks? Or should I use the ACID method. I'm a trades man so and quite competent. Thanks
@HeatingGeek
@HeatingGeek Год назад
What area do you live?
@Adil92_
@Adil92_ 3 месяца назад
My hot water out of the tap is brownish colour after replacing a radiator and adding inhibitor to the system, do you think it is sludge coming out of the system? Or would you know what it could be. When I run it for a while the water goes near to clear
@HeatingGeek
@HeatingGeek 3 месяца назад
What type of cylinder do you have? If it's prismatic that could be the problem.
@mikede2331
@mikede2331 3 года назад
Nice video pal, Swansea here
@HeatingGeek
@HeatingGeek 3 года назад
Thanks for coming. :-)
@FuelingWit
@FuelingWit 4 года назад
Removing the plate, surly you need to replace the seals? Do you carry all the seals for the boilers for the plate?
@HeatingGeek
@HeatingGeek 4 года назад
I must have 75% of seals on the van :-)
@FuelingWit
@FuelingWit 4 года назад
HeatingGeek beautiful. By the way I messaged you Instagram regarding storage for seals and parts. Gone with raaco and festool 👍🏻
@danryan6191
@danryan6191 4 года назад
are you talking about the primary or secondary side blocking? and what do you use to dissolve the blockage?
@HeatingGeek
@HeatingGeek 4 года назад
Both. Have you watched the video?
@groovejet33
@groovejet33 4 года назад
brick cleaner, is probally the strongest, primary is sludge,you can try flushing and using ch cleaner. Secondry is , remove the plate and use acid to clean, let it sit and steep for 10 minutes or so....... Bob on son:)
@hikolanikola8775
@hikolanikola8775 4 месяца назад
i have a combination hotwater/heating boiler, and i have no clue whats going on.. It starts working, no hot water produced... it runs for few sec, then i can hear like water starting to boil, then it shuts of whats that?
@Shifty761989
@Shifty761989 3 года назад
Excellent video, can you use brick acid?
@HeatingGeek
@HeatingGeek 3 года назад
Yes, but its not as strong. I did used to use it. Mortex was my preferred brand. :-)
@conand1413
@conand1413 3 года назад
Fantastic video and great respect for integrity, honesty & generosity . Rare in this industry. Also, i have quick question, i seen videos posted about temp testing to see if plate heat ex is blocked by measuring the temp difference between the hot water pipe near boiler and the primary return to boiler (out of pump) they should be identical(5 c range) Is that correct and can you please explain how is that possible. How is that possible or true. Or it makes more sense that the heat diff between the primary flow and primary return is the heat gained by the cold water to become hot water. If p flow was 75 primary return 40 then temp lost (gained by cold water) will be 35c so if cold water was 10c then hot water will be 35+10=45c Is that correct? Also pls does boilers keep delta t 20 in hor water mode i.e for example primary flow 75c primary return 55.? Or not the case. If not is that mean the boiler condense more in hot water mode than in heating mode Much appreciate your reply Thanks again
@HeatingGeek
@HeatingGeek 3 года назад
Just from your questions I know your mind works like mine. I did start to do a series of test about this, but never got round to doing the video. The ΔT isn't kept to 20 or 11 (older boilers) in hot water mode. The boiler condenses less in HW mode because of higher return temperatures. You cant assume the temp difference between flow and return is the temp the mains will increase. The flow rate of both would have to be perfectly matched and also the heat transfer would need to be 100% to achieve that. The ΔT is still monitored in HW mode but only for safety reasons.
@conand1413
@conand1413 3 года назад
@@HeatingGeek thanks for a quick reply. So is the idea that the temp of the hot water pipe as just it leaves the boiler and the temp of hot water return after pump should be identical (5 c diff tolerance) is solid enough to say definitely we have blocked plate heat exchanger correct? I would love a video about that Thanks again and very very much appreciated
@firstman9273
@firstman9273 3 года назад
Can I buy a test kit to test the inhibitor level in my rads? and will it work by bleeding a rad a little bit to get the sample?
@HeatingGeek
@HeatingGeek 3 года назад
Im not too sure. I guess you can but I don't actually know. :-)
@bendeighton9844
@bendeighton9844 3 года назад
Yes you can by test kits Adey do one called ADEY PRO CHECK and yes just drain some water out of a radiator or bleed some water out.(same thing)
@micealdevlin9793
@micealdevlin9793 4 года назад
In Your Opinon What Is The Best Wall Hung Gas Fired Boiler Unit On The Market?
@HeatingGeek
@HeatingGeek 4 года назад
I have a video coming about that.
@lukemitchell6146
@lukemitchell6146 4 года назад
Good to know, thanks!
@HeatingGeek
@HeatingGeek 4 года назад
No problem!
@TheMt9398
@TheMt9398 Год назад
Hello, thanks for your clip. Can I please ask for your acid details? e.g the name, where to buy etc. Regards
@HeatingGeek
@HeatingGeek Год назад
It's spirits of salt. Very very dangerous. I don't recommend anyone using it.
@vincentmcdonnell9797
@vincentmcdonnell9797 Год назад
Great fitter 🙏
@HeatingGeek
@HeatingGeek Год назад
Thanks so much. I really appreciate the comment. I have loads of stuff filmed and will be back ASAP.
@sebastianhensby2365
@sebastianhensby2365 4 года назад
When power flushing existing combi boiler systems do we have to make sure the divertor is in hot water mode to make sure it cleans the plate or if possible place divertor in mid position ?
@aqib2000
@aqib2000 4 года назад
Sebastian Hensby connect the gas pipe to the condensation trap
@HeatingGeek
@HeatingGeek 4 года назад
Where would you be connecting the powerflush into the system?
@HeatingGeek
@HeatingGeek 4 года назад
@@aqib2000 Im not sure that would work?? I will give it a go. ;-/
@sebastianhensby2365
@sebastianhensby2365 4 года назад
@@HeatingGeek when you are powerflushing the system how do we make sure we're flushing through the plate heat exchanger ?
@aqib2000
@aqib2000 4 года назад
HeatingGeek it does require a lighter
@11982463
@11982463 2 года назад
What chemical is that please?
@kamalsharma790
@kamalsharma790 4 года назад
Glad you cleared that up mate! I had a powerflush done. Plumber spent the whole day on it and done a water test before and after. 3 months later the heat exchanger blocked up again. And has blocked up another 3 times since! Plumber said he was happy with his powerflush and suggested replacing some of my older radiators. Does this sound right?
@danryan6191
@danryan6191 4 года назад
if its the plate heat exchanger, it could be worth changing it now, cleaning would only be a way of prolonging the life of what you have currently, but wont be a cure.
@HeatingGeek
@HeatingGeek 4 года назад
When was the flush done? If 15 years ago then maybe he right. :-) If your system has loads of dead legs or it needs filling every week then it can be got clean enough. :-)
@kamalsharma790
@kamalsharma790 4 года назад
@@HeatingGeek the flush was done last year. Had 4 new heat exchangers from baxi since. The system and most of the radiators are 4 years old. I have 3 radiators that are 15 years old
@Snaggleplops
@Snaggleplops 4 года назад
Be worth fitting a magna filter to stop anything that the flush may have missed? doesn't take much to cause problems in the plate.
@kamalsharma790
@kamalsharma790 4 года назад
@@Snaggleplops already fitted mate. It doesnt seem to stop the big pieces..only the very fine ones
@yodhayyodhay
@yodhayyodhay 5 месяцев назад
Good teacher great explanation, now I know
@HeatingGeek
@HeatingGeek 5 месяцев назад
Glad it was helpful!
@edwardbalboa5528
@edwardbalboa5528 4 года назад
Brilliant
@HeatingGeek
@HeatingGeek 4 года назад
Glad you liked it. Are you an engineer? How do you do them?
@gregbenham5586
@gregbenham5586 4 года назад
Love the Dr Pipe comment. You are both great to watch but my god you do lose me sometimes, you my friend are a professor( no doubt cocked that spelling up)
@HeatingGeek
@HeatingGeek 4 года назад
I cant spell at all. :-) Dr pipe has some good knowledge too. :-)
@pizzablender
@pizzablender 10 месяцев назад
The factory service manual of the Remeha Tzerra Ace recommends cleaning the plate HX with citric acid, pH around 3. There is even a tool available.
@HeatingGeek
@HeatingGeek 6 месяцев назад
What tool? Do you have a part no? It would be interesting to see
@pizzablender
@pizzablender 6 месяцев назад
​@@HeatingGeek No part number in the sercive guide ( tools.remeha.nl/wp-content/uploads/sites/3/2019/12/Servicehandleiding-Tzerra-Ace.pdf ) but it is shown at page 38. On one end of the HX, the outlets are connected with a block. The other ens gets an input and output hose fitting. That would allow flushing the whole thing with a single flow of water.
@HeatingGeek
@HeatingGeek 5 месяцев назад
Sorry, this comment was heard for review. I guess because of the link. What a good bit of info. Thanks for that. I never knew any manufacture recommended it.
@davidbradley296
@davidbradley296 Год назад
Try using SDS+RTD. It is a safe-acid used by US Navy on heat transfer units, including potable water. SDS+RTD is inexpensive, hand safe, non-corrosive and environmentally friendly.
@HeatingGeek
@HeatingGeek 6 месяцев назад
Thanks for this. The only company that cam ups were i Ohio though
@joncoke8208
@joncoke8208 4 года назад
Thanks for the video liam gallagher
@HeatingGeek
@HeatingGeek 4 года назад
Who? :-)
@andrewmillwardwatford9410
@andrewmillwardwatford9410 4 года назад
Another great video. Love your clear and precise manner. My understanding is ; Scale is not always lime scale and often the primary side is scaled and fouled. Scale from hard water is lime scale. Cleaning stainless steel with the incorrect acid can cause Redox. This changes the stainless steel to a new alloy that may not resist corrosion. Kamco fx2 is phosphoric acid and citric acid and is suitable for cleaning plates with low risk of both injury and to the component. It takes longer to clean a plate though. If acid is used it must be neutralised before the plate is refitted or the system ph can be altered accelerating corrosion in the system. Imo inhibitors are a danger to a heating system. I dont disagree about your statement on inhibitor levels but we know they lead to system issues while systems treated to european standards are less likely to experience issues. On a recent course at imi it was explained that sealed system can be more prone to corrosion as micro bubbles can not be removed without vacuum de gassing. Please post your videos on the heating design forum your input is valued.
@HeatingGeek
@HeatingGeek 4 года назад
Thanks for your input. I will post it later in the week to FB. I used to carry FX2 but find it too slow. :-) I also use DS3 but again found it too slow. :-)
@andrewmillwardwatford9410
@andrewmillwardwatford9410 4 года назад
@@HeatingGeek yes it is slow. I understand your helpful approach. You do explain your logic and it's positive.
@Han-es8qu
@Han-es8qu 4 года назад
Yes Andrew, inhibitors cause more trouble than help. I have also noticed the system heavily dosed with it ,still had the HE blockedge on both heat exchangers at the similar rate. Also diaphragm in the DV didn't last very long in presence of the inhibitors. I think the best advice to reduce the scale and sludge is to reduce the heat 🔥 . keep the dial at 3/4 of the way at most.
@charlie12358
@charlie12358 4 года назад
When you said 'how do you unblock them' I just heard Iain's response from a team breif 'bang it on a kurb and flush it with water' I always wondered if he said that just to cover himself 😂
@HeatingGeek
@HeatingGeek 4 года назад
I liked working for BG. Nice easy contractor work. Good pay etc. What a load of shit that is now. :-)
@charlie12358
@charlie12358 4 года назад
@@HeatingGeek Wait until this winter starts were all gonna get calls to go back, I never really enjoyed it other that you was always local and I guess it was an easy life but I never thought the pay was great unless you worked away or did incentive work
@HeatingGeek
@HeatingGeek 4 года назад
@@charlie12358 I done well from BG. Found it a nice easy day and other than the "us/them" attitude from direct labour it was ok.
@garylawton7254
@garylawton7254 4 года назад
@@HeatingGeek mate your vids are brilliant im now a avid follower of your posts can i ask you on a combi i know its ok to work on the hot and cold (say changing a tap) while the heatings running but what do you do when your working on the heating side of things do you just always turn the power off at the spur or just turn the thermostat down to avoid any damage to boiler while say replacing a rad etc? Cheers
@kevint3845
@kevint3845 4 года назад
Agree with your comments but a lot will not go down the power flush route, they just get engineer after engineer and expect a magic wand from one of them.
@HeatingGeek
@HeatingGeek 4 года назад
Yep. If they pay, then why not. :-)
@surinderpaulkansal6977
@surinderpaulkansal6977 Год назад
how to clean main heat exchanger on Potterton combi
@marky5493
@marky5493 Год назад
Awesome he tells us how dangerous these chemicals ( 8 :05min) are then proceeds to let the chemicals pour down some outdoor drain with plants growing in it. gotta love the logic!!
@HeatingGeek
@HeatingGeek Год назад
Yeah, let the drain chemicals go down a drain??? The logic?
@marky5493
@marky5493 Год назад
@@HeatingGeek all those chemicals that you were warning about, then you just let it pour down into some random drain. Do you think that's a good idea if they so dangerous???
@HeatingGeek
@HeatingGeek 5 месяцев назад
Yes. :-) Its drain cleaner
@krzysztofkomor9877
@krzysztofkomor9877 2 года назад
Cool. After all, a normal professional.
@chiranagheorghitaeugeniuth98
@chiranagheorghitaeugeniuth98 2 года назад
why not put the heat exchanger into a ultrasound bath with a neutral cleaning solution woth a small aquarium pump connected to recirculate during the ultrasound bath?
@HeatingGeek
@HeatingGeek 2 года назад
Time and equipment.
@chiranagheorghitaeugeniuth98
@chiranagheorghitaeugeniuth98 2 года назад
@@HeatingGeek So it is applicable and I suspect more safe solution.
@HeatingGeek
@HeatingGeek 2 года назад
@@chiranagheorghitaeugeniuth98 Yes it is more safe. I do not know if it is a better solution? Limescale and sludge are very difficult to remove.
@whitebear5405
@whitebear5405 4 года назад
Yeah Worcester if it's in warranty replace plates
@1991elliot
@1991elliot 4 года назад
SWEP have a new technology called Sealix, which prevents scale.
@HeatingGeek
@HeatingGeek 4 года назад
Who is SWEP?
@bluedwarf8858
@bluedwarf8858 3 года назад
Instead of using a power flush,.especially on micobore pipes could you just use the adey magnacleanse and clear the plate heat exchanger with those two big magnets
@HeatingGeek
@HeatingGeek 3 года назад
No, I dont think you could. You need to increase flow to move the debris.
@bluedwarf8858
@bluedwarf8858 3 года назад
@@HeatingGeek thanks for the reply
@richardmitchell1520
@richardmitchell1520 3 года назад
Listened to your advice and was really lifted in my spirit.... ive a 20 something worcester heatslave oil boiler intermittently overheating and has now had 3 diverter cartridges in 18 months... and works perfectly for a few months only .. so decided to speak with another engineer and he says £1800 for new exchanger.. but ive looked and sourced several at around £100-£150.... i need more help and advice .. then i watched your video .. can you help..? Richard up in dundee
@HeatingGeek
@HeatingGeek 3 года назад
Cant help... Sorry :-)
@combatthebad6909
@combatthebad6909 3 года назад
My mums boiler not working properly saw water coming from near the heat exchanger engineer came said pipe not glued charged £65 didn't solve it came back 2hrs later said was heat exchanger
@powernab8457
@powernab8457 6 месяцев назад
👍👍
@hikolanikola8775
@hikolanikola8775 4 месяца назад
7:40, THATS EXACTLY WHATS HAPPENING TO MY BOILER! Whats the actuall issue? please
@HeatingGeek
@HeatingGeek 4 месяца назад
This is your problem. Watch the video
@hikolanikola8775
@hikolanikola8775 4 месяца назад
yeah but i can't hear the pump runing as well :// its a mess @@HeatingGeek
@HeatingGeek
@HeatingGeek 4 месяца назад
Then maybe no Hot water demand? Does your boiler show a hot water light
@chohanchohan8208
@chohanchohan8208 4 года назад
Insurers provide cover from 1 radiator system to 50plus...now every system has and will have sludge and limescale,hence they cannot cover failure due to sludge as the annual premiums will shoot from 80million to 1 3billion due to claim repaired due to sludge. That's why they protect policy T&C's it's not a get out clause it's to stop repairs to be carried out. Plus MI state systems must be flushed and have Magnetic filters serviced annually to ensure system is working without fault. I have annually serviced boilers I installed for last 8yrs have had little or no known fault due to sludge....
@HeatingGeek
@HeatingGeek 4 года назад
Yep. I know.
@lukebrown6913
@lukebrown6913 3 года назад
Insurance companies can cover under a full maintenance policy....problem is no one would pay the premium.....people always go for the cheapest!!!!
@Sash_Window
@Sash_Window 4 года назад
How do you get work from insurance companies?
@HeatingGeek
@HeatingGeek 4 года назад
Many years of applying. Been doing it on and off since I was 20. :-)
@paulPeasmarsh
@paulPeasmarsh 3 года назад
great video but.......all that nasty acid cleaning agent going down the drain isnt good for the environment 🙏
@jupitorman
@jupitorman 2 года назад
That acid will end up in rivers
@raykhan6416
@raykhan6416 Год назад
Thanks again not lot people are that straight
@HeatingGeek
@HeatingGeek 4 месяца назад
Sorry I didn’t respond to this comment. I didn’t see it in my feed. :-(
@henrybyrd5402
@henrybyrd5402 3 года назад
Another reason not to use the method you show. It is an offence to discharge acid or any other nasty chemical into a rainwater drain. In my village and many like it, anything down a rainwater drain goes straight into the local rivers, killing plant life and fish. Plumbers and builders are the main offenders not to mention car washers.
@HeatingGeek
@HeatingGeek 3 года назад
Your right.
@Mrcatcherye
@Mrcatcherye 3 года назад
fill with flux and warm water. Leave for an hour and flush it out
@HeatingGeek
@HeatingGeek 3 года назад
No time for that.
@squidlings
@squidlings 3 года назад
A plumber mixed with Ian Brown. Kinda funny
@JWS1968
@JWS1968 Год назад
Why don't boiler manufacturers make these heat echangers easier to replace. Surely they could be designed to be in a much easier place to get to. And even make them tooless to replace.
@HeatingGeek
@HeatingGeek Год назад
Vaillant have it front and center with only 4 screws to remove to get it out.
@umark6695
@umark6695 4 года назад
I thought everyone uses acid to clean a P2P! One shot usually does the job :-)
@HeatingGeek
@HeatingGeek 4 года назад
I always have :-)
@mgabrielle2343
@mgabrielle2343 3 года назад
Insurance companies are a big fraud, I cancel your domestic appliance insurance , save my money if my boiler goes wrong in 5 years I have saved over £500 and can then afford to replace a part with less than half that money.
@HeatingGeek
@HeatingGeek 3 года назад
I agree
@MrVM41
@MrVM41 4 года назад
Why aren't modern boiler fitted with or come with a water filter for hard water areas? That can be changed annually on service intervals. So annoying paying £100 for a service when all they do is put some probes in do some readings and go away without even changing the syphon water and all you get is a print out, sorry but you pay for a service to look after it and they know by design the heat exchanger is going to fail , and policy won't cover it, from what I've read they are going to bad gas boilers and make people switch to hydrogen boilers, I bet they will cost a bomb and be shit as well.
@HeatingGeek
@HeatingGeek 4 года назад
I think your right. :-)
@MrVM41
@MrVM41 4 года назад
HeatingGeek cheers for the videos they have been brilliant and informative
@inamkhorker7990
@inamkhorker7990 2 года назад
Your volume is crap. Can't hear,!
@HeatingGeek
@HeatingGeek 2 года назад
Why? other people haven't complained...
Далее
Heating Hacks: How to Safely Unblock A Cold Feed Pipe
16:25
I Wouldn't Do This For A Customer.....
36:36
Просмотров 29 тыс.